924 resultados para Calculation tool in reliability
Resumo:
Thermal effects are rapidly gaining importance in nanometer heterogeneous integrated systems. Increased power density, coupled with spatio-temporal variability of chip workload, cause lateral and vertical temperature non-uniformities (variations) in the chip structure. The assumption of an uniform temperature for a large circuit leads to inaccurate determination of key design parameters. To improve design quality, we need precise estimation of temperature at detailed spatial resolution which is very computationally intensive. Consequently, thermal analysis of the designs needs to be done at multiple levels of granularity. To further investigate the flow of chip/package thermal analysis we exploit the Intel Single Chip Cloud Computer (SCC) and propose a methodology for calibration of SCC on-die temperature sensors. We also develop an infrastructure for online monitoring of SCC temperature sensor readings and SCC power consumption. Having the thermal simulation tool in hand, we propose MiMAPT, an approach for analyzing delay, power and temperature in digital integrated circuits. MiMAPT integrates seamlessly into industrial Front-end and Back-end chip design flows. It accounts for temperature non-uniformities and self-heating while performing analysis. Furthermore, we extend the temperature variation aware analysis of designs to 3D MPSoCs with Wide-I/O DRAM. We improve the DRAM refresh power by considering the lateral and vertical temperature variations in the 3D structure and adapting the per-DRAM-bank refresh period accordingly. We develop an advanced virtual platform which models the performance, power, and thermal behavior of a 3D-integrated MPSoC with Wide-I/O DRAMs in detail. Moving towards real-world multi-core heterogeneous SoC designs, a reconfigurable heterogeneous platform (ZYNQ) is exploited to further study the performance and energy efficiency of various CPU-accelerator data sharing methods in heterogeneous hardware architectures. A complete hardware accelerator featuring clusters of OpenRISC CPUs, with dynamic address remapping capability is built and verified on a real hardware.
Resumo:
Auf Paulfallen basierende Experimente spielen eine wichtige Rolle in verschiedenen Bereichen der Physik, z.B. der Atomphysik zum Test theoretischer Modelle und der Massenspektroskopie. Die vorliegende Arbeit widmet sich beiden Themengebieten und gliedert sich entsprechend in zwei Teilbereiche: 1) Erdalkali-Ionen sind aufgrund ihrer Energieniveaus optimale Kandidaten für Laserspektroskopie-Experimente mit Ionenfallen und bestens geeignet, um mittels der spektroskopischen Daten die theoretischen Modelle zu testen. Lediglich für Ra+ fehlen bislang als einzigem Erdalkali-Ion diese Daten wie z.B. die Lebensdauern der metastabilen Niveaus. Diese wären auch von Interesse für bereits geplante Radium-Experimente zur Paritätsverletzung. Im ersten Teil dieser Arbeit wird der Aufbau eines Laser-Paulfallenexperiments zur Messung der Lebensdauer des 6D3/2 Zustands von 226Ra+ dokumentiert und es werden Testmessungen mit 138Ba+ vorgestellt. 2) Für die Verwendung der Paulfalle in der Massenspektroskopie und zur Analyse von Reaktionsprodukten ist die Kenntnis der Lage der im Speicherbereich auftretenden nichtlinearen Resonanzen wesentlich, ebenso wie deren Veränderung durch Dämpfung und Raumladung. Im zweiten Teil dieser Arbeit werden detaillierte Untersuchungen der Speicherung großer puffergasgekühlter Ionenwolken an zwei unterschiedlichen Paulfallen-Experimenten vorgestellt. Am ersten wurden 138Ba+-Ionenwolken kontinuierlich durch Laserspektroskopie bzw. über einen elektronischen Nachweis beobachtet, während das zweite N2+-Molekülionen automatisiert destruktiv nachwies. Am N2+-Experiment wurden zwei hochaufgelöste Messungen des ersten Speicherbereichs durchgeführt, die erstmals eine direkte Überprüfung der theoretisch berechneten Verläufe der Resonanzen mit experimentellen Daten erlauben. Die Nachweiseichung ermöglichte dabei zum ersten Mal die Angabe absoluter Ionenzahlen. Im Gegensatz zu vergleichbaren früheren Messungen wurden hierbei die sich überlagernden Speicherbereiche von 4 simultan gespeicherten Ionensorten beobachtet und zur Analyse der Resonanzen herangezogen. Die nichtlinearen Resonanzen wurden untersucht bei Variation von Puffergasdruck und Ionenzahl, wobei kollektive Resonanzen ohne zusätzliche externe Anregung beobachtet wurden. Die gemessenen Raumladungsverschiebungen wurden mit theoretischen Modellen verglichen. Bei Variation des Puffergasdrucks wurde mit Bariumionen die räumliche Ausdehnung der Ionenwolke gemessen und mit Stickstoffionen die Verschiebung des Punktes optimaler Speicherung bestimmt. Dabei wurde festgestellt, daß der zum Ioneneinfang optimale Puffergasdruck kleiner ist als der, bei dem die längsten Speicherdauern erzielt werden. Mit gespeicherten N2+-Ionen wurde die Position extern angeregter kollektiver und individueller Resonanzen im Frequenzspektrum bei Änderung der Parameter Ionenzahl, Puffergasdruck und Dauer der Anregung untersucht, ebenso wie die Resonanzform, die mit theoretischen Linienformen verglichen wurde. Bei Änderung der Fallenparameter wurden verstärkende Effekte zwischen nahen kollektiven Resonanzen festgestellt. Die Beobachtung, welche der im Frequenzspektrum vorher identifizierten Bewegungs-Resonanzen sich bei Variation der Fallenparameter a bzw. q überlagern, ermöglicht eine bislang nicht beschriebene einfache Methode der Bestimmung von nichtlinearen Resonanzen im Stabilitätsdiagramm.
Resumo:
Aim of this study is to describe the possible diagnostic value of sleep disturbances in the differential diagnosis of neurodegenerative diseases characterized by parkinsonism at onset. 42 consecutive patients with parkinsonian features and disease duration up to 3 years were included in the BO-ProPark study. Each patient was evaluated twice, at baseline (T0) and 16 months later (T1). Patients were diagnosed as Parkinson disease (PD, 27 patients), PD plus (PD with cognitive impairment/dementia or dysautonomia, 4 patients) and parkinsonian syndrome (PS, 11 patients). All patients underwent a full night video-polysomnography scored by a neurologist blinded to the clinical diagnosis. Sleep efficiency and total sleep time were reduced in all patients; wake after sleep onset was higher in patients with atypical parkinsonisms than in PD patients. No significant differences between groups of patients were detected in other sleep parameters. The mean percentage of epochs with enhanced tonic muscle EMG activity during REM sleep was higher in PD plus and PS than in PD. No difference in phasic muscle EMG activity during REM sleep was seen between the two groups. REM behaviour disorder was more frequent in PD plus and PS than in PD patients. Our data suggest that REM sleep motor control is more frequently impaired at disease onset in patients with PS and PD plus compared to PD patients. The presence of RBD or an enhanced tonic muscle EMG activity in a patient with recent onset parkinsonian features should suggest a diagnosis of atypical parkinsonism, rather than PD. More data are needed to establish the diagnostic value of these features in the differential diagnosis of parkinsonisms. The evaluation of sleep disorders may be a useful tool in the differential diagnosis of parkinsonism at onset.
Resumo:
La prova informatica richiede l’adozione di precauzioni come in un qualsiasi altro accertamento scientifico. Si fornisce una panoramica sugli aspetti metodologici e applicativi dell’informatica forense alla luce del recente standard ISO/IEC 27037:2012 in tema di trattamento del reperto informatico nelle fasi di identificazione, raccolta, acquisizione e conservazione del dato digitale. Tali metodologie si attengono scrupolosamente alle esigenze di integrità e autenticità richieste dalle norme in materia di informatica forense, in particolare della Legge 48/2008 di ratifica della Convenzione di Budapest sul Cybercrime. In merito al reato di pedopornografia si offre una rassegna della normativa comunitaria e nazionale, ponendo l’enfasi sugli aspetti rilevanti ai fini dell’analisi forense. Rilevato che il file sharing su reti peer-to-peer è il canale sul quale maggiormente si concentra lo scambio di materiale illecito, si fornisce una panoramica dei protocolli e dei sistemi maggiormente diffusi, ponendo enfasi sulla rete eDonkey e il software eMule che trovano ampia diffusione tra gli utenti italiani. Si accenna alle problematiche che si incontrano nelle attività di indagine e di repressione del fenomeno, di competenza delle forze di polizia, per poi concentrarsi e fornire il contributo rilevante in tema di analisi forensi di sistemi informatici sequestrati a soggetti indagati (o imputati) di reato di pedopornografia: la progettazione e l’implementazione di eMuleForensic consente di svolgere in maniera estremamente precisa e rapida le operazioni di analisi degli eventi che si verificano utilizzando il software di file sharing eMule; il software è disponibile sia in rete all’url http://www.emuleforensic.com, sia come tool all’interno della distribuzione forense DEFT. Infine si fornisce una proposta di protocollo operativo per l’analisi forense di sistemi informatici coinvolti in indagini forensi di pedopornografia.
Resumo:
Dysfunction of Autonomic Nervous System (ANS) is a typical feature of chronic heart failure and other cardiovascular disease. As a simple non-invasive technology, heart rate variability (HRV) analysis provides reliable information on autonomic modulation of heart rate. The aim of this thesis was to research and develop automatic methods based on ANS assessment for evaluation of risk in cardiac patients. Several features selection and machine learning algorithms have been combined to achieve the goals. Automatic assessment of disease severity in Congestive Heart Failure (CHF) patients: a completely automatic method, based on long-term HRV was proposed in order to automatically assess the severity of CHF, achieving a sensitivity rate of 93% and a specificity rate of 64% in discriminating severe versus mild patients. Automatic identification of hypertensive patients at high risk of vascular events: a completely automatic system was proposed in order to identify hypertensive patients at higher risk to develop vascular events in the 12 months following the electrocardiographic recordings, achieving a sensitivity rate of 71% and a specificity rate of 86% in identifying high-risk subjects among hypertensive patients. Automatic identification of hypertensive patients with history of fall: it was explored whether an automatic identification of fallers among hypertensive patients based on HRV was feasible. The results obtained in this thesis could have implications both in clinical practice and in clinical research. The system has been designed and developed in order to be clinically feasible. Moreover, since 5-minute ECG recording is inexpensive, easy to assess, and non-invasive, future research will focus on the clinical applicability of the system as a screening tool in non-specialized ambulatories, in order to identify high-risk patients to be shortlisted for more complex investigations.
Resumo:
Die Positronen-Emissions-Tomographie (PET) ist ein leistungsstarkes, nicht-invasives, bildgebendes Verfahren in der Nuklearmedizin und hat darüber hinaus zunehmende Bedeutung in der Arzneistoffentwicklung. Zur Verbesserung des therapeutischen Index von niedermolekularen Pharmaka werden vermehrt Wirkstofftransportsysteme eingesetzt. Eine Klasse dieser Wirkstofftransportsysteme sind Liposomen. Die Weiterentwicklung der klassischen Liposomen sind sogenannte „Stealth“-Liposomen, die eine Polyethylenglykol (PEG)-Korona zur Herabsetzung der Erkennung und Ausscheidung tragen. Zur (Weiter-)Entwicklung und deren in vivo-Evaluierung bietet die PET die Möglichkeit, die Auswirkungen von strukturellen Anpassungen auf die pharmakokinetischen Eigenschaften solcher Transportsysteme zu untersuchen. Zur Evaluierung neuartiger, cholesterolverankerter, linear-hyperverzweigter Polyglycerole (Ch-PEG-hbPG) als sterisch stabilisierende Polymere in Liposomen wurden diese im Rahmen dieser Arbeit mit der prosthetischen Gruppe 18F-TEG-N3 über kupferkatalysierte Alkin-Azid Cycloaddition (CuAAC) in sehr hohen Ausbeuten radiomarkiert. Zum systematischen Vergleich des in vivo-Verhaltens wurde ebenfalls ein cholesterolbasiertes lineares PEG (Ch-PEG) mit CuAAC nahezu quantitativ radiomarkiert. Als drittes Element wurde die Direktmarkierung von Cholesterol mit [18F]F- entwickelt. Diese drei Verbindungen wurden zuerst separat als Einzelkomponenten und anschließend, in Liposomen formuliert, in Tierstudien an Mäusen hinsichtlich ihrer initialen Pharmakokinetik und Biodistribution untersucht. Dabei zeigte sich ein ähnliches Verhalten der neuartigen Ch-PEG-hbPG-Derivate zu den bekannten Ch-PEG, mit dem Vorteil der Multifunktionalität an den hyperverzweigten Strukturen. Die liposomalen Strukturen mit der neuartigen sterischen Stabilisierung wiesen eine erhöhte Blutzirkulationszeit und vorteilhafte Blut-zu-Leber- und Blut-zu-Lunge-Verhältnisse im Vergleich zu den linear stabilisierten Analoga auf.rnEine weitere Klasse von Wirkstofftransportsystemen sind polymere Trägersysteme wie pHPMA. Alkinfunktionalisierte Polymere konnten in zwei verschiedenen Größen (~12 und 60 kDa) mittels CuAAC in sehr hohen Ausbeuten mit der prosthetischen Gruppe 18F-TEG-N3 radiomarkiert werden. Bicyclononinderivate der gleichen Größen konnten ohne Kupferkatalyse über ringspannungsvermittelte Alkin-Azid-Cycloaddition (SPAAC) mikrowellengestützt markiert werden und stehen somit zur in vivo-Untersuchung hinsichtlich des Einflusses der Markierungsart zur Verfügung.
Resumo:
OBJECTIVES: The aim of this randomised clinical trial was to investigate if a laser fluorescence device is able to discriminate between sound and carious approximal sites and between enamel and dentinal lesions, as well as to find appropriate cut-off values. METHODS: One hundred and seventeen sound or uncavitated carious sites in permanent molars were visually and radiographically examined, then either opened or not, after which their laser fluorescence was measured. Forty-three lesions were opened, the caries removed and the clinically identified caries depths were registered in addition to the radiographical scoring. Seventy-four sites were radiographically deemed sound or had enamel caries and were not opened. Here, the radiographical scorings were registered. RESULTS: Taking the radiographic scoring as gold standard for all investigated approximal sites, sound sites (D(0), n=40) showed significantly lower laser fluorescence measurements than carious sites (D(1-4), n=77) (Mann-Whitney test, P<0.025) suggesting a cut-off at 7 (sensitivity=0.68, specificity=0.7). Comparing measurements of D(0-2) (n=74) and D(3,4) (n=43), the results were also different by a statistically significant amount (P<0.025) and the cut-off calculated to be 16 (sensitivity=0.6, specificity=0.84). A fair positive correlation between laser fluorescence values and radiographical scoring was found (rho=+0.47, P<0.01). Analysing the 43 opened lesions with their clinically found lesion depths as gold standard, there was a fair positive correlation to the laser fluorescence values (rho=+0.34, P=0.03) and a moderately strong correlation to the radiographic scoring (rho=+0.67, P<0.01). CONCLUSION: The device may be an adjunct tool in the approximal detection of caries along with established procedures.
Resumo:
The electron Monte Carlo (eMC) dose calculation algorithm in Eclipse (Varian Medical Systems) is based on the macro MC method and is able to predict dose distributions for high energy electron beams with high accuracy. However, there are limitations for low energy electron beams. This work aims to improve the accuracy of the dose calculation using eMC for 4 and 6 MeV electron beams of Varian linear accelerators. Improvements implemented into the eMC include (1) improved determination of the initial electron energy spectrum by increased resolution of mono-energetic depth dose curves used during beam configuration; (2) inclusion of all the scrapers of the applicator in the beam model; (3) reduction of the maximum size of the sphere to be selected within the macro MC transport when the energy of the incident electron is below certain thresholds. The impact of these changes in eMC is investigated by comparing calculated dose distributions for 4 and 6 MeV electron beams at source to surface distance (SSD) of 100 and 110 cm with applicators ranging from 6 x 6 to 25 x 25 cm(2) of a Varian Clinac 2300C/D with the corresponding measurements. Dose differences between calculated and measured absolute depth dose curves are reduced from 6% to less than 1.5% for both energies and all applicators considered at SSD of 100 cm. Using the original eMC implementation, absolute dose profiles at depths of 1 cm, d(max) and R50 in water lead to dose differences of up to 8% for applicators larger than 15 x 15 cm(2) at SSD 100 cm. Those differences are now reduced to less than 2% for all dose profiles investigated when the improved version of eMC is used. At SSD of 110 cm the dose difference for the original eMC version is even more pronounced and can be larger than 10%. Those differences are reduced to within 2% or 2 mm with the improved version of eMC. In this work several enhancements were made in the eMC algorithm leading to significant improvements in the accuracy of the dose calculation for 4 and 6 MeV electron beams of Varian linear accelerators.
Resumo:
Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management.
Resumo:
By measuring the total crack lengths (TCL) along a gunshot wound channel simulated in ordnance gelatine, one can calculate the energy transferred by a projectile to the surrounding tissue along its course. Visual quantitative TCL analysis of cut slices in ordnance gelatine blocks is unreliable due to the poor visibility of cracks and the likely introduction of secondary cracks resulting from slicing. Furthermore, gelatine TCL patterns are difficult to preserve because of the deterioration of the internal structures of gelatine with age and the tendency of gelatine to decompose. By contrast, using computed tomography (CT) software for TCL analysis in gelatine, cracks on 1-cm thick slices can be easily detected, measured and preserved. In this, experiment CT TCL analyses were applied to gunshots fired into gelatine blocks by three different ammunition types (9-mm Luger full metal jacket, .44 Remington Magnum semi-jacketed hollow point and 7.62 × 51 RWS Cone-Point). The resulting TCL curves reflected the three projectiles' capacity to transfer energy to the surrounding tissue very accurately and showed clearly the typical energy transfer differences. We believe that CT is a useful tool in evaluating gunshot wound profiles using the TCL method and is indeed superior to conventional methods applying physical slicing of the gelatine.
Resumo:
Background Many medical exams use 5 options for multiple choice questions (MCQs), although the literature suggests that 3 options are optimal. Previous studies on this topic have often been based on non-medical examinations, so we sought to analyse rarely selected, 'non-functional' distractors (NF-D) in high stakes medical examinations, and their detection by item authors as well as psychometric changes resulting from a reduction in the number of options. Methods Based on Swiss Federal MCQ examinations from 2005-2007, the frequency of NF-D (selected by <1% or <5% of the candidates) was calculated. Distractors that were chosen the least or second least were identified and candidates who chose them were allocated to the remaining options using two extreme assumptions about their hypothetical behaviour: In case rarely selected distractors were eliminated, candidates could randomly choose another option - or purposively choose the correct answer, from which they had originally been distracted. In a second step, 37 experts were asked to mark the least plausible options. The consequences of a reduction from 4 to 3 or 2 distractors - based on item statistics or on the experts' ratings - with respect to difficulty, discrimination and reliability were modelled. Results About 70% of the 5-option-items had at least 1 NF-D selected by <1% of the candidates (97% for NF-Ds selected by <5%). Only a reduction to 2 distractors and assuming that candidates would switch to the correct answer in the absence of a 'non-functional' distractor led to relevant differences in reliability and difficulty (and to a lesser degree discrimination). The experts' ratings resulted in slightly greater changes compared to the statistical approach. Conclusions Based on item statistics and/or an expert panel's recommendation, the choice of a varying number of 3-4 (or partly 2) plausible distractors could be performed without marked deteriorations in psychometric characteristics.
Resumo:
CBV is a vital perfusion parameter in estimating the viability of brain parenchyma (eg, in cases of ischemic stroke or after interventional vessel occlusion). Recent technologic advances allow parenchymal CBV imaging tableside in the angiography suite just before, during, or after an interventional procedure. The aim of this work was to analyze our preliminary clinical experience with this new imaging tool in different neurovascular interventions.
Resumo:
Adrenocortical tumors are rare in children and present with variable signs depending on the type of hormone excess. We herein describe the unusual presentation of a child with adrenocortical tumor and introduce the concept of in vitro chemosensitivity testing. CASE REPORT: A 10.5-year-old girl presented with hypertrichosis/hirsutism and weight loss. The weight loss and behavioral problems, associated with halted puberty and growth, led to the initial diagnosis of anorexia nervosa. However, subsequent weight gain but persisting arrest in growth and puberty and the appearance of central fat distribution prompted further evaluation. RESULTS AND FOLLOW-UP: 24h-urine free cortisol was elevated. Morning plasma ACTH was undetectable, while cortisol was elevated and circadian rhythmicity was absent. Thus a hormonally active adrenal cortical tumor (ACT) was suspected. On magnetic resonance imaging (MRI) a unilateral, encapsulated tumor was found which was subsequently removed surgically. Tissue was investigated histologically and for chemosensitivity in primary cell cultures. Although there were some risk factors for malignancy, the tumor was found to be a typical adenoma. Despite this histology, tumor cells survived in culture and were sensitive to cisplatin in combination with gemcitabine or paclitaxel. At surgery, the patient was started on hydrocortisone replacement which was unsuccessfully tapered over 3 months. Full recovery of the hypothalamus-pituitary-adrenal axis occurred only after 3 years. CONCLUSIONS: The diagnosis of a hormonally active adrenocortical tumor is often delayed because of atypical presentation. Cortisol replacement following unilateral tumor excision is mandatory and may be required for months or years. Individualized chemosensitivity studies carried out on primary cultures established from the tumor tissue itself may provide a tool in evaluating the effectiveness of chemotherapeutic drugs in the event that the adrenocortical tumor may prove to be carcinoma.
Resumo:
Chronic lung infections by Pseudomonas aeruginosa strains are a major cause of morbidity and mortality in cystic fibrosis (CF) patients. Although there is no clear evidence for a primary defect in the immune system of CF patients, the host is generally unable to clear P. aeruginosa from the airways. PTX3 is a soluble pattern recognition receptor that plays nonredundant roles in the innate immune response to fungi, bacteria, and viruses. In particular, PTX3 deficiency is associated with increased susceptibility to P. aeruginosa lung infection. To address the potential therapeutic effect of PTX3 in P. aeruginosa lung infection, we established persistent and progressive infections in mice with the RP73 clinical strain RP73 isolated from a CF patient and treated them with recombinant human PTX3. The results indicated that PTX3 has a potential therapeutic effect in P. aeruginosa chronic lung infection by reducing lung colonization, proinflammatory cytokine levels (CXCL1, CXCL2, CCL2, and IL-1β), and leukocyte recruitment in the airways. In models of acute infections and in in vitro assays, the prophagocytic effect of PTX3 was maintained in C1q-deficient mice and was lost in C3- and Fc common γ-chain-deficient mice, suggesting that facilitated recognition and phagocytosis of pathogens through the interplay between complement and FcγRs are involved in the therapeutic effect mediated by PTX3. These data suggested that PTX3 is a potential therapeutic tool in chronic P. aeruginosa lung infections, such as those seen in CF patients.
Resumo:
INTRODUCTION: This case report describes the anaesthetic management of exploratory thoracoscopy and alternating one lung ventilation (OLV) in a dog with a pulmonary bulla, and the application of continuous positive airway pressure (CPAP) to the non-ventilated lung for preventing and treating hypoxia. CASE HISTORY: A 6-year-old, male castrated Border collie was scheduled for exploratory thoracoscopy to investigate spontaneous pnemothorax that had not resolved with repeated suction. Specific requirements for the thoracoscopy were alternating OLV to allow the surgical access to the right middle lobe and its removal, and the examination of the left hemithorax to rule out the presence of other lesions. DIAGNOSIS AND MANAGEMENT: Selective lung ventilation was performed with a double lumen endobronchial tube (DLT), inserted under endoscopic guidance. After a short period of two lung ventilation during preparation of the surgical field, alternating OLV was performed, combining CPAP, provided to the non-ventilated lung via a Mapleson D breathing system, and positive end-expiratory pressure (PEEP) applied to the ventilated lung. Left OLV occurred first and resection of the right middle pulmonary lobe was successfully performed; right OLV followed to allow the examination of the left hemithorax. DISCUSSION AND CONCLUSIONS: The combination of CPAP and PEEP resulted in a satisfactory intra-operative management of hypoxemia. Alternating OLV can be performed successfully by using a DLT. CPAP, commonly employed in human medicine, should be considered an important tool in the anaesthetic management of OLV in small animals.