1000 resultados para CT colonography (virtual colonoscopy)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Virtual reality (VR) simulators are widely used to familiarize surgical novices with laparoscopy, but VR training methods differ in efficacy. In the present trial, self-controlled basic VR training (SC-training) was tested against training based on peer-group-derived benchmarks (PGD-training). METHODS: First, novice laparoscopic residents were randomized into a SC group (n = 34), and a group using PGD-benchmarks (n = 34) for basic laparoscopic training. After completing basic training, both groups performed 60 VR laparoscopic cholecystectomies for performance analysis. Primary endpoints were simulator metrics; secondary endpoints were program adherence, trainee motivation, and training efficacy. RESULTS: Altogether, 66 residents completed basic training, and 3,837 of 3,960 (96.8 %) cholecystectomies were available for analysis. Course adherence was good, with only two dropouts, both in the SC-group. The PGD-group spent more time and repetitions in basic training until the benchmarks were reached and subsequently showed better performance in the readout cholecystectomies: Median time (gallbladder extraction) showed significant differences of 520 s (IQR 354-738 s) in SC-training versus 390 s (IQR 278-536 s) in the PGD-group (p < 0.001) and 215 s (IQR 175-276 s) in experts, respectively. Path length of the right instrument also showed significant differences, again with the PGD-training group being more efficient. CONCLUSIONS: Basic VR laparoscopic training based on PGD benchmarks with external assessment is superior to SC training, resulting in higher trainee motivation and better performance in simulated laparoscopic cholecystectomies. We recommend such a basic course based on PGD benchmarks before advancing to more elaborate VR training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the characteristics of a representative set of seven different virtual laboratories (VLs) aimed for science teaching in secondary school. For this purpose, a 27-item evaluation model that facilitates the characterization of the VLs was prepared. The model takes into account the gaming features, the overall usability, and also the potential to induce scientific literacy. Five of the seven VLs were then tested with two larger and highly heterogenic groups of students, and in two different contexts – biotechnology and physics, respectively. It is described how the VLs were received by the students, taking into account both their motivation and their self-reported learning outcome. In some cases, students’ approach to work with the VLs was recorded digitally, and analyzed qualitatively. In general, the students enjoyed the VL activities, and claimed that they learned from them. Yet, more investigation is required to address the effectiveness of these tools for significant learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Posttransplant lymphoproliferative disease (PTLD) is, aside skin cancer, the most common malignancy occurring after solid organ transplant in adults. Fluorodeoxyglucose (FDG) positron emission tomography (PET) has proved useful in the management of lymphomas. METHODS: We report our experience with the use of FDG-PET inline with computed tomography (CT) scanning in the management of four transplant recipients with histologically confirmed PTLD, including three monomorphic PTLDs and one polymorphic PTLD. RESULTS: FDG-PET/CT scan at diagnosis showed increased FDG uptake in all examined PTLD lesions, and the disease was upstaged on the basis of FDG-PET/CT scan results over conventional CT scanning in one patient. At the end of treatment, PET/CT scans no longer demonstrated FDG uptake in the original PTLD lesions in all patients. Complete remission of disease persisted for at least 1 year after diagnosis in all. CONCLUSIONS: Our results strongly support that FDG-PET scanning is highly specific for diagnosis and follow-up of PTLD. The clinical relevance of including FDG-PET/CT scanning in the management of PTLD should be evaluated in a larger prospective cohort study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background¦Erythrocyte MCV might be used as an inexpensive marker to predict and¦optimize the efficacy and tolerability of thiopurine therapy in IBD patients.¦Aim and methods¦This retrospective observational study aimed to assess the monitoring¦performances of MCV in patients under 3 months or more thiopurine treatment followed up¦in the Swiss IBD Cohort Study. All available MCV, white blood cells (WBC) and 6¦thioguanine nucleotide (6TGN) measurements, among others, were recorded. An IBD¦"flare" was defined as a composite outcome encompassing treatment change,¦colonoscopy, histology, CT scan or MRI reports showing active IBD lesions, occurrence of¦intestinal surgery and IBD-related hospitalisations. Whether MCV measurements predicted¦efficacy of thiopurine treatment was investigated by assessing the statistical association¦between the occurrence of IBD "flares", and the current or recent MCV values, taking into¦account the patient clustering and longitudinal aspect of data.¦Results¦140 patients (77 women), mean age 38 years (17-74), 104 diagnosed with¦Crohn's disease, 36 with ulcerative colitis, mean disease duration 8 years (0.25-36),¦receiving either azathioprine (n=125) or 6-mercaptopurine (n=15) were included, most of¦them over 3-year follow up.¦Thiopurines increased mean patient MCV by an average 5.8±5.2 fL, while¦patientsfluctuated by ±4.3 fL around their individual mean (p<0.001). They decreased¦WBC by an average of 2.4+/- 2.6 G/L (p<0.001).¦Significant associations were observed between the probability of flare occurrence and low¦current MVC (p=0.017) or high current WBC (p=0.009) and, with a relative risk of 3.7% for¦every fL of MCV decrease or 8% for every G/L of WBC increase. Both markers revealed¦some memory effect.¦Despite this, the performance of MCV and WBC to predict IBD "flare" remained rather¦limited, as it is less accurate than the 6-TGN-level , although only determined in a¦subgroup of patients in this study.¦Conclusion¦MCV and WBC deserve to be observed to check and monitor therapeutic¦exposure to thiopurine agents in IBD patients. Unfortunately, their predictive performance¦precludes their privileged use for optimization of therapy. Further prospective studies¦should suitably include the systematic measurement of metabolite concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Colonoscopy is generally performed with the patient sedated and receiving analgesics. However, the benefit of the most often used combination of intravenous midazolam and pethidine on patient tolerance and pain and its cardiorespiratory risk have not been fully defined. METHODS: In this double-blind prospective study, 150 outpatients undergoing routine colonoscopy were randomly assigned to receive either (1) low-dose midazolam (35 micrograms/kg) and pethidine (700 micrograms/kg in 48 patients, 500 micrograms/kg in 102 patients), (2) midazolam and placebo pethidine, or (3) pethidine and placebo midazolam. RESULTS: Tolerance (visual analog scale, 0 to 100 points: 0 = excellent; 100 = unbearable) did not improve significantly more in group 1 compared with group 2 (7 points; 95% confidence interval [-2-17]) and group 3 (2 points; 95% confidence interval [-7-12]). Similarly, pain was not significantly improved in group 1 as compared with the other groups. Male gender (p < 0.001) and shorter duration of the procedure (p = 0.004), but not amnesia, were associated with better patient tolerance and less pain. Patient satisfaction was similar in all groups. Oxygen desaturation and hypotension occurred in 33% and 11%, respectively, with a similar frequency in all three groups. CONCLUSIONS: In this study, the combination of low-dose midazolam and pethidine does not improve patient tolerance and lessen pain during colonoscopy as compared with either drug given alone. When applying low-dose midazolam, oxygen desaturation and hypotension do not occur more often after combined use of both drugs. For the individual patient, sedation and analgesia should be based on the endoscopist's clinical judgement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUM Com a continuació del treball de final de carrera “Desenvolupament d’un laboratori virtual per a les pràctiques de Biologia Molecular” de Jordi Romero, s’ha realitzat una eina complementaria per a la visualització de molècules integrada en el propi laboratori virtual. Es tracta d’una eina per a la visualització gràfica de gens, ORF, marques i seqüències de restricció de molècules reals o fictícies. El fet de poder treballar amb molècules fictícies és la gran avantatge respecte a les solucions com GENBANK que només permet treballar amb molècules pròpies. Treballar amb molècules fictícies fa que sigui una solució ideal per a l’ensenyament, ja que dóna la possibilitat als professors de realitzar exercicis o demostracions amb molècules reals o dissenyades expressament per a l’exercici a demostrar. A més, permet mostrar de forma visual les diferents parts simultàniament o per separat, de manera que ofereix una primera aproximació interpretació dels resultats. Per altra banda, permet marcar gens, crear marques, localitzar seqüències de restricció i generar els ORF de la molècula que nosaltres creem o modificar una ja existent. Per l’implementació, s’ha continuat amb l’idea de separar la part de codi i la part de disseny en les aplicacions Flash. Per fer-ho, s’ha utilitzat la plataforma de codi lliure Ariware ARPv2.02 que proposa un marc de desenvolupament d’aplicacions Flash orientades a objectes amb el codi (classes ActionScript 2.0) separats del movieclip. Per al processament de dades s’ha fet servir Perl per ser altament utilitzat en Bioinformàtica i per velocitat de càlcul. Les dades generades es guarden en una Base de Dades en MYSQL (de lliure distribució), de la que s’extreuen les dades per generar fitxers XML, fent servir tant PHP com la plataforma AMFPHP com a enllaç entre Flash i la resta de parts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’augment de la utilització de les noves tecnologies a la nostra societat permet a les empreses arribar al client d’una forma més rapida i facilitant la informació de manera àgil i ordenada. Amb aquest objectiu s’ha creat una botiga virtual que serà la part visible als usuaris i clients de l’empresa PRINTONER S.L , dedicada al sector dels consumibles, especialment els reciclats. Per l’empresa un dels objectius principals és oferir al client la possibilitat de comprar els seus productes de manera còmode a través d’Internet, ja que accedint amb un nom d’usuari i una contrasenya podrà obtenir totes les referències de les que es disposa, podrà tramitar les comandes i controlar-ne l’estat fins el moment de l’entrega. A part de les seccions destinades a usuaris i clients s’ha creat una zona d’administració, on els responsables de l’empresa podran gestionar tots els productes, modificar i visualitzar les comandes. A més aprofitant que aquestes quedaran guardades a una base de dades juntament amb els productes venuts, s’integrarà el sistema de facturació de l’empresa, cosa que fins el moment es feia de manera manual i maldestre. També es programarà una part on els responsables podran insertar reparacions i vendes informàtiques que s’hagin de facturar o per fer-ne un us estadístic en un futur. Tot això ens portarà a implementar un sistema d’usuaris registrats amb diferents permisos i diferents nivells d’accés a l’aplicació, fins a un total de 5. S’ha intentat fer de l’aplicació, un sistema a mida i que compleixi tots els requisits que l’empresa ens ha demanat, amb la previsió que més endavant s’hi pugui implementar un sistema de gestió d’estocs i altres millores per oferir als seus clients un servei inigualable. Per tal de portar a terme tot aquest treball s’ha utilitzat una tecnologia de lliure distribució com és el llenguatge PHP i la base de dades MySQL, aquesta opció a part d’una filosofia es produeix per intentar minimitzar els costos de l’aplicatiu. La finalitat de l’empresa amb aquest projecte és oferir millor imatge i servei, efectivitat i rapidesa en tot el procés de vendes, així com reduir costos de facturació i també de publicitat, ja que es podrà potenciar molt més la pàgina web via internet.