932 resultados para COMPUTED-TOMOGRAPHY
Resumo:
The trans-apical aortic valve implantation (TA-AVI) is an established technique for high-risk patients requiring aortic valve replacement. Traditionally, preoperative (computed tomography (CT) scan, coronary angiogram) and intra-operative imaging (fluoroscopy) for stent-valve positioning and implantation require contrast medium injections. To preserve the renal function in elderly patients suffering from chronic renal insufficiency, a fully echo-guided trans-catheter valve implantation seems to be a reasonable alternative. We report the first successful TA-AVI procedure performed solely under trans-oesophageal echocardiogram control, in the absence of contrast medium injections.
Resumo:
BACKGROUND: Acute treatment of ischemic stroke patients presenting more than eight-hours after symptom onset remains limited and largely unproven. Partial aortic occlusion using the NeuroFlo catheter can augment cerebral perfusion in animals. We investigated the safety and feasibility of employing this novel catheter to treat ischemic stroke patients eight-hours to 24 h following symptom onset. METHODS: A multicenter, single-arm trial enrolled ischemic stroke patients at nine international academic medical centers. Eligibility included age 18-85 years old, National Institutes of Health stroke scale (NIHSS) score between four and 20, within eight-hours to 24 h after symptom onset, and perfusion-diffusion mismatch confirmed by magnetic resonance imaging. The primary outcome was all adverse events occurring from baseline to 30 days posttreatment. Secondary outcomes included stroke severity on neurological indices through 90 days. This study is registered with ClinicalTrials.gov, number NCT00436592. RESULTS: A total of 26 patients were enrolled. Of these, 25 received treatment (one excluded due to aortic morphology); five (20%) died. Favorable neurological outcome at 90 days (modified Rankin score 0-2 vs. 3-6) was associated with lower baseline NIHSS (P < 0·001) and with longer duration from symptom discovery to treatment. There were no symptomatic intracranial hemorrhages or parenchymal hematomas. Asymptomatic intracranial hemorrhage was visible on computed tomography in 32% and only on microbleed in another 20%. CONCLUSIONS: Partial aortic occlusion using the NeuroFlo catheter, a novel collateral therapeutic strategy, appears safe and feasible in stroke patients eight-hours to 24 h after symptom onset.
Resumo:
In population surveys of the exposure to medical X-rays both the frequency of examinations and the effective dose per examination are required. The use of the Swiss medical tariffication system (TARMED) for establishing the frequency of X-ray medical examinations was explored. The method was tested for radiography examinations performed in 2008 at the Lausanne University Hospital. The annual numbers of radiographies determined from the "TARMED" database are in good agreement with the figures extracted from the local RIS (Radiology Information System). The "TARMED" is a reliable and fast method for establishing the frequency of radiography examination, if we respect the context in which the "TARMED" code is used. In addition, this billing context provides most valuable information on the average number of radiographs per examination as well as the age and sex distributions. Radiographies represent the major part of X-ray examinations and are performed by about 4,000 practices and hospitals in Switzerland. Therefore this method has the potential to drastically simplify the organisation of nationwide surveys. There are still some difficulties to overcome if the method is to be used to assess the frequency of computed tomography or fluoroscopy examinations; procedures that deliver most of the radiation dose to the population. This is due to the poor specificity of "TARMED" codes concerning these modalities. However, the use of CT and fluoroscopy installations is easier to monitor using conventional survey methods since there are fewer centres. Ways to overcome the "TARMED" limitations for these two modalities are still being explored.
Resumo:
HYPOTHESIS: During total shoulder arthroplasty (TSA), humeral head subluxation may be difficult to manage. Furthermore, there is a risk for postoperative recurrence of subluxation, affecting the outcome of TSA. An accurate evaluation of the subluxation is necessary to evaluate this risk. Currently, subluxation is measured in 2 dimensions (2D), usually relative to the glenoid face. The goal of this study was to extend this measure to 3 dimensions (3D) to compare glenohumeral and scapulohumeral subluxation and to evaluate the association of subluxation with the glenoid version. MATERIALS AND METHODS: The study analyzed 112 computed tomography scans of osteoarthritic shoulders. We extended the usual 2D definition of glenohumeral subluxation, scapulohumeral subluxation, and glenoid version by measuring their orientation in 3D relative to the scapular plane and the scapular axis. We evaluated statistical associations between subluxation and version in 2D and 3D. RESULTS: Orientation of subluxation and version covered all sectors of the glenoid surface. Scapulohumeral subluxation and glenoid version were highly correlated in amplitude (R(2) = 0.71; P < .01) and in orientation (R(2) = 0.86; P < .01). Approximately every degree of glenoid version induced 1% of scapulohumeral subluxation in the same orientation of the version. Conversely, glenohumeral subluxation was not correlated to glenoid version in 2D or in 3D. CONCLUSIONS: Orientation of the humeral subluxation is rarely within the arbitrary computed tomography plane and should therefore be measured in 3D to detect out-of-plane subluxation. Scapulohumeral subluxation and glenoid version measured in 3D could bring valuable information for decision making during TSA.
Resumo:
Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection. The last survey in Switzerland was conducted in 1998, and the annual effective dose from medical radiology was estimated to be 1 mSv y(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database (www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.
Resumo:
PURPOSE: To investigate current practices and timing of neurological prognostication in comatose cardiac arrest patients. METHODS: An anonymous questionnaire was distributed to the 8000 members of the European Society of Intensive Care Medicine during September and October 2012. The survey had 27 questions divided into three categories: background data, clinical data, decision-making and consequences. RESULTS: A total of 1025 respondents (13%) answered the survey with complete forms in more than 90%. Twenty per cent of respondents practiced outside of Europe. Overall, 22% answered that they had national recommendations, with the highest percentage in the Netherlands (>80%). Eighty-nine per cent used induced hypothermia (32-34 °C) for comatose cardiac arrest patients, while 11% did not. Twenty per cent had separate prognostication protocols for hypothermia patients. Seventy-nine per cent recognized that neurological examination alone is not enough to predict outcome and a similar number (76%) used additional methods. Intermittent electroencephalography (EEG), brain computed tomography (CT) scan and evoked potentials (EP) were considered most useful. Poor prognosis was defined as cerebral performance category (CPC) 3-5 (58%) or CPC 4-5 (39%) or other (3%). When prognosis was considered poor, 73% would actively withdraw intensive care while 20% would not and 7% were uncertain. CONCLUSION: National recommendations for neurological prognostication after cardiac arrest are uncommon and only one physician out of five uses a separate protocol for hypothermia treated patients. A neurological examination alone was considered insufficient to predict outcome in comatose patients and most respondents advocated a multimodal approach: EEG, brain CT and EP were considered most useful. Uncertainty regarding neurological prognostication and decisions on level of care was substantial.
Resumo:
BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.
Resumo:
The application of contrast media in post-mortem radiology differs from clinical approaches in living patients. Post-mortem changes in the vascular system and the absence of blood flow lead to specific problems that have to be considered for the performance of post-mortem angiography. In addition, interpreting the images is challenging due to technique-related and post-mortem artefacts that have to be known and that are specific for each applied technique. Although the idea of injecting contrast media is old, classic methods are not simply transferable to modern radiological techniques in forensic medicine, as they are mostly dedicated to single-organ studies or applicable only shortly after death. With the introduction of modern imaging techniques, such as post-mortem computed tomography (PMCT) and post-mortem magnetic resonance (PMMR), to forensic death investigations, intensive research started to explore their advantages and limitations compared to conventional autopsy. PMCT has already become a routine investigation in several centres, and different techniques have been developed to better visualise the vascular system and organ parenchyma in PMCT. In contrast, the use of PMMR is still limited due to practical issues, and research is now starting in the field of PMMR angiography. This article gives an overview of the problems in post-mortem contrast media application, the various classic and modern techniques, and the issues to consider by using different media.
Resumo:
PRINCIPLES: To assess the efficiency and complication rates of vaso-occlusion of pulmonary arteriovenous malformations (PAVMs) in Rendu-Osler-Weber disease (hereditary haemorrhagic telangectasia; HHT). METHODS: Seventy-two patients were investigated in our institution for HHT between March 2000 and November 2011. Sixteen presented PAVMs (22.2%), and 11 (68.8%) were treated with vaso-occlusion for a total of 18 procedures. Procedures included coils, plugs and combined approaches. Immediate success and recurrence rate, complication were recorded, as well as persistent and new PAVMs during clinical and computed tomography (CT) follow-up. RESULTS: Eighteen procedures were performed and a total of 37 PAVMs were treated, 19 with coils, 16 with plugs and 2 with combined treatment. Mean CT follow-up time was 41 months (1‒164). No major complication was observed. One distal translocation was treated during the same intervention. Two PAVMs persisted after treatment (5.7%), both treated by means of plug embolisation. One new PAVM was observed during follow-up CT. PAVMs with an afferent artery of less than 3mm or asymptomatic PAVMs were not treated. CONCLUSION: Recent studies have demonstrated that vaso-occlusion has become the gold standard treatment for PAVM. This study is in accordance with previous results and shows a minimal complication rate and little recurrence, whether by coils, plugs, or combined treatments.
Resumo:
While the overall incidence of myocardial infarction (MI) has been decreasing since 2000 [1], there is an increasing number of younger patients presenting with MI [2]. Few studies have focused on MI in very young patients, aged 35 years or less, as they only account for a minority of all patients with myocardial infarction [3]. According to the age category, MI differs in presentation, treatment and outcome, as illustrated in table 1. Echocardiography is considered mandatory according to scientific guidelines in the management and diagnosis of MI [4,5,6]. However, new imaging techniques such as cardiac magnetic resonance (CMR) and computed tomography (CT) are increasingly performed and enable further refinement of the diagnosis of MI. These techniques allow, in particular, precise location and quantification of MI. In this case, MI was located to the septum, which is an unusual presentation of MI. The incidence of pulmonary embolism (PE) has also increased in young patients over the past years [7]. Since symptoms and signs of PE may be non-specific, establishing its diagnosis remains a challenge [8]. Therefore, PE is one of the most frequently missed diagnosis in clinical medicine. Because of the widespread use of CT and its improved visualization of pulmonary arteries, PE may be discovered incidentally [9]. In the absence of a congenital disorder, multiple and/or simultaneous disease presentation is uncommon in the young. We report the rare case of a 35 year old male with isolated septal MI and simultaneous PE. The diagnosis of this rare clinical entity was only possible by means of newer imaging techniques.
Resumo:
This thesis describes an ancillary project to the Early Diagnosis of Mesothelioma and Lung Cancer in Prior Asbestos Workers study and was conducted to determine the effects of asbestos exposure, pulmonary function and cigarette smoking in the prediction of pulmonary fibrosis. 613 workers who were occupationally exposed to asbestos for an average of 25.9 (SD=14.69) years were sampled from Sarnia, Ontario. A structured questionnaire was administered during a face-to-face interview along with a low-dose computed tomography (LDCT) of the thorax. Of them, 65 workers (10.7%, 95%CI 8.12—12.24) had LDCT-detected pulmonary fibrosis. The model predicting fibrosis included the variables age, smoking (dichotomized), post FVC % splines and post- FEV1% splines. This model had a receiver operator characteristic area under the curve of 0.738. The calibration of the model was evaluated with R statistical program and the bootstrap optimism-corrected calibration slope was 0.692. Thus, our model demonstrated moderate predictive performance.
Resumo:
Objectifs: Évaluer si un programme d’entraînement en résistance d’une durée d’un an prévient le regain de poids et majore l’amélioration du profil inflammatoire. Le second objectif de cette étude était de déterminer si la variation du tissu adipeux viscéral est associée aux changements dans les concentrations sanguines des marqueurs inflammatoires. Méthodes: Soixante-dix femmes post-ménopausées en surpoids ou obèses ont été randomisées dans un des deux groupes suivants : (1) Contrôle ou (2) Entraînement en résistance. La composition corporelle (absorptiométrie double à rayons X et tomographie axiale) et les marqueurs inflammatoires (protéine C-réactive, orosomucoïde, haptoglobine) ont été évalués avant et après la période de suivi d’une durée d’un an. Résultats: Suite à la période de suivi, un regain significatif de poids corporel et de masse grasse était observé dans le groupe contrôle et le groupe entraînement en résistance (p < 0,05). Une réduction des concentrations sériques de l’orosomucoïde et une hausse des niveaux sériques de l’haptoglobine étaient également notées dans les deux groupes (p < 0,05). La variation du tissu adipeux viscéral était seulement associée aux changements dans les concentrations sériques de la protéine C-réactive (r = 0,373, p < 0,05). Conclusion: Nos résultats suggèrent que l’entraînement en résistance ne prévient pas le regain de poids corporel et ne majore pas l’amélioration du profil inflammatoire chez des femmes post-ménopausées en surpoids ou obèses. De plus, nos résultats indiquent que la variation du tissu adipeux viscéral ne semble pas être un facteur clé impliqué dans les changements des concentrations sanguines des marqueurs inflammatoires.
Resumo:
Introduction : L’expansion palatine rapide assistée chirurgicalement (EPRAC) est une option de traitement privilégiée chez les patients ayant atteint la maturité squelettique et présentant une déficience transverse du maxillaire. L’effet bénéfique de l’EPRAC sur la fonction respiratoire est régulièrement mentionné, toutefois, encore peu d’études ont évalué son impact sur les voies aériennes supérieures. L’objectif de cette étude clinique prospective comparative consistait à évaluer les effets tridimensionnels de l’EPRAC sur la cavité nasale, le nasopharynx et l’oropharynx à l’aide de la tomodensitométrie. Méthodologie : L’échantillon était constitué de 14 patients (5 hommes, 9 femmes) dont l’âge moyen était de 23,0 ± 1,9 ans (16 ans 4 mois à 39 ans 7 mois). Tous ont été traités avec un appareil d’expansion de type Hyrax collé et l’expansion moyenne a été de 9,82 mm (7,5 - 12,0 mm). Tous ont eu une période de contention d’une année avant le début de tout autre traitement orthodontique. Une évaluation par tomodensitométrie volumique à faisceau conique a été réalisée aux temps T0 (initial), T1 (6 mois post-expansion) et T2 (1an post-expansion) et le volume des fosses nasales, du nasopharynx et de l’oropharynx ainsi que les dimensions de la zone de constriction maximale de l’oropharynx ont été mesurés sur les volumes tridimensionnels obtenus. Résultats : Les résultats radiologiques ont démontré une augmentation significative du volume des fosses nasales et du nasopharynx ainsi qu’une augmentation de la zone de constriction maximale de l’oropharynx à 6 mois post-expansion. Par la suite, une portion du gain enregistré pour ces trois paramètres était perdue à un an post-EPRAC sans toutefois retourner aux valeurs initiales. Aucun effet significatif sur le volume de l’oropharynx n’a été observé. De plus, aucune corrélation significative entre la quantité d’expansion réalisée et l’ensemble des données radiologiques n’a été observée. L’analyse de la corrélation intra-classe a démontré une excellente fiabilité intra-examinateur. Conclusions : L’EPRAC entraîne un changement significatif du volume de la cavité nasale et du nasopharynx. L’EPRAC ne modifie pas le volume de l’oropharynx, par contre, un effet significatif sur la zone de constriction maximale de l’oropharynx est noté. Les effets observés n’ont pas de corrélation avec le montant d’activation de la vis d’expansion.
Resumo:
L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5).
Resumo:
Présentement, le diagnostic d’otite moyenne-interne chez le veau est basé sur la présence de signes cliniques appropriés ainsi que les tests diagnostiques tels que la radiographie et la tomodensitométrie. L’objectif de cette étude prospective était d’évaluer les valeurs prédictives de l’examen neurologique, l’examen otoscopique et le test des potentiels auditifs évoqués (PAE) dans le diagnostic d’otite moyenne-interne chez le veau, en utilisant la tomodensitométrie comme test standard. Le deuxième objectif était de définir les valeurs de référence pour le PAE chez le veau normal et d’en décrire les anomalies chez des veaux atteints d’otite moyenne-interne. Dix-sept veaux de race Holstein entre 5-7 semaines d’âge ont été inclus. Tous les veaux ont eu un examen neurologique, un examen otoscopique et une évaluation des PAEs. Les veaux ont été tranquillisés avec de la xylazine intraveineuse (0,05-0,15mg/kg) pour la tomodensitométrie des bulles tympaniques afin d’évaluer pour la présence d’otite moyenne-interne. Selon les résultats de la tomodensitométrie, 11 des 17 veaux étaient atteints avec otite moyenne, 4 de façon unilatérale et 7 bilatéralement. Cinq ondes ont été identifiées de façon constante sur les tracés des PAEs des 6 veaux normaux. Les valeurs positives prédictives pour le PAE, l’examen neurologique et l’examen otoscopique étaient 94,7%, 91,7% et 66,7% respectivement. D’un point de vue clinique, le test le plus fiable dans le diagnostic d’otite moyenne-interne chez le veau est le PAE. Les anomalies ont été observées au PAE avant le développement des signes neurologiques chez certains veaux.