922 resultados para Cálculo das variações
Resumo:
Radiotherapy in veterinary practice is already known and widely distributed in large specialized centers of developed countries. In early 2000, there were about 30 radiotherapy equipment specifically designed for the veterinary clinic in the United States. In Brazil, the veterinary radiotherapy is still confined to research in universities, where most of the procedures is radiation therapy performed with superficial x-ray machines, with a voltage between 50 and 150 kVp, focus-distance surface (DFS) between 20,0cm and 40,0cm. As that occurs in human medicine, new research strengthens the development and prospects for the use of radiotherapy as a safe option for treating cancer in animals. This paper presents a methodology for calculating the exposure time for superficial radiotherapy procedures in veterinary medicine for small animals (dogs and cats). The dosimetric parameters of X-rays are determined using a spreadsheet tool for Microsoft Office Excel, developed in this paper for a device Dermopan 2, Veterinary Hospital of UNESP in Araçatuba. Using the worksheet helps the veterinarian to determine the time of exposure to radiation determined for each clinical case, optimize the workflow for professionals in veterinary radiotherapy procedures, which often lack the medical physics in team and at the time of radiotherapy. The correct use of spreadsheet decreases the chances of errors in dose rates of radiation, providing a higher quality of care
Resumo:
This work aims to study several diffusive regimes, especially Brownian motion. We deal with problems involving anomalous diffusion using the method of fractional derivatives and fractional integrals. We introduce concepts of fractional calculus and apply it to the generalized Langevin equation. Through the fractional Laplace transform we calculate the values of diffusion coefficients for two super diffusive cases, verifying the validity of the method
Resumo:
In radiation theraphy with electron beam, the electrons are produced in linear accelerators, and energy the most used have between 4MeV and 20MeV. Generally, the treatments are done for superficial injuries, because the low penetration of these particles. In this work a system for calculation of monitor units (U.M.) for cases of treatments with electron beam was developed. The Excel program of Microsoft was used and is easily found in the operational system of the personal microcomputers. In the Excel has been inserted the pertinent data of the linear accelerator of Varian, model 2100C, used in the Service of radiation theraphy of the Hospital of the Clinics of the College of Medicine of the UNESP of Botucatu. For some values of the physical parameters, such as: factors field and factors calibration, not supplied in the tests of acceptance of the machine, still proceeded calculations from interpolation and extrapolation. The mathematical formulas for automatic search of these and others factors used in the calculations of the determination of the U.M had been developed in agreement available routines in Excel. For this the functions had been used the function IF (that it imposes search condition) and the PROCH (that looks a value in a column from determined line), beyond the basic functions of addition, multiplication and division. It is intended to optimize the routine of the Services of radiation theraphy that perform through eletrontheraphy procedures, speeding the calculations and minimizing the occurrence of errors and uncertainties deriving of the maken a mistake manipulation of the parameters gotten in tables of data of electron beams
Resumo:
This study aimed to develop a computer program which systematizes the structural shielding design calculation in diagnostic radiology facilities. For this purpose methodology of the National Council of Radiation Protection and Measurements (NCRP 147[5]) was used. By comparative statistics studies, it was verified if reference parameters values suggested by the US publication correspond to the average national values. The World Wide Web was chosen because of its characteristics as a powerful mean of communication, especially in terms of the wide variety of useful resources and easy access. To compare the reference values of some parameters proposed by NCRP 147 to Brazilian average, studies about the normalized workload per patient, performance of X-ray tube and primary air kerma, unshielded, at one meter from the focal point of the X-ray tube were made. Through this research, relative differences were found. In workload values this differences reached up to 50% in mammography compared to those presented by the NCRP 147; in X-ray tube performance the percentage differences reached 69% in dental radiology, and air kerma results amounted 31% in fluoroscopy. This demonstrates the importance of validation of international protocols to local realities
Resumo:
Geophysics studies in areas impacted by petroleum derivatives describe abnormalities of both low and high electrical resistivity (the opposite of electrical conductivity), confirmed as contaminant phase by chemical analysis: this contradiction can be explained by degrading processes that naturally occur and create sub products that can change the environment conductivity. Monitoring the variation of the parameters mentioned serves as a comparative basis to the variation in geoelectrical parameters, which identified the correlation between the same contaminant parameters and the difference between their behavior studied apart, as well as its relations with the biodegradation process. The results are applied to the fuel distribution and storage sectors, leading to the diagnosis and monitoring of possible groundwater contamination scenarios, and the knowledge of the area exposure time to the contaminant, besides the better remediation alternative and impacts control. Among some conclusions, the most significant are the decrease in conductivity over time, so as the increase in Eh value in the gasoline contaminated tank, as well as the decrease in the pH value in the second tank with ethanol, which can be attributed to its degradation. Comparing the variations in both tanks, it is evident that Eh, pH and electrical conductivity do not behave temporally in a similar way, although some correlations between Eh and pH can be related.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work studies the most commonly used methods and make comparisons and discussions of the findings made by each of them and the results provided by them. The objective of this research was to show that the method of characteristics is currently the most efficient method to perform these simulations because of its broad scope low simplifications, requirement allowing to consider every detail of the pipe and fluid. Manual calculations are performed and also a software capable of calculating this phenomenon for various situations, such as water pump, elevated tanks, valves and quick maneuver was developed. The software is based on the method of characteristics that is currently recommended by ABNT. These methods, and the results are obtained numerically and graphically are adopted pipes and amount of downstream conditions and in which will be applied. The conclusions reached showed that the Allievi method is widely used yet because of its efficiency and quick calculation for simple pipes. The method of characteristics, although a lot of work to be calculated due to the calculation is iterative process and requires a program to use it, is the only one that allows the calculation with all amount to the conditions situations and downstream of all the pipe possibilities found
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this work was the study of numerical methods for differential equations of fractional order and ordinary. These methods were applied to the problem of calculating the distribution of the concentration of a given substance over time in a given physical system. The two compartment model was used for representation of this system. Comparison between numerical solutions obtained were performed and, in particular, also compared with the analytical solution of this problem. Finally, estimates for the error between the solutions were calculated
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Educação - FFC
Resumo:
This article reports on the diversity and the linguistic variations in e-mails and chat interactions in teletandem interactions. Based on the interface of foreign language acquisition and sociolinguistics, its focus is on linguistic variants under the perspective of the social variations of language, especially regarding standard and non-standard norms of the Portuguese language in a teletandem context. Sociolinguistics offers us resources for the analysis and understanding that we intend to provide about teletandem interactions. We also mention the Teletandem Brasil project, its ideas and theoretical orientations, and also analyze data collected. The findings show that the variations in foreign students´ written production, who are also Portuguese learners, come from fluctuations between the standard and non-standard norms because students still do not have complete communicative competence in the target language.
Resumo:
The work presented here aims to evaluate how aesthetic norm variations influence the perception of attractiveness of a smile according to dentists and laymen. Methods: The smiles in photographs of a man and a woman were digitally changed. Eleven smiles were created for each one: an ideal, control smile - an ideal smile according to accepted norms - and 10 smiles containing individual variations of each of the following norms: a) 2mm and 3mm deviations from the middle line; b) the contour of the smile - contour of a straight smile and contour of a reverse smile; c) the angle of the lateral incisors - a mesial angle of 10° and a distal angle of 10°; d) 0.5mm and 1mm diastema; and e) dental proportion - Alber’s Proportion and Plato’s Proportion. The photographs were evaluated by two specialists in cosmetic dentistry and two laymen using the visual analogue scale. Results: The ideal smile for both genders was well accepted by both the specialists and the laymen. The opinions on the smiles with aesthetic variations varied, some were more positive than others, some were in agreement and some were in disagreement. Conclusion: The absence of deviations favors the perceived beauty of a smile, but some aesthetic variations seem to be better accepted than others. The success of aesthetic treatments depends on the active participation of dentists and patients in the planning stage.