875 resultados para Building energy simulations
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
The performance of the Weather Research and Forecast (WRF) model in wind simulation was evaluated under different numerical and physical options for an area of Portugal, located in complex terrain and characterized by its significant wind energy resource. The grid nudging and integration time of the simulations were the tested numerical options. Since the goal is to simulate the near-surface wind, the physical parameterization schemes regarding the boundary layer were the ones under evaluation. Also, the influences of the local terrain complexity and simulation domain resolution on the model results were also studied. Data from three wind measuring stations located within the chosen area were compared with the model results, in terms of Root Mean Square Error, Standard Deviation Error and Bias. Wind speed histograms, occurrences and energy wind roses were also used for model evaluation. Globally, the model accurately reproduced the local wind regime, despite a significant underestimation of the wind speed. The wind direction is reasonably simulated by the model especially in wind regimes where there is a clear dominant sector, but in the presence of low wind speeds the characterization of the wind direction (observed and simulated) is very subjective and led to higher deviations between simulations and observations. Within the tested options, results show that the use of grid nudging in simulations that should not exceed an integration time of 2 days is the best numerical configuration, and the parameterization set composed by the physical schemes MM5–Yonsei University–Noah are the most suitable for this site. Results were poorer in sites with higher terrain complexity, mainly due to limitations of the terrain data supplied to the model. The increase of the simulation domain resolution alone is not enough to significantly improve the model performance. Results suggest that error minimization in the wind simulation can be achieved by testing and choosing a suitable numerical and physical configuration for the region of interest together with the use of high resolution terrain data, if available.
Resumo:
In this work a mixed integer optimization linear programming (MILP) model was applied to mixed line rate (MLR) IP over WDM and IP over OTN over WDM (with and without OTN grooming) networks, with aim to reduce network energy consumption. Energy-aware and energy-aware & short-path routing techniques were used. Simulations were made based on a real network topology as well as on forecasts of traffic matrix based on statistical data from 2005 up to 2017. Energy aware routing optimization model on IPoWDM network, showed the lowest energy consumption along all years, and once compared with energy-aware & short-path routing, has led to an overall reduction in energy consumption up to 29%, expecting to save even more than shortest-path routing. © 2014 IEEE.
Resumo:
Consolidation consists in scheduling multiple virtual machines onto fewer servers in order to improve resource utilization and to reduce operational costs due to power consumption. However, virtualization technologies do not offer performance isolation, causing applications’ slowdown. In this work, we propose a performance enforcing mechanism, composed of a slowdown estimator, and a interference- and power-aware scheduling algorithm. The slowdown estimator determines, based on noisy slowdown data samples obtained from state-of-the-art slowdown meters, if tasks will complete within their deadlines, invoking the scheduling algorithm if needed. When invoked, the scheduling algorithm builds performance and power aware virtual clusters to successfully execute the tasks. We conduct simulations injecting synthetic jobs which characteristics follow the last version of the Google Cloud tracelogs. The results indicate that our strategy can be efficiently integrated with state-of-the-art slowdown meters to fulfil contracted SLAs in real-world environments, while reducing operational costs in about 12%.
Resumo:
Energy consumption is one of the major issues for modern embedded systems. Early, power saving approaches mainly focused on dynamic power dissipation, while neglecting the static (leakage) energy consumption. However, technology improvements resulted in a case where static power dissipation increasingly dominates. Addressing this issue, hardware vendors have equipped modern processors with several sleep states. We propose a set of leakage-aware energy management approaches that reduce the energy consumption of embedded real-time systems while respecting the real-time constraints. Our algorithms are based on the race-to-halt strategy that tends to run the system at top speed with an aim to create long idle intervals, which are used to deploy a sleep state. The effectiveness of our algorithms is illustrated with an extensive set of simulations that show an improvement of up to 8% reduction in energy consumption over existing work at high utilization. The complexity of our algorithms is smaller when compared to state-of-the-art algorithms. We also eliminate assumptions made in the related work that restrict the practical application of the respective algorithms. Moreover, a novel study about the relation between the use of sleep intervals and the number of pre-emptions is also presented utilizing a large set of simulation results, where our algorithms reduce the experienced number of pre-emptions in all cases. Our results show that sleep states in general can save up to 30% of the overall number of pre-emptions when compared to the sleep-agnostic earliest-deadline-first algorithm.
Resumo:
Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.
Resumo:
Dado o panorama de conservação de energia a nível nacional e mundial, torna-se hoje em dia muito importante, que seja possível controlar e estimar o consumo energético nos edifícios. Assim, atendendo à actual problemática energética e ao crescente consumo energético nos edifícios, é importante parametrizar, avaliar e comparar este consumo. Neste sentido, nas últimas décadas, têm sido efectuados desenvolvimentos técnicos, quer ao nível do equipamento de campo para efectuar monitorização e medição, quer ao nível da simulação dinâmica de edifícios. Com esta dissertação de mestrado, pretendeu-se efectuar a simulação dinâmica de um edifício escolar existente a funcionar em pleno, e efectuar uma análise de sensibilidade relativamente ao grau de variação dos resultados obtidos através da aplicação de dois programas de cálculo térmico e energético. Foram utilizados, o programa VE-Pro da IES (Integrated Environmental Solutions) e o programa Trace 700 da TRANE. Ambos os programas foram parametrizados com os mesmos dados de entrada, tendo em atenção as opções de simulação disponibilizadas por ambos. Posteriormente, utilizaram-se os dados retirados da simulação para calcular a classificação energética no âmbito do sistema de certificação energética (SCE), através de uma folha de cálculo desenvolvida para o efeito. Foram ainda consideradas várias soluções de eficiência energética para o edifício, com vista a poupanças reais de energia, tendo sempre atenção ao conforto térmico dos ocupantes. Dessas medidas fazem parte, medidas relacionadas com a iluminação, como a substituição da iluminação existente por luminárias do tipo LED (Light Emitting Diode), soluções de energias renováveis, como a instalação de colectores solares para aquecimento das águas quentes sanitárias, e painéis fotovoltaicos para produção de energia, bem como medidas ligadas aos equipamentos de climatização. Posteriormente, recalculou-se a classificação energética afectada das melhorias. Os resultados obtidos nas duas simulações foram analisados sob o ponto de vista do aquecimento, arrefecimento, ventilação, iluminação e equipamentos eléctricos. A comparação das duas simulações para cada parâmetro acima referido, apresentaram variações inferiores a 5%. O desvio maior verificou-se na ventilação, com o valor de aproximadamente 4,9%. Transpondo estes resultados para o cálculo do IEE (Índice de Eficiência Energética), verificou-se um desvio inferior a 2%.
Resumo:
Heterogeneous multicore platforms are becoming an interesting alternative for embedded computing systems with limited power supply as they can execute specific tasks in an efficient manner. Nonetheless, one of the main challenges of such platforms consists of optimising the energy consumption in the presence of temporal constraints. This paper addresses the problem of task-to-core allocation onto heterogeneous multicore platforms such that the overall energy consumption of the system is minimised. To this end, we propose a two-phase approach that considers both dynamic and leakage energy consumption: (i) the first phase allocates tasks to the cores such that the dynamic energy consumption is reduced; (ii) the second phase refines the allocation performed in the first phase in order to achieve better sleep states by trading off the dynamic energy consumption with the reduction in leakage energy consumption. This hybrid approach considers core frequency set-points, tasks energy consumption and sleep states of the cores to reduce the energy consumption of the system. Major value has been placed on a realistic power model which increases the practical relevance of the proposed approach. Finally, extensive simulations have been carried out to demonstrate the effectiveness of the proposed algorithm. In the best-case, savings up to 18% of energy are reached over the first fit algorithm, which has shown, in previous works, to perform better than other bin-packing heuristics for the target heterogeneous multicore platform.
Resumo:
Neste trabalho estudou-se a nova regulamentação de térmica em edifícios, Decreto-Lei nº 118/2013, dando particular ênfase ao Regulamento de Desempenho Energético dos Edifícios de Habitação, REH. Para o efeito, aplicou-se a metodologia definida nesta legislação a um edifício de habitação unifamiliar e compararam-se os resultados obtidos com os resultados da ferramenta de cálculo automático elaborada pelo ITEcons. Fizeram-se ainda várias simulações para as diferentes zonas climáticas possíveis e comparou-se também com o mesmo edifício mas admitindo que todas as soluções construtivas são as de referência.
Resumo:
The reduction of greenhouse gas emissions is one of the big global challenges for the next decades due to its severe impact on the atmosphere that leads to a change in the climate and other environmental factors. One of the main sources of greenhouse gas is energy consumption, therefore a number of initiatives and calls for awareness and sustainability in energy use are issued among different types of institutional and organizations. The European Council adopted in 2007 energy and climate change objectives for 20% improvement until 2020. All European countries are required to use energy with more efficiency. Several steps could be conducted for energy reduction: understanding the buildings behavior through time, revealing the factors that influence the consumption, applying the right measurement for reduction and sustainability, visualizing the hidden connection between our daily habits impacts on the natural world and promoting to more sustainable life. Researchers have suggested that feedback visualization can effectively encourage conservation with energy reduction rate of 18%. Furthermore, researchers have contributed to the identification process of a set of factors which are very likely to influence consumption. Such as occupancy level, occupants behavior, environmental conditions, building thermal envelope, climate zones, etc. Nowadays, the amount of energy consumption at the university campuses are huge and it needs great effort to meet the reduction requested by European Council as well as the cost reduction. Thus, the present study was performed on the university buildings as a use case to: a. Investigate the most dynamic influence factors on energy consumption in campus; b. Implement prediction model for electricity consumption using different techniques, such as the traditional regression way and the alternative machine learning techniques; and c. Assist energy management by providing a real time energy feedback and visualization in campus for more awareness and better decision making. This methodology is implemented to the use case of University Jaume I (UJI), located in Castellon, Spain.
Resumo:
This work project takes the format of a problem-solving approach suggested by “Impulse Partners”, a French consulting firm. It recommends a way to measure the success of ten startups in the incubators “Starburst” and “Incubator Construction & Energy” and give them strategic guidance. A Balanced Scorecard is elaborated to help incubated startups building up and implementing their strategy. The Scorecard suggests possible initiatives for the startups that are ideally realized with the help of the consulting firm that is steering the incubator. Special attention is drawn to what the startups need to succeed, which typically concerns financing, networking and managing skills.
Resumo:
Manpower is a basic resource. It is the indispensable means of converting other resources to mankind '.s use and benefit. As a process· of increasing the knowledge, skills, and dexterity of the people of a society, manpower development is the most fundamental means of enabling a nation to acquire the capacities to bring about its desired future state of affairs -- a more mighty and wealthier nation. Singapore's brief nation-building history justifies the emphasis accorded to the importance of good quality human resources and manpower development in economic and socio-political developments. As a tiny island-state with a poor natural resource base, Singapore's long-term survival and development depend ultimately upon the quality and the creative energy of her people. In line with the nation-building goals and strategies of the Republic, as conditioned by her objective setting, Singapore's basic manpower development premise has been one of "quality and not quantity". While implementing the "stop-at-two" family planning and population control programs and the relevant immigration measures to guard against the prospect of a "population explosion", the Government has energetically fostered various educational programs, including vocational training schemes, adult education programs, the youth movement, and the national service scheme to improve the quality of Singaporeans. There is no denying that some of the manpower development measures taken by the Government have imposed sacrifice and hardship on the Singapore citizens. Nevertheless, they are the basic conditions for the island-Republic's long-term survival and development. It is essential iii to note that Singapore's continuing existence and phenomenal-success are largely attributable to the will, capacities and efforts of her leaders and people. In the final analysis, the wealth and the strength of a nation are based upon its ability to conserve, develop and utilize effectively the innate capacities of its people. This is true not only of Singapore but necessarily of other developing nations. It can be safely presumed that since most developing states' concerns about the quality of their human resources and the progress of their nation-building work are inextricably bound to those about the quantity of their population, the "quality and not quantity" motto of Singapore's manpower development programs can also be their guiding principle.
Détection des événements de "Minimum Bias" et neutrons avec les détecteurs ATLAS-MPX par simulations
Resumo:
Un réseau de seize détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Les détecteurs ATLAS-MPX sont sensibles au champ mixte de radiation de photons et d’électrons dans la caverne d’ATLAS et sont recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons thermiques et des neutrons rapides respectivement. Les collisions à haute énergie sont dominées par des interactions partoniques avec petit moment transverse pT , associés à des événements de “minimum bias”. Dans notre cas la collision proton-proton se produit avec une énergie de 7 TeV dans le centre de masse avec une luminosité de 10³⁴cm⁻²s⁻¹ telle que fixée dans les simulations. On utilise la simulation des événements de "minimum bias" générés par PYTHIA en utilisant le cadre Athena qui fait une simulation GEANT4 complète du détecteur ATLAS pour mesurer le nombre de photons, d’électrons, des muons qui peuvent atteindre les détecteurs ATLASMPX dont les positions de chaque détecteur sont incluses dans les algorithmes d’Athena. Nous mesurons les flux de neutrons thermiques et rapides, générés par GCALOR, dans les régions de fluorure de lithium et de polyéthylène respectivement. Les résultats des événements de “minimum bias” et les flux de neutrons thermiques et rapides obtenus des simulations sont comparés aux mesures réelles des détecteurs ATLAS-MPX.
Resumo:
Les mécanismes qui entretiennent le cycle magnétique solaire sont encore aujourd’hui relativement mal compris. Entre autres, certains travaux suggèrent la présence d’insta- bilités magnétohydrodynamiques qui pourraient avoir une influence significative sur la période du cycle par leur capacité à accélérer la destruction des structures magnétiques à grandes échelles. Nous analysons la présence des instabilités au sein des simulations effectuées à l’aide du modèle EULAG-MHD en utilisant premièrement une méthodologie basée sur un proxy spécifique associé à l’instabilité et en le comparant à un proxy similaire, mais pour le cycle magnétique solaire observé dans notre modèle. Cette méthodologie fait ressortir une évolution temporellement cyclique du proxy de l’instabilité avec des amplitudes similaires au proxy du cycle magnétique, mais présentant un léger déphasage. Nous poursuivons cette analyse en appliquant une méthode se basant sur le découpage de “zones instables” via le critère de Tayler dans la zone stable de notre modèle. L’application expose une migration équatoriale d’une zone instable qui débute à très hautes latitudes aux pôles, passe par le champ toroïdal classique, accélère et atteint l’équateur. Cette zone instable semble accélérer la destruction du champ magnétique présent, laissant place au nouveau champ pour la prochaine demie-période du cycle. La combinaison de ces deux analyses permet d’énoncer un scénario plausible qui inclut les effets d’une telle instabilité sur le cycle magnétique ainsi que sur la stabilité globale de notre simulation. Dans ce scénario, il est important de noter que les inversions de polarités semblent indépendantes de cette instabilité, qui ne ferait qu’accélérer le processus de destruction du champ déjà en place.