916 resultados para Biomedical Image Processing


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The eye is a complex organ, which provides one of our most important senses, sight. The retina is the neuronal component of the eye and represents the connection with the central nervous system for the transmission of the information that leads to image processing. Retinitis pigmentosa (RP) is one of the most common forms of inherited retinal degeneration, in which the primary death of rods, resulting in night blindness, is always followed by the loss of cones, which leads to legal blindness. Clinical and genetic heterogeneity in retinitis pigmentosa is not only due to different mutations in different genes, but also to different effects of the same mutation in different individuals, sometimes even within the same family. My thesis work has been mainly focused on an autosomal dominant form of RP linked to mutations in the PRPF31 gene, which often shows reduced penetrance. Our study has led to the identification of the major regulator of the penetrance of PRPF31 mutations, the CNOT3 protein, and to the characterization of its mechanism of action. Following the same rationale of investigating molecular mechanisms that are responsible for clinical and genetic heterogeneity of retinitis pigmentosa, we studied a recessive form of the disease associated with mutations in the recently-identified gene FAMI61 A, where mutations in the same gene give rise to variable clinical manifestations. Our data have increased the knowledge of the relationship between genotype and phenotype in this form of the disease. Whole genome sequencing technique was also tested as a strategy for disease gene identification in unrelated patients with recessive retinitis pigmentosa and proved to be effective in identifying disease-causing variants that might have otherwise failed to be detected with other screening methods. Finally, for the first time we reported a choroidal tumor among the clinical manifestations of PTEN hamartoma tumor syndrome, a genetic disorder caused by germline mutations of the tumor suppressor gene PTEN. Our study has highlighted the heterogeneity of this choroidal tumor, showing that genetic and/or epigenetic alterations in different genes may contribute to the tumor development and growth. - L'oeil est un organe complexe, à l'origine d'un de nos sens les plus importants, la vue. La rétine est la composante neuronale de l'oeil qui constitue la connexion avec le système nerveux central pour la transmission de l'information et qui conduit à la formation des images. La rétinite pigmentaire (RP) est une des formes les plus courantes de dégénérescence rétinienne héréditaire, dans laquelle la mort primaire de bâtonnets, entraînant la cécité nocturne, est toujours suivie par la perte de cônes qui conduit à la cécité complète. L'hétérogénéité clinique et génétique dans la rétinite pigmentaire n'est pas seulement due aux différentes mutations dans des gènes différents, mais aussi à des effets différents de la même mutation chez des individus différents, parfois même dans la même famille. Mon travail de thèse s'est principalement axé sur une forme autosomique dominante de RP liée à des mutations dans le gène PRPF31, associées souvent à une pénétrance réduite, me conduisant à l'identification et à la caractérisation du mécanisme d'action du régulateur principal de la pénétrance des mutations: la protéine CNOT3. Dans la même logique d'étude des mécanismes moléculaires responsables de l'hétérogénéité clinique et génétique de la RP, nous avons étudié une forme récessive de la maladie associée à des mutations dans le gène récemment identifié FAMI61 A, dont les mutations dans le même gène donnent lieu à des manifestations cliniques différentes. Nos données ont ainsi accru la connaissance de la relation entre le génotype et le phénotype dans cette forme de maladie. La technique de séquençage du génome entier a été ensuite testée en tant que stratégie pour l'identification du gène de la maladie chez les patients atteints de RP récessive. Cette approche a montré son efficacité dans l'identification de variantes pathologiques qui n'auraient pu être détectées avec d'autres méthodes de dépistage. Enfin, pour la première fois, nous avons identifié une tumeur choroïdienne parmi les manifestations cliniques du PTEN hamartoma tumor syndrome, une maladie génétique causée par des mutations germinales du gène suppresseur de tumeur PTEN. Notre étude a mis en évidence l'hétérogénéité de cette tumeur choroïdienne, montrant que les altérations génétiques et/ou épigénétiques dans les différents gènes peuvent contribuer au développement et à la croissance tumorale.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two-dimensional (2D)-breath-hold coronary magnetic resonance angiography (MRA) has been shown to be a fast and reliable method to depict the proximal coronary arteries. Recent developments, however, allow for free-breathing navigator gated and navigator corrected three-dimensional (3D) coronary MRA. These 3D approaches have potential for improved signal-to-noise ratio (SNR) and allow for the acquisition of adjacent thin slices without the misregistration problems known from 2D approaches. Still, a major impediment of a 3D acquisition is the increased scan time. The purpose of this study was the implementation of a free-breathing navigator gated and corrected ultra-fast 3D coronary MRA technique, which allows for scan times of less than 5 minutes. Twelve healthy adult subjects were examined in the supine position using a navigator gated and corrected ECG triggered ultra-fast 3D interleaved gradient echo planar imaging sequence (TFE-EPI). A 3D slab, consisting of 20 slices with a reconstructed slice thickness of 1.5 mm, was acquired with free-breathing. The diastolic TFE-EPI acquisition block was preceded by a T2prep pre-pulse, a diaphragmatic navigator pulse, and a fat suppression pre-pulse. With a TR of 19 ms and an effective TE of 5.4 ms, the duration of the data acquisition window duration was 38 ms. The in-plane spatial resolution was 1.0-1.3 mm*1.5-1.9 mm. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and right coronary artery (RCA) could be visualized with an average scan time for the entire 3D-volume data set of 2:57 +/- 0:51 minutes. Average contiguous vessel length visualized was 53 +/- 11 mm (range: 42 to 75 mm) for the LAD and 84 +/- 14 mm (range: 62 to 112 mm) for the RCA. Contrast-to-noise between coronary blood and myocardium was 5.0 +/- 2.3 for the LM/LAD and 8.0 +/- 2.9 for the RCA, resulting in an excellent suppression of myocardium. We present a new approach for free-breathing 3D coronary MRA, which allows for scan times superior to corresponding 2D coronary MRA approaches, and which takes advantage of the enhanced SNR of 3D acquisitions and the post-processing benefits of thin adjacent slices. The robust image quality and the short average scanning time suggest that this approach may be useful for screening the major coronary arteries or identification of anomalous coronary arteries. J. Magn. Reson. Imaging 1999;10:821-825.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A practical activity designed to introduce wavefront coding techniques as a method to extend the depth of field in optical systems is presented. The activity is suitable for advanced undergraduate students since it combines different topics in optical engineering such as optical system design, aberration theory, Fourier optics, and digital image processing. This paper provides the theoretical background and technical information for performing the experiment. The proposed activity requires students able to develop a wide range of skills since they are expected to deal with optical components, including spatial light modulators, and develop scripts to perform some calculations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Real-world images are complex objects, difficult to describe but at the same time possessing a high degree of redundancy. A very recent study [1] on the statistical properties of natural images reveals that natural images can be viewed through different partitions which are essentially fractal in nature. One particular fractal component, related to the most singular (sharpest) transitions in the image, seems to be highly informative about the whole scene. In this paper we will show how to decompose the image into their fractal components.We will see that the most singular component is related to (but not coincident with) the edges of the objects present in the scenes. We will propose a new, simple method to reconstruct the image with information contained in that most informative component.We will see that the quality of the reconstruction is strongly dependent on the capability to extract the relevant edges in the determination of the most singular set.We will discuss the results from the perspective of coding, proposing this method as a starting point for future developments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Visualization of the vascular systems of organs or of small animals is important for an assessment of basic physiological conditions, especially in studies that involve genetically manipulated mice. For a detailed morphological analysis of the vascular tree, it is necessary to demonstrate the system in its entirety. In this study, we present a new lipophilic contrast agent, Angiofil, for performing postmortem microangiography by using microcomputed tomography. The new contrast agent was tested in 10 wild-type mice. Imaging of the vascular system revealed vessels down to the caliber of capillaries, and the digital three-dimensional data obtained from the scans allowed for virtual cutting, amplification, and scaling without destroying the sample. By use of computer software, parameters such as vessel length and caliber could be quantified and remapped by color coding onto the surface of the vascular system. The liquid Angiofil is easy to handle and highly radio-opaque. Because of its lipophilic abilities, it is retained intravascularly, hence it facilitates virtual vessel segmentation, and yields an enduring signal which is advantageous during repetitive investigations, or if samples need to be transported from the site of preparation to the place of actual analysis, respectively. These characteristics make Angiofil a promising novel contrast agent; when combined with microcomputed tomography, it has the potential to turn into a powerful method for rapid vascular phenotyping.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we present a new method to track bonemovements in stereoscopic X-ray image series of the kneejoint. The method is based on two different X-ray imagesets: a rotational series of acquisitions of the stillsubject knee that will allow the tomographicreconstruction of the three-dimensional volume (model),and a stereoscopic image series of orthogonal projectionsas the subject performs movements. Tracking the movementsof bones throughout the stereoscopic image series meansto determine, for each frame, the best pose of everymoving element (bone) previously identified in the 3Dreconstructed model. The quality of a pose is reflectedin the similarity between its simulated projections andthe actual radiographs. We use direct Fourierreconstruction to approximate the three-dimensionalvolume of the knee joint. Then, to avoid the expensivecomputation of digitally rendered radiographs (DRR) forpose recovery, we reformulate the tracking problem in theFourier domain. Under the hypothesis of parallel X-raybeams, we use the central-slice-projection theorem toreplace the heavy 2D-to-3D registration of projections inthe signal domain by efficient slice-to-volumeregistration in the Fourier domain. Focusing onrotational movements, the translation-relevant phaseinformation can be discarded and we only consider scalarFourier amplitudes. The core of our motion trackingalgorithm can be implemented as a classical frame-wiseslice-to-volume registration task. Preliminary results onboth synthetic and real images confirm the validity ofour approach.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To objectively characterize different heart tissues from functional and viability images provided by composite-strain-encoding (C-SENC) MRI. MATERIALS AND METHODS: C-SENC is a new MRI technique for simultaneously acquiring cardiac functional and viability images. In this work, an unsupervised multi-stage fuzzy clustering method is proposed to identify different heart tissues in the C-SENC images. The method is based on sequential application of the fuzzy c-means (FCM) and iterative self-organizing data (ISODATA) clustering algorithms. The proposed method is tested on simulated heart images and on images from nine patients with and without myocardial infarction (MI). The resulting clustered images are compared with MRI delayed-enhancement (DE) viability images for determining MI. Also, Bland-Altman analysis is conducted between the two methods. RESULTS: Normal myocardium, infarcted myocardium, and blood are correctly identified using the proposed method. The clustered images correctly identified 90 +/- 4% of the pixels defined as infarct in the DE images. In addition, 89 +/- 5% of the pixels defined as infarct in the clustered images were also defined as infarct in DE images. The Bland-Altman results show no bias between the two methods in identifying MI. CONCLUSION: The proposed technique allows for objectively identifying divergent heart tissues, which would be potentially important for clinical decision-making in patients with MI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we propose an innovative methodology for automated profiling of illicit tablets bytheir surface granularity; a feature previously unexamined for this purpose. We make use of the tinyinconsistencies at the tablet surface, referred to as speckles, to generate a quantitative granularity profileof tablets. Euclidian distance is used as a measurement of (dis)similarity between granularity profiles.The frequency of observed distances is then modelled by kernel density estimation in order to generalizethe observations and to calculate likelihood ratios (LRs). The resulting LRs are used to evaluate thepotential of granularity profiles to differentiate between same-batch and different-batches tablets.Furthermore, we use the LRs as a similarity metric to refine database queries. We are able to derivereliable LRs within a scope that represent the true evidential value of the granularity feature. Thesemetrics are used to refine candidate hit-lists form a database containing physical features of illicittablets. We observe improved or identical ranking of candidate tablets in 87.5% of cases when granularityis considered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a feedback control scheme to stabilize unstable cellular patterns during the directional solidification of a binary alloy. The scheme is based on local heating of cell tips which protrude ahead of the mean position of all tips in the array. The feasibility of this scheme is demonstrated using phase-field simulations and, experimentally, using a real-time image processing algorithm, to track cell tips, coupled with a movable laser spot array device to heat the tips locally. We demonstrate, both numerically and experimentally, that spacings well below the threshold for a period-doubling instability can be stabilized. As predicted by the numerical calculations, cellular arrays become stable with uniform spacing through the feedback control which is maintained with minimal heating.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Current limitations of coronary magnetic resonance angiography (MRA) include a suboptimal signal-to-noise ratio (SNR), which limits spatial resolution and the ability to visualize distal and branch vessel coronary segments. Improved SNR is expected at higher field strengths, which may provide improved spatial resolution. However, a number of potential adverse effects on image quality have been reported at higher field strengths. The limited availability of high-field systems equipped with cardiac-specific hardware and software has previously precluded successful in vivo human high-field coronary MRA data acquisition. In the present study we investigated the feasibility of human coronary MRA at 3.0 T in vivo. The first results obtained in nine healthy adult subjects are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In three-dimensional (3D) coronary magnetic resonance angiography (MRA), the in-flow contrast between the coronary blood and the surrounding myocardium is attenuated as compared to thin-slab two-dimensional (2D) techniques. The application of a gadolinium (Gd)-based intravascular contrast agent may provide an additional source of signal and contrast by reducing T(1blood) and supporting the visualization of more distal or branching segments of the coronary arterial tree. In six healthy adults, the left coronary artery (LCA) system was imaged pre- and postcontrast with a 0.075-mmol/kg bodyweight dose of the intravascular contrast agent B-22956. For imaging, an optimized free-breathing, navigator-gated and -corrected 3D inversion recovery (IR) sequence was used. For comparison, state-of-the-art baseline 3D coronary MRA with T(2) preparation for non-exogenous contrast enhancement was acquired. The combination of IR 3D coronary MRA, sophisticated navigator technology, and B-22956 allowed for an extensive visualization of the LCA system. Postcontrast, a significant increase in both the signal-to-noise ratio (SNR; 46%, P < 0.05) and contrast-to-noise ratio (CNR; 160%, P < 0.01) was observed, while vessel sharpness of the left anterior descending (LAD) artery and the left coronary circumflex (LCX) were improved by 20% (P < 0.05) and 18% (P < 0.05), respectively.