995 resultados para Aurélio Vítor
Resumo:
Bacterial cellulose (BC) films from two distinct sources (obtained by static culture with Gluconacetobacter xylinus ATCC 53582 (BC1) and from a commercial source (BC2)) were modified by bovine lactoferrin (bLF) adsorption. The functionalized films (BC+bLF) were assessed as edible antimicrobial packaging, for use in direct contact with highly perishable foods, specifically fresh sausage as a model of meat products. BC+bLF films and sausage casings were characterized regarding their water vapour permeability (WVP), mechanical properties, and bactericidal efficiency against two food pathogens, Escherichia coli and Staphylococcus aureus. Considering their edibility, an in vitro gastrointestinal tract model was used to study the changes occurring in the BC films during passage through the gastrointestinal tract. Moreover, the cytotoxicity of the BC films against 3T3 mouse embryo fibroblasts was evaluated. BC1 and BC2 showed equivalent density, WVP and maximum tensile strength. The percentage of bactericidal efficiency of BC1 and BC2 with adsorbed bLF (BC1+bLF and BC2+bLF, respectively) in the standalone films and in inoculated fresh sausages, was similar against E. coli (mean reduction 69 % in the films per se versus 94 % in the sausages) and S. aureus (mean reduction 97 % in the films per se versus 36 % in the case sausages). Moreover, the BC1+bLF and BC2+bLF films significantly hindered the specific growth rate of both bacteria. Finally, no relevant cytotoxicity against 3T3 fibroblasts was found for the films before and after the simulated digestion. BC films with adsorbed bLF may constitute an approach in the development of bio-based edible antimicrobial packaging systems.
Resumo:
OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.
Resumo:
Dissertação de mestrado em Educação Especial (área de especialização em Dificuldades de Aprendizagem Específicas)
Resumo:
This paper presents a model predictive current control applied to a proposed single-phase five-level active rectifier (FLAR). This current control strategy uses the discrete-time nature of the active rectifier to define its state in each sampling interval. Although the switching frequency is not constant, this current control strategy allows to follow the reference with low total harmonic distortion (THDF). The implementation of the active rectifier that was used to obtain the experimental results is described in detail along the paper, presenting the circuit topology, the principle of operation, the power theory, and the current control strategy. The experimental results confirm the robustness and good performance (with low current THDF and controlled output voltage) of the proposed single-phase FLAR operating with model predictive current control.
Resumo:
OBJECTIVE: To analyze our experience with percutaneous aortic balloon valvuloplasty in newborn infants with aortic stenosis, emphasizing the extraordinary importance of myocardial perfusion.METHODS: Over a 10-year-period, 21 neonates underwent percutaneous aortic balloon valvuloplasty. Age ranged from 2 to 27 days, weight ranged from 2.2 to 4.1 kg and 19 were males. All patients presented with congestive heart failure that could not be treated clinically. The onset of symptoms in the first week of life occurred in 9 patients considered as having critical aortic stenosis. Severe aortic stenosis occurred in 12 patients with the onset of symptoms in the second week of life.RESULTS: Mortality reached 100% in the patients with critical aortic stenosis. The procedure was considered effective in the 12 patients with severe aortic stenosis. Vascular complications included the loss of pulse in 12 patients and rupture of the femoral artery in 2 patients. Cardiac complications included acute aortic regurgitation in 2 patients and myocardial perforation in one. In an 8.2±1.3-year follow-up, 5 of the 12 patients died (2 patients due to septicemia and 3 patients due to congestive heart failure). Five of the other 7 patients underwent a new procedure and 2 required surgery.CONCLUSION: Percutaneous aortic valvuloplasty in neonates is not an effective procedure in the 1st week of life, because at this age the common presentation is cardiogenic shock. It is possible that, in those patients with critical aortic stenosis, dilation of the aortic valve during fetal life may change the prognosis of its clinical outcome.
Operation modes for the electric vehicle in smart grids and smart homes : present and proposed modes
Resumo:
This paper presents the main operation modes for an electric vehicle (EV) battery charger framed in smart grids and smart homes, i.e., are discussed the present-day and are proposed new operation modes that can represent an asset towards EV adoption. Besides the well-known grid to vehicle (G2V) and vehicle to grid (V2G), this paper proposes two new operation modes: Home-to-vehicle (H2V), where the EV battery charger current is controlled according to the current consumption of the electrical appliances of the home (this operation mode is combined with the G2V and V2G); Vehicle-for-grid (V4G), where the EV battery charger is used for compensating current harmonics or reactive power, simultaneously with the G2V and V2G operation modes. The vehicle-to-home (V2H) operation mode, where the EV can operate as a power source in isolated systems or as an off-line uninterruptible power supply to feed priority appliances of the home during power outages of the electrical grid is presented in this paper framed with the other operation modes. These five operation modes were validated through experimental results using a developed 3.6 kW bidirectional EV battery charger prototype, which was specially designed for these operation modes. The paper describes the developed EV battery charger prototype, detailing the power theory and the voltage and current control strategies used in the control system. The paper presents experimental results for the various operation modes, both in steady-state and during transients.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
OBJETIVO: Determinar as alterações morfofuncionais do ventrículo direito na atresia pulmonar com septo íntegro (APSI) para uma avaliação de candidatos aos diversos procedimentos terapêuticos atualmente disponíveis. MÉTODOS: Submetidos ao estudo cineangiocardiográfico utilizando-se projeções axiais, 31 pacientes com idades variando de 1 a 50 dias (x=9,6), sendo que 28 foram estudados no 1º mês de vida. Na análise estatística foram empregados o X² e calculado o intervalo de confiança de 95% (IC95), o teste de Kruskal-Wallis para a média e desvio padrão e a regressão múltipla. Considerado significativo quando alfa < 0,05. RESULTADOS: Os pacientes foram divididos em 3 grupos de acordo com a morfologia angiográfica do ventrículo direito (VD): grupo A - VD tripartide (n=16); grupo B - VD bipartide (n=9) e grupo C - VD unipartide (n=6). O diâmetro da válvula tricúspide foi de 10,28 ± 2,67 mm (A); 7,82 ± 3,41 (B) e 5,27 ± 0,57 (C) (p=0,0005). A atresia pulmonar foi da válvula em todos do grupo A e infundibular em todos do grupo C (p<0,0001). As conexões coronário-cavitárias foram infreqüentes (2/16) no grupo A e em todos do grupo C (p=0,0006), com opacificação retrógrada da aorta (fluxo do VD para a aorta) em 2 pacientes do grupo A e em todos os do grupo C (p=0,0003). Em 3 pacientes (2 do grupo C e 1 do grupo A) observou-se circulação coronariana VD dependente. A regurgitação tricúspide moderada/grave isolada teve tendência de ser mais freqüente no grupo A (p=0,0525). O ângulo que o ductus arteriosus faz com a aorta descendente foi: 104,06 ± 8,98 no grupo A; 79,17 ± 33,08 no grupo B e 39,0 ± 6,52 no grupo C (p=0,0016). A correlação entre o diâmetro da válvula tricúspide e o ângulo entre o ductus arteriosus com a aorta descendente foi 0,6568 (p=0,0002). CONCLUSÃO: Em função da heterogeneidade da morfologia do VD nos pacientes com atresia pulmonar com septo íntegro, torna-se necessário o conhecimento de todas essas informações na seleção de candidatos aos diversos procedimentos terapêuticos.
Resumo:
OBJETIVO: Determinar os fatores preditores ecocardiográficos de morte em crianças com cardiomiopatia dilatada idiopática. MÉTODOS: Estudo retrospectivo de 148 crianças com cardiomiopatia dilatada idiopática diagnosticadas entre setembro/1979 a março/2003. Critérios para inclusão: insuficiência cardíaca e redução da contratilidade no ecocardiograma, na ausência de cardiopatia congênita ou secundária. Foram analisados 470 exames, durante 244,8 meses de evolução. Parâmetros analisados: dimensão do átrio esquerdo (DAE), relação átrio esquerdo/aorta (DAE/Ao), dimensão sistólica (DSVE) e diastólica (DDVE) do VE, massa do VE (massa), dimensão do ventrículo direito (DVD), fração de ejeção do VE (FE), percentagem de encurtamento do VE (%EC), gravidade da insuficiência das valvas atrioventriculares e da valva pulmonar e medida da pressão sistólica (PsVD) e diastólica (PdVD) do VD. Foi considerado significativo erro alfa <0,05. RESULTADOS: Idade média de 2,37 anos, ocorridos 35 óbitos (23,7% - IC95=17,1% a 31,2%). ANOVA demonstrou: DAE (p<0,0001), DAE/Ao (p<0,0001), DSVE (p=0,0061), DDVE (p=0,0086), massa (p<0,0001), FE (p=0,0074), %EC (p=0,0072) e DVD (p<0,0001). O agravamento da insuficiência mitral (IM) (p=0,0113) e tricúspide (IT) (p=0,0044) foram marcadores de óbito e a presença de IM, IT e insuficiência pulmonar moderada/grave foram deletérias à sobrevida. A análise de Cox demonstrou como preditores independentes da morte: DAE/Ao (p=0,0487), FE (<0,0001) e presença de IM moderada/grave (p=0,0419). CONCLUSÃO: Os pacientes com aumento progressivo da DAE/Ao, redução da FE e agravamento progressivo da IM, a despeito do tratamento clínico, devem ser considerados precocemente em programa de transplante cardíaco.
Resumo:
OBJETIVO: Enfatizar a possibilidade diagnóstica da origem anômala de uma artéria pulmonar da aorta ascendente, em lactentes com quadro de insuficiência cardíaca clinicamente intratável e sem defeito estrutural intracardíaco. MÉTODOS: Estudo retrospectivo em quatro lactentes com insuficiência cardíaca intratável, submetidos a estudo ecocardiográfico bidimensional com cortes subcostal, supraesternal e paraesternal, e a estudo hemodinâmico e angiocardiográfico na projeção ântero-posterior. RESULTADOS: Três dos quatro lactentes tinham a artéria pulmonar direita originando-se da aorta ascendente, como diagnóstico principal. No quarto paciente a artéria pulmonar esquerda originava-se da aorta ascendente associada à ampla comunicação interventricular. Os lactentes tinham pressão em ambas artérias pulmonares em nível sistêmico. Todos foram submetidos a tratamento cirúrgico que consistiu na translocação da artéria pulmonar anômala da aorta. Não houve óbitos cardíacos imediatos ou tardios. CONCLUSÃO: Uma vez estabelecido o diagnóstico de origem anômala de artéria pulmonar da aorta ascendente, na forma isolada, a correção cirúrgica deverá ser prontamente realizada, não só pelo desenvolvimento de doença vascular pulmonar, como pelos excelentes resultados cirúrgicos atualmente obtidos.
Resumo:
Mestrado em Economia Internacional e Estudos Europeus
Resumo:
OBJETIVO: Identificar os tipos de suprimento sangüíneo vascular pulmonar na tetralogia de Fallot com atresia pulmonar por meio de estudo hemodinâmico. MÉTODOS: Foram submetidos a estudo cineangiocardiográfico 56 pacientes portadores de tetralogia de Fallot com atresia pulmonar com idade de 20 dias a 4 anos e efetuadas injeções de contraste nas seguintes estruturas vasculares: 1) veia pulmonar encunhada, 2) colaterais aortopulmonares, 3) aorta torácica e 4) ductus arteriosus e/ou shunt sistêmico pulmonar. RESULTADOS: Dos 56 pacientes, 15 tinham o suprimento sangüíneo pulmonar através de colaterais aortopulmonares, em 36 o suprimento sangüíneo pulmonar era feito isoladamente pelo ductus arteriosus e em 5 pelo ductus arteriosus e colaterais aortopulmonares. Conforme a presença ou ausência de estruturas vasculares que compõem a circulação pulmonar na tetralogia de Fallot com atresia pulmonar e do tipo de perfusão vascular pulmonar, os doentes foram classificados em 6 tipos. CONCLUSÃO: Em função da grande complexidade e extrema variabilidade do suprimento sangüíneo pulmonar na tetralogia de Fallot com atresia pulmonar torna-se possível, com este tipo de abordagem, a obtenção de informações, suficientemente necessárias, para o correto manuseio clínico-cirúrgico.
Resumo:
Dissertação de Mestrado em Comunicação Social
Resumo:
OBJETIVO: Análise do volume diastólico final ventricular esquerdo crítico, definido como o menor volume aceitável para a manutenção do débito cardíaco, na seleção de pacientes com estenose aórtica pós-valvotomia, candidatos à correção univentricular. MÉTODOS: Estudo retrospectivo em 21 pacientes com estenose aórtica, durante o primeiro ano de vida, e 232 compilados da literatura. Arbitraram-se como normais os valores do volume diastólico final (VDF) de 20 a 60 ml/m2. Foi comparado o VDF dos grupos que foram ao óbito com aqueles que sobreviveram. Procurou-se, também, estabelecer uma correlação da idade e volume ventricular, na época da valvotomia, entre os grupos. Por fim, determinou-se o VDF esquerdo crítico, obtido através de uma relação teórica entre o VDF esquerdo e freqüência cardíaca para diferentes frações de ejeção e determinados índices cardíacos (IC): 2.000 e 2.500 ml/min/m2. RESULTADOS: Para valores do VDF <20ml/m2 e >60 ml/m2, houve significância estatística entre os mortos e os sobreviventes (p<0,0001). Entretanto, na faixa entre 20 e 60 ml/m2, esta significância foi menor (p=0,0309). Também ocorreu uma maior incidência de óbito naqueles, com apresentação na primeira semana de vida. Para um IC de 2.500 ml/min/m2 e uma freqüência cardíaca de 140 bpm, o VDF crítico será de 26 ml/m2 se a fração de ejeção (FE) do ventrículo esquerdo for de 0,70 e de 44,5 ml/m2, se a FE for de 0,40. CONCLUSÃO: A análise do volume ventricular esquerdo crítico pode adicionar mais um parâmetro na indicação da correção univentricular em pacientes com estenose aórtica pós-valvotomia, durante o primeiro ano de vida.