946 resultados para Abandoned Vehicles.
Resumo:
S/N 052-003-00791-6
Resumo:
Cover title.
Resumo:
Using quantitative light microscopy and a modified immunoelectron microscopic technique, we have characterized the entry pathway of the cholera toxin binding subunit (CTB) in primary embryonic fibroblasts. CTB trafficking to the Golgi complex was identical in caveolin-1 null (Cav1 -/-) mouse embryonic fibroblasts (MEFs) and wild-type (WT) MEFs. CTB entry in the Cav1 -/- MEFs was predominantly clathrin and dynamin independent but relatively cholesterol dependent. Immunoelectron microscopy was used to quantify budded and surface-connected caveoloe and to identify noncaveolar endocytic vehicles. In WT MEFs a small fraction of the total Cav1-positive structures were shown to bud from the plasma membrane (2 % per minute), and budding increased upon okadaic acid or lactosyl ceramide treatment. However, the major carriers involved in initial entry of CTB were identified as uncoated tubular or ring-shaped structures. These carriers contained GPI-anchored proteins and fluid phase markers and represented the major vehicles mediating CTB uptake in both WT and caveolae-null cells.
Resumo:
Objective To assess the level of compliance with the new law in the United Kingdom mandating penalties for rising a hand held mobile phone while driving, to compare compliance with this law with the one on the use of seat belts, and to compare compliance with these laws between drivers of four wheel drive vehicles and drivers of normal cars. Design Observational study with two phases-one within the grace period, the other starting one week after penalties were imposed on drivers using such telephones. Setting Three busy sites in London. Participants Drivers of 38 182 normal cars and 2944 four wheel drive vehicles. Main outcome measures Proportions of drivers seen to be using hand held mobile phones and not using seat belts. Results Drivers of four wheel drive vehicles were more likely than drivers of other cars to be seen using hand held mobile phones (8.2% v 2.0%) and not complying with the law on seat belts (19.5% v 15.0%). Levels of non-compliance with both laws were slightly higher in the penalty phase of observation, and breaking one law was associated with increased likelihood of breaking the other. Conclusions The level of non-compliance with the law on the use of hand held mobile phones by drivers in London is high, as is non-compliance with the law on seat belts. Drivers of four wheel drive vehicles were four times more likely than drivers of other cars to be seen using hand held mobile phones and slightly more likely not to comply with the law on seat belts.
Resumo:
A prodrug, temozolomide acid hexyl ester (TMZA-HE), was identified as a skin-deliverable congener for temozolomide (TMZ) to treat skin cancers. Poor solubility and instability of TMZA-HE rendered a serious challenge for formulation of a topical preparation. Microemulsions (ME) were chosen as a potential vehicle for TMZA-HE topical preparations. ME systems were constructed with either oleic acid (OA) or isopropyl myristate (IPM) as the oil phase and tocopheryl (vitamin E) polyethylene glycol 1000 succinate (VE-TPGS) as a surfactant. Topical formulations of OA and IPM ME systems demonstrated beneficial solubilising ability and provided a stable environment for the prodrug, TMZA-HE. Significant differences between the microstructures of OA and IPM ME systems were revealed by freeze fracture electron microscopy (FFEM) and different loading abilities and permeation potencies between the two systems were also identified. In permeation studies, IPM ME systems, with inclusion of isopropyl alcohol (IPA) as a co-surfactant, significantly increased TMZA-HE permeation through silicon membranes and rat skin resulting in less drug retention within the skin, while OA ME systems demonstrated higher solubilising ability and a higher concentration of TMZA-HE retained within the skin. Therefore IPM ME systems are promising for transdermal delivery of TMZA-HE and OA ME systems may be a suitable choice for a topical formulation of TMZA-HE. © 2007 The Authors.
Resumo:
The initial objective of this work was to evaluate and introduce fabrication techniques based on W/0/W double emulsion and 0/W single emulsion systems with solvent evaporation for the incorporation of a surrogate macromolecule (BSA) into microspheres and microcapsules fabricated using P(HB-HV}, PEA and their blends. Biodegradation, expressed as changes in the gross and ultrastructural morphology of BSA loaded microparticulates with time was monitored using SEM concomitant with BSA release. Spherical microparticulates were successfully fabricated using both the W/0/W and 0/W emulsion systems. Both microspheres and microcapsules released BSA over a period of 24 to 26 days. BSA release from P(HB-HV)20% PCL 11 microcapsules increased steadily with time, while BSA release from all other microparticulates was characterised by an initial lag phase followed by exponential release lasting 6-11 days. Microcapsules were found to biodegrade more rapidly than microspheres fabricated from the same polymer. The incubation of microparticulates in newborn calf serum; synthetic gastric juice and pancreatin solution showed that microspheres and microcapsules were susceptible to enzymatic biodegradation. The in vitro incubation of microparticulates in Hank's buffer demonstrated limited biodegradation of microspheres and microcapsules by simple chemical hydrolysis. BSA release was thought to ocurr as a result of the macromolecule diffusing through either inherent micropores or via pores and channels generated in situ by previously dissolved BSA. However, in all cases, irrespective of percentage loading or fabrication polymer, low encapsulation efficiencies were obtained with W/0/W and 0/W techniques (4.2±0.9%- 15.5±0.5%,n=3), thus restricting the use of these techniques for the generation of microparticulate sustained drug delivery devices. In order to overcome this low encapsulation efficiency, a W/0 single emulsion technique was developed and evaluated in an attempt to minimise the loss of the macromolecule into the continuous aqueous phase and increase encapsulation efficiency. Poly(lactide-co-glycolide) [PLCG] 75:25 and 50:50, PEA alone and PEA blended with PLCG 50:50 to accelerate biodegradation, were used to microencapsulate the water soluble antibiotic vancomycin, a putative replacement for gentamicin in the control of bacterial infection in orthopaedic surgery especially during total hip replacement. Spherical microspheres (17.39±6.89~m,n=74-56.5±13.8~m,n=70) were successfully fabricated with vancomycin loadings of 10, 25 and 50%, regardless of the polymer blend used. All microspheres remained structurally intact over the period of vancomycin release and exhibited high percentage yields( 40. 75±2 .86%- 97.16±4.3%,n=3)and encapsulation efficiencies (47.75±9.0%- 96.74±13.2%,n=12). PLCG 75:25 microspheres with a vancomycin loading of 50% were judged to be the most useful since they had an encapsulation efficiency of 96.74+13.2%, n=12 and sustained therapeutically significant vancomycin release (15-25μg/ml) for up to 26 days. This work has provided the means for the fabrication of a spectrum of prototype biodegradable microparticulates, whose biodegradation has been characterised in physiological media and which have the potential for the sustained delivery of therapeutically useful macromolecules including water soluble antibiotics for orthopaedic applications.
Resumo:
Wireless power transmission technology is gaining more and more attentions in city transportation applications due to its commensurate power level and efficiency with conductive power transfer means. In this paper, an inductively coupled wireless charging system for 48V light electric vehicle is proposed. The power stages of the system is evaluated and designed, including the high frequency inverter, the resonant network, full bridge rectifier, and the load matching converter. Small signal modeling and linear control technology is applied to the load matching converter for input voltage control, which effectively controls the wireless power flow. The prototype is built with a dsPIC digital signal controller; the experiments are carried out, and the results reveal nature performances of a series-series resonant inductive power charger in terms of frequency, air-gap length, power flow control, and efficiency issues.