999 resultados para 509.221


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Although it is well recognized that the diagnosis of hypertension should be based on blood pressure (BP) measurements taken on several occasions, notably to account for a transient elevation of BP on the first readings, the prevalence of hypertension in populations has often relied on measurements at a single visit. OBJECTIVE: To identify an efficient strategy for assessing reliably the prevalence of hypertension in the population with regards to the number of BP readings required. DESIGN: Population-based survey of BP and follow-up information. SETTING AND PARTICIPANTS: All residents aged 25-64 years in an area of Dar es Salaam (Tanzania). MAIN OUTCOME MEASURES: Three BP readings at four successive visits in all participants with high BP (n = 653) and in 662 participants without high BP, measured with an automated BP device.RESULTS BP decreased substantially from the first to third readings at each of the four visits. BP decreased substantially between the first two visits but only a little between the next visits. Consequently, the prevalence of high BP based on the third reading--or the average of the second and third readings--at the second visit was not largely different compared to estimates based on readings at the fourth visit. BP decreased similarly when the first three visits were separated by 3-day or 14-day intervals. CONCLUSIONS: Taking triplicate readings on two visits, possibly separated by just a few days, could be a minimal strategy for assessing adequately the mean BP and the prevalence of hypertension at the population level. A sound strategy is important for assessing reliably the burden of hypertension in populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Boletín semanal para profesionales sanitarios de la Secretaría General de Salud Pública, Inclusión y Calidad de Vida de la Consejería de Salud y Bienestar Social

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automotive painting cabins are cleaned with several solvents, being great part of them mixtures of volatile organic compounds (VOCs), where the three xylene isomers are the most important constituents. To evaluate the work-related exposition of the cleaners that use these mixtures of solvents, xylenes have been determined in the working ambient air as well as its metabolite, o-m-p-methyl hippuric acid, has been analysed in urine to establish the dermal and respiratory exposition. This evaluation has been done in order to assess the occupational exposure to VOCs and to know the working conditions of the cleaners, but also to evaluate the effectiveness of personal protective equipment (PPE), the engineering control and the work practices.The xylenes have been chosen as indicators of exposition because they are the main components in the cleaning solvents used, with a level of concentration between 50% and 85%.The Xylenes have an occupational exposure limit (8 h TWA) of 50 ppm (221 mg/m3) and a short-term exposure limit (STEL) of 100 ppm (442 mg/m3). On the other hand, the biological exposure index (BEI) for xylenes is the sum of the total methyl hippuric acids in urine at the end of the work-shift, being the value 1500 mg/g creatinine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.