941 resultados para tissue engineering bone stem cells bioreactors finite element modeling Institute of Biomedical and Neural Engineering alginate collagen perfusion compression differentiation-inducing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heart damage caused by acute myocardial infarction (AMI) is a leading cause of death and disability in Australia. Novel therapies are still required for the treatment of this condition due to the poor reparative ability of the heart. As such, cellular therapies that assist in the recovery of heart muscle are of great current interest. Culture expanded mesenchymal stem cells (MSC) represent a stem and progenitor cell population that has been shown to promote tissue recovery in pre-clinical studies of AMI. For MSC-based therapies in the clinic, an intravenous route of administration would ideally be used due to the low cost, ease of delivery and relative safety. The study of MSC migration is therefore clinically relevant for a minimally invasive cell therapy to promote regeneration of damaged tissue. C57BL/6, UBI-GFP-BL/6 and CD44-/-/GFP+/+ mice were utilised to investigate mMSC migration. To assist in murine models of MSC migration, a novel method was used for the isolation of murine MSC (mMSC). These mMSC were then expanded in culture and putative mMSC were positive for Sca-1, CD90.2, and CD44 and were negative for CD45 and CD11b. Furthermore, mMSC from C57BL/6 and UBI-GFP-BL/6 mice were shown to differentiate into cells of the mesodermal lineage. Cells from CD44-/-/GFP+/+ mice were positive for Sca-1 and CD90.2, and negative for CD44, CD45 and CD11b however, these cells were unable to differentiate into adipocytes and chondrocytes and express lineage specific genes, PLIN and ACAN. Analysis of mMSC chemokine receptor (CR) expression showed that although mMSC do express chemokine receptors, (including those specific for chemokines released after AMI), these were low or undetectable by mRNA. However, protein expression could be detected, which was predominantly cytoplasmic. It was further shown that in both healthy (unperturbed) and inflamed tissues, mMSC had very little specific migration and engraftment after intravenous injection. To determine if poor mMSC migration was due to the inability of mMSC to respond to chemotactic stimuli, chemokine expression in bone marrow, skin injury and hearts (healthy and after AMI) was analysed at various time points by quantitative real-time PCR (qRT PCR). Many chemokines were up-regulated after skin biopsy and AMI, but the highest acute levels were found for CXCL12 and CCL7. Due to their high expression in infarcted hearts, the chemokines CXCL12 and CCL7 were tested for their effect on mMSC migration. Despite CR expression at both protein and mRNA levels, migration in response to CXCL12 and CCL7 was low in mMSC cultured on Nunclon plastic. A novel tissue culture plastic technology (UpCellTM) was then used that allowed gentle non-enzymatic dissociation of mMSC, thus preserving surface expression of the CRs. Despite this the in vitro data indicated that CXCL12 fails to induce significant migration ability of mMSC, while CCL7 induces significant, but low-level migration. We speculated this may be because of low levels of surface expression of chemokine receptors. In a strategy to increase cell surface expression of mMSC chemokine receptors and enhance their in vitro and in vivo migration capacity, mMSC were pre-treated with pro-inflammatory cytokines. Increased levels of both mRNA and surface protein expression were found for CRs by pre-treating mMSC with pro-inflammatory cytokines including TNF-á, IFN-ã, IL-1á and IL-6. Furthermore, the chemotactic response of mMSC to CXCL12 and CCL7 was significantly higher with these pretreated cells. Finally, the effectiveness of this type of cell manipulation was demonstrated in vivo, where mMSC pre-treated with TNF-á and IFN-ã showed significantly increased migration in skin injury and AMI models. Therefore this thesis has demonstrated, using in vitro and in vivo models, the potential for prior manipulation of MSC as a possible means for increasing the utility of intravenously delivery for MSC-based cellular therapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanoindentation is a useful technique for probing the mechanical properties of bone, and finite element (FE) modeling of the indentation allows inverse determination of elasto-plastic constitutive properties. However, all but one FE study to date have assumed frictionless contact between indenter and bone. The aim of this study was to explore the effect of friction in simulations of bone nanoindentation. Two dimensional axisymmetric FE simulations were performed using a spheroconical indenter of tip radius 0.6 m and angle 90°. The coefficient of friction between indenter and bone was varied between 0.0 (frictionless) and 0.3. Isotropic linear elasticity was used in all simulations, with bone elastic modulus E=13.56GPa and PoissonâŸs ratio f 0.3. Plasticity was incorporated using both Drucker-Prager and von Mises yield surfaces. Friction had a modest effect on the predicted force-indentation curve for both von Mises and Drucker-Prager plasticity, reducing maximum indenter displacement by 10% and 20% respectively as friction coefficient was increased from zero to 0.3 (at a maximum indenter force of 5mN). However, friction has a much greater effect on predicted pile-up after indentation, reducing predicted pile-up from 0.27 to 0.11 m with a von Mises model, and from 0.09 to 0.02 m with Drucker-Prager plasticity. We conclude that it is potentially important to include friction in nanoindentation simulations of bone if pile-up is used to compare simulation results with experiment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the filling and reconstruction of non-healing bone defects, the application of porous ceramic scaffold as bone substitutes is considered to be a reasonable choice. In bone tissue engineering, an ideal scaffold must satisfy several criterias such as open porosity, having high compressive strength (it depends where in body, and if external fixatures are used) and the practicability for cell migration. Many researchers have focused on enhancing the mechanical properties of hydroxyapatite scaffolds by combining it with other biomaterials, such as bioglass and polymers. Nevertheless, there is still a lack of suitable scaffolds based on porous biomaterials. In this study, zirconia scaffolds from two different templates (polyurethane (PU) and Acrylonitrile Butadiene Styrene (ABS) templates) were successfully fabricated with dissimilar fabrication techniques. The scaffold surfaces were further modified with mesoporous bioglass for the purpose of bone tissue engineering. In the study of PU template scaffold, high porosity (~88%) sol-gel derived yttria-stabilized zirconia (YSZ) scaffold was prepared by a polyurethane (PU) foam replica method using sol-gel derived zirconia for the first time, and double coated with Mesoporous Bioglass (MBGs) coating. For the ABS template scaffold, two types of templates (cube and cylinder) with different strut spacings were used and fabricated by a 3D Rapid Prototyper. Subsequently, zirconia scaffolds with low porosity (63±2.8% to 68±2.5%) were fabricated by embedding the zirconia powder slurry into the ABS templates and burning out the ABS to produce a uniform porous structure. The zirconia scaffolds were double coated with mesoporous bioglass by dip coating for the first time. The porosities of the scaffolds were calculated before and after coating. The microstructures were then examined using scanning electron microscopy and the mechanical properties were evaluated using compressive test. Accordingly, relationships between microstructure, processing and mechanical behaviour of the porous zirconia was discussed. Scaffold biocompatibility and bioactivity was also evaluated using a bone marrow stromal cell (BMSC) proliferation test and a simulated body fluid test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mesenchymal stem/stromal cells (MSC) are rapidly becoming a leading candidate for use in tissue regeneration, with first generation of therapies being approved for use in orthopaedic repair applications. Capturing the full potential of MSC will likely require the development of novel in vitro culture techniques and devices. Herein we describe the development of a straightforward surface modification of an existing commercial product to enable the efficient study of three dimensional (3D) human bone marrow-derived MSC osteogenic differentiation. Hundreds of 3D microaggregates, of either 42 or 168 cells each, were cultured in osteogenic induction medium and their differentiation was compared with that occurring in traditional two dimensional (2D) monolayer cultures. Osteogenic gene expression and matrix composition was significantly enhanced in the 3D microaggregate cultures. Additionally, BMP-2 gene expression was significantly up-regulated in 3D cultures at day 3 and 7 by approximately 25- and 30-fold, respectively. The difference in BMP-2 gene expression between 2D and 3D cultures was negligible in the more mature day 14 osteogenic cultures. These data support the notion that BMP-2 autocrine signalling is up-regulated in 3D MSC cultures, enhancing osteogenic differentiation. This study provides both mechanistic insight into MSC differentiation, as well as a platform for the efficient generation of microtissue units for further investigation or use in tissue engineering applications.