839 resultados para stent coronariano
Resumo:
OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.
Resumo:
INTRODUCTION: The arteries of bifurcation aneurysms are sometimes so angulated or tortuous that an exchange maneuver is necessary to catheterize them with a balloon or stent delivery catheter. Because of the risk of distal wire perforation associated with exchange maneuvers, we sought to find an alternative technique. METHODS: Our experience shows that a microcatheter tends to preferentially follow a previously placed microcatheter, even if the initial catheterization might be challenging. Accessing an artery with two microcatheters simultaneously may thus be an alternative to an exchange maneuver. Because of this tendency for catheters to behave like sheep following one another, we named this method the sheeping technique (ST). The ST consists of (a) first placing a 1.7 French microcatheter into the division branch requiring balloon or stent protection to straighten the course of the arteries in order to facilitate and (b) positioning in the same artery of a larger and stiffer balloon or stent microcatheter. Once the second balloon or stent microcatheter is in place, the first microcatheter can be pulled back and used to coil the aneurysm. RESULTS: Between January 2009 and December 2012, The ST was successfully used in 208/246 procedures (85 %). Conversion to an exchange maneuver was necessary in 38/246 (15 %). There were no arterial perforations or ischemic events related to the handling of both microcatheters. CONCLUSION: The sheeping technique may improve safety by replacing the need for an exchange maneuver during difficult balloon- or stent-assisted coiling.
Resumo:
Airway stenting is a common endoscopic procedure that is used to treat a variety of central airway lesions. Obstructions or fistulas involving the carina or nearby tracheobronchial structures require the use of specially designed stents, commonly referred to as Y-stents. Conventional methods of endobronchial Y-stent delivery are all characterized by a blind and apneic period during the procedure that carries the risk of stent misplacement or ventilation/oxygenation problems or both. Using combined suspension laryngoscopy, flexible bronchoscopy, and jet ventilation, we describe a technique that makes challenging bronchoscopic interventions--such as self-expandable Y-shaped airway stent delivery--easy, precise, and safe.
Resumo:
Objectifs: To describe the technique and results of radiofrequency ablation (RFA) of small renal tumors.Matériels et méthodes: 28 patients with median age 79 years were treated with RFA for small renal exophytic tumor (median size 20 mm). Most patients were poor operative candidatesbecause of associated morbidity. Four patients were treated for biopsy proven papillary tumor, 7 for clear cell carcinoma, 2 for oncocytoma and one for renalhepatocellular metastasis. No biopsy sample was obtained for the others because of a typical radiological aspect of RCC.Résultats: All patients but one were treated successfully in one session under combined ultrasound and CT guidance using either Radionics 2000 cool-tip or Bostonscientific expandable needles, one was treated in two sessions. One Splenic, 3 colic and 1 pancreatic displacement with CO2 injection and one injection of G5%solution in the costo-phrenic recessus were done in order to protect adjacent organs. Two complications were observed, one splenic iatrogenic lesion treated byembolization and one renal pelvis stenosis treated with JJ stent. After a mean follow-up of 20 months, no patient developped local recurrence on MRI follow-up.Conclusion: RFA is a simple and efficient technique pending on strict selected criteria (small size < 3 cm and exophytic lesion). Long local control is obtained with minimalmorbidity.
Resumo:
Background Patients with cirrhosis in ChildPugh class C or those in class B who have persistent bleeding at endoscopy are at high risk for treatment failure and a poor prognosis, even if they have undergone rescue treatment with a transjugular intrahepatic porto - systemic shunt (TIPS). This study evaluated the earlier use of TIPS in such patients. Methods We randomly assigned, within 24 hours after admission, a total of 63 patients with cirrhosis and acute variceal bleeding who had been treated with vasoactive drugs plus endoscopic therapy to treatment with a polytetrafluoroethylene-covered stent within 72 hours after randomization (early-TIPS group, 32 patients) or continuation of vasoactive-drug therapy, followed after 3 to 5 days by treatment with propranolol or nadolol and long-term endoscopic band ligation (EBL), with insertion of a TIPS if needed as rescue therapy (pharmacotherapyEBL group, 31 patients). Results During a median follow-up of 16 months, rebleeding or failure to control bleeding occurred in 14 patients in the pharmacotherapyEBL group as compared with 1 patient in the early-TIPS group (P=0.001). The 1-year actuarial probability of remaining free of this composite end point was 50% in the pharmacotherapyEBL group versus 97% in the early-TIPS group (P<0.001). Sixteen patients died (12 in the pharmacotherapyEBL group and 4 in the early-TIPS group, P=0.01). The 1-year actuarial survival was 61% in the pharmacotherapyEBL group versus 86% in the early-TIPS group (P<0.001). Seven patients in the pharmacotherapyEBL group received TIPS as rescue therapy, but four died. The number of days in the intensive care unit and the percentage of time in the hospital during follow-up were significantly higher in the pharmacotherapyEBL group than in the early-TIPS group. No significant diferences were observed between the two treatment groups with respect to serious adverse events. Conclusions In these patients with cirrhosis who were hospitalized for acute variceal bleeding and at high risk for treatment failure, the early use of TIPS was associated with signif icant reductions in treatment failure and in mortality. (Current Controlled Trials number, ISRCTN58150114.)
Resumo:
Pericardial and cardiac fistulae secondary to esophageal or gastric tumors are considered exceptional. They have never been the object of a literature review. We reviewed the medical literature between 1881 and 2001, searching for all published cases of pericardial or cardiac fistulae developed from esophageal and gastric tumors or favored by the applied therapy to these tumors. The cases of metastasization, tumor spread, and neoplasic pericardial effusion without fistula were excluded. Fifty patients were identified, with one original case. More than half the cases (56%) occurred in the last 25 years. Substernal pain is the main symptom. The majority of patients present at least one condition favoring fistula formation. The auscultation of a water-wheel murmur may suggest a pneumopericardium and therefore a pericardial fistula, as does a purulent pericarditis. Arrhythmias, signs of ischemia, and hematemesis point toward a ventricular fistula. Neurological and hemostasis disorders may be suspect of an atrial lesion. Diagnosis should be made by the association of a scanner and a transit. Prognosis is bad: 76% of the patients die in the first month. Pericardial or cardiac fistulae are part of the differential diagnosis of thoracic pain in patients with esophageal or gastric tumors and in patients who were treated for these pathologies. The diagnosis must be as quick as possible. An operation (patients with a good prognosis) or the placement of a stent (patients with a bad prognosis) is the only chance of survival
Resumo:
INTRODUCTION: This study is a retrospective analysis of ureteral complications and their management from a monocenter series of 277 consecutive renal transplantations. MATERIALS AND METHODS: From September 1979 to June 1999, 277 renal transplantations (cadaveric origin) were performed in 241 patients. The ureter from the kidney graft was inserted into the bladder according to the technique of extravesical implantation described by Lich-Gregoir and Campos-Freire. The study analyzed the time of occurrence and the type of complications observed. The different procedures to restore the transplanted urinary tract are presented. RESULTS: Complications occurred in 43/277 renal transplantations (15.5%). Anastomotic urine leakage or ureteral stricture were the most frequent. The time to appearance of these complications was either short (<1 month) or late (>1 month) in a similar number of cases. Most cases were managed surgically: 33/43 cases (76.7%). The most frequent surgical repair was ureterovesical reimplantation (n=13), followed by: ureteroureteral end-to-end anastomosis (native ureter-ureter transplant, n=5); pyeloureteral anastomosis (native ureter-renal pelvis transplant, n=5); simple revision of ureterovesical implantation (n=4); resection and end-to-end anastomosis of the transplant ureter (n=2); calico-vesicostomy (graft-bladder, n=1); implantation according to Boari (n=1); pyelovesicostomy with bipartition of bladder (n=1), and pyeloileocystoplasty with detubularized ileal graft (n=1). No deaths related to any of the urological complications were reported. However, 2 consecutive vesico-renal refluxes led to the loss of the kidney graft in the long-term. CONCLUSION: The rate of complications observed in this retrospective analysis is similar to the experience of other studies, ranging from 2 to 20%. If the classical extravesical ureteral bladder implantation is to remain an attractive technique due to its simplicity, the surgical team at the training center should be aware of all the means to prevent any ureteral complications, such as the choice of another implantation technique and/or insertion of a transient ureteral stent.
Resumo:
Heart failure and atrial fibrillation are the main problems in general cardiology. Our therapeutic reflections summarize new ideas in the treatment of theses pathologies but we will not forget importance of PCI. All these therapies have proven now the clinical benefit but also reduction in more morbidity and mortality. Cardiac resynchronisation therapy has shown promising results. The art of medicine to develop will be to better identify the patients benefiting from this therapy. Interventional cardiology is focusing on the acute coronary syndrome. Not only rapid intervention but also the stent technology allow significant modification of endothelial tissue reaction and therefore improve the general benefit for the patient.
Resumo:
The transapical transcatheter aortic valve implantation (TA-TAVI) in degenerated aortic bioprosthesis is an emerging therapy for surgically non-amenable patients. However, the presence of different types of aortic bioprostheses (stented and stentless), available in different sizes (19-27 mm), can be at the origin of important mismatches between the malfunctioning, degenerated aortic valves and the inner stent-valves implanted through transapical accesses (23 and 26 mm Edwards Sapien transcatheter stent-valves). We report an emergency TA-TAVI treatment of a severely regurgitant degenerated 23 mm Mitroflow aortic bioprosthesis (Sorin Group, Milano, Italy) implanted seven years earlier in an 80-year-old lady, and we reviewed the current available literature about transapical 'valve-in-valve' procedures to analyze the hemodynamic results and the ideal 'prosthesis-to-prosthesis' match.
Resumo:
OBJECTIVES: A straightforward original Chimney Graft (CG) protocol has been developed at our institution in selected cases of juxtarenal aortic aneurysm (JRAA). The aim of this study was to present our clinical experience of consecutive series with use of uncovered self-expanding stent (SES) as "Open Chimney" (OCh) in the endovascular repair (EVAR) of JRAA. METHODS: A standard endograft with suprarenal fixation struts is delivered with its proximal covered edge just below the highest RA in JRAA presenting the ostium of the two renal arteries at a different aortic level and the distance between the highest renal artery and the beginning of the aneurysm (improved landing zone) ≥10 mm. The low-lying renal artery is maintained patent by the OCh graft (standard SES) delivered from left brachial access (6 Fr). All clinical, anatomical, and operative data were prospectively collected and retrieved for the study analysis. RESULTS: From July 2010 to November 2012, OCh EVAR was offered to 22 consecutive patients considered unfit for JRAA open repair. All procedures were technically successful with aneurysm exclusion and patent OCh graft. One small perioperative type Ia endoleak spontaneously disappeared at the 3-month CT control. One patient died because of acute decompensated heart failure. One patient presented a left hemispheric stroke. The median follow-up of 18 months (range 7-35) showed aneurysm exclusion in all patients without type I and III endoleaks, SES stenosis, and/or renal impairment. CONCLUSIONS: OCh-EVAR is a straightforward technique that can be employed in selected cases of JRAA, avoiding the more complex and expensive fenestrated EVAR.
Resumo:
BACKGROUND/AIMS: The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. METHODS: Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. RESULTS: Functional analysis showed a significant decrease in global left ventricular ejection fraction (24.5 +/- 1.6%) 3 weeks after implantation. There was a trend to increased left ventricular ejection fraction after low-dose dobutamine stress (36.0 +/- 6.6%) and a significant improvement of the impaired regional anterior wall motion. PET and SPECT imaging documented chronic hibernation. Myocardial fibrosis increased significantly in the ischemic area with a gradient from epi- to endocardial. The number of arterial vessels in the ischemic area increased and coronary angiography showed abundant collateral vessels of Rentrop class 1. CONCLUSION: The presented experimental model mimics the clinical situation of chronic myocardial ischemia secondary to 1-vessel coronary disease.
Resumo:
BACKGROUND: Laparoscopic enucleation for neuroendocrine pancreatic tumors has become a feasible technique, with a reported incidence of pancreatic fistula ranging from 13 to 29 %.1 (-) 3 This report describes the first successful case of laparoscopic pancreatic enucleation with resection of the main pancreatic duct followed by end-to-end anastomosis. METHODS: A 41-year-old woman was admitted to the authors' hospital for repeated syncope. Hypoglycemia also was noted. A contrast-enhanced computed tomography examination showed a highly enhanced tumor measuring 22 mm in diameter on the ventral side of the pancreatic body adjacent to the main pancreatic duct. The patient's blood insulin level was elevated, and her diagnosis was determined to be pancreatic insulinoma. Laparoscopic pancreatic enucleation was performed. Approximately 2 cm of the main pancreatic duct was segmentally resected, and a short stent (Silicone tube: Silastic, Dow Corning Corporation, Midland, MI) was inserted. The direct anastomosis of the main pancreatic duct was performed using four separate sutures with an absorbable monofilament (6-0 PDS). RESULTS: The operation time was 166 min, and the estimated blood loss was 100 mL. The postoperative course was uneventful, and the patient was discharged from hospital on postoperative day 7. The pathologic findings showed a well-differentiated insulinoma and a negative surgical margin. A computed tomography examination performed 1 month after the operation showed a successful anastomosis with a patent main pancreatic duct. CONCLUSIONS: Laparoscopic segmental resection of the main pancreatic duct and end-to-end anastomosis can be performed safely with the insertion of a short stent. This technique also can be used for a central pancreatectomy.
Resumo:
Contexte: Le traitement de l'angine de poitrine par angioplastie coronaire transluminale percutanée (PTCA) est efficace et peu invasif, mais son impact sur la qualité de vie des patients a été relativement peu étudié avec des questionnaires spécifiques. Méthode: Durant 6 mois, tous les patients souffrant d'une angine de poitrine pour qui une PTCA élective était envisagée, et qui étaient disponibles pour un suivi à 6 mois ont été inclus dans l'étude. Le questionnaire spécifique «Seattle Angina Questionnaire» (SAQ) a été utilisé le jour avant et 6 mois après la procédure. La décision d'implanter un stent était laissée au cardiologue au moment de la procédure. Résultats: 112 patients ont été initialement inclus. Trente-neuf d'entre eux ont été traités avec une PTCA, et 62 avec une PTCA et l'implantation de stent. Il n'y avait pas de différence de sexe, d.âge, de sévérité de l'angine de poitrine, et de type de lésion coronaire entre les deux groupes. Un suivi à 6 mois a été possible pour 101 patients (90% de la cohorte initiale). La qualité de vie a été améliorée de façon spectaculaire dans 4 des 5 dimensions du SAQ (limites physiques, stabilité de l'angor, fréquence de l'angor, perception de l'angor, p <0,001). Seule, la satisfaction avec le traitement était pire lors du suivi qu'avant l'intervention (p = 0,03), en particulier la satisfaction avec les explications reçues, la conviction que tous les moyens avaient été utilisés pour le traitement, et la satisfaction globale. L'implantation d'un stent n'a eu aucun impact sur ces résultats.
Resumo:
Interventional paediatric and congenital cardiology is expanding at a rapid pace. Validated techniques (such as aortic or pulmonary valve dilatations and occlusion of persistent ductus arteriosus and atrial septal defects) are improving thanks to the use of smaller introducers and sheaths, low-profile balloons and novel devices. Moreover, catheter-based interventions have emerged as an attractive alternative to surgery in other fields: pulmonary valve replacement, balloon and stent implantation for native and recurrent coarctation, and percutaneous closure of ventricular septal defects. On the other hand, percutaneous interventions in the paediatric population may be limited by patient size or the anatomy of the defect. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. Based on a better understanding of cardiac development, fetal cardiac interventions are being attempted in order to alter the history of severe obstructive lesions. Finally, some interventional procedures still carry a low success rate-for example, pulmonary vein stenosis, even with the use of conventional stents. Biodegradable stents and devices are being developed and may find an application in this setting as well as in others. The purpose of this review is to highlight the advances in paediatric interventional cardiology since the beginning of the third millennium.
Resumo:
The purpose of this study was to assess the safety and efficacy of stenting in upper airway reconstructions for benign laryngotracheal stenosis (LTS) with a newly designed prosthesis, the LT-Mold?. The LT-Mold and its proper use during open surgery and endoscopy are described, and the experience gathered from a prospectively collected database on 65 patients treated for complex LTS or severe aspiration is reported. This series is compared to the results of other stenting methods. All patients were available for evaluation. In all but one case, the prosthesis was removed at the end of the study. The new prosthesis did not induce any stent-related trauma to the supraglottis, glottis and subglottis. Before adding a distal round-shaped silicone cap to the LT-Mold, granulation tissue was usually seen at the stent-mucosal interface at the tracheostoma level. In 14 cases, there has been a spontaneous extrusion of the prosthesis through the mouth; this problem was solved by fixing the prosthesis through the reinforced portion of the prosthesis at the cap level and by adding one fixation stitch in the supraglottis. We have to document the loss of the silicone cap in three cases. This problem was resolved by designing a new prototype with an integrated cap, glued with a slow hardening silicone glue. Fifty-four (83 %) of 65 patients were decannulated after a mean duration of stenting of 3 months (range 1-12 months). The mean follow-up after decannulation was 23 months (range 1 month to 10 years). The experience gathered with the LT-Mold shows that long-term stenting for complex LTS is safely achieved when the prosthesis is used with its distal integrated silicone cap. The softness and smoothness of the prosthesis with a round-shaped configuration of both extremities help avoid ulceration and granulation tissue formation in the reconstructed airway. Adequate fixation is mandatory to avoid extrusion.