751 resultados para shoulder girdle
Resumo:
Individuals with temporomandibular disorders (TMD) often have signs and symptoms such as intra-articular pain, muscle spasm, neck pain radiating from others who interfere with this balance. Over time can lead to postural changes and correction of the cervical spine, anterior head and shoulder asymmetry. The aim was to verify the effects of manual therapy on posture in subjects with TMD. Materials and methods: 30 volunteers (mean: 21.43± SD:1.43) of both sexes who had TMD classified according to axis I of the Research Diagnostic Criteria participated in this study. These were photographed in the anterior frontal and sagittal planes for analysis of the following angles (acromion clavicular joint, sternoclavicular joint, orbicular external, corners of the mouthand and protruding head). After, the volunteers were divided into groups ATM (manual therapy in the treatment of temporomandibular joint), Cervical (manual therapy in the treatment of cervical joint) and Control. The Kolmogokov-Smirnov test, followed by ANOVA, considering a significance level of 5% was used. Results: Groups ATM, Cervical and Control were considered homogeneous with respect to the values of the angles measured. These also showed no significant difference between the 1st, 5th and 10th sessions, so the manual therapy techniques applied to the TMJ and Cervical groups were not sufficient to change postural alignment. Conclusion: The postural alignment, the TMD patients evaluated in this study did not change after attending the sessions proposals with manual therapy techniques in the cervical and TMJ.
Resumo:
Introduction: The table tennis is characterized by requiring of the athletes intense body movement. The gestures performed by athletes require continuous postural changes, in cases of any sway in body structures may produce postural changes or initiate processes of injuries. Objective: The aim of this study was to characterize the table tennis lesions. Method: Were evaluated 31 athletes (26 males and fi ve females) with mean age 22.35±6.67 years. The subjects were interviewed with the Reported Morbidity Inquires retroactive to the 2009 season. It was used techniques of descriptive and analytical statistics. Results: The largest number of injuries was muscular (74.35%), on the shoulder (43.58%) during the movement of top spin (33.33%) in the specifi c training phase (64.1%) with symptomatic return to the activities (69.23%). Conclusion: The weekly training workload infl uences the number of lesions.
Resumo:
Background: This study analyzed the positioning of the head, trunk, and upper extremities during gait in children with visual impairment. Methods: A total of 11 children participated in this study: 6 with blindness and 5 with low vision. The kinematics of the positioning of the head, trunk, shoulders, and elbows in each participant was analyzed during the four phases of the gait cycle: foot strike, support, toe-off, and swing. Results: There were significant differences between children with blindness and low vision in the positioning of the trunk in the sagittal plane during the foot strike, support, and swing phases. Conclusions: The analysis identified postural alterations of the head, trunk, shoulder, and elbow during the children’s gait, highlighting the relevance of appropriate stimulation at an early age in orientation and mobility programs, as well as the essential presence of professionals who work with movement.
Resumo:
Pós-graduação em Ciência e Tecnologia Animal - FEIS
Resumo:
Este trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: To compare the healing and bony crest resorption at implants installed conventionally or applying an edentulous ridge expansion (ERE) technique in the maxilla.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted bilaterally. In the left side of the maxilla (Test), the flaps were elevated and the buccal plate of the alveoli and septa was removed. After 3 months of healing, partial-thickness (split) flaps were dissected and the residual alveolar bone was exposed. In the right side of the maxilla, an implant was installed conventionally (Type IV; Control) while, in the left side, the ERE technique was adopted. Hence, an expansion of the buccal bony crest was obtained, and the implant was subsequently installed (Test). After 3 months of healing, biopsies were obtained and ground sections were prepared for histological analyses.Results: A buccal vertical resorption of the bony crest of 2.2 +/- 1.2 mm and 1.6 +/- 0.7 mm was found at the test and control sites, respectively. The difference, however, did not reach statistical significance. The coronal level of osseointegration at the buccal aspect was located at 3.1 +/- 1.0 mm and 2.2 +/- 0.7 mm from the implant shoulder at the test and control sites, respectively, the difference being statistically significant. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 43% to 48% at the buccal and lingual sites. No differences reached statistical significance.Conclusions: Implants installed by applying an ERE technique may osseointegrate similarly to conventional implant installation. However, vertical and horizontal resorption of the displaced buccal bony wall occurred as well.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Selective neck dissection (SND) in clinical N-0 (cN(0)) cases of oral squamous cell carcinoma (SCC) has been performed by surgeons using a retroauricular or modified facelift approach with robotic or endoscopic assistance. However, these procedures provide cosmetic satisfaction at the cost of possible maximal invasiveness. In this prospective study, we introduced and evaluated the feasibility as well as surgical invasiveness and cosmetic outcome of endoscopically-assisted SND via a small submandibular approach.Forty-four patients with cT(1-2)N(0) oral SCC (OSCC) were randomly divided into two groups of endoscopically-assisted SND and conventional SND. Perioperative and postoperative outcomes of patients were evaluated, including the length of the incision, operating time for neck dissection, estimated blood loss during the operation, amount and duration of drainage, total hospitalization period, total number of lymph nodes retrieved, satisfaction scores based on the cosmetic results, perioperative local complications, shoulder syndrome, and follow-up information.The mean operation time in the endoscopically-assisted group (126.04 +/- A 12.67 min) was longer than that in the conventional group (75.67 +/- A 16.67 min). However, the mean length of the incision was 4.33 +/- A 0.76 cm in the endoscopically-assisted SND group, and the amount and duration of drainage, total hospital stay, postoperative shoulder pain score, and cosmetic outcomes were superior in the endoscopically-assisted SND group. Additionally, the retrieved lymph nodes and complications were comparable.Endoscopically-assisted SND via a small submandibular approach had a longer operation time than the conventional approach. However, endoscopically-assisted SND was feasible and reliable while providing minimal invasiveness and satisfactory appearance.
Resumo:
Large motor dysfunctions are observed in older adults with the age advance. Parkinson’s disease (PD) patients have motor deficits to perform daily living activities. To raise from a chair, a daily task necessary to live independently, requires both large muscle recruitment and large joint range of motion to achieve the vertical position safely. Normally, we initiate gait after raise from a chair. The aim of this study was to analyze the PD patients’ behavior when rising from a chair and initiating gait and to compare it according to the age advance. In order to do that, 23 PD patients (66.61±7.64 years old) were distributed in three age groups: Young group, between 51 and 60 years of age (n=7); intermediary group, between 61 and 70 years of age (n=7); and elderly group, over 70 years of age (n=9). There were no statistical differences among groups either for the disease evolution stage or for it compromising. The task was to stand from a chair and to initiate gait forward in three attempts. The dependent variables were: spatial and temporal (first step length and duration, and stride length, duration and velocity) and angular (flexion and extension of head, shoulder, hip, knee, and ankle). The motion of standing from a chair was divided in two phases. The data was statistically treated by means of Analyses of Variance with group as the only factor. The Scheffé’s post hoc test was used to localize differences among groups and the significance level was adjusted to p≤0.017. There were statistical differences for stride...(Complete abstract click electronic access below)
Resumo:
The aim of this study was to determine the angle of motion values for hindlimbs in clinically healthy adult Santa Ines sheep using a standard goniometer. Twenty female Santa Ines sheep weighing 32–45 kg (mean30.4, SD=3.7), and aged from three to six years old were used. A standard transparent plastic goniometer was used to measure passive maximum flexion, maximum extension, and range of motion (ROM) of the shoulder, elbow, carpal, hip, stifle, and tarsal joints, in the right and left limbs. The goniometric measurements were done with the sheep awake and in a standing position. The measurements were made in triplicate by two independent investigators. In all evaluated joints there was no significant difference between the means of both sides. No significant difference was observed between measurements performed by the two investigators. The mean (± SD) values of the measurements (degrees) were: 129 ± 4 (ROM) for tarsal joint; 46 ± 4 (flexion), 146 ± 6 (extension), and 100 ± 4 (ROM) for stifle joint; 54 ± 3 (flexion), 143 ± 7 (extension), and 89 ± 5 (ROM) for hip joint. The data obtained is useful to provide objective information of the joints. More studies are necessary using other breeds
Resumo:
This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A metal coping may undergo changes during porcelain firing, which compromises its marginal adaptation. The use of NiCrTi alloy proposes to minimize this effect through the high melting point of titanium present in its composition. This study evaluated the influence of porcelain firing cycle on the marginal adaptation of NiCrTi copings in different preparation designs. Forty standardized metal dies were fabricated with the following combinations finish line/convergence of the axial walls: 1) shoulder/6°; 2) shoulder/20°; 3) sloping shoulder/6°; 4) sloping shoulder/20°. On each die a metal ceramic restoration coping was made. The die/coping set was stabilized with orthodontic elastics, divided into four equidistant areas with three measurement points each and a cementation pressure was simulated. The measurements were taken under a stereomicroscope (32×). After the first measurement, the copings were submitted to sintering cycles simulating porcelain application. For repeated measurements, the same procedures described above were performed. Data were submitted to Student’s-t test, 1-way ANOVA and Tukey´s test (α = 0.05). Adaptation means (µm) before and after porcelain firing in different preparations were: 1) 111.92 and 127.31; 2) 124.15 and 135.48; 3) 122.19 and 138.77; 4) 166.09 and 186.72; respectively. The porcelain firing impaired adaptation, regardless of the preparation design. The preparation in a 20° sloping shoulder provided a worse adaptation when compared with preparations that had 6° and 20° shoulder, which were statistically equal. The 6° sloping shoulder was statistically equal to the other three preparation designs.
Resumo:
Pós-graduação em Fisioterapia - FCT