958 resultados para reliability measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PROPÒSIT: Estudiar l'efecte de la cirurgia LASIK en la llum dispersa i la sensibilitat al contrast. MÈTODES: Vint-i-vuit pacients van ser tractats amb LASIK. La qualitat visual es va avaluar abans de l'operació i dos mesos després. RESULTATS: La mitjana de llum dispersa i la sensibilitat al contrast abans de l'operació no va canviar en dos mesos després. Només un ull tenia un marcat augment en la llum dispersa. Nou ulls van presentar una lleugera disminució en la sensibilitat al contrast. S'han trobat dues complicacions. CONCLUSIÓ: Després de LASIK la majoria dels pacients (80%) no van tenir complicacions i van mantenir la seva qualitat visual. Uns pocs pacients (16%) van tenir una mica de qualitat visual disminuïda. Molt pocs (4%) van tenir complicacions clíniques amb disminució en la qualitat visual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Several studies in recent years have evaluated Health Related Quality of Life (HRQoL) of patients with primary hyperparathyroidism (PHPT). No disease specific questionnaires are available to assess the impact of the disease. The aim of this research is to describe the development of a new disease specific Quality of Life (QoL) questionnaire for use specifically with PHPT patients. METHODS A conceptual model was developed describing the impact of the disease and its symptoms on QoL domains. A literature review was conducted to identify the most relevant domains. A focus group with experts was used to validate the domains; 24 patients were also interviewed to complement the information from the patient's perspective. A content analysis of the interviews was performed to identify items related with the impact of the disease, leading to PHPQoL-V.1 which was presented to a sample of 67 patients. Reliability was assessed by Cronbach's coefficient alpha and item-total score correlations. Validity was assessed by a factor analysis performed to determine the number of domains. Rasch analysis was carried out in order to refine the questionnaire items. RESULTS 259 items were extracted from the interviews that were subsequently reduced to 34 items. Cronbach's coefficient alpha was 0.92. The factor analysis extracted two domains (physical and emotional). After Rasch analysis the questionnaire PHPQoL-V.2 kept 16 items (9 physical and 7 emotional). The questionnaire was developed in a Spanish population and the final version was translated to English through translation and back-translation. CONCLUSION The first disease specific HRQoL questionnaire for PHPT patients (PHPQoL-16) has been developed. Validation studies designed to assess measurement properties of this tool are currently underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In epidemiologic studies, measurement error in dietary variables often attenuates association between dietary intake and disease occurrence. To adjust for the attenuation caused by error in dietary intake, regression calibration is commonly used. To apply regression calibration, unbiased reference measurements are required. Short-term reference measurements for foods that are not consumed daily contain excess zeroes that pose challenges in the calibration model. We adapted two-part regression calibration model, initially developed for multiple replicates of reference measurements per individual to a single-replicate setting. We showed how to handle excess zero reference measurements by two-step modeling approach, how to explore heteroscedasticity in the consumed amount with variance-mean graph, how to explore nonlinearity with the generalized additive modeling (GAM) and the empirical logit approaches, and how to select covariates in the calibration model. The performance of two-part calibration model was compared with the one-part counterpart. We used vegetable intake and mortality data from European Prospective Investigation on Cancer and Nutrition (EPIC) study. In the EPIC, reference measurements were taken with 24-hour recalls. For each of the three vegetable subgroups assessed separately, correcting for error with an appropriately specified two-part calibration model resulted in about three fold increase in the strength of association with all-cause mortality, as measured by the log hazard ratio. Further found is that the standard way of including covariates in the calibration model can lead to over fitting the two-part calibration model. Moreover, the extent of adjusting for error is influenced by the number and forms of covariates in the calibration model. For episodically consumed foods, we advise researchers to pay special attention to response distribution, nonlinearity, and covariate inclusion in specifying the calibration model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Some controversy remains about the potential applicability of cognitive potentials for evaluating the cerebral activity associated with cognitive capacity. A fundamental requirement is that these neurophysiological parameters show a high level of stability over time. Previous studies have shown that the reliability of diverse parameters of the P3 component (latency and amplitude) ranges between moderate and high. However, few studies have paid attention to the retest reliability of the P3 topography in groups or individuals. Considering that changes in P3 topography have been related to different pathologies and healthy aging, the main objective of this article was to evaluate in a longitudinal study (two sessions) the reliability of P3 topography in a group and at the individual level. RESULTS The correlation between sessions for P3 topography in the grand average of groups was high (r = 0.977, p<0.001). The within-subject correlation values ranged from 0.626 to 0.981 (mean: 0.888). In the between-subjects topography comparisons, the correlation was always lower for comparisons between different subjects than for within-subjects correlations in the first session but not in the second session. CONCLUSIONS The present study shows that P3 topography is highly reliable for group analysis (comprising the same subjects) in different sessions. The results also confirmed that retest reliability for individual P3 maps is suitable for follow-up studies for a particular subject. Moreover, P3 topography appears to be a specific marker considering that the between-subjects correlations were lower than the within-subject correlations. However, P3 topography appears more similar between subjects in the second session, demonstrating that is modulated by experience. Possible clinical applications of all these results are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies have shown that obesity is associated with chronic kidney disease and end stage renal disease. These studies have used creatinine derived equations to estimate glomerular filtration rate (GFR) and have indexed GFR to body surface area (BSA). However, the use of equations using creatinine as a surrogate marker of glomerular filtration and the indexation of GFR for BSA can be questioned in the obese population. First, these equations lack precision when they are compared to gold standard GFR measurements such as inulin clearances; secondly, the indexation of GFR for 1.73 m(2) of BSA leads to a systematic underestimation of GFR compared to absolute GFR in obese patients who have BSA that usually exceed 1.73 m(2). Obesity is also associated with pathophysiological changes that can affect the pharmacokinetics of drugs. The effect of obesity on both renal function and drug pharmacokinetics raises the issue of correct drug dosage in obese individuals. This may be particularly relevant for drugs known to have a narrow therapeutic range or excreted by the kidney.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perfusion CT studies of regional cerebral blood flow (rCBF), involving sequential acquisition of cerebral CT sections during IV contrast material administration, have classically been reported to be achieved at 120 kVp. We hypothesized that using 80 kVp should result in the same image quality while significantly lowering the patient's radiation dose, and we evaluated this assumption. In five patients undergoing cerebral CT survey, one section level was imaged at 120 kVp and 80 kVp, before and after IV administration of iodinated contrast material. These four cerebral CT sections obtained in each patient were analyzed with special interest to contrast, noise, and radiation dose. Contrast enhancement at 80 kVp is significantly increased (P < .001), as well as contrast between gray matter and white matter after contrast enhancement (P < .001). Mean noise at 80 kVp is not statistically different (P = .042). Finally, performance of perfusion CT studies at 80 kVp, keeping mAs constant, lowers the radiation dose by a factor of 2.8. We, thus, conclude that 80 kVp acquisition of perfusion CT studies of rCBF will result in increased contrast enhancement and should improve rCBF analysis, with a reduced patient's irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims and objectives  This study aimed to determine the discriminant validity and the test-retest reliability of a questionnaire testing the impact of evidence-based medicine (EBM) training on doctors' knowledge and skills. Methods  Questionnaires were sent electronically to all doctors working as residents and chief residents in two French speaking hospital networks in Switzerland. Participants completed the questionnaire twice, within a 4-week interval. The discriminant validity was examined in comparing doctors' performance according to their reported EBM previous training. Proportion of agreement between both sessions of the questionnaire, Cohen's kappa and 'uniform kappa' determined its test-retest reliability. Results  The participation rate was 9.8%/7.1% to first/second session. Performance increased according to the level of doctors' previous training in EBM. The observed proportion of agreement between both sessions was over 70% for 14/19 questions, and the 'uniform kappa' was superior to 0.60 for 15/19 questions. Conclusion  The discriminant validity and test-retest reliability of the questionnaire were satisfying. The low participation rate did not prevent the study from achieving its aims.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Dynamics is a central aspect of ski jumping, particularly during take-off and stable flight. Currently, measurement systems able to measure ski jumping dynamics (e.g. 3D cameras, force plates) are complex and only available in few research centres worldwide. This study proposes a method to determine dynamics using a wearable inertial sensor-based system which can be used routinely on any ski jumping hill. The system automatically calculates characteristic dynamic parameters during take-off (position and velocity of the centre of mass perpendicular to the table, force acting on the centre of mass perpendicular to the table and somersault angular velocity) and stable flight (total aerodynamic force). Furthermore, the acceleration of the ski perpendicular to the table was quantified to characterise the skis lift at take-off. The system was tested with two groups of 11 athletes with different jump distances. The force acting on the centre of mass, acceleration of the ski perpendicular to the table, somersault angular velocity and total aerodynamic force were different between groups and correlated with the jump distances. Furthermore, all dynamic parameters were within the range of prior studies based on stationary measurement systems, except for the centre of mass mean force which was slightly lower.