844 resultados para reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The H I Parkes All Sky Survey (HIPASS) is a blind extragalactic H I 21-cm emission-line survey covering the whole southern sky from declination -90degrees to +25degrees. The HIPASS catalogue (HICAT), containing 4315 H I-selected galaxies from the region south of declination +2degrees, is presented in Meyer et al. (Paper I). This paper describes in detail the completeness and reliability of HICAT, which are calculated from the recovery rate of synthetic sources and follow-up observations, respectively. HICAT is found to be 99 per cent complete at a peak flux of 84 mJy and an integrated flux of 9.4 Jy km. s(-1). The overall reliability is 95 per cent, but rises to 99 per cent for sources with peak fluxes >58 mJy or integrated flux >8.2 Jy km s(-1). Expressions are derived for the uncertainties on the most important HICAT parameters: peak flux, integrated flux, velocity width and recessional velocity. The errors on HICAT parameters are dominated by the noise in the HIPASS data, rather than by the parametrization procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the reliability and validity of a brief physical activity assessment tool suitable for doctors to use to identify inactive patients in the primary care setting. Methods: Volunteer family doctors (n = 8) screened consenting patients (n = 75) for physical activity participation using a brief physical activity assessment tool. Inter-rater reliability was assessed within one week (n = 71). Validity was assessed against an objective physical activity monitor (computer science and applications accelerometer; n = 42). Results: The brief physical activity assessment tool produced repeatable estimates of sufficient total physical activity, correctly classifying over 76% of cases (kappa 0.53, 95% confidence interval (CI) 0.33 to 0.72). The validity coefficient was reasonable (kappa 0.40, 95% CI 0.12 to 0.69), with good percentage agreement (71%). Conclusions: The brief physical activity assessment tool is a reliable instrument, with validity similar to that of more detailed self report measures of physical activity. It is a tool that can be used efficiently in routine primary healthcare services to identify insufficiently active patients who may need physical activity advice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Consider a network of unreliable links, modelling for example a communication network. Estimating the reliability of the network-expressed as the probability that certain nodes in the network are connected-is a computationally difficult task. In this paper we study how the Cross-Entropy method can be used to obtain more efficient network reliability estimation procedures. Three techniques of estimation are considered: Crude Monte Carlo and the more sophisticated Permutation Monte Carlo and Merge Process. We show that the Cross-Entropy method yields a speed-up over all three techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 mug (.) kg(-1) (.) min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-SD) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.01 L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a 13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, many sorghum producers in the more marginal (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale and aims 'OTseeker' is an online database of randomized controlled trials (RCTs) and systematic reviews relevant to occupational therapy. RCTs are critically appraised and rated for quality using the 'PEDro' scale. We aimed to investigate the inter-rater reliability of the PEDro scale before and after revising rating guidelines. Methods In study 1, five raters scored 100 RCTs using the original PEDro scale guidelines. In study 2, two raters scored 40 different RCTs using revised guidelines. All RCTs were randomly selected from the OTseeker database. Reliability was calculated using Kappa and intraclass correlation coefficients [ICC (model 2,1)]. Results Inter-rater reliability was 'good to excellent' in the first study (Kappas >= 0.53; ICCs >= 0.71). After revising the rating guidelines, the reliability levels were equivalent or higher to those previously obtained (Kappas >= 0.53; ICCs >= 0.89), except for the item, 'groups similar at baseline', which still had moderate reliability (Kappa = 0.53). In study 2, two PEDro scale items, which had their definitions revised, 'less than 15% dropout' and 'point measures and variability', showed higher reliability. In both studies, the PEDro items with the lowest reliability were 'groups similar at baseline' (Kappas = 0.53), 'less than 15% dropout' (Kappas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test-retest reliabilities and practice affects of measures from the Rapid Screen of Concussion (RSC), in addition to the Digit Symbol Substitution Test (Digit Symbol), were examined. Twenty five male participants were tested three times; each testing session scheduled a week apart. The test-retest reliability estimates for most measures were reasonably good, ranging from .79 to .97. An exception was the delayed word recall test, which has had a reliability estimate of .66 for the first retest, and .59 for the second retest. Practice effects were evident from Times 1 to 2 on the sentence comprehension and delayed recall subtests of the RSC, Digit Symbol and a composite score. There was also a practice effect of the same magnitude found from Time 2 to Time 3 on Digit Symbol, delayed recall and the composite score. Statistics on measures for both the first and second retest intervals, with associated practice affects, are presented to enable the calculation of reliable change indices (RCI). The RCI may be used to assess any improvement in cognitive functioning after mild Traumatic Brain Injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To assess the psychometric properties of the Simplified Therapeutic Intervention Scoring System (TISS 28) scale. Materials and Methods A prospective observational design was used. Patients were recruited from a medical-surgical intensive care unit (ICU) and 4 rehabilitation wards of 2 university-affiliated hospitals in Hong Kong. Results Data necessary for the calculation of the TISS 28, the Therapeutic Intervention Scoring System (TISS 76), and severity of illness scoring system (Simplified Acute Physiology Score [SAPS II]) were recorded for each patient during the first 24 hours after his/her admission to an ICU. A significant positive correlation was found between the TISS 76 and the TISS 28 scores as well as the TISS 28 and the SAPS II scores. There was a significant difference between the TISS 28 scores among ICU patients and patients in rehabilitation wards. A significant correlation was found between the TISS 28 scores of the first and second set of TISS 28 scores. Conclusions Although the findings supported the validity and reliability of the TISS 28, there were limitations of the TISS 28 in measuring nursing workload in ICUs. Hence, continued amendment and validation of the TISS 28 on larger samples in different ICUs would be required so as to provide clinical nurses with a valid and reliable assessment of nursing workload.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The study was designed to show the validity and reliability of scoring the Physical Mobility Scale (PMS). PMS was developed by physiotherapists working in residential aged care to specifically show resident functional mobility and to provide information regarding each resident's need for supervision or assistance from one or two staff members and equipment during position changes, transfers, mobilising and personal care. Methods: Nineteen physiotherapists of varying backgrounds and experience scored the performances of nine residents of care facilities from video recordings. The performances were compared to scores on two 'gold standard' assessment tools. Four of the physiotherapists repeated the evaluations. Results: The PAIS showed excellent content validity and reliability. Conclusions: The PAIS provides graded performance of physical mobility, including level of dependency on staff and equipment. This is a major advantage over existing functional assessment tools. There is no need for specific training for physiotherapists to use the tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Product warranty is an important part of new product marketing and sales. Offering warranty implies additional costs in the form of warranty servicing cost. Product reliability has a serious impact on the warranty servicing cost. As such, effective management of product reliability must take into account the link between warranty and reliability. This paper deals with this topic and develops a framework needed for effective management of product reliability. It reviews the relevant literature and defines topics for future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.