1000 resultados para operações de determinação e indeterminação


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection (FI) spectrophotometric procedure is proposed for the determination of vitamin B6 (pyridoxine hydrochloride) in pharmaceutical preparations. Powdered samples containing from 2.5 to 4.5 mg, were previously dissolved in 0.1 mol L-1 phosphate buffer solution (pH 7.0) and a volume of 500 muL was injected directly into a carrier stream consisting of this same phosphate buffer solution, flowing at 4.4 mL min-1. The stable blue indophenol dye produced in the oxidation of pyridoxine hydrochloride by potassium hexacyanoferrate(III) and N,N-diethyl-p-phenylenediamine solution was directly measured at 684 nm. Vitamin B6 was determined in five pharmaceutical preparations in the 0.5 to 6.0 mg L-1 concentration range (calibration graph: A= -0.00499 + 0.11963 C; r= 0.9991, where A is the absorbance and C is the vitamin B6 concentration in mg L-1), with a detection limit of 0.02 mg L-1 (3 Sblank/slope). The recovery of this vitamin from three samples ranged from 97.5 to 103.3 %. The analytical frequency was 62 h-1 and r.s.d. were less than 2% for solutions containing 1.0 and 3.0 mg L-1 vitamin B6 (n= 10). The results obtained for the determination of vitamin B6 in commercial formulations were in good agreement with those obtained by a spectrophotometric procedure (r=0.9997) and also with the label values (r= 0.9998).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aspects related to the quality of human hair analysis are presented, such as sample collection, sample preparation, determination of trace elements and application examples. Also the hair morphology, the importance of this analysis and its uses and meanings are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acidity determinations method of humic acids (HA) content was developed by Schnitzer and Gupta and is a very well known procedure. Nevertheless, care is necessary to prevent measure errors due to non-controlled BaCO3 production, during the filtration and titration of HA total acidity. To overcome this problem, we developed in our laboratory a simple filtration and titration system for the determination of HA acidity under inert atmosphere. This system enables a better reproducibility and accuracy of total, carboxylic and phenolic acidity measures than those by Schnitzer and Gupta method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work proposes the application of the 4-Hidroxy-3-(2-hydroxynaphtylazo)-benzenesulphonic acid (C.I. 15670), Alizarine Violet N (AVN), as a reagent for direct aluminium determination using molecular absorption spectrophotometry in the presence of tensoatives. Al(III) cation reacts with AVN in pH 9.4, forming a red complex, stable for at least 24 hours, with absorption minimum at 607nm and, against a reagent blank, (epsiloncomplex - epsilonreagent) = -2.71x10(4) L.mol-1.cm-1. The reaction occurs in the presence of a Triton-X100 and CTAB tensoatives mixture, in the presence of EDTA. Al(III) determination is possible in the linear range of 50 up to 400ng.mL-1, with a detection limit of 41 ng.mL-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection spectrophotometric method was developed for determining aspartame in sweeteners. Sample was dissolved in water and 250 µL of the solution was injected into a carrier stream of 5.0 x 10-5 mol L-1 sodium borate solution. The sample flowed through a column (14 cm x 2.0 mm) packed with Zn3(PO4)2 immobilized in a polymeric matrix of polyester resin and Zn(II) ions were released from the solid-phase reactor by formation of the Zn(II)-aspartame complex. The mixture merged with a stream of borate buffer solution (pH 9.0) containing 0.030 % (m/v) alizarin red S and the Zn(II)-alizarin red complex formed was measured spectrophotometrically at 540 nm. The calibration graph for aspartame was linear in the concentration range from 10 to 80 µg mL-1 with a detection limit of 4 µg mL-1 of aspartame. The RSD was 0.3 % for a solution containing 40 µg mL-1 aspartame (n = 10) and seventy results were obtained per hour. The proposed method was applied for determining aspartame in commercial sweeteners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast and direct method for the determination of Cr in milk and cane sugar suspensions using graphite furnace atomic absorption spectrometry with Zeeman-effect background correction is described. No sample pre-treatment was necessary, minimizing the risk of contamination. The concentration of chromium in cane sugar was evaluated using Cr reference solutions prepared in 1% v/v HNO3 solution. The milk samples were introduced into the furnace with a mixture of amines for avoiding the autosampler blockage and foaming of milk. Chromium determination in milk was based on the standard additions method (SAM). The limit of detection and characteristic mass for cane sugar sample (30 muL) were 0,13 ng/ml and 4,3 pg, and for milk sample (10 muL) were 0,23 ng/ml and 7,8 pg, respectively. The graphite tube lifetime was 300 firings for sugar-cane sample and 100 firings for milk sample. The heating program was implemented in 68 s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A view of the general aspects involving the 2D NMR spectroscopy using inverse detection and field gradient techniques is presented through the analysis of a sesquiterpene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selenium is both essential and toxic to man and animals, depending on the concentration and the ingested form. Most fruits and vegetables are poor sources of selenium, but coconut can be a good selenium source. Samples were suspended (1 + 4 v/v) in a mixture of tertiary amines soluble in water (10% v/v CFA-C). This simple sample treatment avoided contamination and decreased the analysis time. The standard additions method was adopted for quantification. The action of the autosampler was improved by the presence of the amines mixture in the suspension. A Varian model AA-800 atomic absorption spectrometer equipped with a graphite furnace and a GTA 100 autosampler was used for selenium determination in coconut water and coconut milk. Background correction was performed by means of the Zeeman effect. Pyrolytically coated graphite tubes were employed. Using Pd as chemical modifier, the pyrolysis and the atomization temperatures were set at 1400 and 2200ºC, respectively. For six samples, the selenium concentration in coconut water varied from 6.5 to 21.0 mug L-1 and in coconut milk from 24.2 to 25.1 mug L-1. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values are in the 99.5-102.3% range. The main advantage of the proposed method is that it can be directly applied without sample decomposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration (ž³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different methods have been applied to solve special problems of metal analysis. First, the solid samples of tool steels were analyzed by X-ray fluorescence. Alternatively, an on-line electrodissolution implemented in a flow injection system and conventional dissolution procedure for determination of W, Mo, V and Cr in tool steels by ICP-AES is described. The resulting analyte solutions were compared with conventional dissolution procedure and determination by ICP-AES. The electrolytic procedure presented a good performance characterized by a sample throughput of 164 determinations per hour. Results were in agreement with those obtained by conventional acid dissolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review article on mercury compounds deals with the differences on toxicity of different forms of this metal, the Brazilian regulation for its disposal and the usual methods of determination. Besides that, the text gives special emphasis on the methods used for the treatment and disposal of residues containing mercury, as well as the new developments being made in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate a flow injection system for determination of residual CO3(2-) in soil amended with lime material. It was used a closed system were the CO2 released from soil sample acidified with 0.5 mol L-1 HCl was capted in a 0.2 mol L-1 NaOH solution. After 16h the capted CO2 was determined by conductivimetry using a flow injection system. The results obtained by the proposed method were significantly correlated with those reported in soil samples used by the International Soil Analytical Exchange Programe. The regression equation was: y = 0.987x -- 0.075 r = 0.996, P > 0.01. For acid soils amended with CaCO3 the method showed a deviation error of 2.7%, detection limit was 0.077 mmol kg-1 of CO3(2-), and a recovery of 99.7% of the total CO3(2-) added in soil sample. The method was easily adapted for routine determination of residual CO3(2-) in soil samples with an analytical frequency of 40 samples per hour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the molecular structure of molecules is of fundamental importance in chemistry. X-rays and electron diffraction methods constitute in important tools for the elucidation of the molecular structure of systems in the solid state and gas phase, respectively. The use of quantum mechanical molecular orbital ab initio methods offer an alternative for conformational analysis studies. Comparison between theoretical results and those obtained experimentally in the gas phase can make a significant contribution for an unambiguous determination of the geometrical parameters. In this article the determination of the molecular structure of the cyclooctane molecule by electron diffraction in the gas phase and ab initio calculations will be addressed, providing an example of a comparative analysis of theoretical and experimental predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure exploiting merging zones is proposed for determining vitamin B2 (riboflavin) in pharmaceutical preparations. The determination is based on the red-colored complex formation between vitamin B2 and silver(I) which was measured at 520 nm. Vitamin B2 was determined in four pharmaceutical preparations in the 1.0 to 50.0 mg L-1 concentration range, with a detection limit of 0.5 mg L-1. The recovery from three samples ranged from 98.0 to 104.0 %. The analytical frequency was 42 h-1 and r.s.d. were lower than 1% for solutions containing 10.0, 30.0 and 50.0 mg L-1 vitamin B2 (n= 10). The results obtained in commercial formulations using the FIA procedure were in good agreement with those obtained by using a conventional fluorimetric procedure (r=0.9998) and also with the label values (r= 0.9997).