742 resultados para measuring capabilities
Resumo:
We perform a complete simulation of the process e(+)e(-) --> tau(+)tau(-)nu(ν) over bar where nu can be an electron, muon or tau neutrino, in the context of a general Higgs coupling to tau-leptons. We analyse various kinematical distributions and obtain the sensitivity regions in the parameter space that can be explored at a future e(+)e(-) collider. In particular, inclusion of W boson fusion enhances the sensitivity significantly.
Resumo:
An application of photoacoustic technique is developed for determining the thermal diffusivity coefficient and the thermal conductivity of transparent materials. The backing material which supports the sample is made optically opaque, i.e., it entirely absorbs the incident light, and the converted heat diffuses through the sample heating the gas in contact with its opposite surface. The method is illustrated by fitting voltage amplitude and phase signals versus the chopping frequency in the photoacoustic cell, according to a theoretical model of heat diffusion. Thermal parameters obtained for three polymers compare very well with results from the literature. (C) 1995 American Institute of Physics.
Resumo:
Pyroelectric sensors work as a thermal transducer converting the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. Ferroelectric ceramics and ferroelectric polymers have been extensively used as thermal detectors. More recently the research in the field of pyroelectricity has been concentrated on discovering materials with higher figures of merit (FOM), which means better sensing materials. Composite materials obtained with ferroelectric ceramics embedded in polymer host have received great attention because of their formability, mechanical resistance and the possibility to change their dielectric property varying the volume fraction of ceramic particles. In this work composite films made of modified lead titanate (PZ34) and poly(ether-ether-ketone) (PEEK) were characterized and used as sensing element to measure X-ray intensity in the ortovoltage range (120 - 300 kVp). The sensor response varies from 2.70 V to 0.80 V in the energy fluency range of 6.30 to 37.20 W/m(2). Furthermore the absorbed energy was analyzed as a function of the ionizing energy. The results indicate that the PZ34/PEEK composite with 60/40 vol.% can be useful to monitor X-ray radiation therapy.
Resumo:
A new shadow-ring device for measuring diffuse solar radiation at the surface is presented. In this device the seasonal variation of shadow is followed by moving the detector horizontally. This unique characteristic facilitates its application for long and continuous periods of time. The blocking effect caused by the ring and other related geometric properties are formulated considering the diffuse solar radiation isotropic. The correction factor, shadow size, and ring-detector distance are derived as a function of radius and width of the ring, sun position, and local latitude. The largest blocking occurs during summer, when the ring-detector distance and the shadow width are the smallest, and it is compensated by a smaller blocking effect in the winter period. The performance of the new device is verified comparing daily values of diffuse solar radiation measured simultaneously with a similar device from Kipp & Zonen, Inc. The results show a very good agreement (within 2.5%) between both devices. The new device was also able to reproduce the radiometric properties of the local atmosphere based on 3-yr-long measurements of direct solar radiation using a pyrheliometer. The new device can be applied to estimate daily values of diffuse solar radiation at the surface in the range of 30degreesN-30degreesS with results comparable to other similar apparatuses.
Resumo:
A novel method is proposed for measuring the hysteresis loops of ferroelectric polymers. The samples need to have only one electrode and are poled by corona discharge in a constant current corona triode. It is shown how the sample surface potential and the charging current are related to the remanent polarization and coercive field, so that the hysteresis loops can be obtained. An illustrative example is given for samples of beta-PVDF for which the hysteresis cycles were remarkably close to those obtained with the traditional Sawyer-Tower circuit. Values of 80 MV/m and 70 mC/m2 were estimated for the coercive field and remanent polarization, respectively.
Resumo:
Abiotic factors, such as variations on salinity, exert influence on the animal distribution in the intertidal zone, including zoanthids. This study evaluated the osmotic, morphological and ethological effects of salinity variations on tropical zoanthid Zoanthus sociatus. In order to analyze the hypothesis of osmotic conformation, the zoanthid was submitted to salinity stress. To estimate the osmotic capabilities of the species studied, specimens collected in beach rocks were taken alive to the laboratory and maintained in water collected from the site. The osmoregulatory ability of Z. sociatus was determined by measuring the hemolymph osmolality under various salinity conditions and comparing it to the medium osmolality. Zoanthid Z. sociatus is able to present osmotic conformation in hemolymph salinity in a wide range of external salinity values. The bleaching frequency was high in low salinities and the mortality rate was high after two days of experiment. This experiment shows for the first time the importance of osmotic conformation in a tropical zoanthid and discusses the role of low salinity as a limiting factor for survival and distribution of these important animals in tropical coastal reefs.
Resumo:
It has been shown that people of all ages can benefit from the topical and systemic effects of water fluoridation. However, the increase in consumption of bottled water, either to substitute for or supplement consumption of water from public sources, has implications for safe fluoride supplementation. Taking that into consideration, in 1995 we analyzed the fluoride content in 31 commercial brands of mineral water in the region of Araraquara, state of Sao Paulo, Brazil. Fluoride concentration as determined by our analysis was compared to the concentration of fluoride specified on each label. Only 25% of the products studied listed the fluoride concentration on their labels. In addition, among 31 mineral water brands, 26 listed the date when the chemical analysis to determine chemical composition had been performed. Of these, 20 had not been put through the annual chemical analysis determined by Brazilian law. Based on these results, if the mineral waters tested had been the only source of drinking water, fluoride supplementation would have been necessary in 69% of the samples analyzed. In the case of children up to 6 years of age who use products containing fluoride, such as topical gels, mouthwashes or toothpastes, supplementation should be recommended only if commercially bottled water is the only source of water used, not only for drinking but for cooking as well.
Resumo:
The pulsed electric acoustic technique, PEA, has been usually applied to probe space charge profiles in polymers. Preliminary PEA results using a ferroelectric ceramic are presented. If the reverse applied electric field i of the order of the coercive field the switching polarization process occurs in a period larger than hundreds of seconds. Such a slow process allows one to use the PEA setup to follow the polarization switching dynamics and determine the electric field profile. The PEA signal obtained in the lead zirconate-titanate doped with niobium ceramic, PZTN, indicates that the polarization distribution and field are not uniform during the switching period. We were also able to observe that the acoustic wave velocity and attenuation depends on the stage of the polarization switching, which agrees with results obtained using the ultrasonic method.
Resumo:
The pulsed electric acoustic technique, PEA, have been usually applied to probe space charge profiles in polymers. In this work we show preliminary results obtained with lead zirconate-titanate and niobium, PZTN, ferroelectric ceramic samples. Experiments showed that induced charge densities on sample electrodes are mainly due to the ferroelectric polarization of the sample. We present results of the typical PEA response and the procedure to deconvolute the signal in order to obtain the charge densities and the electric field profiles. The PEA setup allows us to show a non-uniform polarization during ferroelectric switching.
Resumo:
A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric detector, which measures radiation by converting heat from absorbed incident X-rays into an electric current. This current is then converted to a voltage and digitised. The detector consists of a ferro-electric crystal; two types were tested; lithium tantalate and lithium niobate. X-ray measurement in mammography is challenging because of its relatively low photon energy range, from 11 keV to 15 keV equivalent mean energy, corresponding to a peak tube potential from 22 to 36 kV. Consequently, energy fluence rate or intensity is low compared with that of common diagnostic X-ray. The instrument is capable of measuring intensities as low as 0.25 mWm -2 with precision greater than 99%. Not only was the instrument capable of performing in the clinical environment, with high background electromagnetic interference and vibration, but its performance was not degraded after being subjected to 140 roentgen (3.6 × 10 -2 C kg -2 air) as measured by piezo-electric (d 33) or pyro-electric coefficients. © IFMBE 2005.
Resumo:
Outsourcing is related to the action which an organization deals with its suppliers through a kind of business contract where a specific activity or service has been hired to be made. The outsourcing of some activities has become a common practice in the industry, nowadays. It reduces costs, significantly, in the production process and, at the same time, adds some values to the business organization. However it is necessary to measure the performance of these activities. Data Envelopment Analysis (DEA) is a non-parametric method useful to measure comparative performance. It has a wide range of applications measuring comparative efficiency. The Analytic Hierarchy Process (AHP) is a multiple criteria decision-making method that uses hierarchic structures to represent a decision problem and then develops priorities for the alternatives based on the decision-maker's judgments. This paper presents an integrated application based on DEA and AHP to evaluate the efficiency of subcontracted companies in a Brazilian aerospace factory. © 2007 Springer-Verlag London Limited.
Resumo:
Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.
Resumo:
Includes bibliography
Resumo:
Includes bibliography