892 resultados para locking screw
Resumo:
This research had as objective to evaluate the effect of extrusion temperature and screw speed on physical and rheological properties, as well as, the sensory acceptance of cassava and passion fruit snacks produced in single-screw extruder. A central composite design with 11 treatments was used, considering as dependent variables: expansion index (EI), specific volume (SV), water solubility index (WSI), water absorption index (WAI), color (L*, a*, b*) and pasting properties (RVA). The products were flavored and analyzed for global acceptance. The results showed significant effects of temperature and screw speed on the dependent variables. The chocolate flavored snacks obtained good acceptance.
Resumo:
Short cooking time and ability to blend varieties of food ingredients have made extrusion cooking a medium for low-cost and nutritionally improved food products. The effect of moisture, extrusion temperature and amount of turmeric flour mixed with cassava flour on physical characteristic of puffed snacks was evaluated in this work. Extrusion process was carried out using a single-screw extruder in a factorial central composite design with four factors. Results showed effect of extrusion parameters on dependents variables. High expansion, low browning, low water solubility index, intermediate water absorption index and high crispness desirable characteristics to puffed snacks are obtained in conditions of 12% moisture, 5% turmeric flour, 105º C of temperature and 250 rpm of screw speed. These paper point to the potential still unexplored of the use of flours of cassava and turmeric as raw materials in the development of extruded puffed snacks.
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study aimed to evaluate the survival probability of four narrow-diameter implant systems when subjected to fatigue loading. Materials and Methods: Seventy-two narrow-diameter implants to be restored with single-unit crowns were divided into four groups (n = 18): Astra Tech (3.5-mm diameter), with a standard connection (ASC); BioHorizon (3.4-mm diameter), with a standard connection (BSC); Intra-Lock (3.4-mm diameter), with a standard multilobular connection (ISC); and Intra-Lock (3.4-diameter), with a modified square connection (IMC). The corresponding abutments were screwed onto the implants, and standardized metal crowns (maxillary central incisors) were cemented and subjected to step-stress accelerated life testing in water. Use-level probability Weibull curves and reliability for 100,000 cycles at 150 and 200 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used to access the failure modes. Results: The calculated survival probability for 100,000 cycles at 150 N was approximately 93% in group ASC, 98% in group BSC, 94% in group ISC, and 99% in group IMC. At 200 N, the survival rate was estimated to be approximately < 0.1% for ASC, 77% for BSC, 34% for ISC, and 93% for IMC. Abutment screw fracture was the main failure mode for all groups. Conclusions: Although the probability of survival was not significantly different among systems at a load of 150 N, a significant decrease was observed at 200 N for all groups except IMC.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Several reconstructive methods of the alveolar ridge have been reported to make possible future rehabilitations with implants. Many of these methods come from studies done in animals, mainly rats. With this clinical practice based on scientific evidence, any experimental procedure that can be undertaken in real life is fundamental. Thus, any research that emulates as closely as possible those techniques used in humans are important. This study describes the modification of the technique for block bone graft fixation (onlay) in rats using the lag screw-type technique, normally used in clinical procedures for grafts in humans. The conclusion was that the execution of the described procedures minimizes interference of blood flow in the area because of the maintenance of the muscle insertion in the buckle aspect of the most anterior region of the mandible, providing better stability to the graft and better contact interface of the graft and receptor bed.
Influence of abutment-to-fixture design on reliability and failure mode of all-ceramic crown systems
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study aimed to evaluate the role of the implant/abutment system on torque maintenance of titanium retention screws and the vertical misfit of screw-retained implant-supported crowns before and after mechanical cycling. Materials and Methods: Three groups were studied: morse taper implants with conical abutments (MTC group), external-hexagon implants with conical abutments (EHC group), and external-hexagon implants with UCLA abutments (EHU group). Metallic crowns casted in cobalt-chromium alloy were used (n = 10). Retention screws received insertion torque and, after 3 minutes, initial detorque was measured. Crowns were retightened and submitted to cyclic loading testing under oblique loading (30 degrees) of 130 +/- 10 N at 2 Hz of frequency, totaling 1 x 10(6) cycles. After cycling, final detorque was measured. Vertical misfit was measured using a stereomicroscope. Data were analyzed by analysis of variance, Tukey test, and Pearson correlation test (P < .05). Results: All detorque values were lower than the insertion torque both before and after mechanical cycling. No statistically significant difference was observed among groups before mechanical cycling. After mechanical cycling, a statistically significantly lower loss of detorque was verified in the MTC group in comparison to the EHC group. Significantly lower vertical misfit values were noted after mechanical cycling but there was no difference among groups. There was no significant correlation between detorque values and vertical misfit. Conclusions: All groups presented a significant decrease of torque before and after mechanical cycling. The morse taper connection promoted the highest torque maintenance. Mechanical cycling reduced the vertical misfit of all groups, although no significant correlation between vertical misfit and torque loss was found.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
We surveyed subjective symptoms of 600 patients referred to the Occlusion and Craniomandibular Dysfunction Center of the School of Dentistry, Campus of São José dos Campos São Paulo, Brazil. We have only considered those symptoms reported by the patients as major complaints. Our purpose on this project was to draw a profile of the disease considering sex, age and incidence of the symptoms that presented themselves or associated with others. Findings were that we found a significant larger number of women, 82.83%, comparing with 17.17% of men. Most of the patients belonged to the third decade, followed by the fourth and second. The most frequent symptom was pain on TMJ region, 42%, followed by TMJ noises, 26.6%, facial pain, 15.5%, earache, 14.5% and headache, 12.1%. The symptom TMJ noises showed to be statistically more significant in men, while headaches, pain in the neck region and temporary locking were more frequent in women. The most frequent association between two symptoms was: TMJ noises with TMJ pain, earache with headache and TMJ pain with earache. There was no statistical difference between sexes. The most frequent association of three symptoms was: TMJ noises together with TMJ pain and pain or difficulty in chewing