949 resultados para high-speed cutting


Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present a first overview of flows in the high latitude ionosphere observed at 15 s resolution using the U.K.-Polar EISCAT experiment. Data are described from experiments conducted on two days, 27 October 1984 and 29 August 1985, which together span the local times between about 0200 and 2130MLT and cover five different regions of ionospheric flow. With increasing local time, these are: the dawn auroral zone flow cell, the dayside region of low background flows equatorward of the flow cells, the dusk auroral zone flow cell, the boundary region between the dusk auroral zone and the polar cap, and the evening polar cap. Flows in both the equatorward and poleward portions of the auroral zone cells appear to be relatively smooth, while in the central region of high speed flow considerable variations are generally present. These have the form of irregular fluctuations on a wide range of time scales in the early morning dawn cell, and impulsive wave-like variations with periods of a few minutes in the afternoon dusk cell. In the dayside region between the flow cells, the ionosphere is often essentially stagnant for long intervals, but low amplitude ULF waves with a period of about 5 min can also occur and persist for many cycles. These conditions are punctuated at one to two hour intervals by sudden ‘flow burst’ events with impulsively generated damped wave trains. Initial burst flows are generally directed poleward and can peak at line-of-sight speeds in excess of 1 km s^{−1} after perhaps 45 s. Flows in the polar cap are reasonably smooth on time scales of a few minutes and show no evidence for the presence of ULF waves. Under most, but not all, of the above conditions, the beam-swinging algorithm used to determine background vector flows should produce meaningful results. Comparison of these flow data with simultaneous plasma and magnetic field measurements in the solar wind, made by the AMPTE IRM and UKS spacecraft, emphasizes the strong control exerted on high latitude flows by the north-south component of the IMF.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Films that feature high-speed diegetic motion, and present those high speeds through fast mobile framing and fast cutting, are frequently charged with generating a sensory overload which empties out meaning or any sense of spatial orientation. Inherent in this discourse is a privileging of optical-spatial intelligibility that suppresses consideration of the ways cinema can represent diegetic velocity, and the spectator’s sensory experience of the same. This paper will instead highlight the centrality of the evocation of a trajectory for movement for the spectator’s experience of diegetic speed, an evocation that does not depend on optical-spatial legibility for its affective force.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The current trend toward minimal-invasive dentistry has introduced innovative techniques for cavity preparation. Chemical vapor deposition (CVD) and laser-irradiation technology have been employed as an alternative to the common use of regular burs in high-speed turbines. Objectives. The purpose of this study was to assess the influence of alternative techniques for cavity preparation on the bonding effectiveness of different adhesives to dentin, and to evaluate the morphological characteristics of dentin prepared with those techniques. Methods. One etch&rinse adhesive (OptiBond FL, Kerr) and three self-etch systems (Adper Prompt L-Pop, 3M ESPE; Clearfil SE Bond, Kuraray; Clearfil S3 Bond, Kuraray) were applied on dentin prepared with a regular bur in a turbine, with a CVD bur in a turbine, with a CVD tip in ultrasound and with an ErCr:YSGG laser. The micro-tensile bond strength (mu TBS) was determined after storage in water for 24 h at 37 degrees C, and morphological evaluation was performed by means of field -emission -gun scanning electron microscopy (Feg-SEM). Results. Feg-SEM evaluation revealed different morphological features on the dentin surface after the usage of both the conventional and alternative techniques for cavity preparation, more specifically regarding smear-layer thickness and surface roughness. CVD bur-cut, CVD ultra-sonoabraded and laser-irradiated dentin resulted in lower mu TBSs than conventionally bur-cut dentin, irrespective of the adhesive employed. Significance. The techniques, such as CVD diamond-bur cutting, CVD diamond ultra-sonoabrasion and laser-irradiation, used for cavity preparation may affect the bonding effectiveness of adhesives to dentin, irrespective of their acidity or approach. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The velocity at which a golf club impacts with a golf ball is known as club head speed. Although club head speed has been used to measure performance changes in a number of golf studies, it has not been validated as a golf performance measure. As handicap is the usual measure of performance, the purpose of this study was to investigate the relationship between club head speed and handicap, and to determine whether club head speed at impact is a valid measure of golfing performance. Forty-five male golfers aged 18–80 years, all with registered golfing handicaps (2–27), participated in this study. Each golfer performed 10 golf swings captured by a high-speed camera. Golfers' club head speeds were determined using Video Expert 2, a biomechanical computer program. Golfers with a lower handicap (ie, a better skill level) had faster club head speeds than higher handicap golfers. Linear regression analysis found club head speed to be highly correlated with handicap (r= 0.950). This relationship was described by the equation: In (club head speed)= 4.065 − 0.0214 x handicap. In conclusion, this study has shown that club head speed is a valid indicator of performance in golfers and may therefore be a useful performance measure in future laboratory-based studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Physical vapour deposition (PVD) titanium aluminium nitride coated cutting tools are used extensively in global manufacturing for reducing production costs and improving productivity in a number of aggressive metal-cutting operations, namely, dry and high-speed machining. In this investigation, the performance of Ti1−xAlxN and Ti1−x−yAlxCryN coatings was assessed on Co-HSS twist drills used to machine grey cast iron. The failure criterion for drills was defined as a critical sized flank wear land at the outer corners of the drills. Using this criterion, the average tool life of uncoated twist drills was increased by factors of 2.5, 3.0 and 3.0 by Ti0.59Al0.41N, Ti0.27Al0.19Cr0.54N and Ti0.21Al0.14Cr0.65N coatings, respectively. Notwithstanding the similar increase in average tool life, the Ti1−x−yAlxCryN coatings produced more consistent results than the Ti1−xAlxN coated drills with standard deviations of 67, 3 and 19 holes, respectively. This result has significant practical implications in manufacturing, since drills are not replaced on an individual basis, but rather on a preset tool change frequency. The present paper discusses the performance of Ti1−xAlxN and Ti1−x−yAlxCryN coated drills in terms of average and practical drill life and concludes with remarks on the characterisation of PVD coatings and their significance on the performance of Co-HSS twist drills when dry machining grey cast iron.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cathodic arc evaporation (CAE) is a widely used technique for generating highly ionised plasma from which hard, wear-resistant PVD coatings can be deposited. A major drawback of this technique is the emission of micrometer-sized droplets of cathode material from the arc spot, which are commonly referred to as ‘macroparticles’. In this study, the effect of cathode poisoning was investigated as a method to reduce the number of macroparticles in PVD coatings. While the study focuses on the reduction of macroparticles in titanium nitride coatings, the outcomes and key findings can be broadly applied to the cathodic arc process, in particular, for the reduction of macroparticles in more advanced CAE coatings. The results support earlier findings that have shown that poisoning of the cathode can reduce the number of macroparticles emitted from the arc spot. The results of glow discharge optical emission spectroscopy (GD-OES) showed that the titanium content of the coatings varied little between the respective coatings despite changes in the deposition pressure from 0.1 to 1.2 Pa. The GD-OES results also showed the presence of oxide contamination at the surface of the coatings, which was significantly reduced with increasing deposition pressure. The coatings were also deposited onto high-speed steel twist drills to compare the metal-cutting performance when dry drilling a workpiece of cast iron. The results of the drill tests showed that tool life increased with a reduction in the number of macroparticles.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Judging time-to-contact with a target is an important criterion for avoiding harm in everyday walking and running tasks, and maximizing performance in high-velocity sporting tasks. The information-based regulation of step length and duration during target-directed locomotion was examined in relation to gait mode, approach velocity, target task, expertise, and sporting performance during a series of four experiments. The first three experiments examined novice performers (Each n=12, 6 males, 6 females), whilst the last experiment examined expert gymnasts (n=5). Two reference strips with alternating 50cm black and white intervals were placed on either side of the approach strip for all of the experiments. One 50Hz-panning video camera filmed the approach from an elevated position. In Experiment 4, two stationary 250Hz cameras filmed the post-flight performance of the gymnastic vaults and, in addition, two qualified judges provided a performance score for each vaulting trial. The panning video footage in each experiment was digitized to deduce the gait characteristics. In Experiment 4, the high-speed video footage was analyzed three-dimensionally to obtain the performance measures such as post-flight height. The utilization of visual stimulus in target-directed locomotion is affected by the observer's state of motion as characterized by the mode of locomotion and also often the speed of locomotion. In addition, experience plays an important role in the capacity of the observer to utilize visual stimulus to control the muscular action of locomotion when either maintaining or adjusting the step mechanics. The characteristics of the terrain and the target also affect the observer's movement. Visual regulation of step length decreases at higher approach speeds in novice performers, where as expert performers are capable of increasing visual regulation at higher approach speeds. Conservatism in final foot placement by female participants accounts for the observed increase in distance from the critical boundary of the obstacle relative to toe placement. Behavioural effects of gender thus affect the control of final foot placement in obstacle-directed locomotion. The visual control of braking in target-directed locomotion is described by a tau-dot of-0.54. When tau-dot is below -0.54 a hard collision with the obstacle will occur, however, when tau-dot is above -0.54, a soft collision with the target will occur. It is suggested that the tau-dot margin defining the control of braking reveals the braking capacity of the system. In the target-directed locomotion examined a tau-dot greater than -0.70 would possibly exceed the braking capacity of the system, thus, leading to injury if performed. The approach towards the take-off board and vaulting horse in gymnastics is an example of target-directed locomotion in sport. Increased visual regulation of the timing and length of each step is a requirement for a fast running approach, a fundamental building block for the execution of complex vaults in gymnastics. The successful performance of complex vaults in gymnastics leads towards a higher judge's score. Future research suggestions include an investigation of visual regulation of step length in curved target-directed locomotion.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tensile tests at high speeds corresponding to automotive crash events were conducted to understand the dynamic properties of rapidly cured woven carbon fiber composites. The High Strain Rate (HSR) experiments were conducted on a servo-hydraulic machine at constant velocities up to a maximum of 25 m/s (82 ft/s). Results from HSR tests were compared with the static results to determine the rate sensitivity of the composite. A high speed camera was used to capture the failure at HSR. The tensile properties of rapidly cured laminate were compared to oven cured laminate to justify its productivity while maintaining the desired properties. The methodology used to achieve constant velocity during HSR tests is discussed in detail. The specimen geometry was specially designed to suit the test rig and to achieve high speeds during tests. All the specimens failed with linear elasticity until sudden brittle fracture. The Scanning Electron Microscopy (SEM) images of the fracture zone were used to identify the failure modes observed at static and high strain rates.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This article correlates laboratory-based understanding in machining of titanium alloys with the industry based outputs and finds possible solutions to improve machining efficiency of titanium alloy Ti-6Al-4V. The machining outputs are explained based on different aspects of chip formation mechanism and practical issues faced by industries during titanium machining. This study also analyzed and linked the methods that effectively improve the machinability of titanium alloys. It is found that the deformation mechanism during machining of titanium alloys is complex and causes basic challenges, such as sawtooth chips, high temperature, high stress on cutting tool, high tool wear and undercut parts. These challenges are correlated and affected by each other. Sawtooth chips cause variation in cutting forces which results in high cyclic stress on cutting tools. On the other hand, low thermal conductivity of titanium alloy causes high temperature. These cause a favorable environment for high tool wear. Thus, improvements in machining titanium alloy depend mainly on overcoming the complexities associated with the inherent properties of this alloy. Vibration analysis kit, high pressure coolant, cryogenic cooling, thermally enhanced machining, hybrid machining and, use of high conductive cutting tool and tool holders improve the machinability of titanium alloy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O Mercado Acionário Americano evoluiu rapidamente na última década. Este tornou-se uma arquitetura aberta em que participantes com tecnologia inovadora podem competir de forma eficaz. Várias mudanças regulatórias e inovações tecnológicas permitiram mudanças profundas na estrutura do mercado. Essas mudanças, junto com o desenvolvimento tecnológico de redes de alta velocidade, agiu como um catalisador, dando origem a uma nova forma de negociação, denominada Negociação em Alta Frequência (HFT). As empresas de HFT surgiram e se apropriaram em larga escala do negócio de formação de mercado, no fornecimento de liquidez. Embora HFT tem crescido massivamente, ao longo dos últimos quatro anos, HFT perdeu rentabilidade significativamente, uma vez que mais empresas aderiram ao setor reduzindo as margens. Portanto, diante deste contexto, esta tese buscou apresentar uma breve revisão sobre a atividade de HFT, seguida de uma análise dos limites deste setor, bem como, das características do macroambiente do HFT. Para tanto, a tese realizou uma extensa revisão do histórico literário, documentos públicos qualitativos, tais como, jornais, atas de reunião e relatórios oficiais. A tese empregou um ferramental de análise, Barreiras de Entrada e Mobilidade (Porter, 1980); Modelos de Evolução Setorial (McGahan, 2004); Estrutura do Setor de Informação Intensiva (Sampler, 1998), para analisar os limites do setor de HFT. Adicionalmente, empregou as ferramentas de análise, Modelos de Evolução Setorial (McGahan, 2004) e PESTEL (JOHNSON, SCHOLES, and WHITTINGTON, 2011), para analisar o setor e o contexto que envolve o negócio de HFT. A análise concluiu que as empresas que empregam HFT para atuar e competir no mercado acionário, compoem um setor independente.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Oral and facial bone defects can undertake appearance, psychosocial well-being and stomathognatic function of its patients. Over the yerars several strategies for bone defect regeneration have arised to treat these pathologies, among them the use of frozen and irradiated bone allograft. Manipulation of bone grafts it s not determined yet, and several osteotomy alternatives can be observed. The present work evaluated with a microscope the bone fragments obtained from different osteotomy methods and irrigation on rings and blocks allografts irradiated and frozen at 80° negative in a rabbit model. The study is experimental in vitro and it sample was an adult male New Zealand rabbit. The animal was sacrificed to obtain long bones, that were submitted to freezing at 80º negative and irradiated with Cobalt- 60. Then the long bones were sectioned into 24 bone pieces, divided into 4 groups: G1 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thickness with high-speed handpiece with manual irrigation; G2 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thick with surgical motor with a manual irrigation rotation 1500 rpm; GA (n=06), osteotomy with trephine using manual irrigation with saline; and GB (n=06), osteotomy with trephine using saline from peristaltic pumps of surgical motor. Five bone pieces of each group were prepared for analysis on light microscopy (LM) and one on electronic scan electronic microscopy (SEM). On the SEM analysis edges surface, presence of microcracks and Smear Layer were evaluated. Analyzing osteotomy technics on SEM was observed: increased presence of microcracks cutting with high speed; increased presence of areas covered by Smear Layer when cutting with motor implant. The irrigation analysis with SEM was observed: that the presence of microcracks does not depend on the type of irrigation; on manual irrigation, there was greater discrepancy between the cutting lines. The descriptive analysis of the osteotomy and irrigation process on LM showed: histological analysis showing the bony margins with clear tissue changed layer, composed of blackened tissue of charred appearance near to the cortical bone; on the edges of the bony part, bone fragments that were displaced during the bone cut and bone irregularities were observed. After analysis of results we can conclude: that there was greater regularity of the bone cut using high-speed handpiece than using motor implant; the cut with trephine using saline irrigated from peristaltic pumps of surgical motor showed greater homogeneity when compared with manual irrigation; charred tissue was found in all obtained bone samples, whit no significant statistically difference on the proportion of carbonization of the two analysed technics

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Com o grande crescimento tecnológico e a necessidade de melhoria, um dos materiais que ganhou uma grande gama na área da engenharia mecânica é a cerâmica, pois possui vantagens físico-químicas e propriedades mecânicas significativas sobre o aço. Entretanto, sua usinagem é um processo difícil e delicado, que requer ainda uma grande atenção em relação ao seu estudo. Assim, o processo de retificação é um dos métodos que tem apresentado bons resultados, porém um grande problema acerca de tal processo é o uso excessivo de fluidos de corte, o que se tornou uma preocupação mundial, já que os fluidos apresentam graves problemas socioambientais, além disso, o fluido de corte é responsável por uma grande parte do custo final do processo, provocando, desse modo, um grande interesse em pesquisas referentes a métodos alternativos de forma a reduzir o consumo e melhorar as características do fluido de corte utilizado. Este trabalho visa comparar duas técnicas de lubri-refrigeração, o método convencional e a Lubrificação Otimizada. O uso do método otimizado é uma alternativa à diminuição do volume de fluido utilizado, já que este tem como princípio a aplicação de uma menor quantidade de fluido de corte com uma alta velocidade, localmente aplicada, ou seja, com essa redução benefícios ambientais e socioeconômicas são obtidos. A análise do trabalho será feita a partir da avaliação das variáveis de saída do processo de retificação plana tais como o comportamento rugosidade e desgaste do rebolo, já que por elas é possível avaliar o processo em relação a qualidade da peça versus custo. Com essas analises, pretende-se avaliar se a técnica otimizada é viável a substituição da refrigeração convencional na retificação plana de cerâmicas.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Quando qualquer instrumento abrasiona ou corta a dentina, produz na superfície uma camada de lama dentinária ou smear layer. Dependendo do agente de união indicado em Odontologia adesiva, há a necessidade ou não da remoção da camada de lama da superfície dentinária. Com a finalidade de verificar a ação de diferentes substâncias para a limpeza dentinária, utilizamos 20 dentes pré-molares superiores íntegros, mantidos em soro fisiológico, nos quais as coroas foram seccionadas ao meio no sentido mésio-distal. Com instrumento diamantado, removeu-se o esmalte da porção vestibular e da porção lingual da coroa e, com uma broca carbide cilíndrica lisa nº 56, cortou-se aproximadamente 1 mm de dentina com alta rotação sob abundante refrigeração ar/água, para produzir a camada de lama dentinária. em seguida, essa superfície foi tratada com diferentes substâncias e lavada por 30 segundos com spray ar/água. No controle, foi simplesmente utilizado o spray ar/água. Os espécimes foram montados em suportes metálicos, preparados e visualizados no MEV-DSM 950 da Zeiss, em aumentos que variaram de 100 a 5.000 vezes. Os materiais que mais removeram a camada de lama foram, em ordem crescente: 1. spray ar/água; 2. fluoreto de sódio 2%; 3. associação alternada de Dakin/Tergensol; 4. água oxigenada 3%; 5. jateamento com óxido de alumínio 50 mm; 6. flúor acidulado 1,27%; 7. ácido poliacrílico 25%; 8. ácido fosfórico 10%.