956 resultados para heart ventricle isometric contraction
Resumo:
The liver, heart and muscle tissues of Rohu, (Labeo rohita, Hamilton) were examined for their ubiquinone (UQ) and tocopherol contents. These three tissues contained respectively 11.60, 3.94 and 0.19 mg of ubiquinone and 10.16, 5.32 and 3.58 mg of tocopherol per 100 g. The 4% (V/V) of diethyl ether (EE) in light petroleum ether (PE) fractions of all three tissues on paper chromatographic separation gave spots having the same Rf value as standard ubiquinone-50 (UQ 10). Both the 4% and 6% (V/V) diethyl ether in light petroleum ether fraction of liver, heart and muscle tissues gave a single spot with the same Rf value as α – tocopherol.
Resumo:
The effect of AC and DC electric stimulations on the heart-rate and the entire body of Heteropneustis fossillis, Tilapia mossambica and Macrobrachium rosenbergii were studied and presented in kymograph tracings. The reaction of spinal cord in Puntius ticto, Heteropneustis fossilis and Tilapia mossambica to D. C. field was observed to find out its role in electric shocks. A test-check of the electrical resistance of a few species was also conducted. The effect of D. C. and A.C. on the body muscle was found to be the same as that in the case of frog. Different degrees of cardiac slowing were observed in AC and DC. Unbalanced galvanotropic movements were also noticed in spinal fishes.
Resumo:
The triglyceride fatty acid components from the heart lipid of Puntius sarana of different sizes have been characterized by thin-layer and gas liquid chromatography. Csub(10) to Csub(24) acids including both odd-numbered and branched chain acids were detected. The major constituents were ante-iso Csub(10), Csub(10), Csub(12:2), Csub(14), Csub(16), Csub(16:1),Csub(17), Csub(18) , Csub(18:1), Csub(18:2), Csub(18:3) and Csub(20:4) while twenty other acids were detected in lower proportion. The composition of these acids and their variation with size of fish have been investigated and discussed.
Resumo:
The effect of adenosine on the function of the heart in Octopus vulgaris was studied using an isolated heart preparation. Bolus injections of adenosine or AMP (adenosine precursor) induced both positive chronotropic and inotropic effects. The maximum inotropic effect preceded the maximum chronotropic effect. The impermeable adenosine analogue 2-chloroadenosine elicited a similar effect, while the adenosine uptake blocker dipyridamole did not affect the adenosine response. These results suggest that adenosine acted extracellularly. The concentration-response curves of adenosine and AMP were also determined, by evaluating the effects on ventricular and coronary function. Under these conditions, the potent chronotropic effect elicited by both substances apparently masked or compensated for the inotropic effect, owing to the negative force-frequency relationship known to occur in the octopus heart. The AMP displayed a lower threshold than adenosine, suggesting an higher affinity for the purinergic receptors involved or a strict association between 5'-nucleotidase and the adenosine receptor on the plasma membrane.
Resumo:
Tor mahseer (Tor tor), possess high commercial and recreational value as they are potential game as well as food fish of India. Two cell culture systems were developed from fin and heart of T. tor (Hamilton-Buchanan). The explants excised aseptically from fingerling of T. tor were cultured in Leibovitz-15 (L-15) medium with 20% fetal bovine serum (FBS). Radiation of cells started after 72 hours and 48 hours of explant attachment from caudal fin and heart respectively. Confluent monolayer of cells with heterogeneous morphology around fin explants was observed after 7-10 days, where as a homogenous confluent layer of fibroblastic cells from heart explant was observed after 12-13 days. The establishment of cell culture systems from different organs and tissues of commercial important species would facilitates in vitro research.
Resumo:
Two control algorithms have been developed for a minimally invasive axial-flow ventricular assist device (VAD) for placement in the descending aorta. The purpose of the device is to offload the left ventricle and to augment lower body perfusion in patients with moderate congestive heart failure. The VAD consists of an intra-aortic impeller with a built-in permanent magnet rotor and an extra-aortic stator. The control algorithms, which use pressure readings upstream and downstream of the VAD to determine the pump status, have been tested in a mock circulatory system under two conditions, namely with or without afterload sensitivity. The results give an insight into controller design for an intra-aortic blood pump working in series with the heart.
Resumo:
A permanent-magnet motor has been designed for an innovative axial-flow ventricular assist device (VAD), to be placed in the descending aorta, intended to offload the left ventricle and augment renal perfusion in patients with congestive heart failure (CHF). For this application, an intra-aortic impeller with a built-in permanent magnet rotor is driven by an extraaortic stator working in synchronism with the natural heart. To meet this need, a two-dimensional analytical model has been developed in the MATLAB environment to estimate machine parameters; finite element analysis (FEA) has been used to refine the results. A prototype blood pump equipped with an innovative motor designed from the procedure above has been tested in a mock loop representing the human circulatory system. The performance of VAD incorporating the motor is presented. © 2009 IEEE.
Resumo:
Atlases and statistical models play important roles in the personalization and simulation of cardiac physiology. For the study of the heart, however, the construction of comprehensive atlases and spatio-temporal models is faced with a number of challenges, in particular the need to handle large and highly variable image datasets, the multi-region nature of the heart, and the presence of complex as well as small cardiovascular structures. In this paper, we present a detailed atlas and spatio-temporal statistical model of the human heart based on a large population of 3D+time multi-slice computed tomography sequences, and the framework for its construction. It uses spatial normalization based on nonrigid image registration to synthesize a population mean image and establish the spatial relationships between the mean and the subjects in the population. Temporal image registration is then applied to resolve each subject-specific cardiac motion and the resulting transformations are used to warp a surface mesh representation of the atlas to fit the images of the remaining cardiac phases in each subject. Subsequently, we demonstrate the construction of a spatio-temporal statistical model of shape such that the inter-subject and dynamic sources of variation are suitably separated. The framework is applied to a 3D+time data set of 138 subjects. The data is drawn from a variety of pathologies, which benefits its generalization to new subjects and physiological studies. The obtained level of detail and the extendability of the atlas present an advantage over most cardiac models published previously. © 1982-2012 IEEE.
Resumo:
Recent studies have demonstrated a role for the elastic protein titin in active muscle, but the mechanisms by which titin plays this role remain to be elucidated. In active muscle, Ca(2+)-binding has been shown to increase titin stiffness, but the observed increase is too small to explain the increased stiffness of parallel elastic elements upon muscle activation. We propose a 'winding filament' mechanism for titin's role in active muscle. First, we hypothesize that Ca(2+)-dependent binding of titin's N2A region to thin filaments increases titin stiffness by preventing low-force straightening of proximal immunoglobulin domains that occurs during passive stretch. This mechanism explains the difference in length dependence of force between skeletal myofibrils and cardiac myocytes. Second, we hypothesize that cross-bridges serve not only as motors that pull thin filaments towards the M-line, but also as rotors that wind titin on the thin filaments, storing elastic potential energy in PEVK during force development and active stretch. Energy stored during force development can be recovered during active shortening. The winding filament hypothesis accounts for force enhancement during stretch and force depression during shortening, and provides testable predictions that will encourage new directions for research on mechanisms of muscle contraction.
Resumo:
As part of the investigations into a surgical incident involving the accidental retention inside a patient's venous system of a guide wire for central venous catheterisation (CVC), the Human Error Assessment and Reduction Technique (HEART) was used to examine the potential for further occurrences. It was found to be time-efficient and to yield plausible probabilities of human error, although its use in healthcare has challenges, suggesting adaptation would be beneficial.
Resumo:
This paper establishes a global contraction property for networks of phase-coupled oscillators characterized by a monotone coupling function. The contraction measure is a total variation distance. The contraction property determines the asymptotic behavior of the network, which is either finite-time synchronization or asymptotic convergence to a splay state. © 2012 Elsevier B.V. All rights reserved.
Resumo:
We consider the problem of positive observer design for positive systems defined on solid cones in Banach spaces. The design is based on the Hilbert metric and convergence properties are analyzed in the light of the Birkhoff theorem. Two main applications are discussed: positive observers for systems defined in the positive orthant, and positive observers on the cone of positive semi-definite matrices with a view on quantum systems. © 2011 IEEE.