968 resultados para coronary blood vessel


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this study was to evaluate associations between aortic pulse wave velocity (PWV) and aortic and carotid vessel wall thickness (VWT) using cardiovascular magnetic resonance imaging (MRI) in patients with hypertension as compared with healthy adult volunteers. MATERIALS AND METHODS: Local medical ethics approval was obtained and the participants gave informed consent. Fifteen patients with hypertension (5 men and 10 women; mean [SD] age, 49 [14] years) and 15 age- and sex-matched healthy volunteers were prospectively included and compared. All participants underwent MRI examination for measuring aortic and carotid VWT and aortic PWV with well-validated MRI techniques at 1.5- and 3-T MRI systems: PWV was assessed from velocity-encoded MRI and VWT was assessed by using dual-inversion black-blood gradient-echo imaging techniques. Paired t tests were used for testing differences between the volunteers and the patients and Pearson correlation (r) and univariable and multivariable stepwise linear regression analyses were used to test associations between aortic and carotid arterial wall thickness and stiffness. RESULTS: Mean values for aortic PWV and aortic and carotid VWT (indexed for body surface area [BSA]) were all significantly higher in patients with hypertension as compared with the healthy volunteers (ie, aortic PWV, 7.0 ± 1.4 m/s vs 5.7 ± 1.3 m/s; aortic VWT/BSA, 0.12 ± 0.03 mL/m vs 0.10 ± 0.03 mL/m; carotid VWT/BSA, 0.04 ± 0.01 mL/m vs 0.03 ± 0.01 mL/m; all P < 0.01). Aortic PWV was highly correlated with aortic VWT/BSA (r = 0.76 and P = 0.002 in the patients vs r = 0.63 and P = 0.02 in the volunteers), and in the patients, aortic PWV was moderately correlated with carotid VWT/BSA (r = 0.50; P = 0.04). In the volunteers, correlation between aortic PWV and carotid VWT/BSA was not significant (r = 0.40; P = 0.13). In addition, aortic VWT/BSA was significantly correlated with carotid VWT/BSA, in both the patients (r = 0.60; P = 0.005) and volunteers (r = 0.57; P = 0.007). CONCLUSIONS: In the patients with hypertension and the healthy volunteers, the aortic PWV is associated more strongly with aortic wall thickness than with carotid wall thickness, reflecting site-specific coupling between vascular wall thickness and function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Dual-inversion recovery (DIR) is widely used for magnetic resonance vessel wall imaging. However, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. Therefore, an extension of phase-sensitive (PS) DIR is proposed for carotid vessel wall imaging. METHODS: The statistical distribution of the phase signal after DIR is probed to segment carotid lumens and suppress their residual blood signal. The proposed PS-DIR technique was characterized over a broad range of inversion times. Multislice imaging was then implemented by interleaving the acquisition of 3 slices after DIR. Quantitative evaluation was then performed in healthy adult subjects and compared with conventional DIR imaging. RESULTS: Single-slice PS-DIR provided effective blood-signal suppression over a wide range of inversion times, enhancing wall-lumen contrast and vessel wall conspicuity for carotid arteries. Multislice PS-DIR imaging with effective blood-signal suppression is enabled. CONCLUSIONS: A variant of the PS-DIR method has successfully been implemented and tested for carotid vessel wall imaging. This technique removes timing constraints related to inversion recovery, enhances wall-lumen contrast, and enables a 3-fold increase in volumetric coverage at no extra cost in scanning time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To study the influence of retinal structural changes on oxygen saturation in retinitis pigmentosa (RP) patients. METHODS: Oximetry measurements were performed on 21 eyes of 11 RP patients and compared to 24 eyes of 12 controls. Retinal oxygen saturation was measured in all major retinal arterioles (A-SO₂) and venules (V-SO₂) with an oximetry unit of the retinal vessel analyser (IMEDOS Systems UG, Jena, Germany). Oximetry data were compared with morphological changes measured by Cirrus optical coherence tomography (OCT) (Carl Zeiss Meditec, Dublin, CA, USA, macular thickness protocol). RESULTS: In RP patients, the retinal A-SO₂ and V-SO₂ levels were higher at 99.3% (p = 0.001, anova based on mixed-effects model) and 66.8% (p < 0.001), respectively, and the difference between the two (A-V SO₂) was lower at 32.5% (p < 0.001), when compared to the control group (92.4%; 54.0%; 38.4%, respectively). With the RP group, the A-V SO₂ correlated positively, not only with central macular thickness, but also with retinal thickness, in zones 2 and 3 (p = 0.006, p = 0.007, p = 0.014). CONCLUSION: These data indicate that oxygen metabolism was altered in RP patients. Based on our preliminary results, retinal vessel saturation correlated with structural alterations in RP. This method could be valuable in monitoring disease progression and evaluating a potential therapeutic response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Atherosclerosis results in a considerable medical and socioeconomic impact on society. We sought to evaluate novel magnetic resonance imaging (MRI) angiography and vessel wall sequences to visualize and quantify different morphologic stages of atherosclerosis in a Watanabe hereditary hyperlipidemic (WHHL) rabbit model. MATERIAL AND METHODS: Aortic 3D steady-state free precession angiography and subrenal aortic 3D black-blood fast spin-echo vessel wall imaging pre- and post-Gadolinium (Gd) was performed in 14 WHHL rabbits (3 normal, 6 high-cholesterol diet, and 5 high-cholesterol diet plus endothelial denudation) on a commercial 1.5 T MR system. Angiographic lumen diameter, vessel wall thickness, signal-/contrast-to-noise analysis, total vessel area, lumen area, and vessel wall area were analyzed semiautomatically. RESULTS: Pre-Gd, both lumen and wall dimensions (total vessel area, lumen area, vessel wall area) of group 2 + 3 were significantly increased when compared with those of group 1 (all P < 0.01). Group 3 animals had significantly thicker vessel walls than groups 1 and 2 (P < 0.01), whereas angiographic lumen diameter was comparable among all groups. Post-Gd, only diseased animals of groups 2 + 3 showed a significant (>100%) signal-to-noise ratio and contrast-to-noise increase. CONCLUSIONS: A combination of novel 3D magnetic resonance angiography and high-resolution 3D vessel wall MRI enabled quantitative characterization of various atherosclerotic stages including positive arterial remodeling and Gd uptake in a WHHL rabbit model using a commercially available 1.5 T MRI system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND/AIMS: The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. METHODS: Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. RESULTS: Functional analysis showed a significant decrease in global left ventricular ejection fraction (24.5 +/- 1.6%) 3 weeks after implantation. There was a trend to increased left ventricular ejection fraction after low-dose dobutamine stress (36.0 +/- 6.6%) and a significant improvement of the impaired regional anterior wall motion. PET and SPECT imaging documented chronic hibernation. Myocardial fibrosis increased significantly in the ischemic area with a gradient from epi- to endocardial. The number of arterial vessels in the ischemic area increased and coronary angiography showed abundant collateral vessels of Rentrop class 1. CONCLUSION: The presented experimental model mimics the clinical situation of chronic myocardial ischemia secondary to 1-vessel coronary disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditionally, thoracic aortic rupture, suspected after blunt thoracic trauma, is characterized by a chest radiograph showing a widened mediastinum. The diagnostic machinery consecutively activated still depends heavily on the pressure as additional traumatic lesions. A patient with additional cranio-cerebral trauma would typically undergo contrast-enhanced computed tomography or magnetic resonance imaging of head, chest, and other regions. In a number of patients these analyses would confirm the presence of blood in the mediastinum without formal proof of an aortic disruption. This is because mediastinal hematomas may be caused not only by an aortic rupture, but also by numerous other blood sources including fractures of the spine and other macro- and microvascular lesions providing similar images. Therefore, aortic angiography became our preferred diagnostic tool to identify or rule out acute traumatic lesions of not only the aorta but with great vessels. However recently, a number of traumatic aortic transsections have been identified by transoesophageal echocardiography (TEE). TEE has the additional advantage of being a bed-side procedure providing additional information about cardiac function. The latter analysis allows for identification and quantification of cardiac contusions, post-traumatic myocardial infarctions, and valvar lesions which are of prime importance to develop an adequate surgical strategy and to assess the risk of the numerous emergency procedures required in patients with polytrauma. The standard approach for repair of isthmic aortic rupture is through a lateral thoracotomy. Distal and proximal control of the aorta can be achieved in a substantial number of cases before complete aortic rupture occurs and a higher proportion of direct suture repair can be achieved under such circumstances. Most proximal descending aortic procedures are performed without cardiopulmonary bypass (clamp and go) but paraplegia may occur before, during, or after the procedure. Ascending aortic lesions and disruption of the aortic arch, the supra-aortic vessels, the main pulmonary arteries, the great veins as well as cardiac lesions are best approached through a sternotomy, which may have to be extended. Cardiopulmonary bypass allowing for deep hypothermia and circulatory arrest is often required and carries its own complications. It is not clear whether the increasing proportion of ascending aortic and cardiac lesions which are observed nowadays are due to a change in trauma mechanics (i.e., speed limits, seat belts, air-bags), an improvement of the diagnostic tools or both.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

25 patients with acute myocardial infarction pain lasting more than 20 minutes which was not relieved by nitrates, whose ECGs showed ST segment elevations of 1 mm or more in 2 or more ECG leads, and who presented less than 3 hours after onset of their symptoms were randomly assigned to one of 2 thrombolytic treatment groups: a single intravenous bolus of anisoylated plasminogen streptokinase activator complex (APSAC) 30U in 5 minutes or an intravenous infusion of streptokinase 1,500,000U over 60 minutes. 3 to 4 hours after the administration of the thrombolytic agent, all patients received intravenous heparin at full dosage for 24 hours. The patency of the infarct-related coronary vessels was assessed by angiography 1 to 4 hours after administration of the thrombolytic agent. Clinical signs, ECGs, pulse, blood pressure and temperature were monitored regularly for 24 hours after treatment or as clinically appropriate. APSAC seemed to be at least as effective as streptokinase in terms of patency of the infarct-related vessel (92% vs 63%, respectively). The adverse events were similar and none was life-threatening. APSAC and streptokinase caused similar falls in blood fibrinogen levels. APSAC, given as a bolus injection over 5 minutes, was easier to administer than streptokinase, which was given as an infusion during 60 minutes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Exposure to combination antiretroviral therapy (cART) can lead to important metabolic changes and increased risk of coronary heart disease (CHD). Computerized clinical decision support systems have been advocated to improve the management of patients at risk for CHD but it is unclear whether such systems reduce patients' risk for CHD. METHODS: We conducted a cluster trial within the Swiss HIV Cohort Study (SHCS) of HIV-infected patients, aged 18 years or older, not pregnant and receiving cART for >3 months. We randomized 165 physicians to either guidelines for CHD risk factor management alone or guidelines plus CHD risk profiles. Risk profiles included the Framingham risk score, CHD drug prescriptions and CHD events based on biannual assessments, and were continuously updated by the SHCS data centre and integrated into patient charts by study nurses. Outcome measures were total cholesterol, systolic and diastolic blood pressure and Framingham risk score. RESULTS: A total of 3,266 patients (80% of those eligible) had a final assessment of the primary outcome at least 12 months after the start of the trial. Mean (95% confidence interval) patient differences where physicians received CHD risk profiles and guidelines, rather than guidelines alone, were total cholesterol -0.02 mmol/l (-0.09-0.06), systolic blood pressure -0.4 mmHg (-1.6-0.8), diastolic blood pressure -0.4 mmHg (-1.5-0.7) and Framingham 10-year risk score -0.2% (-0.5-0.1). CONCLUSIONS: Systemic computerized routine provision of CHD risk profiles in addition to guidelines does not significantly improve risk factors for CHD in patients on cART.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Vorapaxar is a new oral protease-activatedreceptor 1 (PAR-1) antagonist that inhibits thrombin-induced platelet activation. Methods: In this multinational, double-blind, randomized trial, we compared vorapaxar with placebo in 12,944 patients who had acute coronary syndromes without ST-segment elevation. The primary end point was a composite of death from cardiovascular causes, myocardial infarction, stroke, recurrent ischemia with rehospitalization, or urgent coronary revascularization. RESULTS: Follow-up in the trial was terminated early after a safety review. After a median follow-up of 502 days (interquartile range, 349 to 667), the primary end point occurred in 1031 of 6473 patients receiving vorapaxar versus 1102 of 6471 patients receiving placebo (KaplanMeier 2-year rate, 18.5% vs. 19.9%; hazard ratio, 0.92; 95% confidence interval [CI], 0.85 to 1.01; P = 0.07). A composite of death from cardiovascular causes, myocardial infarction, or stroke occurred in 822 patients in the vorapaxar group versus 910 in the placebo group (14.7% and 16.4%, respectively; hazard ratio, 0.89; 95% CI, 0.81 to 0.98; P = 0.02). Rates of moderate and severe bleeding were 7.2% in the vorapaxar group and 5.2% in the placebo group (hazard ratio, 1.35; 95% CI, 1.16 to 1.58; P<0.001). Intracranial hemorrhage rates were 1.1% and 0.2%, respectively (hazard ratio, 3.39; 95% CI, 1.78 to 6.45; P<0.001). Rates of nonhemorrhagic adverse events were similar in the two groups. Conclusions: In patients with acute coronary syndromes, the addition of vorapaxar to standard therapy did not significantly reduce the primary composite end point but significantly increased the risk of major bleeding, including intracranial hemorrhage. (Funded by Merck; TRACER ClinicalTrials.gov number, NCT00527943.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to characterize myocardial infarction after percutaneous coronary intervention (PCI) based on cardiac marker elevation as recommended by the new universal definition and on the detection of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR). It is also assessed whether baseline inflammatory biomarkers are higher in patients developing myocardial injury. BACKGROUND: Cardiovascular magnetic resonance accurately assesses infarct size. Baseline C-reactive protein (CRP) and neopterin predict prognosis after stent implantation. METHODS: Consecutive patients with baseline troponin (Tn) I within normal limits and no LGE in the target vessel underwent baseline and post-PCI CMR. The Tn-I was measured until 24 h after PCI. Serum high-sensitivity CRP and neopterin were assessed before coronary angiography. RESULTS: Of 45 patients, 64 (53 to 72) years of age, 33% developed LGE with infarct size of 0.83 g (interquartile range: 0.32 to 1.30 g). A Tn-I elevation >99% upper reference limit (i.e., myocardial necrosis) (median Tn-I: 0.51 μg/l, interquartile range: 0.16 to 1.23) and Tn-I > 3× upper reference limit (i.e., type 4a myocardial infarction [MI]) occurred in 58% and 47% patients, respectively. LGE was undetectable in 42% and 43% of patients with periprocedural myocardial necrosis and type 4a MI, respectively. Agreement between LGE and type 4a MI was moderate (kappa = 0.45). The levels of CRP or neopterin did not significantly differ between patients with or without myocardial injury, detected by CMR or according to the new definition (p = NS). CONCLUSIONS: This study reports the lack of substantial agreement between the new universal definition and CMR for the diagnosis of small-size periprocedural myocardial damage after complex PCI. Baseline levels of CRP or neopterin were not predictive for the development of periprocedural myocardial damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.