949 resultados para XML optimisation
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
Resumo:
Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.
Resumo:
Patients scheduled for a magnetic resonance imaging (MRI) scan sometimes require screening for ferromagnetic Intra Orbital Foreign Bodies (IOFBs). To assess this, they are required to fill out a screening protocol questionnaire before their scan. If it is established that a patient is at high risk, radiographic imaging is necessary. This review examines literature to evaluate which imaging modality should be used to screen for IOFBs, considering that the eye is highly sensitive to ionising radiation and any dose should be minimised. Method: Several websites and books were searched for information, these were as follows: PubMed, Science Direct, Web of Knowledge and Google Scholar. The terms searched related to IOFB, Ionising radiation, Magnetic Resonance Imaging Safety, Image Quality, Effective Dose, Orbits and X-ray. Thirty five articles were found, several were rejected due to age or irrelevance; twenty eight were eventually accepted. Results: There are several imaging techniques that can be used. Some articles investigated the use of ultrasound for investigation of ferromagnetic IOFBs of the eye and others discussed using Computed Tomography (CT) and X-ray. Some gaps in the literature were identified, mainly that there are no articles which discuss the lowest effective dose while having adequate image quality for orbital imaging. Conclusion: X-ray is the best method to identify IOFBs. The only problem is that there is no research which highlights exposure factors that maintain sufficient image quality for viewing IOFBs and keep the effective dose to the eye As Low As Reasonably Achievable (ALARA).
Resumo:
Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.
Resumo:
Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients.
Resumo:
Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.
Resumo:
This paper reviews the literature for lowering of dose to paediatric patients through use of exposure factors and additional filtration. Dose reference levels set by The International Commission on Radiological Protection (ICRP) will be considered. Guidance was put in place in 1996 requires updating to come into line with modern imaging equipment. There is a wide range of literature that specifies that grids should not be used on paediatric patients. Although much of the literature advocates additional filtration, contrasting views on the relative benefits of using aluminium or copper filtration, and their effects on dose reduction and image quality can vary. Changing kVp and mAs has an effect on the dose to the patient and image quality. Collimation protects adjacent structures whilst reducing scattered radiation.
Resumo:
Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.
Resumo:
Rationale and Objectives Computer-aided detection and diagnosis (CAD) systems have been developed in the past two decades to assist radiologists in the detection and diagnosis of lesions seen on breast imaging exams, thus providing a second opinion. Mammographic databases play an important role in the development of algorithms aiming at the detection and diagnosis of mammary lesions. However, available databases often do not take into consideration all the requirements needed for research and study purposes. This article aims to present and detail a new mammographic database. Materials and Methods Images were acquired at a breast center located in a university hospital (Centro Hospitalar de S. João [CHSJ], Breast Centre, Porto) with the permission of the Portuguese National Committee of Data Protection and Hospital's Ethics Committee. MammoNovation Siemens full-field digital mammography, with a solid-state detector of amorphous selenium was used. Results The new database—INbreast—has a total of 115 cases (410 images) from which 90 cases are from women with both breasts affected (four images per case) and 25 cases are from mastectomy patients (two images per case). Several types of lesions (masses, calcifications, asymmetries, and distortions) were included. Accurate contours made by specialists are also provided in XML format. Conclusion The strengths of the actually presented database—INbreast—relies on the fact that it was built with full-field digital mammograms (in opposition to digitized mammograms), it presents a wide variability of cases, and is made publicly available together with precise annotations. We believe that this database can be a reference for future works centered or related to breast cancer imaging.
Resumo:
O objectivo da tese é demonstrar a adequação do paradigma dos mercados electrónicos baseados em agentes para transaccionar objectos multimédia em função do perfil dos espectadores. Esta dissertação descreve o projecto realizado no âmbito da plataforma de personalização de conteúdos em construção. O domínio de aplicação adoptado foi a personalização dos intervalos publicitários difundidos pelos distribuidores de conteúdos multimédia, i.e., pretende-se gerar em tempo útil o alinhamento de anúncios publicitários que melhor se adeqúe ao perfil de um espectador ou de um grupo de espectadores. O projecto focou-se no estudo e selecção das tecnologias de suporte, na concepção da arquitectura e no desenvolvimento de um protótipo que permitisse realizar diversas experiências nomeadamente com diferentes estratégias e tipos de mercado. A arquitectura proposta para a plataforma consiste num sistema multiagente organizado em três camadas que disponibiliza interfaces do tipo serviço Web com o exterior. A camada de topo é constituída por agentes de interface com o exterior. Na camada intermédia encontram-se os agentes autónomos que modelam as entidades produtoras e consumidoras de componentes multimédia assim como a entidade reguladora do mercado. Estes agentes registam-se num serviço de registo próprio onde especificam os componentes multimédia que pretendem negociar. Na camada inferior realiza-se o mercado que é constituído por agentes delegados dos agentes da camada superior. O lançamento do mercado é efectuado através de uma interface e consiste na escolha do tipo de mercado e no tipo de itens a negociar. Este projecto centrou-se na realização da camada do mercado e da parte da camada intermédia de apoio às actividades de negociação no mercado. A negociação é efectuada em relação ao preço da transmissão do anúncio no intervalo em preenchimento. Foram implementados diferentes perfis de negociação com tácticas, incrementos e limites de variação de preço distintos. Em termos de protocolos de negociação, adoptou-se uma variante do Iterated Contract Net – o Fixed Iterated Contract Net. O protótipo resultante foi testado e depurado com sucesso.
Resumo:
Esta dissertação apresenta uma proposta de sistema capaz de preencher a lacuna entre documentos legislativos em formato PDF e documentos legislativos em formato aberto. O objetivo principal é mapear o conhecimento presente nesses documentos de maneira a representar essa coleção como informação interligada. O sistema é composto por vários componentes responsáveis pela execução de três fases propostas: extração de dados, organização de conhecimento, acesso à informação. A primeira fase propõe uma abordagem à extração de estrutura, texto e entidades de documentos PDF de maneira a obter a informação desejada, de acordo com a parametrização do utilizador. Esta abordagem usa dois métodos de extração diferentes, de acordo com as duas fases de processamento de documentos – análise de documento e compreensão de documento. O critério utilizado para agrupar objetos de texto é a fonte usada nos objetos de texto de acordo com a sua definição no código de fonte (Content Stream) do PDF. A abordagem está dividida em três partes: análise de documento, compreensão de documento e conjunção. A primeira parte da abordagem trata da extração de segmentos de texto, adotando uma abordagem geométrica. O resultado é uma lista de linhas do texto do documento; a segunda parte trata de agrupar os objetos de texto de acordo com o critério estipulado, produzindo um documento XML com o resultado dessa extração; a terceira e última fase junta os resultados das duas fases anteriores e aplica regras estruturais e lógicas no sentido de obter o documento XML final. A segunda fase propõe uma ontologia no domínio legal capaz de organizar a informação extraída pelo processo de extração da primeira fase. Também é responsável pelo processo de indexação do texto dos documentos. A ontologia proposta apresenta três características: pequena, interoperável e partilhável. A primeira característica está relacionada com o facto da ontologia não estar focada na descrição pormenorizada dos conceitos presentes, propondo uma descrição mais abstrata das entidades presentes; a segunda característica é incorporada devido à necessidade de interoperabilidade com outras ontologias do domínio legal, mas também com as ontologias padrão que são utilizadas geralmente; a terceira característica é definida no sentido de permitir que o conhecimento traduzido, segundo a ontologia proposta, seja independente de vários fatores, tais como o país, a língua ou a jurisdição. A terceira fase corresponde a uma resposta à questão do acesso e reutilização do conhecimento por utilizadores externos ao sistema através do desenvolvimento dum Web Service. Este componente permite o acesso à informação através da disponibilização de um grupo de recursos disponíveis a atores externos que desejem aceder à informação. O Web Service desenvolvido utiliza a arquitetura REST. Uma aplicação móvel Android também foi desenvolvida de maneira a providenciar visualizações dos pedidos de informação. O resultado final é então o desenvolvimento de um sistema capaz de transformar coleções de documentos em formato PDF para coleções em formato aberto de maneira a permitir o acesso e reutilização por outros utilizadores. Este sistema responde diretamente às questões da comunidade de dados abertos e de Governos, que possuem muitas coleções deste tipo, para as quais não existe a capacidade de raciocinar sobre a informação contida, e transformá-la em dados que os cidadãos e os profissionais possam visualizar e utilizar.
Resumo:
The latest medical diagnosis devices enable the performance of e-diagnosis making the access to these services easier, faster and available in remote areas. However this imposes new communications and data interchange challenges. In this paper a new XML based format for storing cardiac signals and related information is presented. The proposed structure encompasses data acquisition devices, patient information, data description, pathological diagnosis and waveform annotation. When compared with similar purpose formats several advantages arise. Besides the full integrated data model it may also be noted the available geographical references for e-diagnosis, the multi stream data description, the ability to handle several simultaneous devices, the possibility of independent waveform annotation and a HL7 compliant structure for common contents. These features represent an enhanced integration with existent systems and an improved flexibility for cardiac data representation.
Resumo:
Current Learning Management Systems focus on the management of students, keeping track of their progress across all types of training activities. This type of systems lacks integration with other e-Learning systems. For instance, learning objects stored in a centralized repository are unavailable throughout an organization for potential reuse. In this paper we present the interoperability features of crimsonHex - a service oriented repository of learning objects - highlighting the use of XML languages. Its nteroperability features are compliant with the existing standards and we propose extensions to the IMS interoperability recommendation, adding new functions, formalizing an XML message interchange and providing also a REST interface. To validate the proposed extensions and its implementation in crimsonHex we designed two repository plugins for Moodle 2.0, the first of which is already implemented and is expected to be included in the next release of this popular learning management system.
Resumo:
Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Ciência e Sistemas de Informação Geográfica
Resumo:
São vários os factores sociais e económicos que valorizam a aplicação de tecnologias de domótica em edifícios. No caso particular dos edifícios residenciais, a tendência dos seus utilizadores é a instalação de sistemas de controlo da segurança, do ambiente, de mecanismos de rega e de alarmes. Assim, seguindo a premissa do marketing, que identifica como uma boa prática a projecção de produtos / serviços que satisfaçam as necessidades inventariadas pelos seus utilizadores, este trabalho assenta na criação de um sistema domótico, controlado remotamente através de uma aplicação Android, que pretende, numa primeira instância, o controlo das lâmpadas de uma habitação. Neste trabalho é utilizado o protocolo KNX.TP para a comunicação dos dispositivos de domótica existentes no ISEP, que constituem o ambiente domótico deste trabalho. De forma a implementar o controlo remoto destes dispositivos via internet, este trabalho foca-se no desenvolvimento de uma interface IP-KNX, usando como hardware de controlo, um Arduino Mega 2560, uma placa de interface Ethernet para Arduino, a placa de integração KNX, e um servidor web com a linguagem PHP instalada. Para efeitos de demonstração, foi criada uma aplicação para o SO Android que controla as lâmpadas da rede KNX. Neste trabalho foram utilizadas várias linguagens de programação: C++ no firmware do Arduino, PHP no servidor web e JAVA + XML na aplicação Android.