766 resultados para Welding fixture
Resumo:
The conventional radiographic technique using industrial radiographic films is with the days finishing. The Digital Radiography is taking place in several sectors, e.g., the medical, aerospace, security, automotive, etc. In addition to representing a technological trend, it has been demonstrated that digital radiography offers a series of benefits in terms of productivity, sensitivity, environmental aspects, image treatment tools, cost reduction, etc. If one weld seam to be inspected is from a serried product, as example a pipe, the best option to be implemented is the Flat Panel Detector with this equipment is possible to reduce the obtaining digital radiographic images in place of films and reducing the inspection cycle time due to its high degree of automation. In the experiments described in this paper this new technique was tested and the results were compared with those obtained by the conventional radiography. The welded specimens were prepared using the submerged-arc welding process and small artificial cracks of the most varied dimensions, present in the specimens, were used to establish a comparison of the sensitivities presented by the techniques employed After conducting several experiments, the digital method presented the highest sensitivity to the wire-type Image Quality Indicator (IQI) and in the detection of small defects, leading to the conclusion that the use of digital radiography using the flat-panel detector offers advantages over the conventional technique [1, 2]. This work was carried out based on the API 5L Edition 2004 [3] and ISO 3183 Edition 2007 [4] specifications.
Resumo:
In this work the effect of Gas Tungsten Arc Welding (GTAW) repairs on the axial fatigue strength of an AISI 4130 steel welded joint used in airframe critical to the flight-safety was investigated. Fatigue tests were performed at room temperature on 0.89 mm thick hot-rolled plates with constant amplitude and load ratio of R = 0.1, at 20 Hz frequency. Monotonic tensile tests, optical metallography and microhardness, residual stress and weld geometric factors measurements were also performed. The fatigue strength decreased with the number of GTAW repairs, and was related to microstructural and microhardness changes, as well as residual stress field and weld profile geometry factors, which gave origin to high stress concentration at the weld toe. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The Brasiliano Cycle in the Seridó Belt (NE Brazil) is regarded mostly as a crustal reworking event, characterized by transcurrent or transpressional shear zones which operated under high temperature and low pressure conditions. In the eastern domain of this belt- the so-called São José de Campestre Massif (SJCM), a transtensional deformation regime is evidenced by extensional components or structures associated to the strikeslip shear zones. The emplacement of the Neoproterozoic Brasiliano granitoids is strongly controled by these discontinuities. Located in the southern border of the SJCM, the Remígio-Pocinhos shear zone (RPSZ) displays, in its northern half, top to the SW extensional movement which progressively grade, towards its southern half, to a dextral strike-slip kinematics, defining a negative semi-flower structure. This shear zone is overprinted upon allocthonous metasediments of the Seridó Group and an older gneiss-migmatite complex, both of which containing metamorphic parageneses from high amphibolite to granulite facies (the latter restricted to the strike-slip zone), defining the peak conditions of deformation. Several granitoid plutons are found along this structure, emplaced coeval with the shearing event. Individually, such bodies do not exceed 30 km2 in outcropping area and are essentially parallel to the trend of the shear zone. Petrographic, textural and geochemical data allow to recognize five different granitoid suites along the RPSZ: porphyritic granites (Serra da Boa Vista and Jandaíra), alkaline granites (Serra do Algodão and Serra do Boqueirão) and medium to coarse-grained granites (Olivedos) as major plutons, while microgranite and aluminous leucogranite sheets occur as minor intrusions. The porphyritic granites are surrounded by metasediments and present sigmoidal or en cornue shapes parallel to the trend of the RPSZ, corroborating the dextral kinematics. Basic to intermediate igneous enclaves are commonly associated to these bodies, frequently displaying mingling textures with the host granitoids. Compositionally these plutons are made up by titanite-biotite monzogranites bearing amphibole and magnetite; they are peraluminous and show affinities to the monzonitic, subalkaline series. Peraluminous, ilmenite-bearing biotite monzogranites and titanite-biotite monzogranites correspond, respectivally, to the Olivedos pluton and the microgranites. The Olivedos body is hosted by metasediments, while the microgranites intrude the gneiss-migmatite complex. Being highly evolved rocks, samples from these granites plot in the crustal melt fields in discrimination diagrams. Nevertheless, their subtle alignment also looks consistent with a monzonitic, subalkaline affinity. These chemical parameters make them closer to the I-type granites. Alkaline, clearly syntectonic granites are also recognized along the RPSZ. The Serra do Algodão and Serra do Boqueirão bodies display elongated shapes parallel to the mylonite belt which runs between the northern, extensional domain and the southern strike-slip zone. The Serra do Algodão pluton shows a characteristic isoclinal fold shape structure. Compositionally they encompass aegirine-augite alkali-feldspar granites and quartz-bearing alkaline syenite bearing garnet (andradite) and magnetite plus ilmenite as opaque phases. These rocks vary from meta to peraluminous, being correlated to the A-type granites. Aluminous leucogranites bearing biotite + muscovite ± sillimanite ± garnet (S-type granites) are frequent but not volumetrically important along the RPSZ. These sheet-like bodies may be folded or boudinaged, representing partial melts extracted from the metasediments during the shear zone development. Whole-rock Rb-Sr isotope studies point to a minimum 55410 Ma age for the crystalization of the porphyritic granites. The alkaline granites and the Olivedos granite produced ca. 530 Ma isochrons which look too young; such values probably represent the closure of the Rb-Sr radiometric clock after crystallization and deformation of the plutons, at least 575 Ma ago (Souza et al. 1998). The porphyritic and the alkaline granites crystallized under high oxygen fugacity conditions, as shown by the presence of both magnetite and hematite in these rocks. The presence of ilmenite in the Olivedos pluton suggests less oxidizing conditions. Amphibole and amphibole-plagioclase thermobarometers point to minimum conditions, around 750°C and 6 Kbars, for the crystallization of the porphyritic granites. The zirconium geothermometer indicates higher temperatures, in the order of 800°C, for the porphyritic granites, and 780°C for the Olivedos pluton. Such values agree with the thermobarometric data optained for the country rocks (5,7 Kbar and 765°C; Souza et al. 1998). The geochemical and isotope data set point to a lower crustal source for the porphyritic and the alkaline granites. Granulite facies quartz diorite to tonalite gneisses, belonging or akin to the gneiss-migmatite complex, probably dominate in the source regions. In the case of the alkaline rocks, subordinate contributions of mantle material may be present either as a mixing magma or as a previously added component to the source region. Tonalite to granodiorite gneisses, with some metasedimentary contribution, may be envisaged for the Olivedos granite. The diversity of granitoid rocks along the RPSZ is explained by its lithospheric dimension, allowing magma extraction at different levels, from the middle to lower crust down to the mantle. The presence of basic to intermediate enclaves, associated to the porphyritic granites, confirm the participation of mantle components in the magma extraction system along the RPSZ. This mega-structure is part of the network of Brasiliano-age shear zones, activated by continental collision and terrane welding processes at the end of the Neoproterozoic
Resumo:
Objectives: This study investigated the effect of microwave disinfection (650 W/6 min) on the flexural strength of five hard chairside reline resins (Kooliner, Duraliner II, Tokuso Rebase Fast, Ufi Get Hard, New Truliner) and one denture base resin (Lucitone 550).Methods: Thirty-two specimens (3.1x10x64 mm) from each acrylic resin were produced and divided into four groups of eight specimens each. The flexural test was performed after polymerization (G1), after two cycles of microwave disinfection (G2), after 7 days storage in water at 37 degrees C (G3) and after seven cycles of microwave disinfection (G4). Specimens from group G4 were microwaved daily being stored in water at 37 degrees C between exposures. The specimens were placed in three-point bend fixture in a MTS machine and loaded until failure. The flexural values (MPa) were submitted to ANOVA and Tukey's test (p=0.05).Results: Two cycles of microwave disinfection promoted a significant increase in flexural strength for materials Kooliner and Lucitone 550. After seven cycles of microwave disinfection, materials Kooliner and New Truliner showed a significant increase (p<0.05) in flexural values. The flexural strength of the material Tokuso Rebase was not significantly affected by microwave irradiation. Seven cycles of microwave disinfection resulted in a significant decrease in the flexural strength of material Duraliner II. Material Ufi Get Hard was the only resin detrimentally affected by microwave disinfection after two and seven cycles.Conclusions: Microwave disinfection did not adversely affect the flexural strength of all tested materials with the exception of material Ufi Get Hard. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: This study investigated the effect of porcelain firing on the misfit of implant-supported frameworks and analyzed the influence of preheat treatment on the dimensional alterations.Materials and Methods: Four external-hex cylindrical implants were placed in polyurethane block. Ten frameworks of screw-retained implant-supported prostheses were cast in Pd-Ag using 2 procedures: (1) control group (CG, n = 5): cast in segments and laser welded; and test group (TG, n = 5): cast in segments, preheated, and laser welded. All samples were subjected to firing to simulate porcelain veneering firing. Strain gauges were bonded around the implants, and microstrain values (mu epsilon = 10(-6)epsilon) were recorded after welding (M1), oxidation cycle (M2), and glaze firing (M3). Data were statistically analyzed (2-way analysis of variance, Bonferroni, alpha = 0.05).Results: The microstrain value in the CG at M3 (475.2 mu epsilon) was significantly different from the values observed at M1 (355.6 mu epsilon) and M2 (413.9 mu epsilon). The values at M2 and M3 in the CG were not statistically different. Microstrain values recorded at different moments (M1: 361.6 mu epsilon/M2: 335.3 mu epsilon/M3: 307.2 mu epsilon) did not show significant difference.Conclusions: The framework misfit deteriorates during firing cycles of porcelain veneering. Metal distortion after porcelain veneering could be controlled by preheat treatment. (Implant Dent 2012;21:225-229)
Resumo:
Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)
Resumo:
Foram realizados estudos para avaliar a microestrutura, a dureza e a resistência à corrosão do titânio comercialmente puro-Ti c.p. soldado por laser e utilizado na confecção de prótese sobre implantes. Verificou-se que na soldagem a laser a microestrutura apresentou três regiões distintas: o cordão de solda, a zona afetada pelo calor - ZAC e o metal base. O Ti c.p. possui microestrutura granular, a microestrutura do cordão de solda é mais refinada e de maior dureza do que o metal base. A ZAC obtida por este processo de soldagem foi relativamente pequena quando comparada com o processo de soldagem por brasagem. Os ensaios eletroquímicos mostraram que a região da solda apresentou menor resistência à corrosão em meio de NaCl 0,15 molL-1 à temperatura ambiente.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The interface formed between the metal and the porcelain of a LASER welded Ni-Cr-Mo alloy was studied. The characterization was carried out through optical microscopy, scanning electron microscopy, X-ray dispersive spectroscopy-EDS and mechanical testing by three-point flexion test-TPE in the region LASER welded with and without the porcelain. The porcelain adhesion with the alloy alone is possible after the oxidation of the metallic surface and subsequent application of an adhesive called opaco. The applied porcelain, on the base metal and fusion zone presented some distinct behaviors. After the TPF test the base metal presented fractures while that in the fusion zone was completely gone. One noticed that the region submitted to the LASER welding showed less porcelain adhesion than the region of the base metal due to the microestructural refinement of the fusion zone. These results can be evidenced by the EDS of the studied regions. The TPF had demonstrated that the Ni-Cr-Mo alloy submitted to the LASER welding, undergone significant alterations in its mechanical properties after the application of the porcelain.
Resumo:
O objetivo deste trabalho foi verificar quanto tempo após a realização da enxertia hipocotiledonar ocorre a soldadura ou adesão entre enxerto e porta-enxerto, e também a formação da ponte de calo, verificada pelo total preenchimento da fenda por tecido meristemático secundário (calo). Foram produzidas 56 mudas de maracujazeiro-amarelo (Passiflora edulis Sims f. flavicarpa Deg.) pela enxertia hipocotiledonar em fenda cheia no topo sobre dois porta-enxertos (P. edulis Sims f. flavicarpa Deg. e P. alata Dryander). Aos 0, 3, 6, 9, 12, 15 e 18 dias após a enxertia, coletou-se a região da enxertia de quatro mudas de cada combinação. O material coletado foi fixado em solução de glutaraldeído a 3%, pós-fixado em tetróxido de ósmio a 2%, desidratado em uma série de álcool etílico (30, 40, 50, 60, 70, 80, 90, 100%), levado ao secador de ponto crítico (CO2), montado, metalizado com ouro - paládio (35 nm) e, por fim, observados e eletromicrografados em microscópio eletrônico de varredura JEOL JSM 5410 (operado em 15 kV). Verificou-se que, aos seis dias após a enxertia, a soldadura para o porta-enxerto Passiflora alata já havia ocorrido, o que só foi constatado para Passiflora edulis f. flavicarpa aos nove dias. Também, aos nove dias, observou-se para ambos os porta-enxertos a completa formação da ponte de calo, indicando que, a partir daí, pode-se iniciar o processo de aclimatação da muda, para levá-la a um ambiente de menor umidade.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Welding in the dentistry has been used for great part of the specialized dentist-surgeons in the implants area to solve prosthesis supported by implant adaptation problems. The development of new equipments Laser and TIG allowed a larger use of these processes in the prosthesis production. In this work, it was studied welded joints made by Laser and TIG, using commercial purity titanium, cpTi, applied in prosthesis supported by implants. The weld characterizations were carried out by light microscopy, EDS_elementary mapping, microhardness and tensile test. Through metallographic characterization, the weld bead presented a martensitic microstructure in the Laser welding process, originated from shear provoked by deformations in the lattice. This caused structural changes of the transformed area, which determines a fine plate-like morphology. In the weld bead from TIG, besides presenting higher hardness, was observed formation of Widmansttaten structure, which is characteristic of a geometric model, resulted of new phase formation along of the crystallographic plans. The martensitic structure is more refined than Widmansttaten structure, due to the high-speed cooling (10(3)degrees C/s) imposed by the Laser process.
Resumo:
The laser Welding process was introduced into dentistry by the end of the 1980s, resulting on a great impulse to that area with the development of cheaper and smaller equipment, using simpler technique. This allowed greater use of that process on the confection of prostheses compared to the brazing process since the heat source for that process is a concentrated light beam of high power, which minimizes distortion problems on the prosthetic pieces. Ag-Pd-Au-Cu alloy used on the confection of dental implant prostheses was observed before and after subjection to the laser welding process. The microstructure was analyzed with the. use of optic microscopy and the corrosion resistance was studied by the traditional electrochemical techniques and by electrochemical impedance, under environmental conditions simulating the aggressiveness found in the mouth cavity. A structural change was detected on the weld area, which presented a refined microstructure deriving from the high-speed cooling. The base metal out of the weld area presented a fusion coarse microstructure. The electrochemical essays showed differences on the potentiodynamic polarization behavior in both weld and metal base areas, indicating superior corrosion resistance in the weld area. The impedance spectra were characterized by capacitive distorted components, presenting linear impedance in the low frequencies area. (C) 2002 Elsevier B.V. B.V. All rights reserved.