992 resultados para Water speed
Resumo:
Nitrate losses from soil profiles by leaching should preferentially be monitored during high rainfall events and during irrigation when fertilizer nitrogen applications are elevated. Using a climatologic water balance, based on the models of Thornthwaite and Penman Monteith for potential evapotranspiration, drainage soil water fluxes below the root zone were estimated in a fertigated coffee crop. Soil solution extraction at the depth of 1 m allowed the calculation of nitrate leaching. The average nitrate concentration in soil solution for plots that received nitrogen by fertigation at a rate of 400 kg ha-1, was 5.42 mg L-1, surpassing the limit of the Brazilian legislation of 10.0 mg L-1, only during one month. For plots receiving 800 kg ha-1 of nitrogen, the average was 25.01 mg L-1, 2.5 times higher than the above-mentioned limit. This information indicates that nitrogen rates higher than 400 kg ha-1 are potentially polluting the ground water. Yearly nitrate amounts of leaching were 24.2 and 153.0 kg ha-1 for the nitrogen rates of 400 and 800 kg ha-1, respectively. The six times higher loss indicates a cost/benefit problem for coffee fertigations above 400 kg ha-1.
Resumo:
During the second half of 1986 the impact of the improvement of water supply and excreta disposal facilities on diarrheal diseases and intestinal parasitosis was studied in 254 children up to six years of age from two favelas (shanty towns) of Belo Horizonte, Brazil. The estimated incidence of diarrhea was 6.2 episodes/child year and the estimated period prevalence reached 31.0 episode days/ child/ year. The point prevalence of parasitosis was 70.7% (Ascaris lumbricoides: 55.4%, Trichuris trichiura: 19.6%, Giardia lamblia: 17.9%). The estimated prevalence of diarrhea decreased with improvement of water supply and sanitation facilities to 45% and 44% respectively, but no statistically significant impact was observed in the case of parasitosis. School education and weaning practice were found to be other important determinants of diarrhea.
Resumo:
Reclaimed water from small wastewater treatment facilities in the rural areas of the Beira Interior region (Portugal) may constitute an alternative water source for aquifer recharge. A 21-month monitoring period in a constructed wetland treatment system has shown that 21,500 m(3) year(-1) of treated wastewater (reclaimed water) could be used for aquifer recharge. A GIS-based multi-criteria analysis was performed, combining ten thematic maps and economic, environmental and technical criteria, in order to produce a suitability map for the location of sites for reclaimed water infiltration. The areas chosen for aquifer recharge with infiltration basins are mainly composed of anthrosol with more than 1 m deep and fine sand texture, which allows an average infiltration velocity of up to 1 m d(-1). These characteristics will provide a final polishing treatment of the reclaimed water after infiltration (soil aquifer treatment (SAT)), suitable for the removal of the residual load (trace organics, nutrients, heavy metals and pathogens). The risk of groundwater contamination is low since the water table in the anthrosol areas ranges from 10 m to 50 m. Oil the other hand, these depths allow a guaranteed unsaturated area suitable for SAT. An area of 13,944 ha was selected for study, but only 1607 ha are suitable for reclaimed water infiltration. Approximately 1280 m(2) were considered enough to set up 4 infiltration basins to work in flooding and drying cycles.
Resumo:
The Gulf of Cadiz coasts are exposed to tsunamis. Emergency planning tools are now taking into account this fact, especially because a series of historical occurrences were strikingly significant, having left strong evidence behind, in the mareographic records, the geological evidence or simply the memory of the populations. The study area is a strip along the Algarve coast, south Portugal, an area known to have been heavily impacted by the 1 November 1755 event. In this study we use two different tsunami scenarios generated by the rupture of two thrust faults identified in the area, corresponding to 8.1-8.3 magnitude earthquakes. Tsunami propagation and inundation computation is performed using a non-linear shallow water code with bottom friction. Numerical modeling results are presented in terms of flow depth and current velocity with maximum values of 7 m and 8 m/s for inundation depth and flow speed, respectively. These results constitute a valuable tool for local authorities, emergency and decision planners to define the priority zones where tsunami mitigation measures must be implemented and to develop tsunami-resilient communities.
Resumo:
OBJECTIVE: To assess the impact of town planning, infrastructure, sanitation and rainfall on the bacteriological quality of domestic water supplies. METHODS: Water samples obtained from deep and shallow wells, boreholes and public taps were cultured to determine the most probable number of Escherichia coli and total coliform using the multiple tube technique. Presence of enteric pathogens was detected using selective and differential media. Samples were collected during both periods of heavy and low rainfall and from municipalities that are unique with respect to infrastructure planning, town planning and sanitation. RESULTS: Contamination of treated and pipe distributed water was related with distance of the collection point from a utility station. Faults in pipelines increased the rate of contamination (p<0.5) and this occurred mostly in densely populated areas with dilapidated infrastructure. Wastewater from drains was the main source of contamination of pipe-borne water. Shallow wells were more contaminated than deep wells and boreholes and contamination was higher during period of heavy rainfall (p<0.05). E. coli and enteric pathogens were isolated from contaminated supplies. CONCLUSIONS: Poor town planning, dilapidated infrastructure and indiscriminate siting of wells and boreholes contributed to the low bacteriological quality of domestic water supplies. Rainfall accentuated the impact.
Resumo:
This paper presents a variable speed autonomous squirrel cage generator excited by a current-controlled voltage source inverter to be used in stand-alone micro-hydro power plants. The paper proposes a system control strategy aiming to properly excite the machine as well as to achieve the load voltage control. A feed-forward control sets the appropriate generator flux by taking into account the actual speed and the desired load voltage. A load voltage control loop is used to adjust the generated active power in order to sustain the load voltage at a reference value. The control system is based on a rotor flux oriented vector control technique which takes into account the machine saturation effect. The proposed control strategy and the adopted system models were validated both by numerical simulation and by experimental results obtained from a laboratory prototype. Results covering the prototype start-up, as well as its steady-state and dynamical behavior are presented. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVE: To evaluate the microbiological quality of treated and untreated water samples came from urban and rural communities and to examine the relationship between coliforms occurrence and average water temperature, and a comparison of the rainfall levels. METHODS: A sample of 3,073 untreated and treated (chlorinated) water from taps (1,594), reservoir used to store treated water (1,033), spring water (96) and private well (350) collected for routine testing between 1996 and 1999 was analyzed by the multiple dilution tube methods used to detect the most probable number of total and fecal coliforms. These samples were obtained in the region of Maringá, state of Paraná, Brazil. RESULTS: The highest numbers water samples contaminated by TC (83%) and FC (48%) were found in the untreated water. TC and FC in samples taken from reservoirs used to store treated water was higher than that from taps midway along distribution lines. Among the treated water samples examined, coliform bacteria were found in 171 of the 1,033 sampling reservoirs. CONCLUSIONS: Insufficient treatment or regrowth is suggested by the observation that more than 17% of these treated potable water contained coliform. TC and FC positive samples appear to be similar and seasonally influenced in treated water. Two different periods must be considered for the occurrence of both TC and FC positive samples: (i) a warm-weather period (September-March) with high percentage of contaminated samples; and (ii) cold-weather period (April-August) were they are lower. Both TC and TF positive samples declined with the decreased of water temperature.
Resumo:
Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The assessment of surface water nanofiltration (NF) for the removal of endocrine disruptors (EDs) Nonylphenol Ethoxylate (IGEPAL), 4-Nonylphenol (NP) and 4-Octylphenol (OP) was carried out with three commercial NF membranes - NF90, NF200, NF270. The permeation experiments were conducted in laboratory flat-cell units of 13.2 x 10(-4) m(2) of surface area and in a DSS Lab-unit M20 with a membrane surface area of 0.036 m2. The membranes hydraulic permeabilities ranged from 3.7 to 15.6 kg/h/m(2)/bar and the rejection coefficients to NaCl, Na2SO4 and Glucose are for NF90: 97%, 99% and 97%, respectively; for NF200: 66%, 98% and 90%, respectively and for NF270: 48%, 94% and 84%, respectively. Three sets of nanofiltration experiments were carried out: i) NF of aqueous model solutions of NP, IGEPAL and OP running in total recirculation mode; ii) NF of surface water from Rio Sado (Settibal, Portugal) running in concentration mode; iii) NF of surface water from Rio Sado inoculated with NP, IGEPAL and OP running in concentration mode. The results of model solutions experiments showed that the EDs rejection coefficients are approximately 100% for all the membranes. The results obtained for the surface water showed that the rejection coefficients to natural organic Matter (NOM) are 94%, 82% and 78% for NF90, NF200 and NF 270 membranes respectively, with and without inoculation of EDs. The rejection coefficients to EDs in surface water with and without inoculation of EDs are 100%, showing that there is a fraction of NOM of high molecular weight that retains the EDs in the concentrate and that there is a fraction of NOM of low molecular weight that permeates through the NF membranes free of EDs.
Resumo:
The solubility of ethene in water and in the fermentation medium of Xanthobacter Py(2) was determined with a Ben-Naim-Baer type apparatus. The solubility measurements were carried out in the temperature range of (293.15 to 323.15) K and at atmospheric pressure with a precision of about +/- 0.3 %. The Ostwald coefficients, the mole fractions of the dissolved ethene, at the gas partial pressure of 101.325 kPa, and the Henry coefficients, at the water vapor pressure, were calculated using accurate thermodynamic relations. A comparison between the solubility of ethene in water and in the cultivation medium has shown that this gas is about 2.4 % more soluble in pure water. On the other hand, from the solubility temperature dependence, the Gibbs energy, enthalpy, and entropy changes for the process of transferring the solute from the gaseous phase to the liquid solutions were also determined. Moreover, the perturbed-chain statistical associating fluid theory equation of state (PC-SAFT EOS) model was used for the prediction of the solubility of ethene in water. New parameters, k(ij), are proposed for this system, and it was found that using a ky temperature-dependent PC-SAFT EOS describes more accurately the behavior solubilities of ethene in water at 101.325 kPa, improving the deviations to 1 %.
Resumo:
As wind power generation undergoes rapid growth, new technical challenges emerge: dynamic stability and power quality. The influence of wind speed disturbances and a pitch control malfunction on the quality of the energy injected into the electric grid is studied for variable-speed wind turbines with different power-electronic converter topologies. Additionally, a new control strategy is proposed for the variable-speed operation of wind turbines with permanent magnet synchronous generators. The performance of disturbance attenuation and system robustness is ascertained. Simulation results are presented and conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Mestrado em Radioterapia.
Resumo:
A method to control the speed or the torque of a permanent-magnet direct current motor is presented. The rotor speed and the external torque estimation are simultaneously provided by appropriate observers. The sensorless control scheme is based on current measurement and switching states of power devices. The observer’s performances are dependent on the accurate machine parameters knowledge. Sliding mode control approach was adopted for drive control, providing the suitable switching states to the chopper power devices. Despite the predictable chattering, a convenient first order switching function was considered enough to define the sliding surface and to correspond with the desired control specifications and drive performance. The experimental implementation was supported on a single dsPIC and the controller includes a logic overcurrent protection.
Resumo:
The top velocity of high-speed trains is generally limited by the ability to supply the proper amount of energy through the pantograph-catenary interface. The deterioration of this interaction can lead to the loss of contact, which interrupts the energy supply and originates arcing between the pantograph and the catenary, or to excessive contact forces that promote wear between the contacting elements. Another important issue is assessing on how the front pantograph influences the dynamic performance of the rear one in trainsets with two pantographs. In this work, the track and environmental conditions influence on the pantograph-catenary is addressed, with particular emphasis in the multiple pantograph operations. These studies are performed for high speed trains running at 300 km/h with relation to the separation between pantographs. Such studies contribute to identify the service conditions and the external factors influencing the contact quality on the overhead system. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
Water-based cellulose cholesteric liquid crystalline phases at rest can undergo structural changes induced by shear flow. This reflects on the deuterium spectra recorded when the system is investigated by rheo-nuclear magnetic resonance (rheo-NMR) techniques. In this work, the model system hydroxypropylcellulose (HPC)+water is revisited using rheo-NMR to clarify unsettled points regarding its behavior under shear and in relaxation. The NMR spectra allow the identification of five different stable ordering states, within shear and relaxation, which are well integrated in a mesoscopic picture of the system's structural evolution under shear and relaxation. This picture emerging from the large body of studies available for this system by other experimental techniques, accounts well for the NMR data and is in good agreement with the three distinct regions of steady shear flow recognized for some lyotropic LC polymers. Shear rates in between 0.1 and 1.0 s(-1) where investigated using a Taylor-Couette flow and deuterated water was used as solvent for the deuterium NMR (DNMR) analysis.