1000 resultados para WEC control
Resumo:
Fuzzy logic controllers (FLC) are intelligent systems, based on heuristic knowledge, that have been largely applied in numerous areas of everyday life. They can be used to describe a linear or nonlinear system and are suitable when a real system is not known or too difficult to find their model. FLC provide a formal methodology for representing, manipulating and implementing a human heuristic knowledge on how to control a system. These controllers can be seen as artificial decision makers that operate in a closed-loop system, in real time. The main aim of this work was to develop a single optimal fuzzy controller, easily adaptable to a wide range of systems – simple to complex, linear to nonlinear – and able to control all these systems. Due to their efficiency in searching and finding optimal solution for high complexity problems, GAs were used to perform the FLC tuning by finding the best parameters to obtain the best responses. The work was performed using the MATLAB/SIMULINK software. This is a very useful tool that provides an easy way to test and analyse the FLC, the PID and the GAs in the same environment. Therefore, it was proposed a Fuzzy PID controller (FL-PID) type namely, the Fuzzy PD+I. For that, the controller was compared with the classical PID controller tuned with, the heuristic Ziegler-Nichols tuning method, the optimal Zhuang-Atherton tuning method and the GA method itself. The IAE, ISE, ITAE and ITSE criteria, used as the GA fitness functions, were applied to compare the controllers performance used in this work. Overall, and for most systems, the FL-PID results tuned with GAs were very satisfactory. Moreover, in some cases the results were substantially better than for the other PID controllers. The best system responses were obtained with the IAE and ITAE criteria used to tune the FL-PID and PID controllers.
Resumo:
Scope of study: welding operations result in harmful emissions of nanoparticles; the aim of emissions monitorisation is to evaluate exposure levels and to derive protection measures in order to protect exposed workers; however, the traditional approach of comparing measured concentrations with exposure limits cannot be used; but risk levels can be quantified by using Control Banding Strategies.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
El desarrollo de equipos ultrasonográficos portátiles ha permitido incorporar esta técnica a los métodos de detección precoz de la Hidatidosis Humana. En esta experiência fueron efectuadas 690 ecografias, hallándose un 5.51% de imágenes compatibles en población general y un 12.24% en grupos de riesgo (convivientes de casos operados). Se observo una disminución significativa de los porcentajes de infección en el hombre en población general en Ias áreas bajo programa de control, utilizándose Ias encuestas ecográficas para esta determinación. Se concluyó sobre la posibilidad de incorporar la ecografía a los sistemas de vigilância epidemiológica de la hidatidosis humana.
Resumo:
The objective of this contribution is to extend the models of cellular/composite material design to nonlinear material behaviour and apply them for design of materials for passive vibration control. As a first step a computational tool allowing determination of optimised one-dimensional isolator behaviour was developed. This model can serve as a representation for idealised macroscopic behaviour. Optimal isolator behaviour to a given set of loads is obtained by generic probabilistic metaalgorithm, simulated annealing. Cost functional involves minimization of maximum response amplitude in a set of predefined time intervals and maximization of total energy absorbed in the first loop. Dependence of the global optimum on several combinations of leading parameters of the simulated annealing procedure, like neighbourhood definition and annealing schedule, is also studied and analyzed. Obtained results facilitate the design of elastomeric cellular materials with improved behaviour in terms of dynamic stiffness for passive vibration control.
Resumo:
This work was undertaken in the municipality of Pedro de Toledo (São Paulo State, Brazil) in 1987, to clarify aspects related to the transmission levels of Schistosoma mansoni in a human population where the snail host is Biomphalaria tenagophila. Since 1980 a control programme has been undertaken in this municipality. Urban and rural populations (4,719 subjects) were submitted to faecal examinations (Kato-Katz method). The overall prevalence rate was 4.8% being higher in males (6.2%) and also in the rural zone (5.8%). The geometric mean of S. mansoni eggs was 35.1 eggs per gramme of faeces (epg). Approximately 80.0% of the carriers presented less than 100 epg and only 20 individuals (9.0%) eliminated more than half of total eggs. The highest index of potencial contamination (IPC) was in the age group of 5 to 20 years (57.6%). Two thirds of the investigated patients (207) were autochthonous of Pedro de Toledo. The geographical distribution of the carriers showed a clear aggregation of the autochthonous cases and a close association between human contact sites and breeding places of B. tenagophila. This study shows that schistosomiasis subjects were not randomly aggregated, the youngsters should be the main target in the prophylaxis, and the efficacy of the control programme.
Resumo:
This paper is on an onshore variable speed wind turbine with doubly fed induction generator and under supervisory control. The control architecture is equipped with an event-based supervisor for the supervision level and fuzzy proportional integral or discrete adaptive linear quadratic as proposed controllers for the execution level. The supervisory control assesses the operational state of the variable speed wind turbine and sends the state to the execution level. Controllers operation are in the full load region to extract energy at full power from the wind while ensuring safety conditions required to inject the energy into the electric grid. A comparison between the simulations of the proposed controllers with the inclusion of the supervisory control on the variable speed wind turbine benchmark model is presented to assess advantages of these controls. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Resumo:
In this paper we exploit the nonlinear property of the SiC multilayer devices to design an optical processor for error detection that enables reliable delivery of spectral data of four-wave mixing over unreliable communication channels. The SiC optical processor is realized by using double pin/pin a-SiC:H photodetector with front and back biased optical gating elements. Visible pulsed signals are transmitted together at different bit sequences. The combined optical signal is analyzed. Data show that the background acts as selector that picks one or more states by splitting portions of the input multi optical signals across the front and back photodiodes. Boolean operations such as EXOR and three bit addition are demonstrated optically, showing that when one or all of the inputs are present, the system will behave as an XOR gate representing the SUM. When two or three inputs are on, the system acts as AND gate indicating the present of the CARRY bit. Additional parity logic operations are performed using four incoming pulsed communication channels that are transmitted and checked for errors together. As a simple example of this approach, we describe an all-optical processor for error detection and then provide an experimental demonstration of this idea. (C) 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
The SiC optical processor for error detection and correction is realized by using double pin/pin a-SiC:H photodetector with front and back biased optical gating elements. Data shows that the background act as selector that pick one or more states by splitting portions of the input multi optical signals across the front and back photodiodes. Boolean operations such as exclusive OR (EXOR) and three bit addition are demonstrated optically with a combination of such switching devices, showing that when one or all of the inputs are present the output will be amplified, the system will behave as an XOR gate representing the SUM. When two or three inputs are on, the system acts as AND gate indicating the present of the CARRY bit. Additional parity logic operations are performed by use of the four incoming pulsed communication channels that are transmitted and checked for errors together. As a simple example of this approach, we describe an all optical processor for error detection and correction and then, provide an experimental demonstration of this fault tolerant reversible system, in emerging nanotechnology.
Resumo:
This paper describes the implementation of a distributed model predictive approach for automatic generation control. Performance results are discussed by comparing classical techniques (based on integral control) with model predictive control solutions (centralized and distributed) for different operational scenarios with two interconnected networks. These scenarios include variable load levels (ranging from a small to a large unbalance generated power to power consumption ratio) and simultaneously variable distance between the interconnected networks systems. For the two networks the paper also examines the impact of load variation in an island context (a network isolated from each other).
Resumo:
This paper describes the use of a Control Banding Tool to assess and further control of exposure of nanoparticles emitted during welding operations. The tool was applied to Metal Active Gas (MAG) arc welding of mild and stainless steel, providing semi-quantitative data on the process, so that protection measures could be derived, e.g. exhaust gas ventilation by hoods, local ventilation devices and containment measures. This tool is quite useful to compare and evaluate the characteristics of arc welding procedures so that more eco-friendly processes could be preferred over the more potentially noxious ones.
Resumo:
This work describes the utilization of Pulsed Electric Fields to control the protozoan contamination of a microalgae culture, in an industrial 2.7m3 microalgae photobioreactor. The contaminated culture was treated with Pulsed Electric Fields, PEF, for 6h with an average of 900V/cm, 65μs pulses of 50Hz. Working with recirculation, all the culture was uniformly exposed to the PEF throughout the assay. The development of the microalgae and protozoan populations was followed and the results showed that PEF is effective on the selective elimination of protozoa from microalgae cultures, inflicting on the protozoa growth halt, death or cell rupture, without affecting microalgae productivity. Specifically, the results show a reduction of the active protozoan population of 87% after 6h treatment and 100% after few days of normal cultivation regime. At the same time, microalgae growth rate remained unaffected. © 2014 Elsevier B.V.
Resumo:
Applications of niclosamide at three-monthly intervals were undertaken for 14 years in foci of Biomphalaria glabrata in the water sources of Peri-Peri (Capim Branco, MG). All the residents of the area were submitted to an annual fecal examination (Kato/Katz) and those individuals eliminating Schistosoma mansoni eggs were treated with oxamniquine. A malacological survey was undertaken at three-monthly intervals by means of ten scoops with a perforated ladle each ten metres along the two banks of the ditches and streams of the region. Where snails were found, molluscicide was applied by means of dripping or aspersion using a 3 ppm aqueous suspension of niclosamide. Initially, a mean of 14.3% of snails in the region were found to be eliminating cercariae. Following the first four applications of molluscicide, this was reduced to 0.0% and maintained at about 1.5% throughout the program. Thus, there was a continued possibility of schistosomiasis transmission in the area and it was observed that the population of snails reestablished itself within three months of molluscicide application. The results obtained in this study do not encourage the continual use of niclosamide as the only method of control of schistosomiasis.
Resumo:
A schistosomiasis control program was implemented between 1974/87 in Peri-Peri,. MG (622 inhabitants). Molluscicide (niclosamide) was applied at three monthly intervals in water sources with Biomphalaria glabrata, and individuals eliminating Schistosoma mansoni eggs in the feces were treated annually with oxamniquine. From 1974 to 1983 the control measures were undertaken by staff of the "René Rachou" Research Center FIOCRUZ (CPqRR), and from 1984 to 1987 these measures were included in the Capim Branco basic health network activities. During both periods, the prevalence, incidence, intensity of infection and hepatosplenic form as well as the number of infected snails decreased significantly. The prevalence decreased from 43.5 to 4.4%, the incidence from 19.0 to 2.9%, the overall intensity of S. mansoni from 281 to 87 and of the hepatosplenic form from 5.9 to 0.0%. The results obtained suggest that the municipal management of control measures was as effective as the vertical program conducted by CPqRR staff.