995 resultados para Ventilation data
Resumo:
Electric power networks, namely distribution networks, have been suffering several changes during the last years due to changes in the power systems operation, towards the implementation of smart grids. Several approaches to the operation of the resources have been introduced, as the case of demand response, making use of the new capabilities of the smart grids. In the initial levels of the smart grids implementation reduced amounts of data are generated, namely consumption data. The methodology proposed in the present paper makes use of demand response consumers’ performance evaluation methods to determine the expected consumption for a given consumer. Then, potential commercial losses are identified using monthly historic consumption data. Real consumption data is used in the case study to demonstrate the application of the proposed method.
Resumo:
RESUMO - A exposição a formaldeído é reconhecidamente um dos mais importantes factores de risco presente nos laboratórios hospitalares de anatomia patológica. Neste contexto ocupacional, o formaldeído é utilizado em solução, designada comummente por formol. Trata-se de uma solução comercial de formaldeído, normalmente diluída a 10%, sendo pouco onerosa e, por esse motivo, a eleita para os trabalhos de rotina em anatomia patológica. A solução é utilizada como fixador e conservante do material biológico, pelo que as peças anatómicas a serem processadas são previamente impregnadas. No que concerne aos efeitos para a saúde do formaldeído, os efeitos locais parecem apresentar um papel mais importante comparativamente com os efeitos sistémicos, devido à sua reactividade e rápido metabolismo nas células da pele, tracto gastrointestinal e pulmões. Da mesma forma, a localização das lesões correspondem principalmente às zonas expostas às doses mais elevadas deste agente químico, ou seja, o desenvolvimento dos efeitos tóxicos dependerá mais da intensidade da dose externa do que da duração da exposição. O efeito do formaldeído no organismo humano mais facilmente detectável é a acção irritante, transitória e reversível sobre as mucosas dos olhos e aparelho respiratório superior (naso e orofaringe), o que acontece em geral para exposições frequentes e superiores a 1 ppm. Doses elevadas são citotóxicas e podem conduzir a degenerescência e necrose das mucosas e epitélios. No que concerne aos efeitos cancerígenos, a primeira avaliação efectuada pela International Agency for Research on Cancer data de 1981, actualizada em 1982, 1987, 1995 e 2004, considerando-o como um agente cancerígeno do grupo 2A (provavelmente carcinogénico). No entanto, a mais recente avaliação, em 2006, considera o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a este agente é susceptível de causar cancro nasofaríngeo em humanos. Constituiu objectivo principal deste estudo caracterizar a exposição profissional a formaldeído nos laboratórios hospitalares de anatomia patológica Portugueses. Pretendeu-se, ainda, descrever os fenómenos ambientais da contaminação ambiental por formaldeído e explorar eventuais associações entre variáveis. Considerou-se uma amostra de 10 laboratórios hospitalares de anatomia patológica, avaliada a exposição dos três grupos profissionais por comparação com os dois referenciais de exposição e, ainda, conhecidos os valores de concentração máxima em 83 actividades. Foram aplicados simultaneamente dois métodos distintos de avaliação ambiental: um dos métodos (Método 1) fez uso de um equipamento de leitura directa com o princípio de medição por Photo Ionization Detection, com uma lâmpada de 11,7 eV e, simultaneamente, realizou-se o registo da actividade. Este método disponibilizou dados para o referencial de exposição da concentração máxima; o outro método (Método 2) traduziu-se na aplicação do método NIOSH 2541, implicando o uso de bombas de amostragem eléctricas de baixo caudal e posterior processamento analítico das amostras por cromatografia gasosa. Este método, por sua vez, facultou dados para o referencial de exposição da concentração média ponderada. As estratégias de medição de cada um dos métodos e a definição dos grupos de exposição existentes neste contexto ocupacional, designadamente os Técnicos de Anatomia Patológica, os Médicos Anatomo-Patologistas e os Auxiliares, foram possíveis através da informação disponibilizada pelas técnicas de observação da actividade da análise (ergonómica) do trabalho. Estudaram-se diversas variáveis independentes, nomeadamente a temperatura ambiente e a humidade relativa, a solução de formaldeído utilizada, as condições de ventilação existentes e o número médio de peças processadas por dia em cada laboratório. Para a recolha de informação sobre estas variáveis foi preenchida, durante a permanência nos laboratórios estudados, uma Grelha de Observação e Registo. Como variáveis dependentes seleccionaram-se três indicadores de contaminação ambiental, designadamente o valor médio das concentrações superiores a 0,3 ppm em cada laboratório, a Concentração Média Ponderada obtida para cada grupo de exposição e o Índice do Tempo de Regeneração de cada laboratório. Os indicadores foram calculados e definidos através dos dados obtidos pelos dois métodos de avaliação ambiental aplicados. Baseada no delineado pela Universidade de Queensland, foi ainda aplicada uma metodologia de avaliação do risco de cancro nasofaríngeo nas 83 actividades estudadas de modo a definir níveis semi-quantitativos de estimação do risco. Para o nível de Gravidade considerou-se a informação disponível em literatura científica que define eventos biológicos adversos, relacionados com o modo de acção do agente químico e os associa com concentrações ambientais de formaldeído. Para o nível da Probabilidade utilizou-se a informação disponibilizada pela análise (ergonómica) de trabalho que permitiu conhecer a frequência de realização de cada uma das actividades estudadas. A aplicação simultânea dos dois métodos de avaliação ambiental resultou na obtenção de resultados distintos, mas não contraditórios, no que concerne à avaliação da exposição profissional a formaldeído. Para as actividades estudadas (n=83) verificou-se que cerca de 93% dos valores são superiores ao valor limite de exposição definido para a concentração máxima (VLE-CM=0,3 ppm). O “exame macroscópico” foi a actividade mais estudada e onde se verificou a maior prevalência de resultados superiores ao valor limite (92,8%). O valor médio mais elevado da concentração máxima (2,04 ppm) verificou-se no grupo de exposição dos Técnicos de Anatomia Patológica. No entanto, a maior amplitude de resultados observou-se no grupo dos Médicos Anatomo-Patologistas (0,21 ppm a 5,02 ppm). No que respeita ao referencial da Concentração Média Ponderada, todos os valores obtidos nos 10 laboratórios estudados para os três grupos de exposição foram inferiores ao valor limite de exposição definido pela Occupational Safety and Health Administration (TLV-TWA=0,75 ppm). Verificou-se associação estatisticamente significativa entre o número médio de peças processadas por laboratório e dois dos três indicadores de contaminação ambiental utilizados, designadamente o valor médio das concentrações superiores a 0,3 ppm (p=0,009) e o Índice do Tempo de Regeneração (p=0,001). Relativamente à temperatura ambiente não se observou associação estatisticamente significativa com nenhum dos indicadores de contaminação ambiental utilizados. A humidade relativa apresentou uma associação estatisticamente significativa apenas com o indicador de contaminação ambiental da Concentração Média Ponderada de dois grupos de exposição, nomeadamente com os Médicos Anatomo-Patologistas (p=0,02) e os Técnicos de Anatomia Patológica (p=0,04). A aplicação da metodologia de avaliação do risco nas 83 actividades estudadas permitiu verificar que, em cerca de dois terços (35%), o risco foi classificado como (pelo menos) elevado e, ainda, constatar que 70% dos laboratórios apresentou pelo menos 1 actividade com a classificação de risco elevado. Da aplicação dos dois métodos de avaliação ambiental e das informações obtidas para os dois referenciais de exposição pode concluir-se que o referencial mais adequado é a Concentração Máxima por estar associado ao modo de actuação do agente químico. Acresce, ainda, que um método de avaliação ambiental, como o Método 1, que permite o estudo das concentrações de formaldeído e simultaneamente a realização do registo da actividade, disponibiliza informações pertinentes para a intervenção preventiva da exposição por permitir identificar as actividades com a exposição mais elevada, bem como as variáveis que a condicionam. As peças anatómicas apresentaram-se como a principal fonte de contaminação ambiental por formaldeído neste contexto ocupacional. Aspecto de particular interesse, na medida que a actividade desenvolvida neste contexto ocupacional e, em particular na sala de entradas, é centrada no processamento das peças anatómicas. Dado não se perspectivar a curto prazo a eliminação do formaldeído, devido ao grande número de actividades que envolvem ainda a utilização da sua solução comercial (formol), pode concluir-se que a exposição a este agente neste contexto ocupacional específico é preocupante, carecendo de uma intervenção rápida com o objectivo de minimizar a exposição e prevenir os potenciais efeitos para a saúde dos trabalhadores expostos. ---------------- ABSTRACT - Exposure to formaldehyde is recognized as one of the most important risk factors present in anatomy and pathology laboratories from hospital settings. In this occupational setting, formaldehyde is used in solution, typically diluted to 10%, and is an inexpensive product. Because of that, is used in routine work in anatomy and pathology laboratories. The solution is applied as a fixative and preservative of biological material. Regarding formaldehyde health effects, local effects appear to have a more important role compared with systemic effects, due to his reactivity and rapid metabolism in skin, gastrointestinal tract and lungs cells. Likewise, lesions location correspond mainly to areas exposed to higher doses and toxic effects development depend more on external dose intensity than exposure duration. Human body formaldehyde effect more easily detectable is the irritating action, transient and reversible on eyes and upper respiratory tract (nasal and throat) membranes, which happen in general for frequent exposure to concentrations higher than 1 ppm. High doses are cytotoxic and can lead to degeneration, and also to mucous membranes and epithelia necrosis. With regard to carcinogenic effects, first assessment performed by International Agency for Research on Cancer in 1981, updated in 1982, 1987, 1995 and 2004, classified formaldehyde in Group 2A (probably carcinogenic). However, most recent evaluation in 2006, classifies formaldehyde carcinogenic (Group 1), based on evidence that exposure to this agent is likely to cause nasopharyngeal cancer in humans. This study principal objective was to characterize occupational exposure to formaldehyde in anatomy and pathology hospital laboratories, as well to describe formaldehyde environmental contamination phenomena and explore possible associations between variables. It was considered a sample of 10 hospital pathology laboratories, assessed exposure of three professional groups for comparison with two exposure metrics, and also knows ceiling concentrations in 83 activities. Were applied, simultaneously, two different environmental assessment methods: one method (Method 1) using direct reading equipment that perform measure by Photo Ionization Detection, with 11,7 eV lamps and, simultaneously, make activity description and film. This method provided data for ceiling concentrations for each activity study (TLV-C). In the other applied method (Method 2), air sampling and formaldehyde analysis were performed according to NIOSH method (2541). This method provided data average exposure concentration (TLV-TWA). Measuring and sampling strategies of each methods and exposure groups definition (Technicians, Pathologists and Assistants) was possible by information provided by activities (ergonomic) analysis. Several independent variables were studied, including temperature and relative humidity, formaldehyde solution used, ventilation conditions, and also anatomic pieces mean value processed per day in each laboratory. To register information about these variables was completed an Observation and Registration Grid. Three environmental contamination indicators were selected has dependent variables namely: mean value from concentrations exceeding 0,3 ppm in each laboratory, weighted average concentration obtained for each exposure group, as well each laboratory Time Regeneration Index. These indicators were calculated and determined through data obtained by the two environmental assessment methods. Based on Queensland University proposal, was also applied a methodology for assessing nasopharyngeal cancer risk in 83 activities studied in order to obtain risk levels (semi-quantitative estimation). For Severity level was considered available information in scientific literature that defines biological adverse events related to the chemical agent action mode, and associated with environment formaldehyde concentrations. For Probability level was used information provided by (ergonomic) work analysis that helped identifies activity frequency. Environmental assessment methods provide different results, but not contradictory, regarding formaldehyde occupational exposure evaluation. In the studied activities (n=83), about 93% of the values were above exposure limit value set for ceiling concentration in Portugal (VLE-CM = 0,3 ppm). "Macroscopic exam" was the most studied activity, and obtained the higher prevalence of results superior than 0,3 ppm (92,8%). The highest ceiling concentration mean value (2,04 ppm) was obtain in Technicians exposure group, but a result wider range was observed in Pathologists group (0,21 ppm to 5,02 ppm). Concerning Method 2, results from the three exposure groups, were all lower than limit value set by Occupational Safety and Health Administration (TLV-TWA=0,75ppm). There was a statistically significant association between anatomic pieces mean value processed by each laboratory per day, and two of the three environmental contamination indicators used, namely average concentrations exceeding 0,3 ppm (p=0,009) and Time Regeneration Index (p=0,001). Temperature was not statistically associated with any environmental contamination used indicators. Relative humidity had a statistically significant association only with one environmental contamination indicator, namely weighted average concentration, particularly with Pathologists group (p=0,02) and Technicians group (p=0,04). Risk assessment performed in the 83 studied activities showed that around two thirds (35%) were classified as (at least) high, and also noted that 70% of laboratories had at least 1 activity with high risk rating. The two environmental assessment methods application, as well information obtained from two exposure metrics, allowed to conclude that most appropriate exposure metric is ceiling concentration, because is associated with formaldehyde action mode. Moreover, an environmental method, like Method 1, which allows study formaldehyde concentrations and relates them with activity, provides relevant information for preventive information, since identifies the activity with higher exposure, as well variables that promote exposure. Anatomic pieces represent formaldehyde contamination main source in this occupational setting, and this is of particular interest because all activities are focused on anatomic pieces processing. Since there is no prospect, in short term, for formaldehyde use elimination due to large number of activities that still involve solution use, it can be concluded that exposure to this agent, in this particular occupational setting, is preoccupant, requiring an rapid intervention in order to minimize exposure and prevent potential health effects in exposed workers.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Worldwide electricity markets have been evolving into regional and even continental scales. The aim at an efficient use of renewable based generation in places where it exceeds the local needs is one of the main reasons. A reference case of this evolution is the European Electricity Market, where countries are connected, and several regional markets were created, each one grouping several countries, and supporting transactions of huge amounts of electrical energy. The continuous transformations electricity markets have been experiencing over the years create the need to use simulation platforms to support operators, regulators, and involved players for understanding and dealing with this complex environment. This paper focuses on demonstrating the advantage that real electricity markets data has for the creation of realistic simulation scenarios, which allow the study of the impacts and implications that electricity markets transformations will bring to the participant countries. A case study using MASCEM (Multi-Agent System for Competitive Electricity Markets) is presented, with a scenario based on real data, simulating the European Electricity Market environment, and comparing its performance when using several different market mechanisms.
Resumo:
This paper presents the Realistic Scenarios Generator (RealScen), a tool that processes data from real electricity markets to generate realistic scenarios that enable the modeling of electricity market players’ characteristics and strategic behavior. The proposed tool provides significant advantages to the decision making process in an electricity market environment, especially when coupled with a multi-agent electricity markets simulator. The generation of realistic scenarios is performed using mechanisms for intelligent data analysis, which are based on artificial intelligence and data mining algorithms. These techniques allow the study of realistic scenarios, adapted to the existing markets, and improve the representation of market entities as software agents, enabling a detailed modeling of their profiles and strategies. This work contributes significantly to the understanding of the interactions between the entities acting in electricity markets by increasing the capability and realism of market simulations.
Resumo:
Dissertation presented to obtain the Ph.D degree in Bioinformatics
Resumo:
Thesis submitted to Faculdade de Ciências e Tecnologia of the Universidade Nova de Lisboa, in partial fulfilment of the requirements for the degree of Master in Computer Science
Resumo:
Harnessing idle PCs CPU cycles, storage space and other resources of networked computers to collaborative are mainly fixated on for all major grid computing research projects. Most of the university computers labs are occupied with the high puissant desktop PC nowadays. It is plausible to notice that most of the time machines are lying idle or wasting their computing power without utilizing in felicitous ways. However, for intricate quandaries and for analyzing astronomically immense amounts of data, sizably voluminous computational resources are required. For such quandaries, one may run the analysis algorithms in very puissant and expensive computers, which reduces the number of users that can afford such data analysis tasks. Instead of utilizing single expensive machines, distributed computing systems, offers the possibility of utilizing a set of much less expensive machines to do the same task. BOINC and Condor projects have been prosperously utilized for solving authentic scientific research works around the world at a low cost. In this work the main goal is to explore both distributed computing to implement, Condor and BOINC, and utilize their potency to harness the ideal PCs resources for the academic researchers to utilize in their research work. In this thesis, Data mining tasks have been performed in implementation of several machine learning algorithms on the distributed computing environment.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
Dado o panorama de conservação de energia a nível nacional e mundial, torna-se hoje em dia muito importante, que seja possível controlar e estimar o consumo energético nos edifícios. Assim, atendendo à actual problemática energética e ao crescente consumo energético nos edifícios, é importante parametrizar, avaliar e comparar este consumo. Neste sentido, nas últimas décadas, têm sido efectuados desenvolvimentos técnicos, quer ao nível do equipamento de campo para efectuar monitorização e medição, quer ao nível da simulação dinâmica de edifícios. Com esta dissertação de mestrado, pretendeu-se efectuar a simulação dinâmica de um edifício escolar existente a funcionar em pleno, e efectuar uma análise de sensibilidade relativamente ao grau de variação dos resultados obtidos através da aplicação de dois programas de cálculo térmico e energético. Foram utilizados, o programa VE-Pro da IES (Integrated Environmental Solutions) e o programa Trace 700 da TRANE. Ambos os programas foram parametrizados com os mesmos dados de entrada, tendo em atenção as opções de simulação disponibilizadas por ambos. Posteriormente, utilizaram-se os dados retirados da simulação para calcular a classificação energética no âmbito do sistema de certificação energética (SCE), através de uma folha de cálculo desenvolvida para o efeito. Foram ainda consideradas várias soluções de eficiência energética para o edifício, com vista a poupanças reais de energia, tendo sempre atenção ao conforto térmico dos ocupantes. Dessas medidas fazem parte, medidas relacionadas com a iluminação, como a substituição da iluminação existente por luminárias do tipo LED (Light Emitting Diode), soluções de energias renováveis, como a instalação de colectores solares para aquecimento das águas quentes sanitárias, e painéis fotovoltaicos para produção de energia, bem como medidas ligadas aos equipamentos de climatização. Posteriormente, recalculou-se a classificação energética afectada das melhorias. Os resultados obtidos nas duas simulações foram analisados sob o ponto de vista do aquecimento, arrefecimento, ventilação, iluminação e equipamentos eléctricos. A comparação das duas simulações para cada parâmetro acima referido, apresentaram variações inferiores a 5%. O desvio maior verificou-se na ventilação, com o valor de aproximadamente 4,9%. Transpondo estes resultados para o cálculo do IEE (Índice de Eficiência Energética), verificou-se um desvio inferior a 2%.
Resumo:
O presente trabalho enquadra-se na temática de segurança contra incêndio em edifícios e consiste num estudo de caso de projeto de deteção e extinção de incêndio num Data Center. Os objetivos deste trabalho resumem-se à realização de um estudo sobre o estado da arte da extinção e deteção automática de incêndio, ao desenvolvimento de uma ferramenta de software de apoio a projetos de extinção por agentes gasosos, como também à realização de um estudo e uma análise da proteção contra incêndios em Data Centers. Por último foi efetuado um estudo de caso. São abordados os conceitos de fogo e de incêndio, em que um estudo teórico à temática foi desenvolvido, descrevendo de que forma pode o fogo ser originado e respetivas consequências. Os regulamentos nacionais relativos à Segurança Contra Incêndios em Edifícios (SCIE) são igualmente abordados, com especial foco nos Sistemas Automáticos de Deteção de Incêndio (SADI) e nos Sistemas Automáticos de Extinção de Incêndio (SAEI), as normas nacionais e internacionais relativas a esta temática também são mencionadas. Pelo facto de serem muito relevantes para o desenvolvimento deste trabalho, os sistemas de deteção de incêndio são exaustivamente abordados, mencionando características de equipamentos de deteção, técnicas mais utilizadas como também quais os aspetos a ter em consideração no dimensionamento de um SADI. Quanto aos meios de extinção de incêndio foram mencionados quais os mais utilizados atualmente, as suas vantagens e a que tipo de fogo se aplicam, com especial destaque para os SAEI com utilização de gases inertes, em que foi descrito como deve ser dimensionado um sistema deste tipo. Foi também efetuada a caracterização dos Data Centers para que seja possível entender quais as suas funcionalidades, a importância da sua existência e os aspetos gerais de uma proteção contra incêndio nestas instalações. Por último, um estudo de caso foi desenvolvido, um SADI foi projetado juntamente com um SAEI que utiliza azoto como gás de extinção. As escolhas e os sistemas escolhidos foram devidamente justificados, tendo em conta os regulamentos e normas em vigor.
Resumo:
São muitas as organizações que por todo o mundo possuem instalações deste tipo, em Portugal temos o exemplo da Portugal Telecom que recentemente inaugurou o seu Data Center na Covilhã. O desenvolvimento de um Data Center exige assim um projeto muito cuidado, o qual entre outros aspetos deverá garantir a segurança da informação e das próprias instalações, nomeadamente no que se refere à segurança contra incêndio.
Resumo:
A manutenção, durante vários anos, traduziu-se num conceito paliativo de instalações e equipamentos, o que se veio a revelar como uma atitude negligente perante o Homem e o Ambiente. As preocupações ambientais estão na ordem do dia e têm sido muitas as vozes que se têm levantado para que o consumo de energia seja mais equilibrado e para que as emissões de CO2 diminuam de forma a preservar o Planeta. De acordo com a resolução do Conselho Europeu, em 2007 (1), foi apresentado um pacote de propostas que visam a sustentabilidade e estimulam a Eficiência Energética (EE), com o objectivo de reduzir os consumos energéticos dos edifícios, quer estes sejam novos ou reabilitados. Segundo a Direcção Geral de Energia e Geologia os edifícios são responsáveis por 60% dos consumos de energia eléctrica, consumo esse que pode ser reduzido em mais de 50%, através de medidas de EE, traduzindo-se numa redução de 400 milhões de toneladas de CO2 por ano. (2) Para além de medidas de EE, também as práticas de manutenção preventiva podem contribuir para a diminuição dos consumos energéticos e de emissões de CO2. Segundo o Institute for Building Efficiency práticas de manutenção preventiva em equipamentos de Aquecimento Ventilação e Ar Condicionado (AVAC) reduzem os consumos energéticos de 10 a 20% e, em contrapartida, a negligência na execução da manutenção pode aumentar os consumos energéticos de 30 a 60%. (3) Uma outra análise de valores a ter em conta, é a Intensidade Energética (IE). Leia-se IE como sendo o valor global da energia consumida num país a dividir pelo seu produto interno bruto. A contribuição do sector dos serviços para a IE nacional era de 17% no ano de 2005. (4) Se a estes dados acrescentarmos que 70% dessa energia é consumida por equipamentos AVAC (5) e que práticas de manutenção reduzem esses valores entre 10 a 20%, pode concluir-se que a redução de custos energéticos associada à manutenção preventiva é efectiva e significativa. Apresentando um cenário ideal e hipotético, se ao contributo do sector dos serviços, para a IE nacional, se isolar o valor referente a equipamentos de AVAC, obtem-se uma IE de aproximadamente 12%. Se adicionalmente se considerar uma taxa de redução, relativa à execução da manutenção, entre 10 e 20%, Portugal obteria uma IE, relativamente aos consumos energéticos em edificios de serviços, não de 17% mas sim entre 14,6% e 15,8%. Neste trabalho pretende-se comprovar que um plano de actividades de manutenção equilibrado, monitorizado, e gerido de forma eficaz e funcional, é uma ferramenta fundamental no cumprimento de objectivos e metas europeias traçadas, que se reúnem num objectivo comum de preservação do planeta. A adopção deste tipo de medidas contribuirá para a racionalização dos consumos energéticos e para o aumento da vida útil dos equipamentos, bem como para a melhoria do desempenho económico e financeiro das organizações, tal como se poderá ler mais à frente neste trabalho. Será também analisado um caso prático, verificando a eficácia das medidas tomadas durante as intervenções preventivas de manutenção, sendo que para isso será estudado o comportamento de um equipamento, antes e após a realização de tarefas de manutenção preventiva. Tentar-se-á, junto de gestores de edifícios, recolher a opinião que têm sobre a importância da manutenção. Ao longo de toda a pesquisa foi possível consolidar a hipótese formulada inicialmente no que concerne ao contributo da manutenção para a sustentabilidade, quer através da revisão da literatura, quer nos testes efectuados a equipamentos. Foi possível confirmar que um plano de manutenção ajustado, monitorizado e cumprido é uma ferramenta na diminuição dos consumos energéticos, aumento da vida útil de equipamentos e por sua vez na diminuição de emissões de CO2. Verificou-se também que o controlo de poluentes e ventilação adequada dos edifícios são uma ferramenta essencial para a qualidade do ar interior, parâmetros facilmente controlados nas actividades de manutenção. O contributo das opiniões recolhidas entre os gestores de edifícios, para este estudo, foi também bastante importante, uma vez que todos eles reconhecem o papel importante da manutenção, mas nem todos estão sensibilizados para o seu papel na sustentabilidade do planeta. Nesta dissertação é deixado um alerta: o crescimento da população mundial e a consequente utilização de recursos naturais que são finitos, não sendo controlado de uma forma sustentada, pode resultar na destruição de um planeta único. O papel negativo do Homem nas alterações climáticas é inequívoco e é necessário melhorar a sua relação com o Ambiente. Cada ser humano está inserido na sua comunidade e dentro dela tem a sua função, cabe a cada um exercer esta responsabilidade nas suas actividades do dia-a-dia.
Resumo:
As alterações climáticas são atualmente reconhecidas como uma das mais relevantes ameaças ambientais, sociais e económicas. A resposta a este problema tem-se traduzido na aplicação de um conjunto de legislação e práticas, com o objetivo de promover uma redução significativa das emissões de gases com efeito de estufa. Entre outros, os gases fluorados são dos mais relevantes gases com efeito de estufa, conforme identificados no Protocolo de Quioto. No enquadramento legal em vigor a certificação de técnicos e empresas, assim como certificação de ferramentas para o manuseamento de gases fluorados, sofreu, desde 2011, uma profunda alteração, com impacto nos procedimentos de manutenção existentes até essa data, na atividade de empresas prestadoras de serviços de manutenção e na atuação dos proprietários de edifícios civis e industriais com equipamentos que contêm gases fluorados. Esta tese tem como objetivo evidenciar as ações que as empresas prestadores de serviços necessitam executar para a sua certificação, assim como informar os proprietários de edifícios civis ou industriais, sobre as diferentes vertentes que têm à sua disposição, em termos de gestão da manutenção, de forma a garantir o cumprimento da legislação em vigor nas suas instalações e a gestão de ativos físicos que contêm gases fluorados, tais como equipamentos e instalações de aquecimento, ventilação, ar condicionado e refrigeração. Foi efetuada uma pesquisa aprofundada sobre os requisitos legais e técnicos necessários para a cerificação das empresas que atuam neste sector. Um caso de estudo foi realizado e os resultados apresentados sobre todo o processo de certificação de uma empresa do setor do ar condicionado e refrigeração, para poder prestar serviços em equipamentos ou sistemas que contenham gases fluorados com efeito de estufa.