895 resultados para Urinary retention


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ferroelectric Bi3.25La0.75Ti3O12 (BLT) thin films were deposited on Pt/Ti/SiO2/Si substrates by the polymeric precursor method. The films present c-axis preferred orientation after annealing at 700 degrees C for 2 h in conventional furnace. All the capacitors showed good polarization fatigue characteristics at least up to 1x10(10) bipolar pulse cycles and excellent retention properties up to 1x10(4) s. We found that the polarization loss is insignificant with five write/read voltages at a waiting time of 10 000 S. Independently of the applied electric field the retained switchable polarization approached a nearly steady-state value after a retention time of 10 s. (C) 2005 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two hundred twenty-nine first permanent molar occlusal surfaces were treated with sealants, from a group of sixty-one children. When the three sealants were analyzed at the end of the six-, twelve-, eighteen-, and twenty-four-month periods, it was observed that retentive loss was gradual. Both Concise and Delton showed superior retention when compared with Sealite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of urinary stress incontinence (USI) by intravaginal electrical stimulation (IES) and pelvic floor physiotherapy represents an alternative to other therapies. The purpose of this work was to evaluate the effectiveness of this treatment inpatients with urinary incontinence. From January 1998 to May 2000, 30 women (mean age 54 years) were studied. All patients had USI and 70% urge incontinence; average follow-up was 7 months. Selection criteria were based on clinical history, objective evaluation of perineal musculature by perineometry, and urodynamics. The treatment protocol consisted of three sessions of IES per week for 14 weeks using INNOVA equipment. Physiotherapy was initiated in the fifth week of IES. A significant decrease in the number of micturitions and urgency was observed after treatment (P<0.01). The pad test showed a reduction in urinary leakage from 13.9 to 5.9 g after treatment (P<0.01). Objective evaluation of perineal muscle strength showed a significant improvement in all patients after treatment (P<0.01). A positive correlation was observed between maximum flow rate (Q(max)) and all three variables: urethral pressure profile at rest and on straining (stop test), and abdominal leak-point pressure (ALPP). A positive correlation was also observed between ALPP and the stop test. Over 100 different surgical and conservative treatments have been tried to manage USI. The majority of these procedures reveal that despite progress already made in this area, there is no ideal treatment. Satisfactory results can be achieved with this method, especially with patients who are reluctant to undergo surgery because of personal or clinical problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Facial injuries with the retention of foreign bodies inside the tissues, both in soft and hard ones, can cause major functional and aesthetic damage. Among the different etiological agents, cutting tools, fragments of a firearm, the splinter of wood, steel, or iron, launched by misuse, or even caused by defects in equipment, are the main cause of these injuries. The aim of this study was to discuss the peculiarity of the multidisciplinary approach in caring of a 33-year-old man, victim of an accident at work, by the rupture of an emery disc and consequent penetration of the fragments in violation of the tissues in the orbital and zygomatic region of the left side, with perforation of the eyeball and orbital-zygomatic fracture. Urgent treatment consisted of debridement of wounds, bleeding control, removal of foreign bodies, fracture reduction with rigid internal fixation, and suture, performed by the oral and maxillofacial surgical team. Reconstruction of orbital tissues by the ophthalmology team consisted of suture of the injuries. About 1 month after the trauma, phthisis bulbi was noted, and the patient underwent a new procedure under general anesthesia for eye evisceration and installation of an alloplastic prosthesis associated with the homogenous sclera. Facial harmony was restored, especially in aesthetics and function of the zygomatic-orbital complex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sleep bruxism (SB) is characterized by repetitive and coordinated mandible movements and non-functional teeth contacts during sleep time. Although the etiology of SB is controversial, the literature converges on its multifactorial origin. Occlusal factors, smoking, alcoholism, drug usage, stress, and anxiety have been described as SB trigger factors. Recent studies on this topic discussed the role of neurotransmitters on the development of SB.Thus, the purpose of this study was to detect and quantify the urinary levels of catecholamines, specifically of adrenaline, noradrenaline and dopamine, in subjects with SB and in control individuals.Urine from individuals with SB (n = 20) and without SB (n = 20) was subjected to liquid chromatography. The catecholamine data were compared by Mann-Whitney's test (p a parts per thousand currency sign 0.05).Our analysis showed higher levels of catecholamines in subjects with SB (adrenaline = 111.4 A mu g/24 h; noradrenaline = 261,5 A mu g/24 h; dopamine = 479.5 A mu g/24 h) than in control subjects (adrenaline = 35,0 A mu g/24 h; noradrenaline = 148,7 A mu g/24 h; dopamine = 201,7 A mu g/24 h). Statistical differences were found for the three catecholamines tested.It was concluded that individuals with SB have higher levels of urinary catecholamines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)