909 resultados para Ultrasound, Aircraft maintenance
Resumo:
Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 9-12 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. Passing-Bablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
TTCN-kieltä käytetään testitapausten määrittelemiseen tietoliikennejärjestelmissä. Nykyään TTCN:stä on tullut yhä suositumpi tapa toteuttaa testitapauksia. TTCN tarjoaa hyvän ja yksinkertaisen tavan muuntaa käsin testattavat testitapaukset automatisoiduiksi. Tämän diplomityön yhteydessä toteutettiin TTCN testitapaukset WCDMA -tukiaseman käyttö- ja kunnossapito- (O&M) ohjelmistolle. Ohjelmistoa on käytetty myös toisen sukupolven tukiasemissa, mutta kolmannen sukupolven tukiasemissa sillä on huomattavasti isompi rooli. WCDMA -tukiasemassa O&M käsittelee muun muassa tukiaseman käynnistyksen, virhetilanteet ja valvoo tukiaseman komponentteja. Ensimmäisiä tehtäviä diplomityötä tehdessä oli valita ne testitapaukset, jotka olisivat mahdollisia ja hyödyllisiä toteuttaa TTCN:n avulla. Testitapaukset valittiin valmiina olleista testitapausten kuvauksista. Valitut testitapaukset toteutettiin käyttäen rinnakkaista ja modulaarista TTCN-kieltä ja testattiin WCDMA -tukiasemaa vasten käyttäen TTCN Tester ohjelmistoa. Tämän diplomityön yhteydessä toteutettuja testitapauksia käytetään varmistamaan, että tukiasema voi toipua erilaisista virhetilanteista O&M ohjelmiston avulla. Testitapauksia WCDMA -tukiasemaa vasten ajettaessa varmistetaan myös, että O&M ohjelmisto toimii määrittelyn mukaisesti eri tilanteissa. Toteutetut testi tapaukset korvaavat nykyään käsin testatut O&M testi tapaukset tukiaseman O&M ohjelmistoa testatessa. Automatisoidut testi tapaukset tekevät O&M ohjelmiston testaamisen merkittävästi nopeammaksi ja helpommaksi.
Resumo:
CONTEXT: The current standard for diagnosing prostate cancer in men at risk relies on a transrectal ultrasound-guided biopsy test that is blind to the location of the cancer. To increase the accuracy of this diagnostic pathway, a software-based magnetic resonance imaging-ultrasound (MRI-US) fusion targeted biopsy approach has been proposed. OBJECTIVE: Our main objective was to compare the detection rate of clinically significant prostate cancer with software-based MRI-US fusion targeted biopsy against standard biopsy. The two strategies were also compared in terms of detection of all cancers, sampling utility and efficiency, and rate of serious adverse events. The outcomes of different targeted approaches were also compared. EVIDENCE ACQUISITION: We performed a systematic review of PubMed/Medline, Embase (via Ovid), and Cochrane Review databases in December 2013 following the Preferred Reported Items for Systematic reviews and Meta-analysis statement. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. EVIDENCE SYNTHESIS: Fourteen papers reporting the outcomes of 15 studies (n=2293; range: 13-582) were included. We found that MRI-US fusion targeted biopsies detect more clinically significant cancers (median: 33.3% vs 23.6%; range: 13.2-50% vs 4.8-52%) using fewer cores (median: 9.2 vs 37.1) compared with standard biopsy techniques, respectively. Some studies showed a lower detection rate of all cancer (median: 50.5% vs 43.4%; range: 23.7-82.1% vs 14.3-59%). MRI-US fusion targeted biopsy was able to detect some clinically significant cancers that would have been missed by using only standard biopsy (median: 9.1%; range: 5-16.2%). It was not possible to determine which of the two biopsy approaches led most to serious adverse events because standard and targeted biopsies were performed in the same session. Software-based MRI-US fusion targeted biopsy detected more clinically significant disease than visual targeted biopsy in the only study reporting on this outcome (20.3% vs 15.1%). CONCLUSIONS: Software-based MRI-US fusion targeted biopsy seems to detect more clinically significant cancers deploying fewer cores than standard biopsy. Because there was significant study heterogeneity in patient inclusion, definition of significant cancer, and the protocol used to conduct the standard biopsy, these findings need to be confirmed by further large multicentre validating studies. PATIENT SUMMARY: We compared the ability of standard biopsy to diagnose prostate cancer against a novel approach using software to overlay the images from magnetic resonance imaging and ultrasound to guide biopsies towards the suspicious areas of the prostate. We found consistent findings showing the superiority of this novel targeted approach, although further high-quality evidence is needed to change current practice.
Resumo:
Heterozygous germline mutations in the zinc finger transcription factor GATA2 have recently been shown to underlie a range of clinical phenotypes, including Emberger syndrome, a disorder characterized by lymphedema and predisposition to myelodysplastic syndrome/acute myeloid leukemia (MDS/AML). Despite well-defined roles in hematopoiesis, the functions of GATA2 in the lymphatic vasculature and the mechanisms by which GATA2 mutations result in lymphedema have not been characterized. Here, we have provided a molecular explanation for lymphedema predisposition in a subset of patients with germline GATA2 mutations. Specifically, we demonstrated that Emberger-associated GATA2 missense mutations result in complete loss of GATA2 function, with respect to the capacity to regulate the transcription of genes that are important for lymphatic vessel valve development. We identified a putative enhancer element upstream of the key lymphatic transcriptional regulator PROX1 that is bound by GATA2, and the transcription factors FOXC2 and NFATC1. Emberger GATA2 missense mutants had a profoundly reduced capacity to bind this element. Conditional Gata2 deletion in mice revealed that GATA2 is required for both development and maintenance of lymphovenous and lymphatic vessel valves. Together, our data unveil essential roles for GATA2 in the lymphatic vasculature and explain why a select catalogue of human GATA2 mutations results in lymphedema.
Resumo:
Maintenance is a part of system development and it is possible to develop operation models for accomplishing maintenance tasks. These models can be applied to individual maintenance tasks, maintenance projects and version management. Beneficial operation models makes maintenance more effective and they assist in managing various changes. The purpose of this thesis was to develop a maintenance process which can be used to remote administer network servers. This consisted of defining those operation models and technical specifications which enable to set up, manage changes, maintain and monitor resources of information systems that are located in several different sites. At first in this thesis the needs of the process were determined and requirements were defined based on those needs. The meaning of processes in maintenance of information systems, maintenance workflows and challenges were studied. Then current practical problems and disadvantages of maintenance work were analyzed in order to focus the development to proper issues. Because available operation models did not cover all the recent needs, new maintenance process which fulfilled the requirements was developed.
Resumo:
BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.
Resumo:
INTRODUCTION: The performance of ultrasound (US) in the diagnosis of acute gouty (MSU) arthritis and calcium pyrophosphate (CPP) arthritis is not yet well defined. Most studies evaluated US as the basis for diagnosing crystal arthritis in already diagnosed cases of gout and few prospective studies have been performed. METHODS: One hundred nine consecutive patients who presented an acute arthritis of suspected microcrystalline arthritis were prospectively included. All underwent an US of the symptomatic joints(s) and of knees, ankles and 1(st) metatarsopalangeal (MTP) joints by a rheumatologist "blinded" to the clinical history. 92 also had standard X-rays. Crystal identification was the gold standard. RESULTS: Fifty-one patients had MSU, 28 CPP and 9 had both crystals by microscopic analysis. No crystals were detected in 21. One had septic arthritis. Based on US signs in the symptomatic joint, the sensitivity of US for both gout and CPP was low (60 % for both). In gout, the presence of US signs in the symptomatic joint was highly predictive of the diagnosis (PPV = 92 %). When US diagnosis was based on an examination of multiple joints, the sensitivity for both gout and CPP rose significantly but the specificity and the PPV decreased. In the absence of US signs in all the joints studied, CPP arthritis was unlikely (NPV = 87 %) particularly in patients with no previous crisis (NPV = 94 %). X-ray of the symptomatic joints was confirmed to be not useful in diagnosing gout and was equally sensitive or specific as US in CPP arthritis. CONCLUSIONS: Arthrocenthesis remains the key investigation for the diagnosis of microcrystalline acute arthritis. Although US can help in the diagnostic process, its diagnostic performance is only moderate. US should not be limited to the symptomatic joint. Examination of multiple joints gives a better diagnostic sensitivity but lower specificity.
Resumo:
UNLABELLED: The relationship between bone quantitative ultrasound (QUS) and fracture risk was estimated in an individual level data meta-analysis of 9 prospective studies of 46,124 individuals and 3018 incident fractures. Low QUS is associated with an increase in fracture risk, including hip fracture. The association with osteoporotic fracture decreases with time. INTRODUCTION: The aim of this meta-analysis was to investigate the association between parameters of QUS and risk of fracture. METHODS: In an individual-level analysis, we studied participants in nine prospective cohorts from Asia, Europe and North America. Heel broadband ultrasonic attenuation (BUA dB/MHz) and speed of sound (SOS m/s) were measured at baseline. Fractures during follow-up were collected by self-report and in some cohorts confirmed by radiography. An extension of Poisson regression was used to examine the gradient of risk (GR, hazard ratio per 1 SD decrease) between QUS and fracture risk adjusted for age and time since baseline in each cohort. Interactions between QUS and age and time since baseline were explored. RESULTS: Baseline measurements were available in 46,124 men and women, mean age 70 years (range 20-100). Three thousand and eighteen osteoporotic fractures (787 hip fractures) occurred during follow-up of 214,000 person-years. The summary GR for osteoporotic fracture was similar for both BUA (1.45, 95 % confidence intervals (CI) 1.40-1.51) and SOS (1.42, 95 % CI 1.36-1.47). For hip fracture, the respective GRs were 1.69 (95 % CI, 1.56-1.82) and 1.60 (95 % CI, 1.48-1.72). However, the GR was significantly higher for both fracture outcomes at lower baseline BUA and SOS (p < 0.001). The predictive value of QUS was the same for men and women and for all ages (p > 0.20), but the predictive value of both BUA and SOS for osteoporotic fracture decreased with time (p = 0.018 and p = 0.010, respectively). For example, the GR of BUA for osteoporotic fracture, adjusted for age, was 1.51 (95 % CI 1.42-1.61) at 1 year after baseline, but at 5 years, it was 1.36 (95 % CI 1.27-1.46). CONCLUSIONS: Our results confirm that quantitative ultrasound is an independent predictor of fracture for men and women particularly at low QUS values.
Resumo:
The main target of the study was to find ideas for maintenance and development of supplier relations in irregular business environment. The other aim was to find out the suppliers’ opinions concerning the case company and the relationship between the companies. The study was conducted by using both qualitative and quantitative research methods. A mail survey was used to find out supplier opinions and an interview to find out suppliers’ ideas for relationship maintenance and development. It was found out that the use of relational elements is essential in the relationship maintenance in an irregular environment. In development of supplier relations the company should make better use of its suppliers’ potential, assure better flow of information and utilize the possibilities of Supplier Relationship Management.