916 resultados para Thermo stabilizers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper was prepared a polymorphic from of curcumin a natural bioactive compound widely used in Indian medicine in the treatment of a range of illnesses. The preparation was the polymorphic crystallization process and solvent mixtures of organic solvents in order to change the dielectric constant of the solution to obtain crystals. The crystal of curcumin has been studied and characterized by absorption spectroscopic in the infrared, X-ray diffraction powder method and by thermo analytical techniques: thermogravimetry and differential therma analysis (TG-DTA) and differential scanning calorimetry (DSC). The DSC of the pure compound (MP=180,19ºC) showed some differences compared the compound crystallized (MP=176.63ºC) in a mixture of solvents thus indicating the phenomenon of polymorphism, and TG-DTA curve of the compound crystallized showed that this was not a solvatomorphic. Finnally the techniques of X-ray diffraction technique FTIR and powder showed a structural change in the compound crystallized, profile-based graphics when compared to the pure compound, which proves that the compound crystallized it is a polymorph

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is about a case study of using solar energy and wind energy in a farm. For this purpose were collected from the property, such as water consumption and amount of residents. So, we estimate how many conventional panels or PET bottle panels and boiler needed to supply the farm with warm water. It also calculates the amount of photovoltaic panels and the main accessories for converting solar energy into electrical energy. For the pumping of water using photovoltaic panels is dismissed and dimensioned to be a watermill

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concern of the society with regard to the pollution if becomes each bigger and necessary time. This pollution generates damage for who is in contact, as much in economic terms how much in quality of life. The particulate matter is one of the main polluting the air, being the most harmful to human health, fine particles and ultra fine (below 2.5 μm in diameter). With this, this work had as objective to mensurar the pollution of air for material particulado through samplings in an urban center, in a siderurgical industry, a conventional coal bunker and a forest fire. The equipment used for the sampling of particles had been the DataRam4 (model DR 4000) and the Impactador de Andersen, both developed by company THERMO SCIENTIFIC. The first equipment uses a system of nefelometry and the second uses a gravimetrical system of sampling. During the carried through samplings, it can be observed in some cases the difficulty in the breath, badly be and low visibility that this type of pollutant can cause. In most cases the results were disturbing. In industry, conventional coal bunker and in the forest were measured values high concentration for particles smaller diameters. Peak concentrations issued were: 40,000 μg/m³, 182,000 μg/m³ and 400,000 μg/m³ for the industry, conventional coal bunker and forest, respectively. Already in the urban centre were satisfactory results, always staying within the limit allowed by the rules in force so far in the country

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current world's need for clean and renewable energy sources aligned with the strong Brazilian growth looking to diversify its electric power generation sources, highly dependent on hydropower and petroleum encourages the implementation of technologies that reach this growth with diversity and cleaning. The sun energy source is considered inexhaustible and can meet the demand for energy through thermo solar plants to generate electricity. Several technologies are being studied and developed in the world and they can be used to generate electricity from the solar concentration, but in Brazil its use is still not found commercially. It is therefore essential to understand these technologies and develop knowledge about them so they can be implemented in Brazil. This work brings an overview of the thermo solar generation in Brazil, showing the different technologies and a thermodynamic simulation of one of such technologies considering a hybrid plant with complementary generation biomass, aiming at the generation of 1 MW in the Brazilian Northeast

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to study resin distribution and homogeneity of composite laminates manufactured by RTM, it was used CYCOM 890 monolithic toughened epoxy as a matrix with two different configurations of intermediated modulus (IM) carbon fibers: Satin Weave (5HS) and non crimp fabric (NCF). The injection parameters were defined based on Thermo Gravimetric Analysis (TG), Differential Scanning Calorimetry (DSC) and rheological analysis. After processing the material, the resin/fiber impregnation was studied using ultrasonic test, Thermo Gravimetric Analysis, Differential Scanning Calorimetry, Dynamic Mechanical Analysis (DMA) and flexural tests. Therefore, it was able to observe an internal residual stress during the cooling process in both laminates, higher in the composite using NCF fabric due to the lack of symmetry, although a good proportion of fiber/matrix has been verified by the lower values of flexural modulus deviation. The DMA enabled the visualization of glass transition and its association with the inter and intra molecular interaction and movement, in which the NCF composite presented better permeability due to the lowest temperature of glass transition, when compared to the Satin Weave composite

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lately, the acceptability of fermented dairy beverages has been increased, due to the nutritional benefits, the practical consumption and the low cost of product for the manufacturers, and consequently for final market price to the consumers. During the manufacturing process, these products can be susceptible to microbiological contamination. The present study investigated the contaminant microbiota in fermented dairy beverages produced by small- and medium-sized companies, by means of analyses on moulds and yeasts counting, determination of the Most Probable Number (MPN) of total and thermo tolerant coliforms, Escherichia coli and Salmonella spp. detection, and determination of pH value. In spite of the absence of Salmonella spp., a high counts of yeasts and moulds were found, and E. coli was detected in five samples (16.67 %); and the sample were classified as “products in poor sanitary conditions”, because they showed thermo-tolerant coliforms counting higher than the standard established by the legislation in force. Therefore, quality programs such as Good Manufacturing Practices (GMP) and Hazard Analysis and Critical Control Points (HACCP) should be employed to prevent any contamination risk, in order to provide safe products to consumers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

National Council for Scientific and Technological Development (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study investigated the repairs of resin composite restorations after using different surface treatments.Design: Eighty four truncated cones of Filtek Z350 were prepared and thermo-cycled (20,000 cycles). Surfaces were roughened with diamond bur and etched with 37% phosphoric acid. Those cones were divided into 7 groups (N=12): 1) Prime&Bond 2.1; 2) aluminum oxide sandblasting+Prime&Bond 2.1; 3) Er:YAG laser treatment+Prime&Bond 2.1; 4) 9.6% hydrofluoric acid for 2 min-Fsilane coupling agent.; 5) silane coupling agent; 6) auto-polymerized acrylic monomer+Prime&Bond 2.1; 7) Adper Scothbond SE. Teflon device was used to fabricate inverted truncated cones of repair composite over the surface-treated. The bonded specimens were stressed to failure under tension. The data were analyzed with oneway ANOVA and Tukey tests.Results: Mean repair strengths (SD, in MPa) were, Group-2: 18.8a; Group-1: 18.7a; Group-6: 13.4ab; Group-7: 9.5bc; Group-3: 7.5bcd; Group-4: 5.2cd; Group-5: 2.6d.Conclusions: The use of diamond bur and a conventional adhesive and the use of aluminum oxide sandblasting prior to adhesive provided a simple and cost-effective solutions to composite repair. Er:YAG laser, silane alone, 9.6% hydrofluoric acid plus silane or a self-etching adhesive results in inferior composite repair strengths. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed at quantifies the pain in dogs under dissociative anesthesia, across thermal and pressoric stimulus and quantify the reasonable period between two different opioids analgesics. In this study, 30 dogs were used and, divided into three groups of 10 animals each, in which the animals of GI received methotrimeprazine and midazolam put on the same syringe with ketamine. The animals of GII received the same treatment of GI but associated with butorphanol and finally the animals of GIII received the same treatment of GI but associated with buprenorphine. The routine parametric evaluations has been proceeded, although using the thermo algimetry measured in degrees C with the average of 52 degrees C and the pressoric algimetry in Kg. In the thermo algimetry, there has been significant difference in GI at the moments M0, M1, M4 and M5; in GII it was found at M0, M1, M5 and M6 and in GIII it was observed the significant at M0 and M1. It has also been shown in pressoric algimetry significant difference in GI at the moments M0, M2 and M3. Among GII it has observed significant difference at all moments and it has found at M0, M9 in GIII. Thus, it has observed significant differences between all groups; for such the M2 of GII smaller than the others; and M4, M5 of GIII bigger than GI and GII. In the assessment of all periods it was observed significant latent period bigger in GI, however, with reasonable period and short recovery in GII and GIII. In the order hand, the postural tonus recovery it was longer in GIII, followed by GII and finally GI. The used method for the measurement of algic stimulus was efficient, noticing a reasonable analgesic period of 3 hours for butorphanol and 6 hours for buprenorphine.