916 resultados para Test, Black-box testing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water is vital to humans and each of us needs at least 1.5 L of safe water a day to drink. Beginning as long ago as 1958 the World Health Organization (WHO) has published guidelines to help ensure water is safe to drink. Focused from the start on monitoring radionuclides in water, and continually cooperating with WHO, the International Standardization Organization (ISO) has been publishing standards on radioactivity test methods since 1978. As reliable, comparable and"fit for purpose" results are an essential requirement for any public health decision based on radioactivity measurements, international standards of tested and validated radionuclide test methods are an important tool for production of such measurements. This paper presents the ISO standards already published that could be used as normative references by testing laboratories in charge of radioactivity monitoring of drinking water as well as those currently under drafting and the prospect of standardized fast test methods in response to a nuclear accident.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

TTCN-kieltä käytetään testitapausten määrittelemiseen tietoliikennejärjestelmissä. Nykyään TTCN:stä on tullut yhä suositumpi tapa toteuttaa testitapauksia. TTCN tarjoaa hyvän ja yksinkertaisen tavan muuntaa käsin testattavat testitapaukset automatisoiduiksi. Tämän diplomityön yhteydessä toteutettiin TTCN testitapaukset WCDMA -tukiaseman käyttö- ja kunnossapito- (O&M) ohjelmistolle. Ohjelmistoa on käytetty myös toisen sukupolven tukiasemissa, mutta kolmannen sukupolven tukiasemissa sillä on huomattavasti isompi rooli. WCDMA -tukiasemassa O&M käsittelee muun muassa tukiaseman käynnistyksen, virhetilanteet ja valvoo tukiaseman komponentteja. Ensimmäisiä tehtäviä diplomityötä tehdessä oli valita ne testitapaukset, jotka olisivat mahdollisia ja hyödyllisiä toteuttaa TTCN:n avulla. Testitapaukset valittiin valmiina olleista testitapausten kuvauksista. Valitut testitapaukset toteutettiin käyttäen rinnakkaista ja modulaarista TTCN-kieltä ja testattiin WCDMA -tukiasemaa vasten käyttäen TTCN Tester ohjelmistoa. Tämän diplomityön yhteydessä toteutettuja testitapauksia käytetään varmistamaan, että tukiasema voi toipua erilaisista virhetilanteista O&M ohjelmiston avulla. Testitapauksia WCDMA -tukiasemaa vasten ajettaessa varmistetaan myös, että O&M ohjelmisto toimii määrittelyn mukaisesti eri tilanteissa. Toteutetut testi tapaukset korvaavat nykyään käsin testatut O&M testi tapaukset tukiaseman O&M ohjelmistoa testatessa. Automatisoidut testi tapaukset tekevät O&M ohjelmiston testaamisen merkittävästi nopeammaksi ja helpommaksi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simulaattorit ovat yksinkertaistettuja malleja tietyistä järjestelmän osioista. Niitä käytetään mallintamaan testattavan osion ympärillä olevien muiden osioiden ulkoista toimintaa, jotta testattavalle osiolle saadaan oikeanlainen toimintaympäristö aikaiseksi. Tilakoneita käytetään mallintamaan ohjelmistojen tai niiden osien toimintaa. Sanomaohjatuissa tilakoneissa tilojen vaihdot perustuvat saapuviin sanomiin. Tässä työssä esitellään erään ohjelmiston alijärjestelmän testaamisessa käytettävä arkkitehtuuri, joka perustuu suurelta osin simulaattoreiden käyttöön muiden alijärjestelmien mallintamisessa. Testattava ohjelmisto koostuu enimmäkseen tilakoneista, jotka vaihtavat keskenään sanomia ja ohjaavat näin toistensa tilasiirtymiä. Työn testausympäristö on suunniteltu juuri tämänkaltaisen ohjelmiston testaamiseen. Työssä esiteltävää testausympäristöä myöskin käytettiin useamman kuukauden ajan ja se todettiin toimivaksi. Joitakin testausympäristön käyttöohjeita, käyttökokemuksia sekä siihen liittyviä parannusehdotuksia käydään läpi työn loppuosassa. Erityisesti havaittiin miten tärkeää on testata implementaatiota jo luokka tasolla ennen alijärjestelmä tason testaukseen siirtymistä sekä päädyttiin siihen, että suunnitteluvaiheen pitäisi olla lähemmin liitoksissa alijärjestelmätestaukseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Suorituskyky- ja kuormitustestien tekeminen sovelluksille on erittäin tärkeä osa tuotantoprosessia nykypäivänä. Myös Web-sovelluksia testataan yhä enemmän. Tarve suorituskyky- ja kuormitustestien tekemiselle on selvä. Testattavan ympäristön tämänhetkinen, mutta myös tulevaisuuden toimivuus taataan oikein tehdyillä testeillä ja niitä seuraavilla korjaustoimenpiteillä. Suurten käyttäjämäärien testaaminen manuaalisesti on kuitenkin hyvin vaikeaa. Sirpaleisen ympäristön, kuten palveluihin perustuvien Web-sovellusympäristöjen testaaminen on haaste. Tämän työn aiheena on arvioida työkaluja ja menetelmiä, joilla raskaita teollisia Web-sovelluksia voidaan testata. Tavoitteena on löytää testausmenetelmiä, joilla voidaan luotettavasti simuloida suuria käyttäjämääriä. Tavoitteena on myös arvioida erilaisten yhteyksien ja protokollien vaikutusta Web-sovelluksen suorituskykyyn.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Differentiation between photoallergenic and phototoxic reactions induced by low molecular weight compounds represents a current problem. The use of eratinocytes as a potential tool for the detection of photoallergens as opposed to photoirritants is considered an interesting strategy for developing in vitro methods. We have previously demonstrated the possibility to use the human keratinocyte cell line NCTC2455 and the production of interleukin-18 (IL-18) to screen low molecular weight sensitizers. The purpose of this work was to explore the possibility to use the NCTC2544 assay to identify photoallergens and discriminate from phototoxic chemicals. First, we identified suitable condition of UV-irradiation (3.5 J/cm2) by investigating the effect of UVAirradiation on intracellular IL-18 on untreated or chloropromazine (a representative phototoxic compound)- treated NCTC2544 cells. Then, the effect of UVA-irradiation over NCTC2544 cells treated with increasing concentrations of 15 compounds including photoallergens (benzophenone, 4-ter-butyl-4-methoxydibenzoylmethane, 2-ethylexyl-p-methoxycinnamate, ketoprofen, 6-methylcumarin); photoirritant and photoallergen (4-aminobenzoic acid, chlorpromazine, promethazine); photoirritants (acridine, ibuprofen, 8-methoxypsoralen, retinoic acid); and negative compounds (lactic acid, SDS and p-phenilendiamine) was investigated. Twenty-four hours after exposure, cytotoxicity was evaluated by the MTT assay or LDH leakage, while ELISA was used to measure the production of IL-18. At the maximal concentration assayed with non-cytotoxic effects (CV80 under irradiated condition), all tested photoallergens induced a significant and a dose-dependent increase of intracellular IL-18 following UVA irratiation, whereas photoirritants failed. We suggest that this system may be useful for the in vitro evaluation of the photoallergic potential of chemicals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Teollusuussovelluksissa vaaditaan nykyisin yhä useammin reaaliaikaista tiedon käsittelyä. Luotettavuus on yksi tärkeimmistä reaaliaikaiseen tiedonkäsittelyyn kykenevän järjestelmän ominaisuuksista. Sen saavuttamiseksi on sekä laitteisto, että ohjelmisto testattava. Tämän työn päätavoitteena on laitteiston testaaminen ja laitteiston testattavuus, koska luotettava laitteistoalusta on perusta tulevaisuuden reaaliaikajärjestelmille. Diplomityössä esitetään digitaaliseen signaalinkäsittelyyn soveltuvan prosessorikortin suunnittelu. Prosessorikortti on tarkoitettu sähkökoneiden ennakoivaa kunnonvalvontaa varten. Uusimmat DFT (Desing for Testability) menetelmät esitellään ja niitä sovelletaan prosessorikortin sunnittelussa yhdessä vanhempien menetelmien kanssa. Kokemukset ja huomiot menetelmien soveltuvuudesta raportoidaan työn lopussa. Työn tavoitteena on kehittää osakomponentti web -pohjaiseen valvontajärjestelmään, jota on kehitetty Sähkötekniikan osastolla Lappeenrannan teknillisellä korkeakoululla.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monet ohjelmistoyritykset ovat alkaneet kiinnittää yhä enemmän huomiota ohjelmistotuotteidensa laatuun. Tämä on johtanut siihen, että useimmat niistä ovat valinneet ohjelmistotestauksen välineeksi, jolla tätä laatua voidaan parantaa. Testausta ei pidä rajoittaa ainoastaan ohjelmistotuotteeseen itseensä, vaan sen tulisi kattaa koko ohjelmiston kehitysprosessi. Validaatiotestauksessa keskitytään varmistamaan, että lopputuote täyttää sille asetetut vaatimukset, kun taas verifikaatiotestausta käytetään ennaltaehkäisevänä testauksena, jolla pyritään poistamaan virheitä jo ennenkuin ne pääsevät lähdekoodiin asti. Työ, johon tämä diplomityö perustuu, tehtiin alkukevään ja kesän aikana vuonna 2003 Necsom Oy:n toimeksiannosta. Necsom on pieni suomalainen ohjelmistoyritys, jonka tutkimus- ja kehitysyksikkö toimii Lappeenrannassa.Tässä diplomityössä tutustutaan aluksi ohjelmistotestaukseen sekä eri tapoihin sen organisoimiseksi. Tämän lisäksi annetaan yleisiä ohjeita testisuunnitelmien ja testaustapausten tekoon, joita onnistunut ja tehokas testaus edellyttää. Kun tämä teoria on käyty läpi, esitetään esimerkkinä kuinka sisäinen ohjelmistotestaus toteutettiin Necsomilla. Lopuksi esitetään johtopäätökset, joihin päädyttiin käytännön testausprosessin seuraamisen jälkeen ja annetaan jatkotoimenpide-ehdotuksia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diplomityö käsittelee ISO:n yhdenmukaisuustestin menetelmien sekä ISO-9646:n kehysten soveltamista Mobile IPv6 protokollan testauksessa. Mobile IPv6 protokollaa tarkastellaan määrittelyjen pohjalta, myös testien tärkeyttä ja tulosten johtamista käsitellään. Työssä käsitellän MSC:n (Message Sequence Charts) käyttöä testaustyössä mahdolliset edut huomioiden. TTCN kieli, testausmenetelmät ja OpenTTCN testauskone käsitellään. Testin kohteena olevien yhdyskäytävän ja palvelimen määrittelyt kuvataan. Osia abstract test suite :sta (ATS) esitellään esimerkin antamiseksi todellisesta sovelluksesta ja sen yhteydestä tehtyyn dokumenttiin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study the performance measurement, a part of the research and development of the RNC, was improved by implementing counter testing to the Nokia Automation System. The automation of counter testing is a feature the customer ordered, because performing counter testing manually is rather complex. The objective was to implement an automated counter testing system, which once configured correctly, would manage to run the testing and perform the analysis. The requirements for the counter testing were first studied. It was investigated if the auto-mation of the feature was feasible in the meetings with the customer. The basic functionality required for the automation was also drawn. The technologies used in the architecture of the Nokia Automation System were studied. Based on the results of the study, a new technology, wxWidgets, was introduced. The new technology was necessary to facilitate the implementing of the required feature. Finally the implementation of the counter testing was defined and implemented. The result of this study was the automation of the counter testing method developed as a new feature for the Nokia Automation System. The feature meets the specifications and requirements set by the customer. The performing of the counter testing feature is totally automated. Only configuration of the test cases is done by the user. The customer has presented new requests to further develop the feature and there are plans by the Nokia Automation System developers to implement those in the near future. The study describes the implementation of the counter testing feature introduced. The results of the study give guidelines for further developing the feature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Molecular tests for breast cancer (BC) risk assessment are reimbursed by health insurances in Switzerland since the beginning of year 2015. The main current role of these tests is to help oncologists to decide about the usefulness of adjuvant chemotherapy in patients with early stage endocrine-sensitive and human epidermal growth factor receptor 2 (HER2)-negative BC. These gene expression signatures aim at predicting the risk of recurrence in this subgroup. One of them (OncotypeDx/OT) also predicts distant metastases rate with or without the addition of cytotoxic chemotherapy to endocrine therapy. The clinical utility of these tests -in addition to existing so-called "clinico-pathological" prognostic and predictive criteria (e.g. stage, grade, biomarkers status)-is still debated. We report a single center one year experience of the use of one molecular test (OT) in clinical decision making. Methods. We extracted from the CHUV Breast Cancer Center data base the total number of BC cases with estrogen-receptor positive (ER+), HER2-negative early breast cancer (node negative (pN0) disease or micrometastases in up to 3 lymph nodes) operated between September 2014 and August 2015. For the cases from this group in which a molecular test had been decided by the tumor board, we collected the clinicopathologic parameters, the initial tumor board decision, and the final adjuvant systemic therapy decision. Results. A molecular test (OT) was done in 12.2% of patients with ER + HER2 negative early BC. The median age was 57.4 years and the median invasive tumor size was 1.7 cm. These patients were classified by ODX testing (Recurrence Score) into low-, intermediate-, and high risk groups, respectively in 27.2%, 63.6% and 9% of cases. Treatment recommendations changed in 18.2%, predominantly from chemotherapyendocrine therapy to endocrine treatment alone. Of 8 patients originally recommended chemotherapy, 25% were recommended endocrine treatment alone after receiving the Recurrence Score result. Conclusions. Though reimbursed by health insurances since January 2015, molecular tests are used moderately in our institution as per the decision of the multidisciplinary tumor board. It's mainly used to obtain a complementary confirmation supporting the decision of no chemotherapy. The OncotypeDx Recurrence Score results were in the intermediate group in 66% of the 9 tested cases but contributed to avoid chemotherapy in 2 patients during the last 12 months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Testing of a complex software is time consuming. Automated tools are available quite a lot for desktop applications, but for embedded systems a custom-made tool is required Building a complete test framework is a complicated task. Therefore, the test platform was built on top of an already existing tool, CANoe. CANoe is a tool for CAN bus analysis and node simulation. The functionality of CANoe was extended with LabVIEW DLL. The LabVIEW software was used for simulating hardware components of the embedded device As a result of the study, a platform was created where tests could be automated. Of the current test plan, 10 percent were automated and up to 60 percent could be automated with the current functionality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major problem in developmental neurotoxicity (DNT) risk assessment is the lack of toxicological hazard information for most compounds. Therefore, new approaches are being considered to provide adequate experimental data that allow regulatory decisions. This process requires a matching of regulatory needs on the one hand and the opportunities provided by new test systems and methods on the other hand. Alignment of academically and industrially driven assay development with regulatory needs in the field of DNT is a core mission of the International STakeholder NETwork (ISTNET) in DNT testing. The first meeting of ISTNET was held in Zurich on 23-24 January 2014 in order to explore the concept of adverse outcome pathway (AOP) to practical DNT testing. AOPs were considered promising tools to promote test systems development according to regulatory needs. Moreover, the AOP concept was identified as an important guiding principle to assemble predictive integrated testing strategies (ITSs) for DNT. The recommendations on a road map towards AOP-based DNT testing is considered a stepwise approach, operating initially with incomplete AOPs for compound grouping, and focussing on key events of neurodevelopment. Next steps to be considered in follow-up activities are the use of case studies to further apply the AOP concept in regulatory DNT testing, making use of AOP intersections (common key events) for economic development of screening assays, and addressing the transition from qualitative descriptions to quantitative network modelling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different types of aerosolization and deagglomeration testing systems exist for studying the properties of nanomaterial powders and their aerosols. However, results are dependent on the specific methods used. In order to have well-characterized aerosols, we require a better understanding of how system parameters and testing conditions influence the properties of the aerosols generated. In the present study, four experimental setups delivering different aerosolization energies were used to test the resultant aerosols of two distinct nanomaterials (hydrophobic and hydrophilic TiO2). The reproducibility of results within each system was good. However, the number concentrations and size distributions of the aerosols created varied across the four systems; for number concentrations, e.g., from 10(3) to 10(6) #/cm(3). Moreover, distinct differences were also observed between the two materials with different surface coatings. The article discusses how system characteristics and other pertinent conditions modify the test results. We propose using air velocity as a suitable proxy for estimating energy input levels in aerosolization systems. The information derived from this work will be especially useful for establishing standard operating procedures for testing nanopowders, as well as for estimating their release rates under different energy input conditions, which is relevant for occupational exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La dermatite irritative est décrite comme une réaction réversible, non immunologique caractérisée par des lésions d'aspect très variable, allant de la simple rougeur jusqu'à la formation de bulles voire d'une nécrose, accompagnée de prurit ou d'une sensation de brûlure suite à I' application d'une substance chimique. Le teste de prédiction d'irritation cutanée est traditionnellement depuis les années 1940 le Test de Draize. Ce test consiste en l'application d'une substance chimique sur une peau rasée de lapin pendant 4h et de regarder à 24h si des signes cliniques d'irritations sont présents. Cette méthode critiquable autant d'un point de vue éthique que qualitative reste actuellement le teste le plus utilisé. Depuis le début des années 2000 de nouvelles méthodes in vitro se sont développées tel que le model d'épiderme humain recombiné (RHE). Il s agit d'une multicouche de kératinocyte bien différencié obtenu depuis une culture de don d'ovocyte. Cependant cette méthode en plus d'être très couteuse n'obtient au mieux que 76% de résultat similaire comparé au test in vivo humain. Il existe donc la nécessité de développer une nouvelle méthode in vitro qui simulerait encore mieux la réalité anatomique et physiologique retrouvée in vivo. Notre objectif a été de développer cette nouvelle méthode in vitro. Pour cela nous avons travaillé avec de la peau humaine directement prélevée après une abdominoplastie. Celle ci après préparation avec un dermatome, un couteau dont la lame est réglable pour découper l'épaisseur souhaitée de peau, est montée dans un système de diffusion cellulaire. La couche cornée est alors exposée de manière optimale à 1 ml de la substance chimique testée pendant 4h. L'échantillon de peau est alors fixé dans du formaldéhyde pour permettre la préparation de lames standards d'hématoxyline et éosine. L'irritation est alors investiguée selon des critères histopathologiques de spongioses, de nécroses et de vacuolisations cellulaires. Les résultats de ce.tte première batterie de testes sont plus que prometteurs. En effet, comparé au résultat in vivo, nous obtenons 100% de concordance pour les 4 même substances testes irritantes ou non irritantes, ce qui est supérieur au model d épiderme humain recombiné (76%). De plus le coefficient de variation entre les 3 différentes séries est inférieur à 0.1 ce qui montre une bonne reproductibilité dans un même laboratoire. Dans le futur cette méthode va devoir être testée avec un plus grand nombre de substances chimiques et sa reproductibilité évaluée dans différents laboratoires. Mais cette première evaluation, très encourageante, ouvre des pistes précieuses pour l'avenir des tests irritatifs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.