625 resultados para THERMOLUMINESCENCE DOSIMETRY PHOSPHOR


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monte-Carlo (MC) methods are a valuable tool for dosimetry in radiotherapy, including Intra-Operative Electron Radiotherapy (IOERT), since effects such as inhomogeneities or beam hardening may be realistically reproduced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La iluminación con diodos emisores de luz (LED) está reemplazando cada vez en mayor medida a las fuentes de luz tradicionales. La iluminación LED ofrece ventajas en eficiencia, consumo de energía, diseño, tamaño y calidad de la luz. Durante más de 50 años, los investigadores han estado trabajando en mejoras LED. Su principal relevancia para la iluminación está aumentando rápidamente. Esta tesis se centra en un campo de aplicación importante, como son los focos. Se utilizan para enfocar la luz en áreas definidas, en objetos sobresalientes en condiciones profesionales. Esta iluminación de alto rendimiento requiere una calidad de luz definida, que incluya temperaturas ajustables de color correlacionadas (CCT), de alto índice de reproducción cromática (CRI), altas eficiencias, y colores vivos y brillantes. En el paquete LED varios chips de diferentes colores (rojo, azul, fósforo convertido) se combinan para cumplir con la distribución de energía espectral con alto CRI. Para colimar la luz en los puntos concretos deseados con un ángulo de emisión determinado, se utilizan blancos sintonizables y diversos colores de luz y ópticas secundarias. La combinación de una fuente LED de varios colores con elementos ópticos puede causar falta de homogeneidad cromática en la distribución espacial y angular de la luz, que debe resolverse en el diseño óptico. Sin embargo, no hay necesidad de uniformidad perfecta en el punto de luz debido al umbral en la percepción visual del ojo humano. Por lo tanto, se requiere una descripción matemática del nivel de uniformidad del color con respecto a la percepción visual. Esta tesis está organizada en siete capítulos. Después de un capítulo inicial que presenta la motivación que ha guiado la investigación de esta tesis, en el capítulo 2 se presentan los fundamentos científicos de la uniformidad del color en luces concentradas, como son: el espacio de color aplicado CIELAB, la percepción visual del color, los fundamentos de diseño de focos respecto a los motores de luz y ópticas no formadoras de imágenes, y los últimos avances en la evaluación de la uniformidad del color en el campo de los focos. El capítulo 3 desarrolla diferentes métodos para la descripción matemática de la distribución espacial del color en un área definida, como son la diferencia de color máxima, la desviación media del color, el gradiente de la distribución espacial de color, así como la suavidad radial y axial. Cada función se refiere a los diferentes factores que influyen en la visión, los cuales necesitan un tratamiento distinto que el de los datos que se tendrán en cuenta, además de funciones de ponderación que pre- y post-procesan los datos simulados o medidos para la reducción del ruido, la luminancia de corte, la aplicación de la ponderación de luminancia, la función de sensibilidad de contraste, y la función de distribución acumulativa. En el capítulo 4, se obtiene la función de mérito Usl para la estimación de la uniformidad del color percibida en focos. Se basó en los resultados de dos conjuntos de experimentos con factor humano realizados para evaluar la percepción visual de los sujetos de los patrones de focos típicos. El primer experimento con factor humano dio lugar al orden de importancia percibida de los focos. El orden de rango percibido se utilizó para correlacionar las descripciones matemáticas de las funciones básicas y la función ponderada sobre la distribución espacial del color, que condujo a la función Usl. El segundo experimento con factor humano probó la percepción de los focos bajo condiciones ambientales diversas, con el objetivo de proporcionar una escala absoluta para Usl, para poder así sustituir la opinión subjetiva personal de los individuos por una función de mérito estandarizada. La validación de la función Usl se presenta en relación con el alcance de la aplicación y condiciones, así como las limitaciones y restricciones que se realizan en el capítulo 5. Se compararon los datos medidos y simulados de varios sistemas ópticos. Se discuten los campos de aplicación , así como validaciones y restricciones de la función. El capítulo 6 presenta el diseño del sistema de focos y su optimización. Una evaluación muestra el análisis de sistemas basados en el reflector y la lente TIR. Los sistemas ópticos simulados se comparan en la uniformidad del color Usl, sensibilidad a las sombras coloreadas, eficiencia e intensidad luminosa máxima. Se ha comprobado que no hay un sistema único que obtenga los mejores resultados en todas las categorías, y que una excelente uniformidad de color se pudo alcanzar por la conjunción de dos sistemas diferentes. Finalmente, el capítulo 7 presenta el resumen de esta tesis y la perspectiva para investigar otros aspectos. ABSTRACT Illumination with light-emitting diodes (LED) is more and more replacing traditional light sources. They provide advantages in efficiency, energy consumption, design, size and light quality. For more than 50 years, researchers have been working on LED improvements. Their main relevance for illumination is rapidly increasing. This thesis is focused on one important field of application which are spotlights. They are used to focus light on defined areas, outstanding objects in professional conditions. This high performance illumination required a defined light quality including tunable correlated color temperatures (CCT), high color rendering index (CRI), high efficiencies and bright, vivid colors. Several differently colored chips (red, blue, phosphor converted) in the LED package are combined to meet spectral power distribution with high CRI, tunable white and several light colors and secondary optics are used to collimate the light into the desired narrow spots with defined angle of emission. The combination of multi-color LED source and optical elements may cause chromatic inhomogeneities in spatial and angular light distribution which needs to solved at the optical design. However, there is no need for perfect uniformity in the spot light due to threshold in visual perception of human eye. Therefore, a mathematical description of color uniformity level with regard to visual perception is required. This thesis is organized seven seven chapters. After an initial one presenting the motivation that has guided the research of this thesis, Chapter 2 introduces the scientific basics of color uniformity in spot lights including: the applied color space CIELAB, the visual color perception, the spotlight design fundamentals with regards to light engines and nonimaging optics, and the state of the art for the evaluation of color uniformity in the far field of spotlights. Chapter 3 develops different methods for mathematical description of spatial color distribution in a defined area, which are the maximum color difference, the average color deviation, the gradient of spatial color distribution as well as the radial and axial smoothness. Each function refers to different visual influencing factors, and they need different handling of data be taken into account, along with weighting functions which pre- and post-process the simulated or measured data for noise reduction, luminance cutoff, the implementation of luminance weighting, contrast sensitivity function, and cumulative distribution function. In chapter 4, the merit function Usl for the estimation of the perceived color uniformity in spotlights is derived. It was based on the results of two sets of human factor experiments performed to evaluate the visual perception of typical spotlight patterns by subjects. The first human factor experiment resulted in the perceived rank order of the spotlights. The perceived rank order was used to correlate the mathematical descriptions of basic functions and weighted function concerning the spatial color distribution, which lead to the Usl function. The second human factor experiment tested the perception of spotlights under varied environmental conditions, with to objective to provide an absolute scale for Usl, so the subjective personal opinion of individuals could be replaced by a standardized merit function. The validation of the Usl function is presented concerning the application range and conditions as well as limitations and restrictions in carried out in chapter 5. Measured and simulated data of various optical several systems were compared. Fields of applications are discussed as well as validations and restrictions of the function. Chapter 6 presents spotlight system design and their optimization. An evaluation shows the analysis of reflector-based and TIR lens systems. The simulated optical systems are compared in color uniformity Usl , sensitivity to colored shadows, efficiency, and peak luminous intensity. It has been found that no single system which performed best in all categories, and that excellent color uniformity could be reached by two different system assemblies. Finally, chapter 7 summarizes the conclusions of the present thesis and an outlook for further investigation topics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem digital adquirida pelo sistema da placa de fósforo foto ativada é visualizada no monitor do computador em um formato denominado DICOM. Este formato ocupa muito espaço para armazenamento, o que dificulta o arquivamento e transmissão da imagem pela Internet. O objetivo deste estudo foi avaliar a influência da compressão JPEG, nos Fatores de Qualidade 100, 80 e 60 na reprodutibilidade da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 120 imagens de telerradiografias em norma lateral obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital no formato DICOM. Essas imagens foram convertidas para o formato JPEG. Após o cegamento e randomização da amostra, três Ortodontistas calibrados marcaram a localização de 12 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas X e Y. Esse procedimento foi repetido após 1 mês. A reprodutibilidade intra e inter observador foi calculada usando o teste de correlação intraclasse. Para comparação entre os grupos de compressão e DICOM na reprodutibilidade de marcação dos pontos utilizou se a Análise de Variância (ANOVA) a um critério para medidas repetidas. Os resultados mostraram que as marcações dos pontos cefalométricos foram bastante reprodutíveis, exceto para o ponto Órbita na coordenada X. Os diferentes formatos de arquivo mostraram estatisticamente iguais para cada ponto e eixo aferido. As compressões JPEG estudadas das imagens de telerradiografias em norma lateral não tiveram efeito na reprodutibilidade da marcação dos pontos cefalométricos testados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem digital adquirida pelo sistema da placa de fósforo foto ativada é visualizada no monitor do computador em um formato denominado DICOM. Este formato ocupa muito espaço para armazenamento, o que dificulta o arquivamento e transmissão da imagem pela Internet. O objetivo deste estudo foi avaliar a influência da compressão JPEG, nos Fatores de Qualidade 100, 80 e 60 na reprodutibilidade da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 120 imagens de telerradiografias em norma lateral obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital no formato DICOM. Essas imagens foram convertidas para o formato JPEG. Após o cegamento e randomização da amostra, três Ortodontistas calibrados marcaram a localização de 12 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas X e Y. Esse procedimento foi repetido após 1 mês. A reprodutibilidade intra e inter observador foi calculada usando o teste de correlação intraclasse. Para comparação entre os grupos de compressão e DICOM na reprodutibilidade de marcação dos pontos utilizou se a Análise de Variância (ANOVA) a um critério para medidas repetidas. Os resultados mostraram que as marcações dos pontos cefalométricos foram bastante reprodutíveis, exceto para o ponto Órbita na coordenada X. Os diferentes formatos de arquivo mostraram estatisticamente iguais para cada ponto e eixo aferido. As compressões JPEG estudadas das imagens de telerradiografias em norma lateral não tiveram efeito na reprodutibilidade da marcação dos pontos cefalométricos testados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The D2 polypeptide of the photosystem II (PSII) complex in the green alga Chlamydomonas reinhardtii is thought to be reversibly phosphorylated. By analogy to higher plants, the phosphorylation site is likely to be at residue threonine-2 (Thr-2). We have investigated the role of D2 phosphorylation by constructing two mutants in which residue Thr-2 has been replaced by either alanine or serine. Both mutants grew photoautotrophically at wild-type rates, and noninvasive biophysical measurements, including the decay of chlorophyll fluorescence, the peak temperature of thermoluminescence bands, and rates of oxygen evolution, indicate little perturbation to electron transfer through the PSII complex. The susceptibility of mutant PSII to photoinactivation as measured by the light-induced loss of PSII activity in whole cells in the presence of the protein-synthesis inhibitors chloramphenicol or lincomycin was similar to that of wild type. These results indicate that phosphorylation at Thr-2 is not required for PSII function or for protection from photoinactivation. In control experiments the phosphorylation of D2 in wild-type C. reinhardtii was examined by 32P labeling in vivo and in vitro. No evidence for the phosphorylation of D2 in the wild type could be obtained. [14C]Acetate-labeling experiments in the presence of an inhibitor of cytoplasmic protein synthesis also failed to identify phosphorylated (D2.1) and nonphosphorylated (D2.2) forms of D2 upon sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Our results suggest that the existence of D2 phosphorylation in C. reinhardtii is still in question.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermoluminescence (TL) signals were recorded from grana stacks, margins, and stroma lamellae from fractionated, dark-adapted thylakoid membranes of spinach (Spinacia oleracea L.) in the absence and in the presence of 2,6-dichlorphenylindophenol (DCMU). In the absence of DCMU, the TL signal from grana fractions consisted of a homogenous B-band, which originates from recombination of the semi-quinone QB− with the S2 state of the water-splitting complex and reflects active photosystem II (PSII). In the presence of DCMU, the B-band was replaced by the Q-band, which originates from an S2QA− recombination. Margin fractions mainly showed two TL-bands, the B- and C-bands, at approximately 50°C in the absence of DCMU, and Q- and C-bands in the presence of DCMU. The C-band is ascribed to a TyrD+-QA− recombination. In the absence of DCMU, the fractions of stromal lamellae mainly gave rise to a TL emission at 42°C. The intensity of this band was independent of the number of excitation flashes and was shifted to higher temperatures (52°C) after the addition of DCMU. Based on these observations, this band was considered to be a C-band. After photoinhibitory light treatment of uncoupled thylakoid membranes, the TL intensities of the B- and Q-bands decreased, whereas the intensity at 45°C (C-band) slightly increased. It is proposed that the 42 to 52°C band that was observed in marginal and stromal lamellae and in photoinhibited thylakoid membranes reflects inactive PSII centers that are assumed to be equivalent to inactive PSII QB-nonreducing centers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the interaction of proton-conducting ionophores (protonophores) with photosynthetic electron transport has been extensively studied during the past decade, the mode of action of protonophores remained uncertain. For a better understanding of the molecular mechanism of the action of protonophores, the introduction of chemically new types of molecules will be required. In this work, we demonstrate that acridones (9-azaanthracene-10-ones) completely fulfill this requirement. At low concentrations of acridones, the thermoluminescence bands at +20 degrees C and +10 degrees C were strongly inhibited, while normal electron transport activity was retained. This indicates that the concentrations of S2 and S3 states involved in the generation of these bands are reduced. At higher concentrations, an increased activity of electron transport was observed, which is attributed to the typical uncoupler effect of protonophores. Indeed, acridones accelerate the decay of the electrochromic absorbance change at 515 nm and also inhibit the generation of the transmembrane proton gradient, measured as an absorbance transient of neutral red. Variable fluorescence induction was quenched even at low concentrations of acridones but was restored by either a long-term illumination or high light intensity. Acridones, similarly to other protonophores, promoted the autooxidation of the high-potential form of cytochrome b559 and partially converted it to lower potential forms. These results suggest that acridones, acting as typical protonophores, uncouple electron transport, accelerate the deactivation of the S2 and S3 states on the donor side, and facilitate the oxidation of cytochrome b559 on the acceptor side of photosystem II.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Desde o seu desenvolvimento na década de 1970 a tomografia computadorizada (TC) passou por grandes mudanças tecnológicas, tornando-se uma importante ferramenta diagnóstica para a medicina. Consequentemente o papel da TC em diagnóstico por imagem expandiu-se rapidamente, principalmente devido a melhorias na qualidade da imagem e tempo de aquisição. A dose de radiação recebida por pacientes devido a tais procedimentos vem ganhando atenção, levando a comunidade científica e os fabricantes a trabalharem juntos em direção a determinação e otimização de doses. Nas últimas décadas muitas metodologias para dosimetria em pacientes têm sido propostas, baseadas especialmente em cálculos utilizando a técnica Monte Carlo ou medições experimentais com objetos simuladores e dosímetros. A possibilidade de medições in vivo também está sendo investigada. Atualmente as principais técnicas para a otimização da dose incluem redução e/ou modulação da corrente anódica. O presente trabalho propõe uma metodologia experimental para estimativa de doses absorvidas pelos pulmões devido a protocolos clínicos de TC, usando um objeto simulador antropomórfico adulto e dosímetros termoluminescentes de Fluoreto de Lítio (LiF). Sete protocolos clínicos diferentes foram selecionados, com base em sua relevância com respeito à otimização de dose e frequência na rotina clínica de dois hospitais de grande porte: Instituto de Radiologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InRad) e Instituto do Câncer do Estado de São Paulo Octávio Frias de Oliveira (ICESP). Quatro protocolos de otimização de dose foram analisados: Auto mA, Auto + Smart mA, Baixa Dose (BD) e Ultra Baixa Dose (UBD). Os dois primeiros protocolos supracitados buscam redução de dose por meio de modulação da corrente anódica, enquanto os protocolos BD e UBD propõem a redução do valor da corrente anódica, mantendo-a constante. Os protocolos BD e UBD proporcionaram redução de dose de 72,7(8) % e 91(1) %, respectivamente; 16,8(1,3) % e 35,0(1,2) % de redução de dose foram obtidas com os protocolos Auto mA e Auto + Smart mA, respectivamente. As estimativas de dose para os protocolos analisados neste estudo são compatíveis com estudos similares publicados na literatura, demonstrando a eficiência da metodologia para o cálculo de doses absorvidas no pulmão. Sua aplicabilidade pode ser estendida a diferentes órgãos, diferentes protocolos de CT e diferentes tipos de objetos simuladores antropomórficos (pediátricos, por exemplo). Por fim, a comparação entre os valores de doses estimadas para os pulmões e valores de estimativas de doses dependentes do tamanho (Size Specific Dose Estimates SSDE) demonstrou dependência linear entre as duas grandezas. Resultados de estudos similares exibiram comportamentos similares para doses no reto, sugerindo que doses absorvidas pelos uma órgãos podem ser linearmente dependente dos valores de SSDE, com coeficientes lineares específicos para cada órgão. Uma investigação mais aprofundada sobre doses em órgãos é necessária para avaliar essa hipótese.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As expectativas da Organização Mundial de Saúde para o ano de 2030 são que o número de mortes por câncer seja de aproximadamente 13,2 milhões, evidenciando a elevada parcela desta doença no problema de saúde mundial. Com relação ao câncer de próstata, de acordo com o Instituto Nacional do Câncer, o número de casos diagnosticados no mundo em 2012 foi de aproximadamente 1,1 milhão, enquanto que no Brasil os dados indicam a incidência de 68 mil novos casos. O tratamento deste tipo de neoplasia pode ser realizado com cirurgia (prostatectomia) ou radioterapia. Dentre a radioterapia, podemos destacar a técnica de braquiterapia, a qual consiste na introdução (implante) de pequenas fontes radioativas (sementes) no interior da próstata, onde será entregue um valor elevado de dose no volume de tratamento e baixa dose nos tecidos ao redor. No Brasil, a classe médica estima uma demanda de aproximadamente 8000 sementes/mês, sendo o custo unitário de cada semente de pelo menos U$ 26,00. A Associação Americana de Físicos na Medicina publicou alguns documentos descrevendo quais parâmetros e análises devem ser realizadas para avaliações da distribuição de dose, como por exemplo, os parâmetros Constante de taxa de dose, Função radial e Função de anisotropia. Estes parâmetros podem ser obtidos através de medidas experimentais da distribuição de dose ou por simulações computacionais. Neste trabalho foram determinados os parâmetros dosimétricos da semente OncoSeed-6711 da empresa Oncura-GEHealthcare e da semente desenvolvida pelo Grupo de Dosimetria de Fontes de Braquiterapia do Centro de Tecnologia das Radiações (CTR IPEN-CNEN/SP) por simulação computacional da distribuição de dose utilizando o código MCNP5, baseado no Método de Monte Carlo. A semente 6711 foi modelada, assim como um sistema dosimétrico constituído por um objeto simulador cúbico de 30x30x30 cm3 preenchido com água. Os valores obtidos da semente 6711 foram comparados com alguns apresentados na literatura, onde o parâmetro Constante de taxa de dose apresentou erro relativo em relação ao valor publicado no TG- 43 de 0,1%, sendo que os outros parâmetros analisados também apresentaram boa concordância com os valores publicados na literatura. Deste modo, pode-se considerar que os parâmetros utilizados nas simulações (espectro, modelagem geométrica e avaliação de resultados) estão compatíveis com outros estudos, sendo estes parâmetros também utilizados nas simulações da semente do IPEN. Considerando as análises de incerteza estatística, os valores obtidos da semente do IPEN são semelhantes aos valores da semente 6711.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O uso de Tomografia Computadorizada (CT) para procedimentos de imagiologia vem crescendo cada vez mais devido aos avanços da tecnologia dos equipamentos de CT, que permitem a obtenção de imagens com melhor resolução do que por outras técnicas, sendo consequentemente responsável pelo aumento da dose de radiação no paciente durante o procedimento. Isso acarretou uma maior preocupação com as doses recebidas pelos pacientes que se submetem a esse tipo de exame. Para a realização da dosimetria de feixes de CT, o instrumento mais utilizado é a câmara de ionização do tipo lápis, pois este dosímetro apresenta uma resposta uniforme ao feixe de radiação incidente em todos os ângulos. A câmara convencional que se encontra disponível no mercado apresenta um comprimento de volume sensível de 10 cm; entretanto, alguns estudos têm mostrado que esse dosímetro tem subestimado os valores de dose. Portanto, neste trabalho optou-se por desenvolver no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI-IPEN/CNEN) duas câmaras de ionização, fazendo uso de materiais nacionais de baixo custo, com comprimentos de volume sensível de 10 cm e 30 cm. A caracterização destas câmaras foi realizada e os resultados se apresentaram dentro dos limites recomendáveis internacionais. Como uma aplicação, as câmaras desenvolvidas, juntamente com uma câmara comercial, foram testadas em um tomógrafo clínico. As câmaras de ionização desenvolvidas foram analisadas de maneira completa, para os seus possíveis usos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o efeito dos tempos de aplicação 3, 4 e 5 minutos por ERA do ultrassom terapêutico (UST) na organização das fibras de colágeno em lesão do tendão do calcâneo de ratos. Foram utilizados quarenta ratos machos Wistar, dos quais 32 sofreram tenotomia total do tendão do calcâneo e foram divididos em 5 grupos: GC, sem tenotomia e tratamento; GT, com tenotomia e sem tratamento; UST3, UST4 e UST5 submetidos à tenotomia e tratados com UST nos tempos de 3, 4 e 5 minutos por área de radiação efetiva respectivamente. Os animais foram submetidos à primeira aplicação do UST foi 24 horas após a cirurgia de tenotomia. A irradiação ultrassônica foi aplicada com os seguintes parâmetros: 1 MHz, modo pulsado com 20% do ciclo de trabalho (2 ms de emissão / 8 ms de intervalo), frequência de 100 Hz, 0,5 W / cm² de intensidade e ERA de 0,5 cm². A aplicação foi realizada 1x/dia. Os animais foram sacrificados após a 10ª sessão de tratamento, no 12º dia pós-operatório. Os tendões foram retirados cirurgicamente para análise da organização das fibras colágenas através do método de birrefringência (retardo óptico - OR). As fibras colágenas mostraram melhor agregação e organização no grupo UST3, UST4 e UST5 quando comparado ao GT (p<0.05) e o UST5 apresentou melhor resposta na comparação intergrupos. Conclui-se que o UST, aplicado no tempo de 5 minutos por área de radiação efetiva, apresentou a melhor dose-resposta quanto à organização das fibras colágenas no reparo tecidual de tendões de ratos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid scan electron paramagnetic resonance (EPR) was developed in the Eaton laboratory at the University of Denver. Applications of rapid scan to wider spectra, such as for immobilized nitroxides, spin-labeled proteins, irradiated tooth and fingernail samples were demonstrated in this dissertation. The scan width has been increased from 55 G to 160 G. The signal to noise (S/N) improvement for slowly tumbling spin-labeled protein samples that is provided by rapid scan EPR will be highly advantageous for biophysical studies. With substantial improvement in S/N by rapid scan, the dose estimation for irradiated tooth enamels became more reliable than the traditional continuous wave (CW) EPR. An alternate approach of rapid scan, called field-stepped direct detection EPR, was developed to reconstruct wider EPR signals. A Mn2+ containing crystal was measured by field-stepped direct detection EPR, which had a spectrum more than 6000 G wide. Since the field-stepped direct detection extends the advantages of rapid scan to much wider scan ranges, this methodology has a great potential to replace the traditional CW EPR. With recent advances in digital electronics, a digital rapid scan spectrometer was built based on an arbitrary waveform generator (AWG), which can excite spins and detect EPR signals with a fully digital system. A near-baseband detection method was used to acquire the in-phase and quadrature signals in one physical channel. The signal was analyzed digitally to generate ideally orthogonal quadrature signals. A multiharmonic algorithm was developed that employed harmonics of the modulation frequencies acquired in the spectrometer transient mode. It was applied for signals with complicated lineshapes, and can simplify the selection of modulation amplitude. A digital saturation recovery system based on an AWG was built at X-band (9.6 GHz). To demonstrate performance of the system, the spin-lattice relaxation time of a fused quartz rod was measured at room temperature with fully digital excitation and detection.