904 resultados para Surgical instruments and apparatus


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis presents new methodology and algorithms that can be used to analyse and measure the hand tremor and fatigue of surgeons while performing surgery. This will assist them in deriving useful information about their fatigue levels, and make them aware of the changes in their tool point accuracies. This thesis proposes that muscular changes of surgeons, which occur through a day of operating, can be monitored using Electromyography (EMG) signals. The multi-channel EMG signals are measured at different muscles in the upper arm of surgeons. The dependence of EMG signals has been examined to test the hypothesis that EMG signals are coupled with and dependent on each other. The results demonstrated that EMG signals collected from different channels while mimicking an operating posture are independent. Consequently, single channel fatigue analysis has been performed. In measuring hand tremor, a new method for determining the maximum tremor amplitude using Principal Component Analysis (PCA) and a new technique to detrend acceleration signals using Empirical Mode Decomposition algorithm were introduced. This tremor determination method is more representative for surgeons and it is suggested as an alternative fatigue measure. This was combined with the complexity analysis method, and applied to surgically captured data to determine if operating has an effect on a surgeon’s fatigue and tremor levels. It was found that surgical tremor and fatigue are developed throughout a day of operating and that this could be determined based solely on their initial values. Finally, several Nonlinear AutoRegressive with eXogenous inputs (NARX) neural networks were evaluated. The results suggest that it is possible to monitor surgeon tremor variations during surgery from their EMG fatigue measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Heavy menstrual bleeding (HMB) is a common problem, yet evidence to inform decisions about initial medical treatment is limited. OBJECTIVES: To assess the clinical effectiveness and cost-effectiveness of the levonorgestrel-releasing intrauterine system (LNG-IUS) (Mirena(®), Bayer) compared with usual medical treatment, with exploration of women's perspectives on treatment. DESIGN: A pragmatic, multicentre randomised trial with an economic evaluation and a longitudinal qualitative study. SETTING: Women who presented in primary care. PARTICIPANTS: A total of 571 women with HMB. A purposeful sample of 27 women who were randomised or ineligible owing to treatment preference participated in semistructured face-to-face interviews around 2 and 12 months after commencing treatment. INTERVENTIONS: LNG-IUS or usual medical treatment (tranexamic acid, mefenamic acid, combined oestrogen-progestogen or progesterone alone). Women could subsequently swap or cease their allocated treatment. OUTCOME MEASURES: The primary outcome was the patient-reported score on the Menorrhagia Multi-Attribute Scale (MMAS) assessed over a 2-year period and then again at 5 years. Secondary outcomes included general quality of life (QoL), sexual activity, surgical intervention and safety. Data were analysed using iterative constant comparison. A state transition model-based cost-utility analysis was undertaken alongside the randomised trial. Quality-adjusted life-years (QALYs) were derived from the European Quality of Life-5 Dimensions (EQ-5D) and the Short Form questionnaire-6 Dimensions (SF-6D). The intention-to-treat analyses were reported as cost per QALY gained. Uncertainty was explored by conducting both deterministic and probabilistic sensitivity analyses. RESULTS: The MMAS total scores improved significantly in both groups at all time points, but were significantly greater for the LNG-IUS than for usual treatment [mean difference over 2 years was 13.4 points, 95% confidence interval (CI) 9.9 to 16.9 points; p < 0.001]. However, this difference between groups was reduced and no longer significant by 5 years (mean difference in scores 3.9 points, 95% CI -0.6 to 8.3 points; p = 0.09). By 5 years, only 47% of women had a LNG-IUS in place and 15% were still taking usual medical treatment. Five-year surgery rates were low, at 20%, and were similar, irrespective of initial treatments. There were no significant differences in serious adverse events between groups. Using the EQ-5D, at 2 years, the relative cost-effectiveness of the LNG-IUS compared with usual medical treatment was £1600 per QALY, which by 5 years was reduced to £114 per QALY. Using the SF-6D, usual medical treatment dominates the LNG-IUS. The qualitative findings show that women's experiences and expectations of medical treatments for HMB vary considerably and change over time. Women had high expectations of a prompt effect from medical treatments. CONCLUSIONS: The LNG-IUS, compared with usual medical therapies, resulted in greater improvement over 2 years in women's assessments of the effect of HMB on their daily routine, including work, social and family life, and psychological and physical well-being. At 5 years, the differences were no longer significant. A similar low proportion of women required surgical intervention in both groups. The LNG-IUS is cost-effective in both the short and medium term, using the method generally recommended by the National Institute for Health and Care Excellence. Using the alternative measures to value QoL will have a considerable impact on cost-effectiveness decisions. It will be important to explore the clinical and health-care trajectories of the ECLIPSE (clinical effectiveness and cost-effectiveness of levonorgestrel-releasing intrauterine system in primary care against standard treatment for menorrhagia) trial participants to 10 years, by which time half of the cohort will have reached menopause. TRIAL REGISTRATION: Current Controlled Trials ISRCTN86566246. FUNDING: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 88. See the NIHR Journals Library website for further project information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Understanding the pharmacological principles and safe use of drugs is just as important in surgical practice as in any other medical specialty. With an ageing population with often multiple comorbidities and medications, as well as an expanding list of new pharmacological treatments, it is important that surgeons understand the implications of therapeutic drugs on their daily practice. The increasing emphasis on high quality and safe patient care demands that doctors are aware of preventable adverse drug reactions (ADRs) and interactions, try to minimize the potential for medication errors, and consider the benefits and harms of medicines in their patients. This chapter examines these aspects from the view of surgical practice and expands on the implications of some of the most common medical conditions and drug classes in the perioperative period. The therapeutic care of surgical patients is obvious in many circumstances – for example, antibacterial prophylaxis, thromboprophylaxis, and postoperative analgesia. However, the careful examination of other drug therapies is often critical not only to the sustained treatment of the associated medical conditions but to the perioperative outcomes of patients undergoing surgery. The benefit–harm balance of many therapies may be fundamentally altered by the stress of an operation in one direction or the other; this is not a decision that should wait until the anaesthetist arrives for a preoperative assessment or one that should be left to junior medical or nursing staff on the ward.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Raster graphic ampelometric software was not exclusively developed for the estimation of leaf area, but also for the characterization of grapevine (Viti vinifera L.) leaves. The software was written in C-Hprogramming language, using the C-1-1- Builder 2007 for Windows 95-XP and Linux operation systems. It handles desktop-scanned images. On the image analysed with the GRA.LE.D., the user has to determine 11 points. These points are then connected and the distances between them calculated. The GRA.LE.D. software supports standard ampelometric measurements such as leaf area, angles between the veins and lengths of the veins. These measurements are recorded by the software and exported into plain ASCII text files for single or multiple samples. Twenty-two biometric data points of each leaf are identified by the GRA.LE.D. It presents the opportunity to statistically analyse experimental data, allows comparison of cultivars and enables graphic reconstruction of leaves using the Microsoft Excel Chart Wizard. The GRA. LE.D. was thoroughly calibrated and compared to other widely used instruments and methods such as photo-gravimetry, LiCor L0100, WinDIAS2.0 and ImageTool. By comparison, the GRA.LE.D. presented the most accurate measurements of leaf area, but the LiCor L0100 and the WinDIAS2.0 were faster, while the photo-gravimetric method proved to be the most time-consuming. The WinDIAS2.0 instrument was the least reliable. The GRA.LE.D. is uncomplicated, user-friendly, accurate, consistent, reliable and has wide practical application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to examine the relationship between the spiritual well-being of nurses and its influence on their attitudes toward providing spiritual care to patients. Two research instruments and a demographic data form were used for the survey. Using a descriptive design, tbe Spiritual Well-Being Scale, the Health Professional's Spiritual Role Scale, and the demographic data form were administered to 100 registered nurses from a large South Florida teaching hospital. The findings indicated a significantly positive correlation between the overall Spiritual Well-Being Scale and the Health Professional's Spiritual Role Scale (r = 0.52; p =.005). Significant differences were found between correlation of nurses' levels of spiritual well-being and all sociodemographic factors except for the three Age Groups and for religious affiliations. Findings have implications for how nurses should be trained in meeting patients total needs. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Today, over 15,000 Ion Mobility Spectrometry (IMS) analyzers are employed at worldwide security checkpoints to detect explosives and illicit drugs. Current portal IMS instruments and other electronic nose technologies detect explosives and drugs by analyzing samples containing the headspace air and loose particles residing on a surface. Canines can outperform these systems at sampling and detecting the low vapor pressure explosives and drugs, such as RDX, PETN, cocaine, and MDMA, because these biological detectors target the volatile signature compounds available in the headspace rather than the non-volatile parent compounds of explosives and drugs.^ In this dissertation research volatile signature compounds available in the headspace over explosive and drug samples were detected using SPME as a headspace sampling tool coupled to an IMS analyzer. A Genetic Algorithm (GA) technique was developed to optimize the operating conditions of a commercial IMS (GE Itemizer 2), leading to the successful detection of plastic explosives (Detasheet, Semtex H, and C-4) and illicit drugs (cocaine, MDMA, and marijuana). Short sampling times (between 10 sec to 5 min) were adequate to extract and preconcentrate sufficient analytes (> 20 ng) representing the volatile signatures in the headspace of a 15 mL glass vial or a quart-sized can containing ≤ 1 g of the bulk explosive or drug.^ Furthermore, a research grade IMS with flexibility for changing operating conditions and physical configurations was designed and fabricated to accommodate future research into different analytes or physical configurations. The design and construction of the FIU-IMS were facilitated by computer modeling and simulation of ion’s behavior within an IMS. The simulation method developed uses SIMION/SDS and was evaluated with experimental data collected using a commercial IMS (PCP Phemto Chem 110). The FIU-IMS instrument has comparable performance to the GE Itemizer 2 (average resolving power of 14, resolution of 3 between two drugs and two explosives, and LODs range from 0.7 to 9 ng). ^ The results from this dissertation further advance the concept of targeting volatile components to presumptively detect the presence of concealed bulk explosives and drugs by SPME-IMS, and the new FIU-IMS provides a flexible platform for future IMS research projects.^