989 resultados para Subcutaneous implantation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Oxidative killing is the primary defense against surgical pathogens; risk of infection is inversely related to tissue oxygenation. Subcutaneous tissue oxygenation in obese patients is significantly less than in lean patients during general anesthesia. However, it remains unknown whether reduced intraoperative tissue oxygenation in obese patients results from obesity per se or from a combination of anesthesia and surgery. In a pilot study, we tested the hypothesis that tissue oxygenation is reduced in spontaneously breathing, unanesthetized obese volunteers. METHODS: Seven lean volunteers with a body mass index (BMI) of 22 +/- 2 kg/m(2) were compared to seven volunteers with a BMI of 46 +/- 4 kg/m(2). Volunteers were subjected to the following oxygen challenges: (1) room air; (2) 2 l/min oxygen via nasal prongs, (3) 6 l/min oxygen through a rebreathing face mask; (4) oxygen as needed to achieve an arterial oxygen pressure (arterial pO(2)) of 200 mmHg; and (5) oxygen as needed to achieve an arterial pO(2) of 300 mmHg. The oxygen challenges were randomized. Arterial pO(2) was measured with a continuous intraarterial blood gas analyzer (Paratrend 7); deltoid subcutaneous tissue oxygenation was measured with a polarographic microoxygen sensor (Licox). RESULTS: Subcutaneous tissue oxygenation was similar in lean and obese volunteers: (1) room air, 52 +/- 10 vs 58 +/- 8 mmHg; (2) 2 l/min, 77 +/- 25 vs 79 +/- 24 mmHg; (3) 6 l/min, 125 +/- 43 vs 121 +/- 25 mmHg; (4) arterial pO(2) = 200 mmHg, 115 +/- 42 vs 144 +/- 23 mmHg; (5) arterial pO(2) = 300 mmHg, 145 +/- 41 vs 154 +/- 32 mmHg. CONCLUSION: In this pilot study, we could not identify significant differences in deltoid subcutaneous tissue oxygen pressure between lean and morbidly obese volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical stress response markedly increases sympathetic nerve activity and catecholamine concentrations. This may contribute to peripheral vasoconstriction, reduced wound perfusion and subsequent tissue hypoxia. Opioids are known to depress the hypothalamic-adrenal response to surgery in a dose-dependent manner. We tested the hypothesis that continuous remifentanil administration produces improved subcutaneous tissue oxygen tension compared to fentanyl bolus administration. Forty-six patients undergoing major abdominal surgery were randomly assigned to receive either fentanyl bolus administration or continuous remifentanil infusion. Mean subcutaneous tissue oxygen values over the entire intra-operative period were significantly higher in the remifentanil group, when compared to the fentanyl group: 8 (2) kPa vs 6.7 (1.5) kPa, % CI difference: - 2.3 kPa to - 0.3 kPa, p = 0.013. Continuous intra-operative opioid administration may blunt vasoconstriction caused by surgical stress and adrenergic responses more than an equi-effective anaesthetic regimen based on smaller-dose bolus opioid administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: We sought to investigate the prevalence of posttraumatic stress disorder, anxiety, and depression in patients and their partners after implantation of a mechanical assist device as a bridge to heart transplantation. METHODS: This was a retrospective assessment of 41 patients (age 46.3 +/- 12.0 years; male-female ratio, 38:3; time since transplantation, 55.3 +/- 34.2 months [range, 7-122 months) and 27 partners (male-female ratio 2:25) by standardized instruments (Impact of Event Scale, Hospital Anxiety and Depression Scale), in 2 University Heart Transplant Centers (Vienna, Austria, Munster, Germany). The duration of the support systems (MicroMed DeBakey-VAD in 17 patients, Novacor in 10, Thoratec in 8, TCI HeartMate in 5, and Berlin Heart Incor in 1 patient) ranged from 28 to 711 (176 +/- 146) days. RESULTS: None of the patients, but 23% of the partners (n = 6), met the criteria for posttraumatic stress disorder (Maercker cutoff >0). The Impact of Event Scale (IES) sum scales differed significantly between the 2 groups (21.2 +/- 15.1, mean +/- SD) for the patients versus 38.1 +/- 27.8 for the partners, respectively; P = .001). Two percent of the patients, but 19% of the partners, showed mild to moderate depression; 4% of patients, but 23% of their partners, reported mild to moderate anxiety. None of the results were significantly influenced by the time since transplantation, patient age, diagnoses, type of assist device, or indication for heart transplantation. CONCLUSIONS: Despite patients being much closer to a life threat, their partners experience significantly more psychologic distress even in the long run. Our findings highlight the need for attention to the supporting persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary aneurysm formation after drug-eluting stent (DES) implantation is a rare complication with late stent thrombosis as a potentially fatal sequela. One possible mechanism involved in aneurysm formation is thought to be late-acquired stent malapposition due to a local inflammatory response to the polymer and/or the drug. Coronary aneurysm formation has been documented with sirolimus- and paclitaxel-eluting stents. We report a case of coronary aneurysm formation in a patient with an everolimus-eluting stent (EES; Xience(R) Abbott Vascular, Redwood City, California) relatively early (3 months) after stent implantation. This case illustrates that even with second-generation DES like the EES, which is thought to be highly biocompatible, there can be adverse reactions to the polymer and/or to the drug.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Recent studies of drug-eluting stents for unprotected left main coronary artery (LMCA) disease have been encouraging. We examined the performance of sirolimus-eluting stents (SES) for this indication. METHODS AND RESULTS: This retrospective study included 228 consecutive patients (mean age = 68 +/- 11 years, 80.6% men, 26.3% diabetics) who underwent implantation of SES for de novo LMCA stenoses. The mean additive and logistic EuroSCOREs were 5.2 +/- 3.9 and 8.2 +/- 13.2, respectively. The main objective of this study was to measure the rate of major adverse cardiac events (MACE), including death, myocardial infarction and target lesion revascularisation (TLR) at 12 months. Other objectives were to measure the rates of in-hospital MACE and 12-month TLR. Outcomes in 143 patients with (BIF+ group), versus 84 patients without (BIF-group) involvement of the bifurcation were compared. The pre-procedural percent diameter stenosis (%DS) was 60.1 +/- 11.2 in the BIF+ versus 54.7 +/- 12.2% in the BIF- group (p=0.008), and decreased to 18.0 +/- 9.7 and 13.9 +/- 11.3%, respectively (ns), after SES implant. The overall in-hospital MACE rate was 3.5%, and similar in both subgroups. The 1-year MACE rate was 14.5% overall, 16.8% in the BIF+ and 10.7% in the BIF- subgroup (ns). CONCLUSIONS: SES implants in high-risk patients with LMCA stenoses were associated with a low 1-year MACE rate. Stenting of the bifurcation was associated with significant increases in neither mortality nor 1-year MACE rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to investigate the long-term safety and efficacy of percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation for unprotected left main coronary artery (ULMCA) disease. BACKGROUND: Long-term clinical outcomes after DES implantation for ULMCA disease have not yet been ascertained. METHODS: From April 2002 to April 2004, 358 consecutive patients who underwent PCI with DES implantation for de novo lesions on ULMCA were retrospectively selected and analyzed in 7 European and U.S. tertiary care centers. No patients were excluded from the analysis, and all patients had a minimum follow-up of 3 years. RESULTS: Technical success rate was 100%. Procedural success rate was 89.6%. After 3 years, major adverse cardiovascular events (MACE)-free survival in the whole population was 73.5%. According to the Academic Research Consortium definitions, cardiac death occurred in 9.2% of patients, and reinfarction, target lesion revascularization (TLR), and target vessel revascularization (TVR) occurred in 8.6%, 5.8%, and 14.2% of patients, respectively. Definite stent thrombosis occurred in 2 patients (specifically at 0 and 439 days). In elective patients, the 3-year MACE-free survival was 74.2%, with mortality, reinfarction, TLR, and TVR rates of 6.2%, 8.3%, 6.6%, and 16%, respectively. In the emergent group the 3-year MACE-free survival was 68.2%, with mortality, reinfarction, TLR, and TVR rates of 21.4%, 10%, 2.8%, and 7.1%, respectively. CONCLUSIONS: Routine DES implantation in ULMCA disease seems encouraging, with favorable long-term clinical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical value of early exercise stress testing (EST) after coronary stenting to predict long-term clinical outcomes is unknown. Of 1,000 unselected patients who underwent coronary stenting, 446 random patients underwent early EST the day after intervention. Clinical long-term outcomes (41 +/- 20 months) were correlated with normal (n = 314 [70%]) or positive (n = 102 [23%]) EST results. Patients with inconclusive test results (n = 30 [7%]) were excluded from the analysis. Overall mortality was significantly higher in patients with positive EST results (9.3% vs 3.9%, p = 0.04). Major adverse cardiac events and cardiac mortality also tended to be higher in patients with positive stress test results (45.4% vs 35.4%, p = 0.08, and 4.1% vs 1.1%, p = 0.05, respectively). Patients with the combination of positive stress test results and incomplete revascularization appeared to be the group at highest risk for major adverse cardiac events (47.1% vs 33.3% for patients with normal stress test results and complete revascularization, p = NS). Negative stress test results reduced (odds ratio 0.329, 95% confidence interval 0.120 to 0.905, p = 0.031) and a lower ejection fraction increased (odds ratio 0.942, 95% confidence interval 0.897 to 0.989, p = 0.017) the risk for death. In conclusion, an early stress test after coronary stenting provides important prognostic information. Positive stress test results, especially in combination with incomplete revascularization, are associated with higher mortality, a trend toward more repeat revascularization procedures, and higher risk for major adverse cardiac events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotational atherectomy has been regaining interest over the last couple of years after it almost has disappeared from most interventional catheterization laboratories for several years due to failure to prove its original concept of improving long term results of percutaneous coronary interventions (PCI) as was repeatedly shown in studies in the 1990s. Its revival coupled the introduction of drug-eluting stents (DES); these devices have led to treating much more complex lesions and high-risk patients by PCI. However, real-world experience suggested that off-label use of DES is associated with a higher rate of early and late stent thrombosis. Therefore, more attention is now being paid to the initial implantation technique of DES including aggressive lesion preparation to facilitate stent delivery and expansion. The limited studies with rot-ablation and DES showed promising results with no long term safety concerns. In these studies, a subtle observation was made suggesting that rot-ablation prior to DES implantation in such lesions may have an add-on effect on long term outcome compared to DES alone. An ongoing multicenter study is investigating such effect among complex calcified coronary lesions. Even if this additive benefit does not prove true, rot-ablation remains an efficient tool for preparing certain lesions to facilitate effective and safe DES implantation. Therefore, interventional training programs should focus on this difficult technique to bridge the gap of experience which resulted from neglecting it for several years. In this regard, dedicated courses at experienced sites as well as medical simulation may be appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: To assess the use of paediatric continuous subcutaneous infusion (CSII) under real-life conditions by analysing data recorded for up to 90 days and relating them to outcome. METHODS: Pump programming data from patients aged 0-18 years treated with CSII in 30 centres from 16 European countries and Israel were recorded during routine clinical visits. HbA(1c) was measured centrally. RESULTS: A total of 1,041 patients (age: 11.8 +/- 4.2 years; diabetes duration: 6.0 +/- 3.6 years; average CSII duration: 2.0 +/- 1.3 years; HbA(1c): 8.0 +/- 1.3% [means +/- SD]) participated. Glycaemic control was better in preschool (n = 142; 7.5 +/- 0.9%) and pre-adolescent (6-11 years, n = 321; 7.7 +/- 1.0%) children than in adolescent patients (12-18 years, n = 578; 8.3 +/- 1.4%). There was a significant negative correlation between HbA(1c) and daily bolus number, but not between HbA(1c) and total daily insulin dose. The use of <6.7 daily boluses was a significant predictor of an HbA(1c) level >7.5%. The incidence of severe hypoglycaemia and ketoacidosis was 6.63 and 6.26 events per 100 patient-years, respectively. CONCLUSIONS/INTERPRETATION: This large paediatric survey of CSII shows that glycaemic targets can be frequently achieved, particularly in young children, and the incidence of acute complications is low. Adequate substitution of basal and prandial insulin is associated with a better HbA(1c).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this work is to develop a magnetic-based passive and wireless pressure sensor for use in biomedical applications. Structurally, the pressure sensor, referred to as the magneto-harmonic pressure sensor, is composed of two magnetic elements: a magnetically-soft material acts as a sensing element, and a magnetically hard material acts as a biasing element. Both elements are embedded within a rigid sensor body and sealed with an elastomer pressure membrane. Upon excitation of an externally applied AC magnetic field, the sensing element is capable of producing higher-order magnetic signature that is able to be remotely detected with an external receiving coil. When exposed to environment with changing ambient pressure, the elastomer pressure membrane of pressure sensor is deflected depending on the surrounding pressure. The deflection of elastomer membrane changes the separation distance between the sensing and biasing elements. As a result, the higher-order harmonic signal emitted by the magnetically-soft sensing element is shifted, allowing detection of pressure change by determining the extent of the harmonic shifting. The passive and wireless nature of the sensor is enabled with an external excitation and receiving system consisting of an excitation coil and a receiving coil. These unique characteristics made the sensor suitable to be used for continuous and long-term pressure monitoring, particularly useful for biomedical applications which often require frequent surveillance. In this work, abdominal aortic aneurysm is selected as the disease model for evaluation the performance of pressure sensor and system. Animal model, with subcutaneous sensor implantation in mice, was conducted to demonstrate the efficacy and feasibility of pressure sensor in biological environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: The goal of this study was to investigate the efficacy of long-term deep brain stimulation (DBS) of the posteroventral lateral globus pallidus internus (GPi) accomplished using a single-contact monopolar electrode in patients with advanced Parkinson disease (PD). METHODS: Sixteen patients suffering from severe PD and levodopa-induced side effects such as dyskinesias and on-off fluctuations were enrolled in a prospective study protocol. There were six women and 10 men and their mean age at surgery was 65 years. All patients underwent implantation of a monopolar electrode in the posteroventral lateral GPi. Initially, nine patients received unilateral stimulation. Three of these patients underwent contralateral surgery at a later time. Ten patients received bilateral stimulation (contemporaneous bilateral surgery was performed in seven patients and staged bilateral surgery in the three patients who had received unilateral stimulation initially). Formal assessments were performed during both off-medication and on-medication (levodopa) periods preoperatively, and at 3 and 12 months postoperatively. There were no serious complications related to surgery or to DBS. Two transient adverse events occurred: in one patient a small pallidal hematoma developed, resulting in a prolonged micropallidotomy effect, and in another patient a subcutaneous hemorrhage occurred at the site of the pacemaker. In patients who received unilateral DBS, the Unified Parkinson's Disease Rating Scale activities of daily living (ADL) score during the off-levodopa period decreased from 30.8 at baseline to 20.4 at 3 months (34% improvement) and 20.6 at 12 months (33% improvement) postoperatively. The motor score during the off period improved from 57.2 at baseline to 35.2 at 3 months (38% improvement) and 35.3 at 12 months (38% improvement) postoperatively. Bilateral DBS resulted in a reduction in the ADL score during the off period from 34.9 at baseline to 22.3 at 3 months (36% improvement) and 22.9 at 12 months (34% improvement). The motor score for the off period changed from 63.4 at baseline to 40.3 at 3 months (36% improvement) and 37.5 at 12 months (41% improvement). In addition, there were significant improvements in patients' symptoms during the on period and in on-off motor fluctuations. CONCLUSIONS: Pallidal DBS accomplished using a monopolar electrode is a safe and effective procedure for treatment of advanced PD. Compared with pallidotomy, the advantages of pallidal DBS lie in its reversibility and the option to perform bilateral surgery in one session. Comparative studies in which DBS is applied to other targets are needed.