733 resultados para Segmented HPGe


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In der vorliegenden Doktorarbeit werden neue, mikrofluidische Verfahren, zur Durchführung chemischer Reaktionen in mehrphasigen Systemen präsentiert. rnDas Einschließen von Reaktionspartnern in einzelne Segmente, deren Volumina im Bereich von Mikro- bis Femtoliter liegen und die dadurch erzeugten enormen, spezifischen Oberflächen, ermöglichen Massentransportprozesse über die Phasengrenzfläche zwischen einzelnen Segmenten, drastisch zu intensivieren. Aufgrund geringer räumlicher Ausdehnungen einzelner Kompartimente und durch vorherrschende, zirkulierende Strömungen in den einzelnen Abschnitten, sind Diffusions- und Konvektionsprozesse in diesen rasch, sodass an der Grenzfläche gebildete, reaktive Intermediate in sehr kurzen Zeitintervallen umgesetzt werden können. rnrn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nell'ambito della terapia medico-nucleare si fa uso di radionuclidi legati a molecole di interesse biologico per poter irradiare le cellule cancerogene di un determinato tessuto, al fine di provocarne l'inattivazione e la morte. Il 223Ra-cloruro è un radiofarmaco di recente introduzione volto al trattamento di metastasi ossee dovute al tumore della prostata. Esso è un emettitore alfa ed è ottenuto tramite un generatore caricato con 227Ac/227Th all'equilibrio. Il radiofarmaco, oltre al breakthrough del progenitore, può contenere anche tracce di 226Ra e 228Th, derivanti dal suo processo produttivo. In questo lavoro di tesi è stato valutato il valore di purezza radionuclidica del 223Ra-cloruro, ricercando la presenza dei suddetti contaminanti, attraverso l'analisi del radiofarmaco mediante uno spettrometro gamma con rivelatore HPGe. Nonostante in uno dei lotti sia stata effettivamente rilevata la presenza del progenitore 227Ac, le misure eseguite hanno comunque confermato l'alto valore di purezza radionuclidica riportato nel Summary of Product Characteristics (SPC) del radiofarmaco. Ciò conferma che non viene somministrata una dose di radiazione ingiustificata al paziente dovuta alla presenza dei contaminanti e semplifica la relativa gestione dei rifiuti radioattivi e le procedure autorizzative.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Negli ultimi anni l'utilizzo di ciclotroni per la produzione di radionuclidi, impiegati nell'ambito della Medicina Nucleare, è diventato un processo sempre più diffuso e numerosi sono i modelli commercialmente disponibili. L'impiego di questo tipo di apparecchiature porta a considerare questioni rilevanti legate alla radioprotezione che coinvolgono una serie di aspetti complessi sia nella fase progettuale del sistema, sia nell'ottenimento delle necessarie autorizzazioni. In particolare, uno dei problemi radioprotezionistici da affrontare è legato alla dispersione in ambiente di aeriformi radioattivi, prodotti dall'interazione di flussi di particelle secondarie con l'aria. In questo lavoro di tesi, svolto presso il Servizio di Fisica Sanitaria dell'Ospedale Sant'Orsola di Bologna, si è cercato di caratterizzare l'emissione di tali gas radioattivi considerando l'effetto del sistema di ventilazione. E' stata eseguita un'estesa campagna di misurazioni in diversi punti di campionamento, collocati lungo il percorso di estrazione dell'aria: dal bunker fino all'immissione in ambiente. Sono stati ideati e realizzati dei compatti sistemi di campionamento che hanno permesso di definire, attraverso un sistema di spettrometria gamma equipaggiato con rivelatore al HPGe, una sistematica procedura per la determinazione di concentrazione di attività. I risultati ottenuti mostrano come, durante la routine di produzione di 18F mediante ciclotrone, il processo più rilevante di attivazione dell'aria sia la produzione di 41Ar (T1/2=109.34 minuti), unico radionuclide identificato in tutte le misurazioni. Infine, sulla base dei dati sperimentali ottenuti, è stata effettuata una valutazione della dose rilasciata alla popolazione locale. Il risultato, pari a 0.19 µSv/anno, può essere considerato trascurabile rispetto alla soglia di "non rilevanza radiologica", a dimostrazione di come le tipiche procedure in ambito di Medicina Nucleare possano essere considerate del tutto giustificate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 μm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanical ventilation is not only a life saving treatment but can also cause negative side effects. One of the main complications is inflammation caused by overstretching of the alveolar tissue. Previously, studies investigated either global strains or looked into which states lead to inflammatory reactions in cell cultures. However, the connection between the global deformation, of a tissue strip or the whole organ, and the strains reaching the single cells lining the alveolar walls is unknown and respective studies are still missing. The main reason for this is most likely the complex, sponge-like alveolar geometry, whose three-dimensional details have been unknown until recently. Utilizing synchrotron-based X-ray tomographic microscopy, we were able to generate real and detailed three-dimensional alveolar geometries on which we have performed finite-element simulations. This allowed us to determine, for the first time, a three-dimensional strain state within the alveolar wall. Briefly, precision-cut lung slices, prepared from isolated rat lungs, were scanned and segmented to provide a three-dimensional geometry. This was then discretized using newly developed tetrahedral elements. The main conclusions of this study are that the local strain in the alveolar wall can reach a multiple of the value of the global strain, for our simulations up to four times as high and that thin structures obviously cause hotspots that are especially at risk of overstretching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current methods to characterize mesenchymal stem cells (MSCs) are limited to CD marker expression, plastic adherence and their ability to differentiate into adipogenic, osteogenic and chondrogenic precursors. It seems evident that stem cells undergoing differentiation should differ in many aspects, such as morphology and possibly also behaviour; however, such a correlation has not yet been exploited for fate prediction of MSCs. Primary human MSCs from bone marrow were expanded and pelleted to form high-density cultures and were then randomly divided into four groups to differentiate into adipogenic, osteogenic chondrogenic and myogenic progenitor cells. The cells were expanded as heterogeneous and tracked with time-lapse microscopy to record cell shape, using phase-contrast microscopy. The cells were segmented using a custom-made image-processing pipeline. Seven morphological features were extracted for each of the segmented cells. Statistical analysis was performed on the seven-dimensional feature vectors, using a tree-like classification method. Differentiation of cells was monitored with key marker genes and histology. Cells in differentiation media were expressing the key genes for each of the three pathways after 21 days, i.e. adipogenic, osteogenic and chondrogenic, which was also confirmed by histological staining. Time-lapse microscopy data were obtained and contained new evidence that two cell shape features, eccentricity and filopodia (= 'fingers') are highly informative to classify myogenic differentiation from all others. However, no robust classifiers could be identified for the other cell differentiation paths. The results suggest that non-invasive automated time-lapse microscopy could potentially be used to predict the stem cell fate of hMSCs for clinical application, based on morphology for earlier time-points. The classification is challenged by cell density, proliferation and possible unknown donor-specific factors, which affect the performance of morphology-based approaches. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intestinal bacteria outnumber our own human cells in conditions of both health and disease. It has long been recognized that secretory antibody, particularly IgA, is produced in response to these microbes and hypothesized that this must play an important role in defining the relationship between a host and its intestinal microbes. However, the exact role of IgA and the mechanisms by which IgA can act are only beginning to be understood. In this review we attempt to unravel the complex interaction between so-called "natural," "primitive" (T-cell-independent), and "classical" IgA responses, the nature of the intestinal microbiota/intestinal pathogens and the highly flexible dynamic homeostasis of the mucosal immune system. Such an analysis reveals that low-affinity IgA is sufficient to protect the host from excess mucosal immune activation induced by harmless commensal microbes. However, affinity-maturation of "classical" IgA is essential to provide protection from more invasive commensal species such as segmented filamentous bacteria and from true pathogens such as Salmonellatyphimurium. Thus a correlation is revealed between "sophistication" of the IgA response and aggressiveness of the challenge. A second emerging theme is that more-invasive species take advantage of host inflammatory mechanisms to more successfully compete with the resident microbiota. In many cases, the function of IgA may be to limit such inflammatory responses, either directly by coagulating or inhibiting virulence of bacteria before they can interact with the host or by modulating immune signaling induced by host recognition. Therefore IgA appears to provide an added layer of robustness in the intestinal ecosystem, promoting "commensal-like" behavior of its residents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among other auditory operations, the analysis of different sound levels received at both ears is fundamental for the localization of a sound source. These so-called interaural level differences, in animals, are coded by excitatory-inhibitory neurons yielding asymmetric hemispheric activity patterns with acoustic stimuli having maximal interaural level differences. In human auditory cortex, the temporal blood oxygen level-dependent (BOLD) response to auditory inputs, as measured by functional magnetic resonance imaging (fMRI), consists of at least two independent components: an initial transient and a subsequent sustained signal, which, on a different time scale, are consistent with electrophysiological human and animal response patterns. However, their specific functional role remains unclear. Animal studies suggest these temporal components being based on different neural networks and having specific roles in representing the external acoustic environment. Here we hypothesized that the transient and sustained response constituents are differentially involved in coding interaural level differences and therefore play different roles in spatial information processing. Healthy subjects underwent monaural and binaural acoustic stimulation and BOLD responses were measured using high signal-to-noise-ratio fMRI. In the anatomically segmented Heschl's gyrus the transient response was bilaterally balanced, independent of the side of stimulation, while in opposite the sustained response was contralateralized. This dissociation suggests a differential role at these two independent temporal response components, with an initial bilateral transient signal subserving rapid sound detection and a subsequent lateralized sustained signal subserving detailed sound characterization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Maternal smoking in pregnancy is associated with respiratory diseases in the offspring, possibly due to prenatal influences on the developing immune system. We investigated whether maternal smoking in pregnancy was associated with cord blood leukocyte numbers, including precursor dendritic cells, adjusting for concomitant factors. In a prospective healthy birth cohort study, total leukocyte counts were reduced in neonates of smoking mothers [10.7 (8.4-13.0), n=14] compared with nonexposed infants [14.7 (13.7-15.7), n=74, p=0.002] [geometric mean cells x 10(3)/microL (95% confidence interval)]. All leukocyte subsets were decreased, most prominently segmented neutrophils [4.3 (2.8-5.7) versus 6.2 (5.5-6.8), p=0.021], lymphocytes [3.8 (2.9-4.8) versus 5.0 (4.5-5.6), p=0.036], and myeloid precursor dendritic cells [12.7 cells/microL (9.1-17.8) versus 18.3 (15.8-21.2), p=0.055]. These differences persisted after adjustment for possible confounders. Predictors of myeloid precursor dendritic cell numbers in multivariable models were maternal smoking (-5.1 cells/microL, p=0.042), age (-0.5 cells/microL/y, p=0.035), and, marginally, asthma (+8.1 cells/microL, p=0.075). The decrease of all leukocytes in neonates of smoking mothers could be clinically significant and suggests a decreased cell production, increased peripheral recruitment, or retention in bone marrow. Given the importance of dendritic cells in early immune responses, their decrease might reflect an impact of maternal smoking on the developing fetal immune system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In this paper, we present a new method for the calibration of a microscope and its registration using an active optical tracker. METHODS: Practically, both operations are done simultaneously by moving an active optical marker within the field of view of the two devices. The IR LEDs composing the marker are first segmented from the microscope images. By knowing their corresponding three-dimensional (3D) position in the optical tracker reference system, it is possible to find the transformation matrix between the referential of the two devices. Registration and calibration parameters can be extracted directly from that transformation. In addition, since the zoom and focus can be modified by the surgeon during the operation, we propose a spline based method to update the camera model to the new setup. RESULTS: The proposed technique is currently being used in an augmented reality system for image-guided surgery in the fields of ear, nose and throat (ENT) and craniomaxillofacial surgeries. CONCLUSIONS: The results have proved to be accurate and the technique is a fast, dynamic and reliable way to calibrate and register the two devices in an OR environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To develop a novel application of a tool for semi-automatic volume segmentation and adapt it for analysis of fetal cardiac cavities and vessels from heart volume datasets. METHODS: We studied retrospectively virtual cardiac volume cycles obtained with spatiotemporal image correlation (STIC) from six fetuses with postnatally confirmed diagnoses: four with normal hearts between 19 and 29 completed gestational weeks, one with d-transposition of the great arteries and one with hypoplastic left heart syndrome. The volumes were analyzed offline using a commercially available segmentation algorithm designed for ovarian folliculometry. Using this software, individual 'cavities' in a static volume are selected and assigned individual colors in cross-sections and in 3D-rendered views, and their dimensions (diameters and volumes) can be calculated. RESULTS: Individual segments of fetal cardiac cavities could be separated, adjacent segments merged and the resulting electronic casts studied in their spatial context. Volume measurements could also be performed. Exemplary images and interactive videoclips showing the segmented digital casts were generated. CONCLUSION: The approach presented here is an important step towards an automated fetal volume echocardiogram. It has the potential both to help in obtaining a correct structural diagnosis, and to generate exemplary visual displays of cardiac anatomy in normal and structurally abnormal cases for consultation and teaching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Direct imaging of extra-solar planets in the visible and infrared region has generated great interest among scientists and the general public as well. However, this is a challenging problem. Diffculties of detecting a planet (faint source) are caused, mostly, by two factors: sidelobes caused by starlight diffraction from the edge of the pupil and the randomly scattered starlight caused by the phase errors from the imperfections in the optical system. While the latter diffculty can be corrected by high density active deformable mirrors with advanced phase sensing and control technology, the optimized strategy for suppressing the diffraction sidelobes is still an open question. In this thesis, I present a new approach to the sidelobe reduction problem: pupil phase apodization. It is based on a discovery that an anti-symmetric spatial phase modulation pattern imposed over a pupil or a relay plane causes diffracted starlight suppression sufficient for imaging of extra-solar planets. Numerical simulations with specific square pupil (side D) phase functions, such as ... demonstrate annulling in at least one quadrant of the diffraction plane to the contrast level of better than 10^12 with an inner working angle down to 3.5L/D (with a = 3 and e = 10^3). Furthermore, our computer experiments show that phase apodization remains effective throughout a broad spectrum (60% of the central wavelength) covering the entire visible light range. In addition to the specific phase functions that can yield deep sidelobe reduction on one quadrant, we also found that a modified Gerchberg-Saxton algorithm can help to find small sized (101 x 101 element) discrete phase functions if regional sidelobe reduction is desired. Our simulation shows that a 101x101 segmented but gapless active mirror can also generate a dark region with Inner Working Distance about 2.8L/D in one quadrant. Phase-only modulation has the additional appeal of potential implementation via active segmented or deformable mirrors, thereby combining compensation of random phase aberrations and diffraction halo removal in a single optical element.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Micro-scale, two-phase flow is found in a variety of devices such as Lab-on-a-chip, bio-chips, micro-heat exchangers, and fuel cells. Knowledge of the fluid behavior near the dynamic gas-liquid interface is required for developing accurate predictive models. Light is distorted near a curved gas-liquid interface preventing accurate measurement of interfacial shape and internal liquid velocities. This research focused on the development of experimental methods designed to isolate and probe dynamic liquid films and measure velocity fields near a moving gas-liquid interface. A high-speed, reflectance, swept-field confocal (RSFC) imaging system was developed for imaging near curved surfaces. Experimental studies of dynamic gas-liquid interface of micro-scale, two-phase flow were conducted in three phases. Dynamic liquid film thicknesses of segmented, two-phase flow were measured using the RSFC and compared to a classic film thickness deposition model. Flow fields near a steadily moving meniscus were measured using RSFC and particle tracking velocimetry. The RSFC provided high speed imaging near the menisci without distortion caused the gas-liquid interface. Finally, interfacial morphology for internal two-phase flow and droplet evaporation were measured using interferograms produced by the RSFC imaging technique. Each technique can be used independently or simultaneously when.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years there has been a personal and organizational trend toward mobility and the use of mobile technologies such as laptops, mobile phones and tablets. With this proliferation of devices, the desire to combine as many functions as possible into one device has also arisen. This concept is commonly called convergence. Generally, device convergence has been segmented between devices for work and devices for home use. Recently, however, the concept of Bring Your Own Device (BYOD) has emerged as organizations attempt to bridge the work/home divide in hopes of increasing employee productivity and reducing corporate technology costs. This paper examines BYOD projects at IBM, Cisco, Citrix, and Intel and then integrates this analysis with current literature to develop and present a BYOD Implementation Success model.