897 resultados para SSTA pattern


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urothelial bladder carcinoma (UBC) is heterogeneous in its pathology and clinical behaviour. Evaluation of prognostic and predictive biomarkers is necessary, in order to produce personalised treatment options. The present study used immunohistochemistry to evaluate UBC sections containing tumour and non-tumour areas from 76 patients, for the detection of p-mTOR, CD31 and D2-40 (blood and lymphatic vessels identification, respectively). Of the non-tumour and tumour sections, 36 and 20% were scored positive for p-mTOR expression, respectively. Immunoexpression was observed in umbrella cells from non-tumour urothelium, in all cell layers from non-muscle-invasive (NMI) tumours (including expression in superficial cells), and in spots of cells from muscle-invasive (MI) tumours. Positive expression decreased from non-tumour to tumour urothelium, and from pTl/pTis to pT3/pT4 tumours; however, the few pT3/pT4 positive cases had worse survival rates, with 5-year disease-free survival being significantly lower. Angiogenesis occurrence was impaired in pT3/pT4 tumours that did not express p-mTOR. In conclusion, p-mTOR expression in non-tumour umbrella cells is likely a reflection of their metabolic plasticity, and extension to the inner layers of the urothelium in NMI tumours is consistent with an enhanced malignant potential. The expression in cell spots in a few MI tumours and absence of expression in the remaining tumours is intriguing and requires further research. Additional studies regarding the up- and downstream effectors of the mTOR pathway should be conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to develop a methodology for seed processing and X-ray analysis and to study imbibition pattern in seeds of candeia (Eremanthus incanus). Seeds were gathered in 2001 and 2002 in Morro do Pilar and Lavras respectively, processed and stored in a cold chamber (5ºC/60%RH) until the start of experiments. In order to identify unfilled seeds, a protocol was developed for X-ray use combining radiation energy (Kv) and exposure time (seconds). For elimination of unfilled seeds, an experiment was conducted using a South Dakota seed blower whereby different opening settings and ventilation times were combined. Original seed lots and categorized lots following radiograph viewing were tested by germination tests, with seeds being cleansed in sodium hypochlorite and scattered over blotting paper in 'gerboxes' and then taken to germinators with alternating temperatures of 20º-30ºC and 10 hours of light, for up to 15 days. Imbibition curves were determined under the conditions 30ºC, 20º-30ºC/10 hours of light and 30º-20ºC/10 hours of light. The X-ray protocol that best allowed viewing of internal seed structures was 30Kv for 45 seconds. Seed separation using the blower setting at a 3.0 opening for 30 seconds raised the number of embryonic seeds to values exceeding 99%, also raising the germination rates as a consequence. The imbibition pattern is three-phased and the germination process is completed in 72 hours. Under alternate temperatures, primary root growth is favored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper establishes the spawning habitat of the Brazilian sardine Sardinella brasiliensis and investigates the spatial variability of egg density and its relation with oceanographic conditions in the shelf of the south-east Brazil Bight (SBB). The spawning habitats of S. brasiliensis have been defined in terms of spatial models of egg density, temperature-salinity plots, quotient (Q) analysis and remote sensing data. Quotient curves (Q(C)) were constructed using the geographic distribution of egg density, temperature and salinity from samples collected during nine survey cruises between 1976 and 1993. The interannual sea surface temperature (SST) variability was determined using principal component analysis on the SST anomalies (SSTA) estimated from remote sensing data over the period between 1985 and 2007. The spatial pattern of egg occurrences in the SBB indicated that the largest concentration occurred between Paranagua and Sao Sebastiao. Spawning habitat expanded and contracted during the years, fluctuating around Paranagua. In January 1978 and January 1993, eggs were found nearly everywhere along the inner shelf of the SBB, while in January 1988 and 1991 spawning had contracted to their southernmost position. The SSTA maps for the spawning periods showed that in the case of habitat expansion (1993 only) anomalies over the SBB were zero or slightly negative, whereas for the contraction period anomalies were all positive. Sardinella brasiliensis is capable of exploring suitable spawning sites provided by the entrainment of the colder and less-saline South Atlantic Central Water onto the shelf by means of both coastal wind-driven (to the north-east of the SBB) and meander-induced (to the south-west of the SBB) upwelling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The State of Sao Paulo is the most developed area in Brazil and was impacted by persistent organic pollutants for several decades. This study investigated organochlorines in five species of small cetaceans (Pontoporia blainvillei, Stenella frontalis, Sotalia guianensis, Tursiops truncatus and Steno bredanensis) found dead along the coast of Sao Paulo between 1997 and 2003. DDTs (15.9 mu g g(-1) lipid: mean for all pooled individuals) and PCBs (8.08 mu g g(-1)) exhibited the highest concentrations in the animals, reflecting large amounts formerly used in Brazil. Lower levels of mirex (0.149 mu g g(-1)), HCB (0.051 mu g g(-1)), CHLs (0.008 mu g g(-1)) and HCHs (0.007 mu g g(-1)) were detected in all species. Residual pattern of DDTs in dolphins suggests that o,p`-DDT is more recalcitrant than p,p`-DDT in the body of the animals and/or the environment. In contrast to p,p`-DDT, residues of o,p`-DDT seem to be preferentially converted into o,p`-DDD rather than op-DDE. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transient visual evoked cortical potentials (VECP) were recorded from the scalp of healthy normal trichromats (n = 12). VECPs were elicited by onset/offset presentation of patterned stimuli of two kinds: isochromatic luminance-modulated, and equiluminant red-green modulated, sine wave gratings. The amplitude and latency of the major onset components of the onset/offset VECP were measured and plotted as a function of the logarithm of pooled cone contrast. The early onset components, achromatic C1 and chromatic N1, increase linearly with log contrast, but N1 has a higher contrast gain than C1. The late onset components, achromatic C2 and chromatic N2, have similar contrast gain, and similar response as a function of contrast level: both increase in the low-to-medium range of contrasts and saturate at high contrast levels. In the range of pooled cone contrast tested, C1 and N1 show similar latencies, whilst C2 shows shorter latencies than N2. We suggest that C1 and N1 are generated by the same visual mechanism with high red-green contrast gain and low luminance contrast gain, whilst C2 and N2 are generated by different visual mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main questions addressed in this work were whether and how adaptation to suppression of visual information occurs in a free-fall paradigm, and the extent to which vision availability influences the control of landing movements. The prelanding modulation of EMG timing and amplitude of four lower-limb muscles was investigated. Participants performed six consecutive drop-landings from four different heights in two experimental conditions: with and without vision. Experimental design precluded participants from estimating the height of the drop. Since cues provided by proprioceptive and vestibular information acquired during the first trials were processed, the nervous system rapidly adapted to the lack of visual information, and hence produced a motor output (i.e., prelanding EMG modulation) similar to that observed when performing the activity with vision available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.