933 resultados para Range-of-motion
Resumo:
The study and understanding of the motion of the fluid phases in a mechanically stirred reactor has always been, and still are, an open problem which absorbs the study and the work of many researchers. In recent decades, thanks to the growing opportunities offered by the development of technology, we have made great strides in the understanding of mixing, one of the major unit operations at the base of many industrial processes. A complete understanding of this process and its optimization for industrial applications is a challenging task due to the complex interactions between the many factors at play that include physical, chemical and biological. The purpose of this thesis is the study of a fluid-mechanically-agitated continuous reactor through the use of optical diagnostic techniques, which allowed to determine the range of motion and the time of perfect homogenization in a reactor of standard geometry in different operating conditions.
Resumo:
Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased total offset and limb shortening. Acetabular offset and height had a greater effect on ROMBI than femoral offset and height. The ROMBI lost with decreased acetabular offset was not fully recoverable with an increase in femoral offset or osteophyte removal. Bony impingement increased and component impingement decreased with decreased acetabular offset and increased head diameter.
Resumo:
Compliant mechanisms with evenly distributed stresses have better load-bearing ability and larger range of motion than mechanisms with compliance and stresses lumped at flexural hinges. In this paper, we present a metric to quantify how uniformly the strain energy of deformation and thus the stresses are distributed throughout the mechanism topology. The resulting metric is used to optimize cross-sections of conceptual compliant topologies leading to designs with maximal stress distribution. This optimization framework is demonstrated for both single-port mechanisms and single-input single-output mechanisms. It is observed that the optimized designs have lower stresses than their nonoptimized counterparts, which implies an ability for single-port mechanisms to store larger strain energy, and single-input single-output mechanisms to perform larger output work before failure.
Resumo:
Femoroacetabular impingement (FAI) is a pathomechanical concept describing the early and painful contact of morphological changes of the hip joint, both on the acetabular, and femoral head sides. These can lead clinically to symptoms of hip and groin pain, and a limited range of motion with labral, chondral and bony lesions. Pincer impingement generally involves the acetabular side of the joint where there is excessive coverage of the acetabulum, which may be focal or more diffuse. There is linear contact of the acetabulum with the head/neck junction. Cam impingement involves the femoral head side of the joint where the head is associated with bony excrescences and is aspheric. The aspheric femoral head jams into the acetabulum. Imaging appearances are reviewed below. This type is evident in young males in the second and third decades. The main features of FAI are described.
Resumo:
Joint-preserving hip surgery, either arthroscopic or open, increasingly is used for the treatment of symptomatic femoroacetabular impingement (FAI). As a consequence of surgery, thickening of the joint capsule and intraarticular adhesions between the labrum and joint capsule and between the femoral neck and the joint capsule have been observed. These alterations are believed to cause persistent pain and reduced range of motion. Because the diagnosis is made with MR arthrography, knowledge of the normal capsular anatomy and thickness on MRI in patients is important. To date there is no such information available.
Resumo:
STUDY DESIGN:: retrospective analysis of prospectively collected clinical data. OBJECTIVE:: To assess the long-term outcome of patients with monosegmental L4/5 degenerative spondylolisthesis treated with the dynamic Dynesys device. SUMMARY OF BACKGROUND DATA:: The Dynesys® system has been used as a semirigid, lumbar dorsal pedicular stabilization device since 1994. Good short-term results have been reported, but little is known about the long-term outcome following treatment for degenerative spondylolisthesis at the L4/5 level. METHODS:: 39 consecutive patients with symptomatic degenerative lumbar spondylolisthesis at the L4/5 level were treated with bilateral decompression and Dynesys instrumentation. At a mean follow-up of 7.2 years (range 5.0-11.2▒y) they underwent clinical and radiographic evaluation and quality of life assessment. RESULTS:: At final follow-up back pain improved in 89% and leg pain improved in 86% of patients compared to preoperative status. 83% of patients reported global subjective improvement. 92% would undergo the surgery again. 8 patients (21%) required further surgery due to symptomatic adjacent segment disease (6 cases), late onset infection (1 case), and screw breakage (1 case). In 9 cases radiological progression of spondylolisthesis at the operated segment was found. 74% of operated segments showed limited flexion-extension range of less than 4°. Adjacent segment pathology, though without clinical correlation, was diagnosed at the L5/S1 (17.9%) and L3/4 (28.2%) segments. In 4 cases asymptomatic screw loosening was observed. CONCLUSION:: Monosegmental Dynesys instrumentation of degenerative spondylolisthesis at L4/5 shows good long-term results. The rate of secondary surgeries is comparable to other dorsal instrumentation devices. Residual range of motion in the stabilized segment is reduced, and the rate of radiological and symptomatic adjacent segment degeneration is low. Patient satisfaction is high. Dynesys stabilization of symptomatic L4/5 degenerative spondylolisthesis is a possible alternative to other stabilization devices.
Resumo:
Despite different operative and non-operative treatment regimens, the outcome after femoral head fractures has changed little over the past decades. The initial trauma itself as well as secondary changes such as posttraumatic osteoarthritis, avascular necrosis or heterotopic ossification is often responsible for severe loss of function of the afflicted hip joint. Anatomic reduction of all fracture fragments seems to be a major influencing factor in determining the outcome quality. Eight years ago we inaugurated a new surgical approach for better access and visualisation for the treatment of femoral head fractures, using the "trochanteric flip" (digastric) osteotomy. Thus inspection of the entire hip joint and accurate fragment reduction under direct visual control are possible. After good initial experiences with this operative procedure we changed our standard treatment regimen to this approach in an attempt to achieve the most accurate anatomic reduction of the femoral head in every affected patient. Between 1998 and 2006 we operated on 12 patients with femoral head fractures associated with posterior hip dislocation, using the new surgical approach. Patients were followed for 2-96 months and outcome was documented with the Merle d'Aubigne and Postel score as well as the Thompson and Epstein score. The posttraumatic formation of heterotopic bone was documented with the Brooker score. Retrospective analysis of these 12 patients showed good or excellent results in 10 patients (83.3%). The two patients with poor outcome developed an avascular necrosis of the femoral head and underwent total hip arthroplasty. Periarticular heterotopic ossification was seen in five patients. In four patients this caused a significantly reduced range of motion and was therefore considered as a posttraumatic complication. The two patients with the most severe heterotopic bone formation (Brooker III and IV) had initially sustained multiple injuries including brain injury. Comparing our results with earlier published series including our own before changing the treatment protocol, the data suggest a favorable outcome in patients with trochanteric flip (digastric) osteotomy for the treatment of femoral head fractures.
Resumo:
BACKGROUND: Valgus hips with increased antetorsion present with lack of external rotation and posterior hip pain that is aggravated with hip extension and external rotation. This may be the result of posterior femoroacetabular impingement (FAI). QUESTIONS/PURPOSES: We asked whether (1) the range of motion (ROM); (2) the location of anterior and posterior bony collision zones; and (3) the prevalence of extraarticular impingement differ between valgus hips with increased antetorsion compared with normal hips and hips with idiopathic FAI. METHODS: Surface models based on CT scan reconstructions of 13 valgus hips with increased antetorsion, 22 hips with FAI, and 27 normal hips were included. Validated three-dimensional collision detection software was used to quantify the simulated hip ROM and the location of impingement on the acetabular and the femoral sides. RESULTS: Hips with coxa valga and antetorsion showed decreased extension, external rotation, and adduction, whereas internal rotation in 90° of flexion was increased. Impingement zones were more anteroinferior on the femur and posteroinferior on the acetabular (pelvic) side; and the zones were more frequently extraarticular, posterior, or to a lesser degree anterior against the inferior iliac spine. We found a higher prevalence of extraarticular impingement for valgus hips with increased antetorsion. CONCLUSIONS: Valgus hips with increased antetorsion predispose to posterior extraarticular FAI and to a lesser degree anteroinferior spine impingement. LEVEL OF EVIDENCE: Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
Resumo:
BACKGROUND Periprosthetic infections remain a devastating problem in the field of joint arthroplasty. In the following study, the results of a two-stage treatment protocol for chronic periprosthetic infections using an intraoperatively molded cement prosthesis-like spacer (CPLS) are presented. METHODS Seventy-five patients with chronically infected knee prosthesis received a two-stage revision procedure with the newly developed CPLS between June 2006 and June 2011. Based on the microorganism involved, patients were grouped into either easy to treat (ETT) or difficult to treat (DTT) and treated accordingly. Range of motion (ROM) and the knee society score (KSS) were utilized for functional assessment. RESULTS Mean duration of the CPLS implant in the DTT group was 3.6 months (range 3-5 months) and in the ETT group 1.3 months (range 0.7-2.5 months). Reinfection rates of the final prosthesis were 9.6% in the ETT and 8.3% in the DTT group with no significant difference between both groups regarding ROM or KSS (P = 0.87, 0.64, resp.). CONCLUSION The results show that ETT patients do not necessitate the same treatment protocol as DTT patients to achieve the same goal, emphasizing the need to differentiate between therapeutic regimes. We also highlight the feasibility of CLPS in two-stage protocols.
Resumo:
Acetabular retroversion following acetabular osteotomy in hips with dysplasia can negatively effect the outcome. Total retroversion, where the entire anterior rim is lateral to the posterior rim, is rare and can easily be missed on pelvic radiographs due to the lack of a crossover sign. We evaluated the clinical and radiographic presentation, the surgical management, and the outcome of hips with total acetabular retroversion. We retrospectively reviewed 26 patients (26 hips) with total retroversion following 15 periacetabular osteotomies (PAO), 10 triple type, and one Salter osteotomy. We obtained range of motion (ROM), anterior impingement test, Drehmann's sign, Merle d’Aubigné-Postel score, and Tönnis score for osteoarthrosis. Corrective surgery included 19 revision PAOs and seven total hip arthroplasties (THA). The mean follow-up was 4.7 ± 4.2 (range 0.5-13.8) years. Patients presented with a restricted ROM (flexion and internal rotation), a positive anterior impingement test, a positive Drehmann's sign, and a decreased Merle d'Aubigné-Postel score due to pain. Corrective surgery was performed after mean of 7 ± 5 (1-15) years. Complications for revision PAO and THA occurred in 37% and 29%, respectively. At follow-up, the Merle d'Aubigné-Postel score improved for both revision PAOs and THAs. The prevalence of a positive anterior impingement test and Drehmann's sign decreased for revision PAOs. There was a tendency for progression of OA in hips with revision PAO. Iatrogenic total acetabular retroversion following reorientation is a disabling condition for the patients. Corrective surgery including revision PAO and THA results in improved clinical outcome. However, these procedures are technically challenging and associated with high complication rates.
Resumo:
The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.
Resumo:
Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.
Resumo:
In this chapter we present our experience with treatment of zone 2 flexor tendon repair using a six-strand repair technique combined with postoperative place-and-hold exercise. The six-strand Lim/Tsai repair technique combined with place-and-hold exercises demonstrated better digital function compared to a two-strand repair without place-and-hold exercises. Range of motion in the Lim/Tsai repair group appeared to be increased without a higher rate of ruptures but with a shorter rehabilitation period. The fact that the two groups differed in both suture techniques and rehabilitation programs made it impossible to know whether the better results in the group of Lim/Tsai were due to the six-strand repair or the place-and-hold exercises or both. Despite the obvious benefit of early active mobilization, an active motion protocol may not always be possible to apply in a substantial number of patients due to concomitant injuries, the quality of the surgical repair or patient factors (swelling, pain, limited compliance). Since August 2006 a staged rehabilitation program (“stop and go”) was introduced within our unit using early active controlled flexion (green), place-and-hold (yellow), or passive flexion exercises (red) introduced by Kleinert-Duran. Our experience using the six-strand suture repair technique and “stop and go” is outlined.
Resumo:
BACKGROUND Severe femoral head deformities in the frontal plane such as hips with Legg-Calvé-Perthes disease (LCPD) are not contained by the acetabulum and result in hinged abduction and impingement. These rare deformities cannot be addressed by resection, which would endanger head vascularity. Femoral head reduction osteotomy allows for reshaping of the femoral head with the goal of improving head sphericity, containment, and hip function. QUESTIONS/PURPOSES Among hips with severe asphericity of the femoral head, does femoral head reduction osteotomy result in (1) improved head sphericity and containment; (2) pain relief and improved hip function; and (3) subsequent reoperations or complications? METHODS Over a 10-year period, we performed femoral head reduction osteotomies in 11 patients (11 hips) with severe head asphericities resulting from LCPD (10 hips) or disturbance of epiphyseal perfusion after conservative treatment of developmental dysplasia (one hip). Five of 11 hips had concomitant acetabular containment surgery including two triple osteotomies, two periacetabular osteotomies (PAOs), and one Colonna procedure. Patients were reviewed at a mean of 5 years (range, 1-10 years), and none was lost to followup. Mean patient age at the time of head reduction osteotomy was 13 years (range, 7-23 years). We obtained the sphericity index (defined as the ratio of the minor to the major axis of the ellipse drawn to best fit the femoral head articular surface on conventional anteroposterior pelvic radiographs) to assess head sphericity. Containment was assessed evaluating the proportion of patients with an intact Shenton's line, the extrusion index, and the lateral center-edge (LCE) angle. Merle d'Aubigné-Postel score and range of motion (flexion, internal/external rotation in 90° of flexion) were assessed to measure pain and function. Complications and reoperations were identified by chart review. RESULTS At latest followup, femoral head sphericity (72%; range, 64%-81% preoperatively versus 85%; range, 73%-96% postoperatively; p = 0.004), extrusion index (47%; range, 25%-60% versus 20%; range, 3%-58%; p = 0.006), and LCE angle (1°; range, -10° to 16° versus 26°; range, 4°-40°; p = 0.0064) were improved compared with preoperatively. With the limited number of hips available, the proportion of an intact Shenton's line (64% versus 100%; p = 0.087) and the overall Merle d'Aubigné-Postel score (14.5; range, 12-16 versus 15.7; range, 12-18; p = 0.072) remained unchanged at latest followup. The Merle d'Aubigné-Postel pain subscore improved (3.5; range, 1-5 versus 5.0; range, 3-6; p = 0.026). Range of motion was not observed to have improved with the numbers available (p ranging from 0.513 to 0.778). In addition to hardware removal in two hips, subsequent surgery was performed in five of 11 hips to improve containment after a mean interval of 2.3 years (range, 0.2-7.5 years). Of those, two hips had triple osteotomy, one hip a combined triple and valgus intertrochanteric osteotomy, one hip an intertrochanteric varus osteotomy, and one hip a PAO with a separate valgus intertrochanteric osteotomy. No avascular necrosis of the femoral head occurred. CONCLUSIONS Femoral head reduction osteotomy can improve femoral head sphericity. Improved head containment in these hips with an often dysplastic acetabulum requires additional acetabular containment surgery, ideally performed concomitantly. This can result in reduced pain and avascular necrosis seems to be rare. With the number of patients available, function did not improve. Therefore, future studies should use more precise instruments to evaluate clinical outcome and include longer followup to confirm joint preservation. LEVEL OF EVIDENCE Level IV, therapeutic study.
Resumo:
Operationsziel Geschlossene, anatomische Reposition und sichere Fixation von problematischen suprakondylären Typ-III- und Typ-IV-Humerusfrakturen, die mit den herkömmlichen Operationsmethoden nur schwierig geschlossen zu behandeln sind. Indikationen Gemäß der AO-Kinderklassifikation der suprakondylären Humerusfrakturen vom Typ III und IV: Frakturen, welche nicht geschlossen mittels üblicher Repositionsmethoden reponierbar sind sowie Frakturen, die nicht mittels der üblichen, gekreuzten perkutanen Kirschner-Draht-Technik zu fixieren sind. Bei schweren Schwellungszuständen, offener Fraktur oder initial neurologischen und/oder vaskulären Problemen („pulseless pink hand“) sowie bei mehrfachverletzten Kindern, welche eine optimale Rehabilitation benötigen und die Extremität gipsfrei sein sollte. Bei Kindern mit Komorbiditäten (z. B. Anfälle, Spastizität), die eine bessere Stabilität benötigen. Kontraindikationen Prinzipiell keine Kontraindikationen Operationstechnik Im nichtreponierten Zustand unter Durchleuchtungskontrolle Einbringen einer einzelnen Schanz-Schraube in den lateralen (radialen) Aspekt des distalen Fragments, welches sich in der streng seitlichen Röntgenprojektion als „Sand-Uhr“- bzw. Kreisform des Capitulum humeri darstellt. Je nach Größe dieses distalen Fragments kann die Schanz-Schraube rein epiphysär oder metaphysär liegen. Danach in absolut streng seitlicher Projektion des distalen Humerus im Bereich des meta-diaphysären Übergangs Einbohren einer 2. Schanz-Schraube unabhängig von der Ersten, die möglichst rechtwinklig zur Längsachse des Humerus in der a.-p.-Ebene zu liegen kommen sollte, um spätere Manipulationen mittels „Joy-Stick“-Technik zu erleichtern. Sind die beiden Schanz-Schrauben mehr oder weniger in beiden Ebenen parallel, so ist die Fraktur praktisch anatomisch reponiert. Nach erreichter Reposition Feinjustierung aller Achskomponenten. Sicherung der Flexion/Extension mittels einem von radial, distal eingebrachten sog. Anti-Rotations-Kirschner-Drahts, der die Stabilität signifikant erhöht und eine Drehung des distalen Fragments um die einzelne Schanz-Schraube verhindert. Postoperative Behandlung Keine zusätzliche Gipsruhigstellung notwendig. Es sollte eine funktionelle Nachbehandlung erfolgen. Ergebnisse Gemäß unserer Langzeitstudien bewegen die meisten Kinder bereits zum Zeitpunkt der ambulanten Pin-Entfernung in der Frakturambulanz ihren Ellbogen weitgehend normal. Bei einer Follow-up-Zeit über 40 Monate hatten 30/31 Kindern eine seitengleiche Achse und Beweglichkeit.