744 resultados para RIBERA, LAZARO DE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last years, intensive animal husbandry production has led to a large concentration of animals in small areas. This has resulted in the production of excessive amounts of manures with insufficient nearby land for application. One of this areas is the Amblés Valley located in the centre of Spain, near to Ávila city, with an extension of 167472 ha of which 88.9% is agricultural land. This valley has an important livestock focused on pig, cattle, chicken production which is associated with the generation of more than 200,000 t/year of manure. There are a number of environmental problems associated with these intensive agricultural systems, including N and P pollution of water bodies, methane emissions and odour pollution. These serious environmental threats are called for innovative environmental management approaches. A feasible technology for the management of manures, offering a potential to valorise these wastes, is pyrolysis, which results in the production of biochar. The objective of this work is evaluated the technical and economic feasibility of the production of biochar in Amblés Valley (Spain).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contiene: Les instructions, e ordinacions perals nouament couertits del regne de Valencia fetes per ... don Iordi de Austria ... e don Antonio Ramirez de Haro ...«a» -- Synodus dioecesana, Valentiae celebrata, praeside ... D. Ioanne Ribera ... anno 1578«a» -- Synodus dioecesana Valentina, celebrata praeside ... D. Ioanne Ribera ... anno 1584,«a» -- Synodus dioecesana Valentina celebrata praeside ... Ioanne Ribera ... anno 1590«a» -- Synodus dioecesana Valentina celebrata die 25 mensis octobris anni 1590 preside ... D. Ioanne Ribera ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El articulo analiza la relación entre la estructura territorial y la formación de nuevos paisajes culturales en la Patagonia chilena como resultado de las explotaciones mineras en la ribera norte del lago General Carrera. El análisis recoge las definiciones y significado del paisaje desarrollado en la tesis doctoral (Marco teórico y Capítulo 2)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ulmus minor es una especie arbórea originaria de Europa cuyas poblaciones han sido diezmadas por el hongo patógeno causante de la enfermedad de la grafiosis. La conservación de los olmos exige plantearse su propagación a través de plantaciones y conocer mejor su ecología y biología. Ulmus minor es un árbol de ribera, pero frecuentemente se encuentra alejado del cauce de arroyos y ríos, donde la capa freática sufre fuertes oscilaciones. Por ello, nuestra hipótesis general es que esta especie es moderadamente resistente tanto a la inundación como a la sequía. El principal objetivo de esta tesis doctoral es entender desde un punto de vista funcional la respuesta de U. minor a la inundación, la sequía y la infección por O. novo-ulmi; los factores que posiblemente más influyen en la distribución actual de U. minor. Con este objetivo se persigue dar continuidad a los esfuerzos de conservación de esta especie que desde hace años se dedican en varios centros de investigación a nivel mundial, ya que, entender mejor los mecanismos que contribuyen a la resistencia de U. minor ante la inoculación con O. novo-ulmi y factores de estrés abiótico ayudará en la selección y propagación de genotipos resistentes a la grafiosis. Se han planteado tres experimentos en este sentido. Primero, se ha comparado la tolerancia de brinzales de U. minor y U. laevis – otro olmo ibérico – a una inmersión controlada con el fin de evaluar su tolerancia a la inundación y comprender los mecanismos de aclimatación. Segundo, se ha comparado la tolerancia de brinzales de U. minor y Quercus ilex – una especie típica de ambientes Mediterránea secos – a la falta de agua en el suelo con el fin de evaluar el grado de tolerancia y los mecanismos de aclimatación a la sequía. El hecho de comparar dos especies contrastadas responde al interés en entender mejor cuales son los procesos que conducen a la muerte de una planta en condiciones de sequía – asunto sobre el que hay una interesante discusión desde hace algunos años. En tercer lugar, con el fin de entender mejor la resistencia de algunos genotipos de U. minor a la grafiosis, se han estudiado las diferencias fisiológicas y químicas constitutivas e inducidas por O. novo-ulmi entre clones de U. minor seleccionados a priori por su variable grado de resistencia a esta enfermedad. En el primer experimento se observó que los brinzales de U. minor sobrevivieron 60 días inmersos en una piscina con agua no estancada hasta una altura de 2-3 cm por encima del cuello de la raíz. A los 60 días, los brinzales de U. laevis se sacaron de la piscina y, a lo largo de las siguientes semanas, fueron capaces de recuperar las funciones fisiológicas que habían sido alteradas anteriormente. La conductividad hidráulica de las raíces y la tasa de asimilación de CO2 neta disminuyeron en ambas especies. Por el contrario, la tasa de respiración de hojas, tallos y raíces aumentó en las primeras semanas de la inundación, posiblemente en relación al aumento de energía necesario para desarrollar mecanismos de aclimatación a la inundación, como la hipertrofia de las lenticelas que se observó en ambas especies. Por ello, el desequilibrio del balance de carbono de la planta podría ser un factor relevante en la mortalidad de las plantas ante inundaciones prolongadas. Las plantas de U. minor (cultivadas en envases de 16 litros a media sombra) sobrevivieron por un prolongado periodo de tiempo en verano sin riego; la mitad de las plantas murieron tras 90 días sin riego. El cierre de los estomas y la pérdida de hojas contribuyeron a ralentizar las pérdidas de agua y tolerar la sequía en U. minor. Las obvias diferencias en tolerancia a la sequía con respecto a Q. ilex se reflejaron en la distinta capacidad para ralentizar la aparición del estrés hídrico tras dejar de regar y para transportar agua en condiciones de elevada tensión en el xilema. Más relevante es que las plantas con evidentes síntomas de decaimiento previo a su muerte exhibieron pérdidas de conductividad hidráulica en las raíces del 80% en ambas especies, mientras que las reservas de carbohidratos apenas variaron y lo hicieron de forma desigual en ambas especies. Árboles de U. minor de 5 y 6 años de edad (plantados en eras con riego mantenido) exhibieron una respuesta a la inoculación con O. novo-ulmi consistente con ensayos previos de resistencia. La conductividad hidráulica del tallo, el potencial hídrico foliar y la tasa de asimilación de CO2 neta disminuyeron significativamente en relación a árboles inoculados con agua, pero solo en los clones susceptibles. Este hecho enlaza con el perfil químico “más defensivo” de los clones resistentes, es decir, con los mayores niveles de suberina, ácidos grasos y compuestos fenólicos en estos clones que en los susceptibles. Ello podría restringir la propagación del hongo en el árbol y preservar el comportamiento fisiológico de los clones resistentes al inocularlos con el patógeno. Los datos indican una respuesta fisiológica común de U. minor a la inundación, la sequía y la infección por O. novo-ulmi: pérdida de conductividad hidráulica, estrés hídrico y pérdida de ganancia neta de carbono. Pese a ello, U. minor desarrolla varios mecanismos que le confieren una capacidad moderada para vivir en suelos temporalmente anegados o secos. Por otro lado, el perfil químico es un factor relevante en la resistencia de ciertos genotipos a la grafiosis. Futuros estudios deberían examinar como este perfil químico y la resistencia a la grafiosis se ven alteradas por el estrés abiótico. ABSTRACT Ulmus minor is a native European elm species whose populations have been decimated by the Dutch elm disease (DED). An active conservation of this species requires large-scale plantations and a better understanding of its biology and ecology. U. minor generally grows close to water channels. However, of the Iberian riparian tree species, U. minor is the one that spread farther away from rivers and streams. For these reasons, we hypothesize that this species is moderately tolerant to both flooding and drought stresses. The main aim of the present PhD thesis is to better understand the functional response of U. minor to the abiotic stresses – flooding and drought – and the biotic stress – DED – that can be most influential on its distribution. The overarching goal is to aid in the conservation of this emblematic species through a better understanding of the mechanisms that contribute to resistance to abiotic and biotic stresses; an information that can help in the selection of resistant genotypes and their expansion in large-scale plantations. To this end, three experiments were set up. First, we compared the tolerance to experimental immersion between seedlings of U. minor and U. laevis – another European riparian elm species – in order to assess their degree of tolerance and understand the mechanisms of acclimation to this stress. Second, we investigated the tolerance to drought of U. minor seedlings in comparison with Quercus ilex (an oak species typical of dry Mediterranean habitats). Besides assessing and understanding U. minor tolerance to drought at the seedling stage, the aim was to shed light into the functional alterations that trigger drought-induced plant mortality – a matter of controversy in the last years. Third, we studied constitutive and induced physiological and biochemical differences among clones of variable DED resistance, before and following inoculation with Ophiostoma novo-ulmi. The goal is to shed light into the factors of DED resistance that is evident in some genotypes of U. minor, but not others. Potted seedlings of U. minor survived for 60 days immersed in a pool with running water to approximately 2-3 cm above the stem collar. By this time, U. minor seedlings died, whereas U. laevis seedlings moved out of the pool were able to recover most physiological functions that had been altered by flooding. For example, root hydraulic conductivity and leaf photosynthetic CO2 uptake decreased in both species; while respiration initially increased with flooding in leaves, stems and roots possibly to respond to energy demands associated to mechanisms of acclimation to soil oxygen deficiency; as example, a remarkable hypertrophy of lenticels was soon observed in flooded seedlings of both species. Therefore, the inability to maintain a positive carbon balance somehow compromises seedling survival under flooding, earlier in U. minor than U. laevis, partly explaining their differential habitats. Potted seedlings of U. minor survived for a remarkable long time without irrigation – half of plants dying only after 90 days of no irrigation in conditions of high vapour pressure deficit typical of summer. Some mechanisms that contributed to tolerate drought were leaf shedding and stomata closure, which reduced water loss and the risk of xylem cavitation. Obviously, U. minor was less tolerant to drought than Q. ilex, differences in drought tolerance resulting mostly from the distinct capacity to postpone water stress and conduct water under high xylem tension among species. More relevant was that plants of both species exhibited similar symptoms of root hydraulic failure (i.e. approximately 80% loss of hydraulic conductivity), but a slight and variable depletion of non-structural carbohydrate reserves preceding dieback. Five- and six-year-old trees of U. minor (planted in the field with supplementary watering) belonging to clones of contrasted susceptibility to DED exhibited a different physiological response to inoculation with O. novo-ulmi. Stem hydraulic conductivity, leaf water potential and photosynthetic CO2 uptake decreased significantly relative to control trees inoculated with water only in DED susceptible clones. This is consistent with the “more defensive” chemical profile observed in resistant clones, i.e. with higher levels of saturated hydrocarbons (suberin and fatty acids) and phenolic compounds than in susceptible clones. These compounds could restrict the spread of O. novo-ulmi and contribute to preserving the near-normal physiological function of resistant trees when exposed to the pathogen. These results evidence common physiological responses of U. minor to flooding, drought and pathogen infection leading to xylem water disruption, leaf water stress and reduced net carbon gain. Still, seedlings of U. minor develop various mechanisms of acclimation to abiotic stresses that can play a role in surviving moderate periods of flood and drought. The chemical profile appears to be an important factor for the resistance of some genotypes of U. minor to DED. How abiotic stresses such as flooding and drought affect the capacity of resistant U. minor clones to face O. novo-ulmi is a key question that must be contemplated in future research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En la presente investigación se analiza la causa del hundimiento del cuarto compartimento del Tercer Depósito del Canal de Isabel II el 8 de abril de 1905, uno de los más graves de la historia de la construcción en España: fallecieron 30 personas y quedaron heridas otras 60. El Proyecto y Construcción de esta estructura era de D. José Eugenio Ribera, una de las grandes figuras de la ingeniería civil en nuestro país, cuya carrera pudo haber quedado truncada como consecuencia del siniestro. Dado el tiempo transcurrido desde la ocurrencia de este accidente, la investigación ha partido de la recopilación de la información relativa al Proyecto y a la propia construcción de la estructura, para revisar a continuación la información disponible sobre el hundimiento. De la construcción de la cubierta es interesante destacar la atrevida configuración estructural, cubriéndose una inmensa superficie de 74.000 m2 mediante una sucesión de bóvedas de hormigón armado de tan sólo 5 cm de espesor y un rebajamiento de 1/10 para salvar una luz de 6 m, que apoyaban en pórticos del mismo material, con pilares también muy esbeltos: 0,25 m de lado para 8 m de altura. Y todo ello en una época en la que la tecnología y conocimiento de las estructuras con este "nuevo" material se basaban en buena medida en el desarrollo de patentes. En cuanto a la información sobre el hundimiento, llama la atención en primer lugar la relevancia de los técnicos, peritos y letrados que intervinieron en el juicio y en el procedimiento administrativo posterior, poniéndose de manifiesto la trascendencia que el accidente tuvo en su momento y que, sin embargo, no ha trascendido hasta nuestros días. Ejemplo de ello es el papel de Echegaray -primera figura intelectual de la época- como perito en la defensa de Ribera, de D. Melquiades Álvarez -futuro presidente del Congreso- como abogado defensor, el General Marvá -uno de los máximos exponentes del papel de los ingenieros militares en la introducción del hormigón armado en nuestro país-, que presidiría la Comisión encargada del peritaje por parte del juzgado, o las opiniones de reconocidas personalidades internacionales del "nuevo" material como el Dr. von Emperger o Hennebique. Pero lo más relevante de dicha información es la falta de uniformidad sobre lo que pudo ocasionar el hundimiento: fallos en los materiales, durante la construcción, defectos en el diseño de la estructura, la realización de unas pruebas de carga cuando se concluyó ésta, etc. Pero la que durante el juicio y en los Informes posteriores se impuso como causa del fallo de la estructura fue su dilatación como consecuencia de las altas temperaturas que se produjeron aquella primavera. Y ello a pesar de que el hundimiento ocurrió a las 7 de la mañana... Con base en esta información se ha analizado el comportamiento estructural de la cubierta, permitiendo evaluar el papel que diversos factores pudieron tener en el inicio del hundimiento y en su extensión a toda la superficie construida, concluyéndose así cuáles fueron las causas del siniestro. De los resultados obtenidos se presta especial atención a las enseñanzas que se desprenden de la ocurrencia del hundimiento, enfatizándose en la relevancia de la historia -y en particular de los casos históricos de error- para la formación continua que debe existir en la Ingeniería. En el caso del hundimiento del Tercer Depósito algunas de estas "enseñanzas" son de plena actualidad, tales como la importancia de los detalles constructivos en la "robustez" de la estructuras, el diseño de estructuras "integrales" o la vigilancia del proceso constructivo. Por último, la investigación ha servido para recuperar, una vez más, la figura de D. José Eugenio Ribera, cuyo papel en la introducción del hormigón armado en España fue decisivo. En la obra del Tercer Depósito se arriesgó demasiado, y provocó un desastre que aceleró la transición hacia una nueva etapa en el hormigón estructural al abrigo de un mayor conocimiento científico y de las primeras normativas. También en esta etapa sería protagonista. This dissertation analyses the cause of the collapse of the 4th compartment of the 3th Reservoir of Canal de Isabel II in Madrid. It happened in 1905, on April 8th, being one of the most disastrous accidents occurred in the history of Spanish construction: 30 people died and 60 were injured. The design and construction supervision were carried out by D. José Eugenio Ribera, one of the main figures in Civil Engineering of our country, whose career could have been destroyed as a result of this accident. Since it occurred more than 100 years ago, the investigation started by compiling information about the structure`s design and construction, followed by reviewing the available information about the accident. With regard to the construction, it is interesting to point out its daring structural configuration. It covered a huge area of 74.000 m2 with a series of reinforced concrete vaults with a thickness of not more than 5 cm, a 6 m span and a rise of 1/10th. In turn, these vaults were supported by frames composed of very slender 0,25 m x 0,25 m columns with a height of 8 m. It is noteworthy that this took place in a time when the technology and knowledge about this "new" material was largely based on patents. In relation to the information about the collapse, its significance is shown by the important experts and lawyers that were involved in the trial and the subsequent administrative procedure. For example, Echegaray -the most important intellectual of that time- defended Ribera, Melquiades Álvarez –the future president of the Congress- was his lawyer, and General Marvá -who represented the important role of the military engineers in the introduction of reinforced concrete in our country-, led the Commission that was put in charge by the judge of the root cause analysis. In addition, the matter caught the interest of renowned foreigners like Dr. von Emperger or Hennebique and their opinions had a great influence. Nonetheless, this structural failure is unknown to most of today’s engineers. However, what is most surprising are the different causes that were claimed to lie at the root of the disaster: material defects, construction flaws, errors in the design, load tests performed after the structure was finished, etc. The final cause that was put forth during the trial and in the following reports was attributed to the dilatation of the roof due to the high temperatures that spring, albeit the collapse occurred at 7 AM... Based on this information the structural behaviour of the roof has been analysed, which allowed identifying the causes that could have provoked the initial failure and those that could have led to the global collapse. Lessons have been learned from these results, which points out the relevance of history -and in particular, of examples gone wrong- for the continuous education that should exist in engineering. In the case of the 3th Reservoir some of these lessons are still relevant during the present time, like the importance of detailing in "robustness", the design of "integral" structures or the due consideration of construction methods. Finally, the investigation has revived, once again, the figure of D. José Eugenio Ribera, whose role in the introduction of reinforced concrete in Spain was crucial. With the construction of the 3th Reservoir he took too much risk and caused a disaster that accelerated the transition to a new era in structural concrete based on greater scientific knowledge and the first codes. In this new period he would also play a major role.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Breve descripcion de las fiestas que hizo el Real Convento de Predicadores de Valencia en la beatificacion del B. Juan de Ribera. Y sermón que predicó ... Luis Ballester, prior del mismo convento. (XVIII/4277).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Breve descripcion de las fiestas que hizo el Real Convento de Predicadores de Valencia en la beatificacion del B. Juan de Ribera. Y sermón que predicó ... Luis Ballester, prior del mismo convento. (XVIII/4277).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Breve descripcion de las fiestas que hizo el Real Convento de Predicadores de Valencia en la beatificacion del B. Juan de Ribera. Y sermón que predicó ... Luis Ballester, prior del mismo convento. (XVIII/4277).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Breve descripcion de las fiestas que hizo el Real Convento de Predicadores de Valencia en la beatificacion del B. Juan de Ribera. Y sermón que predicó ... Luis Ballester, prior del mismo convento. (XVIII/4277).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tesis analiza los criterios con que fueron proyectadas y construidas las estructuras de hormigón hasta 1973, fecha coincidente con la Instrucción EH-73, que en contenido, formato y planteamiento, consagró la utilización de los criterios modernamente utilizados hasta ahora. Es heredera, además, de las CEB 1970. Esos años marcan el cambio de planteamiento desde la Teoría Clásica hacia los Estados Límite. Los objetivos perseguidos son, sintéticamente: 1) Cubrir un vacío patente en el estudio de la evolución del conocimiento. Hay tratados sobre la historia del hormigón que cubren de manera muy completa el relato de personajes y realizaciones, pero no, al menos de manera suficiente, la evolución del conocimiento. 2) Servir de ayuda a los técnicos de hoy para entender configuraciones estructurales, geometrías, disposiciones de armado, formatos de seguridad, etc, utilizados en el pasado, lo que servirá para la redacción más fundada de dictámenes preliminares sobre estructuras existentes. 3) Ser referencia para la realización de estudios de valoración de la capacidad resistente de construcciones existentes, constituyendo la base de un documento pre-normativo orientado en esa dirección. En efecto, esta tesis pretende ser una ayuda para los ingenieros de hoy que se enfrentan a la necesidad de conservar y reparar estructuras de hormigón armado que forman parte del patrimonio heredado. La gran mayoría de las estructuras, fueron construidas hace más de 40 años, por lo que es preciso conocer los criterios que marcaron su diseño, su cálculo y su construcción. Pretende determinar cuáles eran los límites de agotamiento y por tanto de seguridad, de estructuras dimensionadas con criterios de antaño, analizadas por la metodología de cálculo actual. De este modo, se podrá determinar el resguardo existente “real” de las estructuras dimensionadas y calculadas con criterios “distintos” a los actuales. Conocer el comportamiento de las estructuras construidas con criterios de la Teoría Clásica, según los criterios actuales, permitirá al ingeniero de hoy tratar de la forma más adecuada el abanico de necesidades que se puedan presentar en una estructura existente. Este trabajo se centra en la evolución del conocimiento por lo que no se encuentran incluidos los procesos constructivos. En lo relativo a los criterios de proyecto, hasta mediados del siglo XX, éstos se veían muy influidos por los ensayos y trabajos de autor consiguientes, en los que se basaban los reglamentos de algunos países. Era el caso del reglamento prusiano de 1904, de la Orden Circular francesa de 1906, del Congreso de Lieja de 1930. A partir de la segunda mitad del siglo XX, destacan las aportaciones de ingenieros españoles como es el caso de Alfredo Páez Balaca, Eduardo Torroja y Pedro Jiménez Montoya, entre otros, que permitieron el avance de los criterios de cálculo y de seguridad de las estructuras de hormigón, hasta los que se conocen hoy. El criterio rector del proyecto de las estructuras de hormigón se fundó, como es sabido, en los postulados de la Teoría Clásica, en particular en el “momento crítico”, aquel para el que hormigón y acero alcanzan sus tensiones admisibles y, por tanto, asegura el máximo aprovechamiento de los materiales y sin pretenderlo conscientemente, la máxima ductilidad. Si el momento solicitante es mayor que el crítico, se dispone de armadura en compresión. Tras el estudio de muchas de las estructuras existentes de la época por el autor de esta tesis, incluyendo entre ellas las Colecciones Oficiales de Puentes de Juan Manuel de Zafra, Eugenio Ribera y Carlos Fernández Casado, se concluye que la definición geométrica de las mismas no se corresponde exactamente con la resultante del momento crítico, dado que como ahora resultaba necesario armonizar los criterios de armado a nivel sección con la organización de la ferralla a lo largo de los diferentes elementos estructurales. Los parámetros de cálculo, resistencias de los materiales y formatos de seguridad, fueron evolucionando con los años. Se fueron conociendo mejor las prestaciones de los materiales, se fue enriqueciendo la experiencia de los propios procesos constructivos y, en menor medida, de las acciones solicitantes y, consiguientemente, acotándose las incertidumbres asociadas lo cual permitió ir ajustando los coeficientes de seguridad a emplear en el cálculo. Por ejemplo, para el hormigón se empleaba un coeficiente de seguridad igual a 4 a finales del siglo XIX, que evolucionó a 3,57 tras la publicación de la Orden Circular francesa de 1906, y a 3, tras la Instrucción española de 1939. En el caso del acero, al ser un material bastante más conocido por cuanto se había utilizado muchísimo previamente, el coeficiente de seguridad permaneció casi constante a lo largo de los años, con un valor igual a 2. Otra de las causas de la evolución de los parámetros de cálculo fue el mejor conocimiento del comportamiento de las estructuras merced a la vasta tarea de planificación y ejecución de ensayos, con los estudios teóricos consiguientes, realizados por numerosos autores, principalmente austríacos y alemanes, pero también norteamericanos y franceses. En cuanto a los criterios de cálculo, puede sorprender al técnico de hoy el conocimiento que tenían del comportamiento del hormigón desde los primeros años del empleo del mismo. Sabían del comportamiento no lineal del hormigón, pero limitaban su trabajo a un rango de tensióndeformación lineal porque eso aseguraba una previsión del comportamiento estructural conforme a las hipótesis de la Elasticidad Lineal y de la Resistencia de Materiales, muy bien conocidas a principios del s. XX (no así sucedía con la teoría de la Plasticidad, aún sin formular, aunque estaba implícita en los planteamientos algunos ingenieros especializados en estructuras de fábrica (piedra o ladrillo) y metálicas. Además, eso permitía independizar un tanto el proyecto de los valores de las resistencias reales de los materiales, lo que liberaba de la necesidad de llevar a cabo ensayos que, en la práctica, apenas se podían hacer debido a la escasez de los laboratorios. Tampoco disponían de programas informáticos ni de ninguna de las facilidades de las que hoy se tienen, que les permitiera hacer trabajar al hormigón en un rango no lineal. Así, sabia y prudentemente, limitaban las tensiones y deformaciones del material a un rango conocido. El modus operandi seguido para la elaboración de esta tesis, ha sido el siguiente: -Estudio documental: se han estudiado documentos de autor, recomendaciones y normativa generada en este ámbito, tanto en España como con carácter internacional, de manera sistemática con arreglo al índice del documento. En este proceso, se han detectado lagunas del conocimiento (y su afección a la seguridad estructural, en su caso) y se han identificado las diferencias con los procedimientos de hoy. También ha sido necesario adaptar la notación y terminología de la época a los criterios actuales, lo que ha supuesto una dificultad añadida. -Desarrollo del documento: A partir del estudio previo se han ido desarrollando los siguientes documentos, que conforman el contenido de la tesis: o Personajes e instituciones relevantes por sus aportaciones al conocimiento de las estructuras de hormigón (investigación, normativa, docencia). o Caracterización de las propiedades mecánicas de los materiales (hormigón y armaduras), en relación a sus resistencias, diagramas tensión-deformación, módulos de deformación, diagramas momento-curvatura, etc. Se incluye aquí la caracterización clásica de los hormigones, la geometría y naturaleza de las armaduras, etc. o Formatos de seguridad: Se trata de un complejo capítulo del que se pretende extraer la información suficiente que permita a los técnicos de hoy entender los criterios utilizados entonces y compararlos con los actuales. o Estudio de secciones y piezas sometidas a tensiones normales y tangenciales: Se trata de presentar la evolución en el tratamiento de la flexión simple y compuesta, del cortante, del rasante, torsión, etc. Se tratan también en esta parte del estudio aspectos que, no siendo de preocupación directa de los técnicos de antaño (fisuración y deformaciones), tienen hoy mayor importancia frente a cambios de usos y condiciones de durabilidad. o Detalles de armado: Incluye el tratamiento de la adherencia, el anclaje, el solapo de barras, el corte de barras, las disposiciones de armado en función de la geometría de las piezas y sus solicitaciones, etc. Es un capítulo de importancia obvia para los técnicos de hoy. Se incluye un anejo con las referencias más significativas a los estudios experimentales en que se basaron las propuestas que han marcado hito en la evolución del conocimiento. Finalmente, junto a las conclusiones más importantes, se enuncian las propuestas de estudios futuros. This thesis analyzes the criteria with which structures of reinforced concrete have been designed and constructed prior to 1973. Initially, the year 1970 was chosen as starting point, coinciding with the CEB recommendations, but with the development of the thesis it was decided that 1973 was the better option, coinciding with the Spanish regulations of 1973, whose content, format and description introduced the current criteria. The studied period includes the Classic Theory. The intended goals of this thesis are: 1) To cover a clear gap in the study of evolution of knowledge about reinforced concrete. The concept and accomplishments achieved by reinforced concrete itself has been treated in a very complete way by the main researchers in this area, but not the evolution of knowledge in this subject area. 2) To help the engineers understand structural configurations, geometries, dispositions of steel, safety formats etc, that will serve as preliminary judgments by experts on existing structures. To be a reference to the existing studies about the valuation of resistant capacity of existing constructions, constituting a basic study of a pre-regulation document. This thesis intends to be a help for the current generation of engineers who need to preserve and repair reinforced concrete structures that have existed for a significant number of years. Most of these structures in question were constructed more than 40 years ago, and it is necessary to know the criteria that influenced their design, the calculation and the construction. This thesis intends to determine the safety limits of the old structures and analyze them in the context of the current regulations and their methodology. Thus, it will then be possible to determine the safety of these structures, after being measured and calculated with the current criteria. This will allow the engineers to optimize the treatment of such a structure. This work considers the evolution of the knowledge, so constructive methods are not included. Related to the design criteria, there existed until middle of the 20th century a large number of diverse European tests and regulations, such as the Prussian norm of 1904, the Circular French Order of 1906, the Congress of Liège of 1930, as well as individual engineers’ own notes and criteria which incorporated the results of their own tests. From the second half of the 20th century, the contributions of Spanish engineers as Alfredo Páez Balaca, Eduardo Torroja and Pedro Jiménez Montoya, among others, were significant and this allowed the advancement of the criteria of the calculation of safety standards of concrete structures, many of which still exist to the present day. The design and calculation of reinforced concrete structures by the Classic Theory, was based on the ‘Critical Bending Moment’, when concrete and steel achieve their admissible tensions, that allows the best employment of materials and the best ductility. If the bending moment is major than the critical bending moment, will be necessary to introduce compression steel. After the study of the designs of many existing structures of that time by the author of this thesis, including the Historical Collections of Juan Manuel de Zafra, Eugenio Ribera and Carlos Fernandez Casado, the conclusion is that the geometric definition of the structures does not correspond exactly with the critical bending moment inherent in the structures. The parameters of these calculations changed throughout the years. The principal reason that can be outlined is that the materials were improving gradually and the number of calculated uncertainties were decreasing, thus allowing the reduction of the safety coefficients to use in the calculation. For example, concrete used a coefficient of 4 towards the end of the 19th century, which evolved to 3,57 after the publication of the Circular French Order of 1906, and then to 3 after the Spanish Instruction of 1939. In the case of the steel, a much more consistent material, the safety coefficient remained almost constant throughout the years, with a value of 2. Other reasons related to the evolution of the calculation parameters were that the tests and research undertaken by an ever-increasing number of engineers then allowed a more complete knowledge of the behavior of reinforced concrete. What is surprising is the extent of knowledge that existed about the behavior of the concrete from the outset. Engineers from the early years knew that the behavior of the concrete was non-linear, but they limited the work to a linear tension-deformation range. This was due to the difficulties of work in a non-linear range, because they did not have laboratories to test concrete, or facilities such as computers with appropriate software, something unthinkable today. These were the main reasons engineers of previous generations limited the tensions and deformations of a particular material to a known range. The modus operandi followed for the development of this thesis is the following one: -Document study: engineers’ documents, recommendations and regulations generated in this area, both from Spain or overseas, have been studied in a systematic way in accordance with the index of the document. In this process, a lack of knowledge has been detected concerning structural safety, and differences to current procedures have been identified and noted. Also, it has been necessary to adapt the notation and terminology of the Classic Theory to the current criteria, which has imposed an additional difficulty. -Development of the thesis: starting from the basic study, the next chapters of this thesis have been developed and expounded upon: o People and relevant institutions for their contribution to the knowledge about reinforced concrete structures (investigation, regulation, teaching). Determination of the mechanical properties of the materials (concrete and steel), in relation to their resistances, tension-deformation diagrams, modules of deformation, moment-curvature diagrams, etc. Included are the classic characterizations of concrete, the geometry and nature of the steel, etc. Safety formats: this is a very difficult chapter from which it is intended to provide enough information that will then allow the present day engineer to understand the criteria used in the Classic Theory and then to compare them with the current theories. Study of sections and pieces subjected to normal and tangential tensions: it intends to demonstrate the evolution in the treatment of the simple and complex flexion, shear, etc. Other aspects examined include aspects that were not very important in the Classic Theory but currently are, such as deformation and fissures. o Details of reinforcement: it includes the treatment of the adherence, the anchorage, the lapel of bars, the cut of bars, the dispositions of reinforcement depending on the geometry of the pieces and the solicitations, etc. It is a chapter of obvious importance for current engineers. The document will include an annex with the most references to the most significant experimental studies on which were based the proposals that have become a milestone in the evolution of knowledge in this area. Finally, there will be included conclusions and suggestions of future studies. A deep study of the documentation and researchers of that time has been done, juxtaposing their criteria and results with those considered relevant today, and giving a comparison between the resultant safety standards according to the Classic Theory criteria and currently used criteria. This thesis fundamentally intends to be a guide for engineers who have to treat or repair a structure constructed according to the Classic Theory criteria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Relacion de la entrada que hizieron en la ciudad de Denia, Reyno de Valencia, las armas de la Magestad Catolica, del Rey nuestro Señor Carlos IIJ [sic] ... el dia 18 de agosto de 1705. (XVIII/1688).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Romans, y coloqui nou, pera divertir el humor y desterrar la melancolia, yà que no tenim dinès ... (NP849.91/3085).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Individual noticia de todos los altares, arcos pinturas, adornos y lo mas exquisito y notable que havia en la carrera de la procession, y de las iluminaciones en general ... : (XVIII/1705).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hay un ejemplar encuadernado con: Individual noticia de todos los altares, arcos pinturas, adornos y lo mas exquisito y notable que havia en la carrera de la procession, y de las iluminaciones en general ... : (XVIII/1705).