948 resultados para REPRODUCIBILITY OF RESULTS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Patient-specific quality of life indices show great potential, but certain conceptual and methodological concerns have yet to be fully addressed. The present study reviewed nine patient-specific instruments used in musculoskeletal disorders: the Canadian Occupational Performance Measure (COPM), Juvenile Arthritis Quality of life Questionnaire (JAQQ), McMaster-Toronto Arthritis questionnaire (MACTAR), Measure Yourself Medical Outcome Profile (MYMOP), Patient-Specific Index (PASI) for total hip arthroplasty, Problem Elicitation Technique (PET), Patient Generated Index (PGI) of quality of life, Patient-Specific Functional Scale (PSFS), and Schedule for the Evaluation of Individual Quality of Life (SEIQoL). STUDY DESIGN AND SETTING: Each tool was evaluated for purpose, content validity, face validity, feasibility, psychometric properties, and responsiveness. RESULTS: This critical appraisal revealed important differences in terms of the concept underlying these indices, the domains covered, the item-generation techniques and the scoring (response scale, methods) in each scale. The nine indices would generate different responses and likely scores for the same patient, despite the fact that they all include patient-generated items. CONCLUSION: Although the value of these indices in treatment planning and monitoring at an individual level is strong, more studies are needed to improve our understanding of how to interpret the numeric scores of patient-specific indices at both an individual and a group level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new non parametric atlas registration framework, derived from the optical flow model and the active contour theory, applied to automatic subthalamic nucleus (STN) targeting in deep brain stimulation (DBS) surgery. In a previous work, we demonstrated that the STN position can be predicted based on the position of surrounding visible structures, namely the lateral and third ventricles. A STN targeting process can thus be obtained by registering these structures of interest between a brain atlas and the patient image. Here we aim to improve the results of the state of the art targeting methods and at the same time to reduce the computational time. Our simultaneous segmentation and registration model shows mean STN localization errors statistically similar to the most performing registration algorithms tested so far and to the targeting expert's variability. Moreover, the computational time of our registration method is much lower, which is a worthwhile improvement from a clinical point of view.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Images of myocardial strain can be used to diagnose heart disease, plan and monitor treatment, and to learn about cardiac structure and function. Three-dimensional (3D) strain is typically quantified using many magnetic resonance (MR) images obtained in two or three orthogonal planes. Problems with this approach include long scan times, image misregistration, and through-plane motion. This article presents a novel method for calculating cardiac 3D strain using a stack of two or more images acquired in only one orientation. The zHARP pulse sequence encodes in-plane motion using MR tagging and out-of-plane motion using phase encoding, and has been previously shown to be capable of computing 3D displacement within a single image plane. Here, data from two adjacent image planes are combined to yield a 3D strain tensor at each pixel; stacks of zHARP images can be used to derive stacked arrays of 3D strain tensors without imaging multiple orientations and without numerical interpolation. The performance and accuracy of the method is demonstrated in vitro on a phantom and in vivo in four healthy adult human subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared alexithymia and depression ratings for non-hospitalized women meeting DSM-IV criteria for anorexia nervosa (n=32) and bulimia nervosa (n=32) to ratings for healthy women (n=74). Alexithymia was evaluated by the Toronto Alexithymia Scale (TAS-20) and depression by the Hospital Anxiety and Depression Scale (HAD). TAS and HAD scores were significantly higher in anorexic compared to bulimic patients, although these two scales were significantly and positively correlated (r=0.53, P=0.001). After taking depression into account as a confounding variable, rates of alexithymia did not vary according to the type of eating disorder (anorexia or bulimia).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fetal MRI reconstruction aims at finding a high-resolution image given a small set of low-resolution images. It is usually modeled as an inverse problem where the regularization term plays a central role in the reconstruction quality. Literature has considered several regularization terms s.a. Dirichlet/Laplacian energy, Total Variation (TV)- based energies and more recently non-local means. Although TV energies are quite attractive because of their ability in edge preservation, standard explicit steepest gradient techniques have been applied to optimize fetal-based TV energies. The main contribution of this work lies in the introduction of a well-posed TV algorithm from the point of view of convex optimization. Specifically, our proposed TV optimization algorithm or fetal reconstruction is optimal w.r.t. the asymptotic and iterative convergence speeds O(1/n2) and O(1/√ε), while existing techniques are in O(1/n2) and O(1/√ε). We apply our algorithm to (1) clinical newborn data, considered as ground truth, and (2) clinical fetal acquisitions. Our algorithm compares favorably with the literature in terms of speed and accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this study were to develop a computerized method to screen for potentially avoidable hospital readmissions using routinely collected data and a prediction model to adjust rates for case mix. We studied hospital information system data of a random sample of 3,474 inpatients discharged alive in 1997 from a university hospital and medical records of those (1,115) readmitted within 1 year. The gold standard was set on the basis of the hospital data and medical records: all readmissions were classified as foreseen readmissions, unforeseen readmissions for a new affection, or unforeseen readmissions for a previously known affection. The latter category was submitted to a systematic medical record review to identify the main cause of readmission. Potentially avoidable readmissions were defined as a subgroup of unforeseen readmissions for a previously known affection occurring within an appropriate interval, set to maximize the chance of detecting avoidable readmissions. The computerized screening algorithm was strictly based on routine statistics: diagnosis and procedures coding and admission mode. The prediction was based on a Poisson regression model. There were 454 (13.1%) unforeseen readmissions for a previously known affection within 1 year. Fifty-nine readmissions (1.7%) were judged avoidable, most of them occurring within 1 month, which was the interval used to define potentially avoidable readmissions (n = 174, 5.0%). The intra-sample sensitivity and specificity of the screening algorithm both reached approximately 96%. Higher risk for potentially avoidable readmission was associated with previous hospitalizations, high comorbidity index, and long length of stay; lower risk was associated with surgery and delivery. The model offers satisfactory predictive performance and a good medical plausibility. The proposed measure could be used as an indicator of inpatient care outcome. However, the instrument should be validated using other sets of data from various hospitals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite obvious improvements in spectral resolution at high magnetic field, the detection of 13C labeling by 1H-[13C] NMR spectroscopy remains hampered by spectral overlap, such as in the spectral region of 1H resonances bound to C3 of glutamate (Glu) and glutamine (Gln), and C6 of N-acetylaspartate (NAA). The aim of this study was to develop, implement, and apply a novel 1H-[13C] NMR spectroscopic editing scheme, dubbed "selective Resonance suppression by Adiabatic Carbon Editing and Decoupling single-voxel STimulated Echo Acquisition Mode" (RACED-STEAM). The sequence is based on the application of two asymmetric narrow-transition-band adiabatic RF inversion pulses at the resonance frequency of the 13C coupled to the protons that need to be suppressed during the mixing time (TM) period, alternating the inversion band downfield and upfield from the 13C resonance on odd and even scans, respectively, thus suppressing the detection of 1H resonances bound to 13C within the transition band of the inversion pulse. The results demonstrate the efficient suppression of 1H resonances bound to C3 of Glu and Gln, and C4 of Glu, which allows the 1H resonances bound to C6 of NAA and C4 of Gln to be revealed. The measured time course of the resolved labeling into NAA C6 with the new scheme was consistent with the slow turnover of NAA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Late-onset cytomegalovirus (CMV) disease commonly occurs after discontinuation of antiviral prophylaxis. We determined the utility of testing CD8+ T-cell response against CMV as a predictor of late-onset CMV disease after a standard course of antiviral prophylaxis. Transplant patients at high-risk for CMV disease were enrolled. CD8+ T-cell-mediated immunity (CMI) was tested using the QuantiFERON-CMV assay at baseline, 1, 2 and 3 months posttransplant by measurement of interferon-gamma response to whole blood stimulation with a 21-peptide pool. The primary outcome was the ability of CMI testing to predict CMV disease in the first 6 months posttransplant. There were 108 evaluable patients (D+/R+ n = 39; D-/R+ n = 34; D+/R- n = 35) of whom 18 (16.7%) developed symptomatic CMV disease. At the end of prophylaxis, CMI was detectable in 38/108 (35.2%) patients (cutoff 0.1 IU/mL interferon-gamma). CMV disease occurred in 2/38 (5.3%) patients with a detectable interferon-gamma response versus 16/70 (22.9%) patients with a negative response; p = 0.038. In the subgroup of D+/R- patients, CMV disease occurred in 1/10 (10.0%) patients with a detectable interferon-gamma response (cutoff 0.1 IU/mL) versus 10/25 (40.0%) patients with a negative CMI, p = 0.12. Monitoring of CMI may be useful for predicting late-onset CMV disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The atomic force microscope is a convenient tool to probe living samples at the nanometric scale. Among its numerous capabilities, the instrument can be operated as a nano-indenter to gather information about the mechanical properties of the sample. In this operating mode, the deformation of the cantilever is displayed as a function of the indentation depth of the tip into the sample. Fitting this curve with different theoretical models permits us to estimate the Young's modulus of the sample at the indentation spot. We describe what to our knowledge is a new technique to process these curves to distinguish structures of different stiffness buried into the bulk of the sample. The working principle of this new imaging technique has been verified by finite element models and successfully applied to living cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Males of plants with separate sexes are often more prone to attack by herbivores than females. A common explanation for this pattern is that individuals with a greater male function suffer more from herbivory because they grow more quickly, drawing more heavily on resources for growth that might otherwise be allocated to defence. Here, we test this 'faster-sex' hypothesis in a species in which males in fact grow more slowly than hermaphrodites, the wind-pollinated annual herb Mercurialis annua. We expected greater herbivory in the faster-growing hermaphrodites. In contrast, we found that males, the slower sex, were significantly more heavily eaten by snails than hermaphrodites. Our results thus reject the faster-sex hypothesis and point to the importance of a trade-off between defence and reproduction rather than growth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The M-Coffee server is a web server that makes it possible to compute multiple sequence alignments (MSAs) by running several MSA methods and combining their output into one single model. This allows the user to simultaneously run all his methods of choice without having to arbitrarily choose one of them. The MSA is delivered along with a local estimation of its consistency with the individual MSAs it was derived from. The computation of the consensus multiple alignment is carried out using a special mode of the T-Coffee package [Notredame, Higgins and Heringa (T-Coffee: a novel method for fast and accurate multiple sequence alignment. J. Mol. Biol. 2000; 302: 205-217); Wallace, O'Sullivan, Higgins and Notredame (M-Coffee: combining multiple sequence alignment methods with T-Coffee. Nucleic Acids Res. 2006; 34: 1692-1699)] Given a set of sequences (DNA or proteins) in FASTA format, M-Coffee delivers a multiple alignment in the most common formats. M-Coffee is a freeware open source package distributed under a GPL license and it is available either as a standalone package or as a web service from www.tcoffee.org.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contemporary coronary magnetic resonance angiography techniques suffer from signal-to-noise ratio (SNR) constraints. We propose a method to enhance SNR in gradient echo coronary magnetic resonance angiography by using sensitivity encoding (SENSE). While the use of sensitivity encoding to improve SNR seems counterintuitive, it can be exploited by reducing the number of radiofrequency excitations during the acquisition window while lowering the signal readout bandwidth, therefore improving the radiofrequency receive to radiofrequency transmit duty cycle. Under certain conditions, this leads to improved SNR. The use of sensitivity encoding for improved SNR in three-dimensional coronary magnetic resonance angiography is investigated using numerical simulations and an in vitro and an in vivo study. A maximum 55% SNR enhancement for coronary magnetic resonance angiography was found both in vitro and in vivo, which is well consistent with the numerical simulations. This method is most suitable for spoiled gradient echo coronary magnetic resonance angiography in which a high temporal and spatial resolution is required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: The aim of this cross-sectional study was to provide normative data (ordinal scores and timed performances) for gross and fine motor tasks in typically developing children between 3 and 5 years of age using the Zurich Neuromotor Assessment (ZNA). METHOD: Typically developing children (n=101; 48 males, 53 females) between 3 and 5 years of age were enrolled from day-care centres in the greater Zurich area and tested using a modified version of the ZNA; the tests were recorded digitally on video. Intraobserver reliability was assessed on the videos of 20 children by one examiner. Interobserver reliability was assessed by two examiners. Test-retest reliability was performed on an additional 20 children. The modelling approach summarized the data with a linear age effect and an additive term for sex, while incorporating informative missing data in the normative values. Normative data for adaptive motor tasks, pure motor tasks, and static and dynamic balance were calculated with centile curves (for timed performance) and expected ordinal scores (for ordinal scales). RESULTS: Interobserver, intraobserver, and test-retest reliability of tasks were moderate to good. Nearly all tasks showed significant age effects, whereas sex was significant only for stringing beads and hopping on one leg. INTERPRETATION: These results indicate that timed performance and ordinal scales of neuromotor tasks can be reliably measured in preschool children and are characterized by developmental change and high interindividual variability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Transcranial Doppler (TCD) is widely used to monitor the temporal course of vasospasm after subarachnoid hemorrhage (SAH), but its ability to predict clinical deterioration or infarction from delayed cerebral ischemia (DCI) remains controversial. We sought to determine the prognostic utility of serial TCD examination after SAH. METHODS: We analyzed 1877 TCD examinations in 441 aneurysmal SAH patients within 14 days of onset. The highest mean blood flow velocity (mBFV) value in any vessel before DCI onset was recorded. DCI was defined as clinical deterioration or computed tomographic evidence of infarction caused by vasospasm, with adjudication by consensus of the study team. Logistic regression was used to calculate adjusted odds ratios for DCI risk after controlling for other risk factors. RESULTS: DCI occurred in 21% of patients (n = 92). Multivariate predictors of DCI included modified Fisher computed tomographic score (P = 0.001), poor clinical grade (P = 0.04), and female sex (P = 0.008). After controlling for these variables, all TCD mBFV thresholds between 120 and 180 cm/s added a modest degree of incremental predictive value for DCI at nearly all time points, with maximal sensitivity by SAH day 8. However, the sensitivity of any mBFV more than 120 cm/s for subsequent DCI was only 63%, with a positive predictive value of 22% among patients with Hunt and Hess grades I to III and 36% in patients with Hunt and Hess grades IV and V. Positive predictive value was only slightly higher if mBFV exceeded 180 cm/s. CONCLUSION: Increased TCD flow velocities imply only a mild incremental risk of DCI after SAH, with maximal sensitivity by day 8. Nearly 40% of patients with DCI never attained an mBFV more than 120 cm/s during the course of monitoring. Given the poor overall sensitivity of TCD, improved methods for identifying patients at high risk for DCI after SAH are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article we propose a novel method for calculating cardiac 3-D strain. The method requires the acquisition of myocardial short-axis (SA) slices only and produces the 3-D strain tensor at every point within every pair of slices. Three-dimensional displacement is calculated from SA slices using zHARP which is then used for calculating the local displacement gradient and thus the local strain tensor. There are three main advantages of this method. First, the 3-D strain tensor is calculated for every pixel without interpolation; this is unprecedented in cardiac MR imaging. Second, this method is fast, in part because there is no need to acquire long-axis (LA) slices. Third, the method is accurate because the 3-D displacement components are acquired simultaneously and therefore reduces motion artifacts without the need for registration. This article presents the theory of computing 3-D strain from two slices using zHARP, the imaging protocol, and both phantom and in-vivo validation.