903 resultados para Proton beam


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the recent years, the use of proton beams in radiotherapy has been an outstanding progress (SMITH, 2006). Up to now, computed tomography (CT) is a prerequisite for treatment planning in this kind of therapy because it provides the electron density distribution required for calculation of dose and the interval of doses. However, the use of CT images for proton treatment planning ignores fundamental differences in physical interaction processes between photons and protons and is, therefore, potentially inaccurate (SADROZINSKI, 2004). Proton CT (pCT) can in principle directly measure the density distribution needed in a patient for the dose distribution (SCHULTE, et al, 2004). One important problem that should be solved is the implementation of image reconstruction algorithms. In this sense, it is necessary to know how the presence of materials with different density and composition interfere in the energy deposition by ionization and coulomb excitation, during its trajectory. The study was conducted in two stages, was used in both the program SRIM (The Stopping and Range of Ions in Matter) to perform simulations of the interaction of proton beams with pencil beam type. In the first step we used the energies in the range of 100-250 MeV (ZIEGLER, 1999). The targets were set to 50 mm in length for the beam of 100 MeV, due to its interaction with the target, and short-range, and 70 mm for 150, 200 and 250 MeV The target was composed of liquid water and a layer of 6 mm cortical bone (ICRP). It were made 9 simulations varying the position of the heterogeneity of 5 mm. In the second step the energy of 250 MeV was taken out from the simulations, due to its greater energy and less interaction. The targets were diminished to 50 mm thick to standardize the simulations. The layer of bone was divided into two equal parts and both were put in the ends of the target... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contribution of the total dose due to deposition of secondary energy particles caused by nuclear inelastic processes (n, 2H, 3H, 3He and  ) in proton therapy is an opened problem and in discussion. In the calculations of plans implemented for routine treatment, the paid dose is calculated whereas that the proton loses energy by ionization and or coulomb excitement. The contribution of inelastic processes associated with nuclear reactions is not considered, mainly due to the difficulty of processing targets consisting of various materials. In this sense, there are only estimates for pure materials or simple composition (water, for example).This work presents the results of simulations by the Monte Carlo method employing the code MCNPX v2.50 (Monte Carlo N-Particle eXtended) of the contribution to the total dose of secondary particles. The study was implemented in a cylindrical phantom composed by compact bone, for monochromatic beams of protons between 100 and 200 MeV with pencil beam form

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K2HPO4 solutions were measured. The relationship between CT number and K2HPO4 concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results The relationship between K2HPO4 concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypertrophy of the mandibular coronoid process is a rare condition, progressive and of unknown etiology, characterized by the over development of the coronoid process determining their size increased, resulting in progressive and painful limitation of mouth opening. The mandibular hypomobility is a present symptom in several diseases and associates it to a specific cause requires detailed clinical and imaginologic examination. The cone-beam computed tomography has the potential to provide complementary informations above than conventional radiography. It also has the advantage of eliminate overlaps, provide high resolution image, helping not only in diagnosis, but also in planning the surgical procedure. Here we report a case of male patient, who appeared at the clinic for an evaluation of a trismus. He had no pain, only discomfort for progressive limitation of mouth opening. On physical examination, only a limited mouth opening has been found. Although the movements of laterality and protrusión were posible, they were very limited. Cone-beam computed tomography examination was performed, that showed an image compatible with bilateral hypertrophy of the mandibular coronoid process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to tridimensionally evaluate pathological and anatomical areas, in apical surgery planning, presents a number of advantages. Cone beam computed tomography (CBCT) was developed for dental applications. This paper aims to present a literature review on CBCT, highlighting its advantages over both conventional computed tomography (CT) and radiography. Moreover, its clinical applications in apical surgery are discussed. LITERATURE REVIEW AND CONCLUSION: Unlikely CT, CBCT captures a volume of data in a single 360º rotation, providing benefits such as higher accuracy, better resolution, reduced scanning time and reduced radiation dose. In the maxillofacial region, CBCT has been mainly used in the assessment of dento-alveolar pathology and oral traumatology. CBCT provides a better diagnosis and quantitative information on periodontal bone levels than conventional radiography. It has also been used for patients requiring surgical facial reconstruction, orthognathic surgery, dental implants, and more complex tooth extractions. Besides that, it seems to be a significant tool in modern endodontic practice, presenting useful applications in apical surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)