942 resultados para Polycation oxides
Resumo:
Copper, aluminum and iron concentrations were determined in four geochemical fractions of three different basaltic soils from the northwest region of the Parana State, Brazil. The fractions examined were the reducible manganese dioxide and amorphous iron oxide, crystaline iron oxide, organic and residual. Metal concentrations were determined in the extracts by flame atomic absorption spectrophotometry. High Fe concentrations were extracted from the crystalline iron oxide (>20%), as well as the amorphous iron oxide (>12%). Copper was extracted from the amorphous and crystalline iron oxides in the range 5 to 12%, but low concentrations were bound to organic matter. Low concentrations of aluminum were extracted (<8%) from the amorphous and crystaline iron oxides, and organic matter. High concentrations of aluminum were found in the residual fraction.
Resumo:
Particles of porous silica or other solvent resistent inorganic oxides can be functionalized by aliphatic (e.g., C-8 or C-18) or other groups to give stationary phases for use in reversed phase HPLC. The functionalization can be done by bonding of individual groups to the surface of the support particles, by producing an organic polymeric film from pre-polymers, or by adsorbing/immobilizing pre-formed polymers on the surfaces. These three types of functionalization are reviewed.
Resumo:
The study of the reactions of organometallic complexes with the surfaces of inorganic oxides, zeolites and metals constitutes the basis of Surface Organometallic Chemistry (SOMC). The basic rules of organometallic chemistry are often valid when applied to surfaces and well-defined surface organometallic complexes can be obtained. These complexes can be used as heterogeneous catalysts or, by controlled reactions, can be transformed in other species useful for a given catalytic reaction. In some cases, these catalysts exhibit higher activity and/or selectivity than their analogous molecular complexes.
Resumo:
The conversion of glycerol in supercritical water (SCW) was studied at 510-550 °C and a pressure of 350 bars using both a bed of inert and non-porous ZrO2 particles (hydrothermal experiments), and a bed of a 1% Ru/ZrO2 catalyst. Experiments were conducted with a glycerol concentration of 5 wt% in a continuous isothermal fixed-bed reactor at a residence time between 2 and 10 s. Hydrothermolysis of glycerol formed water-soluble products such as acetaldehyde, acetic acid, hydroxyacetone and acrolein, and gases like H2, CO and CO2. The catalyst enhanced the formation of acetic acid, inhibited the formation of acrolein, and promoted gasification of the glycerol decomposition products. Hydrogen and carbon oxides were the main gases produced in the catalytic experiments, with minor amounts of methane and ethylene. Complete glycerol conversion was achieved at a residence time of 8.5 s at 510 °C, and at around 5 s at 550 °C with the 1 wt% Ru/ZrO2 catalyst. The catalyst was not active enough to achieve complete gasification since high yields of primary products like acetic acid and acetaldehyde were still present. Carbon balances were between 80 and 60% in the catalytic experiments, decreasing continuously as the residence time was increased. This was attributed partially to the formation of methanol and acetaldehyde, which were not recovered and analyzed efficiently in our set-up, but also to the formation of carbon deposits. Carbon deposition was not observed on the catalyst particles but on the surface of the inert zirconia particles, especially at high residence time. This was related to the higher concentration of acetic acid and other acidic species in the catalytic experiments, which may polymerize to form tar-like carbon precursors. Because of carbon deposition, hydrogen yields were significantly lower than expected; for instance at 550 °C the hydrogen yield potential was only 50% of the stoichiometric value.
Resumo:
In this thesis, cleaning of ceramic filter plates clogged by iron oxides was studied. Oxalic acid is considered as the most effective cleaning agent for the plates fouled by iron oxides, but when using oxalic acid, sparingly soluble calcium oxalate may be formed and it can blind the filter media. Suitability of another chemical for cleaning the plates clogged by iron oxides was studied in this thesis. The literature part was mostly about the properties of the chemical, about its reactions, industrial uses, safety issues etc. In the experimental part, the efficiency of the chemical for cleaning of the ceramic plates clogged by iron oxides was studied. Two kinds of plates were used in the experiments; the others were clogged by hematite and the others by magnetite. Both soaking and flow-through experiments were done. A suitable concentration, pH and temperature were tried to find in the experiments. Also the effect of ultrasound was studied. The efficiency of the cleaning was examined by measuring the permeability of the plates during the experiments. ICP-OES analysis was performed for determining the amount of dissolved iron in the washing solution. Some experiments were also done with oxalic acid. The results from the oxalic acid experiments were compared to the results from the experiments with the other chemical. In the experiments with the other chemical, the permeability increased more and the amounts of dissolved iron were larger. According to the results from the experiments, the method of application of the washing solutions had an impact on the washing results.
Resumo:
Chromium and potassium-doped iron oxides are widely used as industrial catalysts in the dehydrogenation of ethylbenzene to produce styrene. They have several advantages but deactivate with time, because of the loss of potassium. Also, they are toxic due to chromium compounds. Therefore there is a need for developing alternative non toxic catalysts without potassium. Then, iron and aluminum compounds were prepared by different methods in this work. Different phases were produced depending on the preparation method. Aluminum-doped hematite was more active and selective to styrene than the aluminum ferrite. Aluminum acts both as textural and structural promoter in the catalysts.
Resumo:
Simultaneous oxidation/co-precipitation of an equimolar mixture of La(III) and Co(II) nitrates and La(III) nitrate and Mn(II) chloride afforded a hydroxide gel, which was converted to LaCoO3 and LaMnO3 on calcination at 600 °C. After calcination, the obtained perovskites have been characterised by X-ray diffraction (XRD), X- ray photoelectron spectroscopy (XPS), thermogravimetric analysis (DTA - TGA) and BET specific surface determination. Specific surface areas of perovskites were 12 - 60 m²/g. XRD analysis showed that LaCoO3 and LaMnO3 are simple phase perovskite - type oxides. Traces of LaOCl, in addition to the perovskite were detected in the LaMnO3. The catalytic behavior was examined in the propane and CO oxidation. The LaCoO3 catalyst was more active to CO2 than the LaMnO3 catalyst.
Resumo:
Al2O3 is the most abundantly produced nanomaterial and has been used in diverse fields, including the medical, military and industrial sectors. As there are concerns about the health effects of nanoparticles, it is important to understand how they interact with cells, and specifically with red blood cells. The hemolysis induced by three commercial nano-sized aluminum oxide particles (nanopowder 13 nm, nanopowder <50 nm and nanowire 2-6 nm × 200-400 nm) was compared to aluminum oxide and has been studied on erythrocytes from humans, rats and rabbits, in order to elucidate the mechanism of action and the influence of size and shape on hemolytic behavior. The concentrations inducing 50% hemolysis (HC50) were calculated for each compound studied. The most hemolytic aluminum oxide particles were of nanopowder 13, followed by nanowire and nanopowder 50. The addition of albumin to PBS induced a protective effect on hemolysis in all the nano-forms of Al2O3, but not on Al2O3. The drop in HC50 correlated to a decrease in nanomaterial size, which was induced by a reduction of aggregation Aluminum oxide nanoparticles are less hemolytic than other oxide nanoparticles, and behave differently depending on the size and shape of the nanoparticles. The hemolytic behavior of aluminum oxide nanoparticles differs from that of aluminum oxide.
Resumo:
Passive films formed in bicarbonate solutions on carbon steel, chromium steel and high speed steel have been characterized by XPS. The passive films formed on chromium and high speed steels showed superior protective properties than those formed on carbon steel. It was confirmed by XPS that the steel composition influences the passive film composition. Chromium oxide and hydroxide, as well as molybdenum and tungsten oxides and hydroxides are present in the passive film of chromium steel and high speed steel, respectively, besides iron oxide and hydroxide. The more complex composition of the oxide film on high speed steel explains its electrochemical behaviour and highest corrosion resistance.
Resumo:
Sand samples collected from two sampling sites on Guarapari and Iriri beaches, state of Espírito Santo, Brazil, were studied in an attempt to better describe their chemical and mineralogical compositions and radioactive behaviors. The sands were found to contain about 6 (Guarapari) and 2 dag kg-1 (Iriri) of rare earth and thorium that, if allocated to the monazite-(Ce) structure, lead to the averaged formulae Ce3+0,494Gd3+0,012La3+0,209Nd3+0,177Pr3+0,040Sm3+0,024Th4+0,033 (PO4) and Ce3+0,474La3+0,227Nd3+0,190Pr3+0,044Sm3+0,032Th4+0,024 (PO4). From Mössbauer spectroscopy data, the magnetic fractions of these sands were found to contain stoichiometric hematite (47.4 dag kg-1, from Guarapari, and 25.1 dag kg-1, from Iriri) and magnetite (44.1 and 58.8 dag kg-1). The specific alpha and beta radiation activities were also measured for both samples.
Resumo:
In this work the adsorption features of zeolites (NaY, Beta, Mordenite and ZSM-5) have been combined with the magnetic properties of iron oxides in a composite to produce a magnetic adsorbent. These magnetic composites can be used as adsorbents for contaminants in water and subsequently removed from the medium by a simple magnetic process. The magnetic zeolites were characterized by XRD, magnetization measurements, chemical analyses, N2 adsorption isotherms and Mössbauer spectroscopy. These magnetic adsorbents show remarkable adsorption capacity for metal ion contaminants in water.
Resumo:
Two samples of residues from iron mining plants have been investigated for their retention capacity of As, Cu, Cr, and Pb. The sample with the higher content of iron oxides showed the highest capacity to retain metals. The adsorption affinity series changes from Pb>Cu>Cr~As to As>Pb>Cu>Cr or As>Cu>Cr>Pb, depending on the material and the concentration of the initial solution. In the competitive environment, the Pb adsorption decreases and the As, Cu and Cr adsorption increases. Sequential extraction procedures, carried out after adsorption batch experiments, showed that the most important adsorption process occurs in the oxide fraction and that the major part of the absorbed metal is remobilized from exchangeable and oxide fractions.
Resumo:
Al2O3 is the most abundantly produced nanomaterial and has been used in diverse fields, including the medical, military and industrial sectors. As there are concerns about the health effects of nanoparticles, it is important to understand how they interact with cells, and specifically with red blood cells. The hemolysis induced by three commercial nano-sized aluminum oxide particles (nanopowder 13 nm, nanopowder <50 nm and nanowire 2-6 nm × 200-400 nm) was compared to aluminum oxide and has been studied on erythrocytes from humans, rats and rabbits, in order to elucidate the mechanism of action and the influence of size and shape on hemolytic behavior. The concentrations inducing 50% hemolysis (HC50) were calculated for each compound studied. The most hemolytic aluminum oxide particles were of nanopowder 13, followed by nanowire and nanopowder 50. The addition of albumin to PBS induced a protective effect on hemolysis in all the nano-forms of Al2O3, but not on Al2O3. The drop in HC50 correlated to a decrease in nanomaterial size, which was induced by a reduction of aggregation Aluminum oxide nanoparticles are less hemolytic than other oxide nanoparticles, and behave differently depending on the size and shape of the nanoparticles. The hemolytic behavior of aluminum oxide nanoparticles differs from that of aluminum oxide.
Resumo:
Glyphosate, an enzyme inhibitor herbicide, has been widely used around the world in agriculture. Dr. John Franz from Monsanto Corporation (USA) discovered glyphosate in 1970. It has been showed that glyphosate is strongly adsorbed by inorganic soil components especially aluminium and iron oxides, and the phosphate group is involved in this interaction. The inactivation of glyphosate in soils can last for days or even months depending on soil characteristics. The addition of phosphate from fertilizers can displace glyphosate from the soils and this could be the cause of decreased productivity of some crops.
Resumo:
Euroopan unionin direktiiveissä ja kansallisessa lainsäädännössä on asetettu tavoitteita, velvoitteita ja raja-arvoja ilmanlaadun mittauksille. Ilmanlaatua on seurattava, ilmanlaatumittaukset on tehtävä laadukkaasti sekä luotettavasti ja mittaustuloksista on tiedotettava väestölle. Mittausten epävarmuus on tunnettava ja sen on oltava alle 15 %, jotta epävarmuudelle asetettu kriteeri täyttyy. Tässä työssä perehdyttiin Euroopan unionin ilmastopolitiikkaan ja kansalliseen ilmanlaatua koskevaan lainsäädäntöön, käytiin läpi menetelmiä ja tapoja, joilla ilmanlaadusta tiedotetaan väestölle sekä selvitettiin ilmanlaadun mittausjärjestelmiä koskevia vaatimuksia. Ennen varsinaista mittausepävarmuuden selvittämistä käytiin läpi tutkimuksen kohteena olevan typen oksidien analysaattorin mittausperiaate ja merkittävimmät komponentit. Mittausepävarmuus määritettiin standardia SFS-EN 14211 noudattamalla. Mittausepävarmuuden selvittämiseksi analysaattorille tehtiin erilaisia sen toimintaa kuvaavia testejä Ilmatieteen laitoksen kalibrointilaboratoriossa. Saatujen tuloksien perusteella voitiin laskea analysaattorin mittausepävarmuus, joka tuntiraja-arvopitoisuudessa oli 15,5 % ja vuosiraja-arvopitoisuudessa 10,5 %. Kaikkia testejä ei voitu tehdä standardissa määrätyllä tavalla, joten tuloksiin pitää suhtautua kriittisesti. Tulosten perusteella mittausepävarmuus tuntiraja-arvopitoisuudessa ei aivan täytä direktiivin kriteeriä, mutta vuosiraja-arvopitoisuudessa kriteeri täyttyy (< 15 %).