932 resultados para Pitot tubes.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solar alternative system for water heating is presented. It work on a thermosiphon, consisting of one or two alternative collectors and a water storage tank also alternative, whose main purpose is to socialize the use of energy mainly to be used by people of low income. The collectors were built from the use of pets bottles, cans of beer and soft drinks and tubes of PVC, ½ " and the thermal reservoirs from a drum of polyethylene used for storage of water and garbage placed inside cylinder of fiber glass and EPS ground between the two surfaces. Such collectors are formed by three elements: pet bottles, cans and tubes absorbers. The heating units, which form the collector contains inside the cans that can be closed, in original form or in the form of plate. The collectors have an absorber grid formed by eight absorbers PVC tube, connected through connections at T of the same material and diameter. It will be presented data of the thermal parameters which demonstrate the efficiency of the heating system proposed. Relative aspects will be boarded also the susceptibility the thermal degradation and for UV for the PVC tubes. It will be demonstrated that this alternative heating system, which has as its main feature low cost, presents thermal, economic and materials viabilities

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A análise da fluorescência da clorofila vem sendo largamente utilizada no entendimento dos mecanismos da fotossíntese propriamente dito, bem como na avaliação da capacidade fotossintética alterada com a aplicação de herbicidas. O consumo de água pelas plantas é uma maneira também de avaliar a atuação dos herbicidas nas plantas daninhas. O objetivo deste trabalho foi avaliar a fluorescência através da taxa de transporte de elétrons, consumo de água e fitointoxicação de Brachiaria decumbens após aplicação de quatro herbicidas de diferentes mecanismos de ação. Aos 30 dias após a semeadura de B. decumbens, as plantas foram arrancadas dos tubetes e preparadas para os tratamentos. Elas tiveram o sistema radicular colocado em tubos falcon preenchidos com água, e a superfície dos falcon foi isolada com papel-alumínio, para evitar evaporação do sistema. Os herbicidas aplicados foram: glyphosate, haloxyfop-methyl, diuron e amicarbazone. A aplicação foi feita com um pulverizador estacionário instalado em laboratório; após a aplicação dos tratamentos, as plantas foram mantidas em casa de vegetação. Foi avaliada a taxa de transporte de elétrons (ETR), o consumo de água e a fitointoxicação das plantas em vários períodos após o início do experimento. Os dados de ETR e fitointoxicação foram expressos em porcentagem da testemunha e submetidos à análise de variância e à comparação das médias. Para o consumo de água, os dados foram acumulados e ajustados por modelos de regressão. Assim, pode-se dizer que as plantas de B. decumbens tiveram respostas diferentes aos herbicidas aplicados, e o consumo de água das plantas está relacionado diretamente com o transporte de elétrons. A metodologia fundamentada no fluorômetro mostrou-se adequada para verificar a intoxicação antecipada em B. de cumbens submetidas ao amicarbazone e diuron antes mesmo da verificação visual de intoxicação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Structures capable of absorbing large amounts of energy are of great interest, particularly for the automotive and aviation industries, to reduce tbe impact on passengers in the case of a collision. The energy absorption properties of composite materials structures can be tailored, thus making these structures an appealing option a substitute of more traditional structures in applications where energy absorption is crucial. ln this research, the influence of some parameters, which affect the energy absorption capacity of composite material tubes, was investigated. The tubes were fabricated by hand lay-up, using orthophthalic polyester resin and a plain weave E-glass fabric Test specimens were prepared and tested under compression load. The ínfluence of the following parameters on the specific energy absorption capacity of the tubes was studied: fiber configuration (0/90º or ± 45°), tube cross-section (circular or square), and processing conditions (with or without vacuum). The results indicated that circular cross-section tubes with fibers oriented at 0/90º presented the highest level of specific energy absorbed. Further, specimens from tubes fabricated under vacuum displayed higher energy absorption capacity, when compared with specimens from tubes fabricated without vacuum. Thus, it can be concluded that the fabrication process with vacuum produce composite structures with better energy absorption capacity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It s presented a solar collector to be used in a system for heating bath water, whose main characteristic is its low cost. The collector consists of five plates of PVC with 10 mm thick, 200 mm in width and 1400mm in length, with an area equal to 1.4 square meters. The plates were connected in parallel to the ends of PVC tubes of  40 mm and 32 mm. The plates were coated on one side with aluminum sheets of soft drinks and beers cans open. The system worked on a thermosiphon and was tested in two configurations: the plates uncoated and coated with aluminum material, to determine the influence of material on the efficiency of the collector. For both configurations was used EPS plates below the surface to minimize heat losses from the botton. The thermal reservoir of the heating system is, also, alternative and low cost, since it was constructed from a polyethylene tank for storing water, with volume of 150 end 200 liters. It will be presented the thermal efficiency, heat loss, water temperature of the thermal reservoir at the end of the process and simulation of baths for a house with four residents. The will be demonstrated thermal, economic and material viability of the proposed collector, whose main innovation is the use of recyclables materials, cans of beer and soft drinks, to increase the temperature of the absorber plate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It presents a solar collector to be used in a system for heating water for bathing, whose main characteristics are its low cost and easy manufacturing and assembly. The absorbing surface of the collector is formed by an aluminum plate with eight flaps where they lodge PVC pipes. The catchment area of solar radiation corresponds to 1.3 meters. The collector box was made of wood, is covered by transparent glass and thermal insulation of tire chips and expanded polystyrene (EPS). Absorber tubes were connected in parallel through the use of PVC fittings and fixed to the plate by the use of metal poles and rivets. The entire absorber received paint flat black for better absorption of sunlight. The system worked on a thermosiphon assembly and absorber of the collector has been tested in two configurations: with the tubes facing up, directly exposed to the impact of sunlight and facing down, exchanging heat with the plate by conduction. It was determined the most efficient configuration for the correct purpose. The solar collector was connected to a thermal reservoir, also alternative, low-cost forming the system of solar water heating. We evaluated thermal parameters that proved the viability of the heating system studied

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It presents a solar collector to be used in a system for heating water for bathing, whose main characteristics are low cost and easy manufacturing and assembly. The system operates under natural convection or thermosiphon. The absorbing surface of the collector is formed by twelve PVC pipes of 25 mm outside diameter connected in parallel via connections in T of the same material. The tubes were covered with absorbing fins made with recycled aluminum cans. We studied eight settings between absorber plate, thermal insulating EPS boards and thermal reservoirs 150 and 200 liters. It was determined the most efficient configuration for the correct purpose. We evaluated thermal parameters that proved the viability of the heating system studied

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was studied a system for heating water to be used to obtain water for bathing at home, the absorbing surface of the collector is formed by one plate of polycarbonate. The polycarbonate plate has 6 mm thick, 1.050 mm wide and 1.500 mm long with an area equal to 1,575 m². The plate was attached by its edges parallel to PVC tubes of 32 mm. The system worked under the thermo-siphon and was tested for two configurations: plate absorber with and without isolation of EPS of 30 mm thick on the bottom surface in order to minimize heat losses from the bottom. The tank's thermal heating system is alternative and low cost, since it was constructed from a polyethylene reservoir for water storage, with a volume of 200 liters. Will present data on the thermal efficiency, heat loss, water temperature of thermal reservoir at the end of the process simulation and baths. Will be demonstrated the feasibility of thermal, economic and material pickup proposed for the intended purpose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presença de palha na superfície do solo influi na ciclagem do K do sistema de produção e pode alterar as propriedades químicas do solo, com possíveis reflexos na lixiviação do nutriente. No presente trabalho, foi avaliada a lixiviação de K no perfil de um solo submetido a 30 mm de chuva simulada, de acordo com doses de K aplicadas a lanço, na presença e ausência de palha de milheto na superfície do solo. O milheto foi cultivado por 55 dias em condições controladas. A seguir, foi cortado à altura do colo, em pedaços de 3 a 5 cm e colocado sobre o solo, em vasos de PVC com 20 cm de diâmetro, em quantidade equivalente a 8 t ha-1 do material seco. Sobre a palha foi aplicado cloreto de K, correspondente às doses de 0, 40, 80, 120 e 160 kg ha-1. A seguir, os vasos foram submetidos à chuva simulada equivalente a 30 mm. A palha foi coletada e analisada quanto aos teores de K, assim como o solo foi amostrado nas profundidades de 0-2, 2-4, 4-8, 8-12 e 12-20 cm de profundidade para análise de K trocável. A chuva de 30 mm foi necessária e suficiente para carrear para o solo o fertilizante potássico aplicado sobre a palha. A intensidade de lixiviação do K no perfil do solo foi proporcional à dose aplicada, de modo que uma chuva de 30 mm lixiviou o nutriente até a camada de 8-12 cm de profundidade, quando o solo estava descoberto. A presença de palha de milheto na superfície do solo aumentou a quantidade de K levada até à superfície do solo pela chuva, mas diminuiu a intensidade de lixiviação do nutriente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It presents a new type of insulation for ductwork hot water, which can be used in solar systems for heating water, which consists of a composite of different compositions based on plaster, cement and EPS ground, palm and water. This composite has as its main features easy assembly and manufacturing processes and low cost. Comparative results will be presented on the tests of materials and thermal tubes proposed. Four formulations were used to manufacture tubes with three diameters 70, 65 and 42mm. It was also tested conventionally used for elastomeric foam insulation to 110 ° C, for a comparative analysis with the composite pipe insulator proposed. It will demonstrate that the cost of manufacturing of such tubes is competitive with alternative elastomeric foam tested, but results of the composite tube to the temperature range studied, are lower. Another drawback of the composite insulator tube is its large mass. It would be important to test such a composite for greater levels of temperature to a diagnostic technique competitive with conventionally used insulators. A positive factor of using the proposed composite-tube would be the recycling of EPS so damaging to the environment, representing an environmentally friendly application of science

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a seletividade e a absorção do sulfentrazone em clones de eucalipto. O primeiro experimento foi instalado em casa de vegetação, em delineamento inteiramente casualizado, com quatro repetições, no esquema fatorial 2 x 4, sendo duas doses do sulfentrazone (400 e 600 g ha-1) e quatro clones de eucalipto, híbridos de Eucalyptus grandis x E. urophylla (FB1, FB2, FB3 e FB4). Foram realizadas avaliações visuais de intoxicação das plantas de eucalipto e, no final do estudo, determinou-se a massa seca da parte aérea dos clones. No segundo experimento, foram utilizados os mesmos clones, sendo estes acondicionados em tubos falcon com 50 mL da solução contendo o sulfentrazone na concentração de 129 mM. As plantas de eucalipto permaneceram por 24 horas com as raízes imersas na solução e, em seguida, foi realizada a extração da seiva do xilema das plantas por meio de uma câmara de pressão. A concentração de sulfentrazone na seiva das plantas foi determinada através de cromatografia líquida e espectrometria de massas. O clone FB3 apresentou menor acúmulo de massa seca em relação aos demais, o que pode estar diretamente associado aos altos níveis de intoxicação observados. O clone FB2, apesar de mostrar elevada intoxicação, não apresentou níveis tão elevados de redução de massa seca em relação à testemunha. No tocante às concentrações de sulfentrazone nas plantas, elas foram proporcionais ao acúmulo de massa seca, o que indica que as variações na seletividade dos clones de eucalipto podem estar relacionadas à absorção diferenciada do herbicida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O manejo correto da adubação potássica pode minimizar perdas assim como evitar o esgotamento de K do solo. Objetivou-se estudar a dinâmica do K no perfil do solo em função do teor de argila e do teor do nutriente resultantes da adubação da soja. Foram coletados solos de texturas média e argilosa, que vinham sendo adubados com 0, 60, 120, e 180 kg ha-1 de K2O na soja por 6 anos. O experimento foi conduzido em casa de vegetação, em tubos de PVC estratificados nas profundidades de 0-5, 5-10, 10-20, e 20-40 cm. Na superfície das colunas, aplicaram-se mais 80 kg ha-1 de K2O. Durante 16 semanas, foi aplicada, semanalmente, água em quantidade equivalente a 100 mm de chuva. em cada aplicação, o volume de solução percolada foi determinado, assim como as quantidades de K contidas nessa solução. Após a desmontagem das colunas de solo, foram determinados os teores de K trocável e não-trocável nas diferentes profundidades. A percolação de K foi maior no solo de textura argilosa, que tinha mais K disponível devido ao maior efeito residual da adubação potássica anterior. A intensidade de lixiviação foi proporcional ao teor de K disponível, mas inicialmente a lixiviação foi mais intensa no solo mais arenoso, decrescendo com o tempo. No argiloso, as perdas foram mais constantes. Houve proporcionalidade entre teor inicial e lixiviação no perfil do solo, nas duas formas de K e nos dois tipos de solo. Conclui-se que o efeito residual da adubação potássica aumentou as quantidades de K percolado. A movimentação de K no perfil do solo teve boa relação com o teor inicial de K no solo, resultante da adubação potássica anterior nos dois tipos de solo. A passagem de K considerado não-trocável para trocável foi rápida e influenciou na lixiviação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A resistência do solo à penetração é relacionada com a textura, compactação e umidade do solo. No presente trabalho se estudou o efeito da interação desses fatores sobre o crescimento de raízes de milho. Materiais de solo com 22, 30, 34, 41 e 48% de argila foram acondicionados em tubos de PVC de 10 cm com 4,3 cm de diâmetro interno, nas densidades globais de 1,07, 1,18, 1,36 e 1,53 g cm-3, em três tensões de água: -0,034, -0,106 e -0,640 MPa. Plântulas de milho foram cultivadas nos tubos por 48 horas. Quando a densidade do solo é baixa, a textura tem papel preponderante no crescimento radicular. Esse efeito é menor à medida que aumenta a densidade global. O aumento da resistência do solo à penetração causa diminuição no comprimento e número de raízes seminais adventícias; a raiz seminal primária mostra menor capacidade de penetração do que as raízes seminais adventícias. Resistências do solo à penetração da ordem de 1,3 MPa reduzem à metade o crescimento das raízes seminais adventícias do milho.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)