955 resultados para Optical sensor systems


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A good system of preventive bridge maintenance enhances the ability of engineers to manage and monitor bridge conditions, and take proper action at the right time. Traditionally infrastructure inspection is performed via infrequent periodical visual inspection in the field. Wireless sensor technology provides an alternative cost-effective approach for constant monitoring of infrastructures. Scientific data-acquisition systems make reliable structural measurements, even in inaccessible and harsh environments by using wireless sensors. With advances in sensor technology and availability of low cost integrated circuits, a wireless monitoring sensor network has been considered to be the new generation technology for structural health monitoring. The main goal of this project was to implement a wireless sensor network for monitoring the behavior and integrity of highway bridges. At the core of the system is a low-cost, low power wireless strain sensor node whose hardware design is optimized for structural monitoring applications. The key components of the systems are the control unit, sensors, software and communication capability. The extensive information developed for each of these areas has been used to design the system. The performance and reliability of the proposed wireless monitoring system is validated on a 34 feet span composite beam in slab bridge in Black Hawk County, Iowa. The micro strain data is successfully extracted from output-only response collected by the wireless monitoring system. The energy efficiency of the system was investigated to estimate the battery lifetime of the wireless sensor nodes. This report also documents system design, the method used for data acquisition, and system validation and field testing. Recommendations on further implementation of wireless sensor networks for long term monitoring are provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electronic canopy characterization is an important issue in tree crop management. Ultrasonic and optical sensors are the most used for this purpose. The objective of this work was to assess the performance of an ultrasonic sensor under laboratory and field conditions in order to provide reliable estimations of distance measurements to apple tree canopies. To this purpose, a methodology has been designed to analyze sensor performance in relation to foliage ranging and to interferences with adjacent sensors when working simultaneously. Results show that the average error in distance measurement using the ultrasonic sensor in laboratory conditions is ±0.53 cm. However, the increase of variability in field conditions reduces the accuracy of this kind of sensors when estimating distances to canopies. The average error in such situations is ±5.11 cm. When analyzing interferences of adjacent sensors 30 cm apart, the average error is ±17.46 cm. When sensors are separated 60 cm, the average error is ±9.29 cm. The ultrasonic sensor tested has been proven to be suitable to estimate distances to the canopy in field conditions when sensors are 60 cm apart or more and could, therefore, be used in a system to estimate structural canopy parameters in precision horticulture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interception requires precise estimation of time-to-contact (TTC) information. A long-standing view posits that all relevant information for extracting TTC is available in the angular variables, which result from the projection of distal objecs on to the retina. The diferent timing models rooted in this tradition have consequently relied on combining visual angle and its rate of expansion in diferent ways with tau being the most well-known solution for TTC...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for optimizing the strength of a parametric phase mask for a wavefront coding imaging system is presented. The method is based on an optimization process that minimizes a proposed merit function. The goal is to achieve modulation transfer function invariance while quantitatively maintaining nal image delity. A parametric lter that copes with the noise present in the captured images is used to obtain the nal images, and this lter is optimized. The whole process results in optimum phase mask strength and optimal parameters for the restoration lter. The results for a particular optical system are presented and tested experimentally in the labo- ratory. The experimental results show good agreement with the simulations, indicating that the procedure is useful.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report optical spectroscopic observations of a sample of 6 low-galactic latitude microquasar candidates selected by cross-identification of X-ray and radio point source catalogs for |b|<5 degrees. Two objects resulted to be of clear extragalactic origin, as an obvious cosmologic redshift has been measured from their emission lines. For the rest, none exhibits a clear stellar-like spectrum as would be expected for genuine Galactic microquasars. Their featureless spectra are consistent with being extragalactic in origin although two of them could be also highly reddened stars. The apparent non-confirmation of our candidates suggests that the population of persistent microquasar systems in the Galaxy is more rare than previously believed. If none of them is galactic, the upper limit to the space density of new Cygnus X-3-like microquasars within 15 kpc would be 1.1\times10^{-12} per cubic pc. A similar upper limit for new LS 5039-like systems within 4 kpc is estimated to be 5.6\times10^{-11} per cubic pc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Imaging systems have developed latest years and developing is still continuing following years. Manufacturers of imaging systems give promises for the quality of the performance of imaging systems to advertise their products. Promises for the quality of the performance are often so good that they will not be tested in normal usage. The main target in this research is to evaluate the quality of the performance of two imaging systems: Scanner and CCD color camera. Optical measurement procedures were planned to evaluate the quality of imaging performances. Other target in this research is to evaluate calibration programs for the camera and the scanner. Measuring targets had to choose to evaluate the quality of imaging performances. Manufacturers have given definitions for targets. The third task in this research is to evaluate and consider how good measuring targets are.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aquest projecte s’emmarca dins de l’àmbit de la visió per computador, concretament en la utilització de dades de profunditat obtingudes a través d’un emissor i sensor de llum infraroja.El propòsit principal d’aquest projecte és mostrar com adaptar aquestes tecnologies, a l’abast de qualsevol particular, de forma que un usuari durant la pràctica d’una activitat esportiva concreta, rebi informació visual continua dels moviments i gestos incorrectes que està realitzant, en base a uns paràmetres prèviament establerts.L’objectiu d’aquest projecte consisteix en fer una lectura constant en temps real d’una persona practicant una selecció de diverses activitats esportives estàtiques utilitzant un sensor Kinect. A través de les dades obtingudes pel sensor Kinect i utilitzant les llibreries de “skeleton traking” proporcionades per Microsoft s’haurà d’interpretar les dades posturals obtingudes per cada tipus d’esport i indicar visualment i d’una manera intuïtiva els errors que està cometent en temps real, de manera que es vegi clarament a quina part del seu cos realitza un moviment incorrecte per tal de poder corregir-lo ràpidament. El entorn de desenvolupament que s’utilitza per desenvolupar aquesta aplicació es Microsoft Viusal Studio 2010.El llenguatge amb el qual es treballarà sobre Microsoft Visual Studio 2010 és C#

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, Wireless Sensor Networks (WSN) arealready a very important data source to obtain data about the environment. Thus, they are key to the creation of Cyber-Physical Systems (CPS). Given the popularity of P2P middlewares as ameans to efficiently process information and distribute services, being able to integrate them to WSN¿s is an interesting proposal. JXTA is a widely used P2P middleware that allows peers to easily exchange information, heavily relying on its main architectural highlight, the capability to organize peers with common interests into peer groups. However, right now, approaches to integrate WSNs to a JXTA network seldom take advantage of peer groups. For this reason, in this paper we present jxSensor, an integrationlayer for sensor motes which facilitates the deployment of CPS¿s under this architecture. This integration has been done taking into account JXTA¿s idiosyncrasies and proposing novel ideas,such as the Virtual Peer, a group of sensors that acts as a single entity within the peer group context.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fabrication of new optical devices based upon the incorporation of rare earth ions via sol-gel methods depends on elimination of dopant ion clusters and residual hydroxyl groups from the final material. The optical absorption and/or luminescence properties of luminescent rare earth ions are influenced by the local bonding environment and the distribution of the rare-earth dopants in the matrix. Typically, dopants are incorporated into gel via dissolution of soluble species into the initial precursor sol. In this work, Eu3+ is used as optical probe, to assess changes in the local environment. Results of emission, excitation, fluorescence line narrowing and lifetimes studies of Eu3+-doped gels derived from Si(OCH3)4 and fluorinated/chelate Eu3+ precursors are presented. The precursors used in the sol-gel synthesis were: tris (6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedionate) Eu(III), Eu (III) trifluoromethanesulfonate, Eu(III) acetylacetonate hydrate, Eu (III) trifluoroacetate trihidrate, tris (2,2,6,6-tetramethyl-3,5- heptanedionate) Eu(III) and Eu(NO3)3.6H2O. The results were interpreted in terms of the evolution of the Eu3+ fluorescence in systems varying from solution to the gels densified to 800ºC. The lifetimes studies indicate that the fluorinated precursors are effective at reducing the water content in densified gels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel cantilever pressure sensor was developed in the Department of Physics at the University of Turku in order to solve the sensitivity problems which are encountered when condenser microphones are used in photoacoustic spectroscopy. The cantilever pressure sensor, combined with a laser interferometer for the measurement of the cantilever movements, proved to be highly sensitive. The original aim of this work was to integrate the sensor in a photoacoustic gas detector working in a differential measurement scheme. The integration was made successfully into three prototypes. In addition, the cantilever was also integrated in the photoacoustic FTIR measurement schemes of gas-, liquid-, and solid-phase samples. A theoretical model for the signal generation in each measurement scheme was created and the optimal celldesign discussed. The sensitivity and selectivity of the differential method were evaluated when a blackbody radiator and a mechanical chopper were used with CO2, CH4, CO, and C2H4 gases. The detection limits were in the sub-ppm level for all four gases with only a 1.3 second integration time and the cross interference was well below one percent for all gas combinations other than those between hydrocarbons. Sensitivity with other infrared sources was compared using ethylene as an example gas. In the comparison of sensitivity with different infrared sources the electrically modulated blackbody radiator gave a 35 times higher and the CO2-laser a 100 times lower detection limit than the blackbody radiator with a mechanical chopper. As a conclusion, the differential system is well suited to rapid single gas measurements. Gas-phase photoacoustic FTIR spectroscopy gives the best performance, when several components have to be analyzed simultaneously from multicomponent samples. Multicomponent measurements were demonstrated with a sample that contained different concentrations of CO2, H2O, CO, and four different hydrocarbons. It required an approximately 10 times longer measurement time to achieve the same detection limit for a single gas as with the differential system. The properties of the photoacoustic FTIR spectroscopy were also compared to conventional transmission FTIR spectroscopy by simulations. Solid- and liquid-phase photoacoustic FTIR spectroscopy has several advantages compared to other techniques and therefore it also has a great variety of applications. A comparison of the signal-to-noise ratio between photoacoustic cells with a cantilever microphone and a condenser microphone was done with standard carbon black, polyethene, and sunflower oil samples. The cell with the cantilever microphone proved to have a 5-10 times higher signal-to-noise ratio than the reference detector, depending on the sample. Cantilever enhanced photoacoustics will be an effective tool for gas detection and analysis of solid- and liquid-phase samples. The preliminary prototypes gave good results in all three measurement schemes that were studied. According to simulations, there are possibilities for further enhancement of the sensitivity, as well as other properties, of each system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the literature survey retention mechanisms, factors effecting retention and microparticles were studied. Also commercial microparticle retention systems and means to measure retention were studied. Optical retention measurement with RPA and Lasentec FBRM was studied. The experimental part contains study of different cationic polyacrylamides, anionic silica, bentonite and new generation micropolymer. In these studies the dosage, dosing order and dosing history were changing factors. The experimental work was done with RPA-apparatus with which, the retention process can be followed in real time. In testing was found that silica yielded better retention, when dosed nontraditionally before the polymer. Also silica was very dependant on the polymer dosage. With bentonite good colloidal retention was achieved with relatively low doses. Unlike silica bentonite was not dependant on polymer dosage. The relation of bentonite and polymer dosage is more defining when high retention is wanted. With 3-component systems using bentonite very high retention was achieved. With silica no improvement in retention was found in 3-component systems compared to dual component systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article presents a discussion on light diffraction by slits and grids as well as the development of an experimental apparatus which provides quantitative observation of the phenomenon. We conducted a brief historical survey on the evolution of the wave theory of light and the role of diffraction in the context of optical spectroscopy. We also reviewed the use of Huygens’ principle to calculate the intensity pattern obtained when light is diffracted by slits and compared the predictions with experimental results obtained using the apparatus developed. Finally, the use of the apparatus in an optical spectroscopy experiment was demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the modern warfare there is an active development of a new trend connected with a robotic warfare. One of the critical elements of robotics warfare systems is an automatic target recognition system, allowing to recognize objects, based on the data received from sensors. This work considers aspects of optical realization of such a system by means of NIR target scanning at fixed wavelengths. An algorithm was designed, an experimental setup was built and samples of various modern gear and apparel materials were tested. For pattern testing the samples of actively arm engaged armies camouflages were chosen. Tests were performed both in clear atmosphere and in the artificial extremely humid and hot atmosphere to simulate field conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the introduction of automatic orbital welding in pipeline application in 1961, significant improvements have been obtained in orbital pipe welding systems. Requirement of more productive welding systems for pipeline application forces manufacturers to innovate new advanced systems and welding processes for orbital welding method. Various methods have been used to make welding process adaptive, such as visual sensing, passive visual sensing, real-time intelligent control, scan welding technique, multi laser vision sensor, thermal scanning, adaptive image processing, neural network model, machine vision, and optical sensing. Numerous studies are reviewed and discussed in this Master’s thesis and based on a wide range of experiments which already have been accomplished by different researches the vision sensor are reported to be the best choice for adaptive orbital pipe welding system. Also, in this study the most welding processes as well as the most pipe variations welded by orbital welding systems mainly for oil and gas pipeline applications are explained. The welding results show that Gas Metal Arc Welding (GMAW) and its variants like Surface Tension Transfer (STT) and modified short circuit are the most preferred processes in the welding of root pass and can be replaced to the Gas Tungsten Arc Welding (GTAW) in many applications. Furthermore, dual-tandem gas metal arc welding technique is currently considered the most efficient method in the welding of fill pass. Orbital GTAW process mostly is applied for applications ranging from single run welding of thin walled stainless tubes to multi run welding of thick walled pipes. Flux cored arc welding process is faster process with higher deposition rate and recently this process is getting more popular in pipe welding applications. Also, combination of gas metal arc welding and Nd:YAG laser has shown acceptable results in girth welding of land pipelines for oil and gas industry. This Master’s thesis can be implemented as a guideline in welding of pipes and tubes to achieve higher quality and efficiency. Also, this research can be used as a base material for future investigations to supplement present finding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The irrigation management based on the monitoring of the soil water content allows for the minimization of the amount of water applied, making its use more efficient. Taking into account these aspects, in this work, a sensor for measuring the soil water content was developed to allow real time automation of irrigation systems. This way, problems affecting crop yielding such as irregularities in the time to turn on or turn off the pump, and excess or deficit of water can be solved. To develop the sensors were used stainless steel rods, resin, and insulating varnish. The sensors measuring circuit was based on a microcontroller, which gives its output signal in the digital format. The sensors were calibrated using soil of the type “Quartzarenic Neosoil”. A third order polynomial model was fitted to the experimental data between the values of water content corresponding to the field capacity and the wilting point to correlate the soil water content obtained by the oven standard method with those measured by the electronic circuit, with a coefficient of determination of 93.17%, and an accuracy in the measures of ±0.010 kg kg-1. Based on the results, it was concluded that the sensor and its implemented measuring circuit can be used in the automation process of irrigation systems.