998 resultados para Optical Sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of American cutaneous leishmaniasis (ACL) is frequently based on clinical and epidemiological data associated with the results of laboratory tests. Some laboratory methods are currently being applied for the diagnosis of ACL, among them the indirect immunofluorescence reaction (IIFR), the Montenegro skin test (MST), histopathological examination, and the polymerase chain reaction (PCR). The performance of these methods varies in a considerable proportion of patients. After the standardization of an immunoenzymatic test (ELISA) for the detection of IgG in the serum of patients with ACL using a crude Leishmania braziliensis antigen, the results obtained were compared to those of other tests routinely used for the diagnosis. The tests revealed the following sensitivity, when analyzed separately: 85% for ELISA IgG, 81% for PCR, 64.4% for MST, 58.1% for IIFR, and 34% for the presence of parasites in the biopsy. ELISA was positive in 75% of patients with ACL presenting a negative MST, in 84.8% of ACL patients with negative skin or mucous biopsies for the presence of the parasite, and in 100% of cases with a negative PCR. Thus, ELISA presented a higher sensitivity than the other tests and was useful as a complementary method for the diagnosis of ACL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis); we performed visual inspection and thereafter wet combing (gold standard). Of the 175 individuals included, 77 (44%) had an active head lice infestation. For self-diagnosis, sensitivity (80.5%), specificity (91.8%), PPV (88.6%) and NPV (85.7%) were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesive bonding is an excellent alternative to traditional joining techniques such as welding, mechanical fastening or riveting. However, there are many factors that have to be accounted for during joint design to accurately predict the joint strength. One of these is the adhesive layer thickness (tA). Most of the results are for epoxy structural adhesives, tailored to perform best with small values of tA, and these show that the lap joint strength decreases with increase of tA (the optimum joint strength is usually obtained with tA values between 0.1 and 0.2 mm). Recently, polyurethane adhesives were made available in the market, designed to perform with larger tA values, and whose fracture behaviour is still not studied. In this work, the effect of tA on the tensile fracture toughness (View the MathML source) of a bonded joint is studied, considering a novel high strength and ductile polyurethane adhesive for the automotive industry. This work consists on the fracture characterization of the bond by a conventional and the J-integral techniques, which accurately account for root rotation effects. An optical measurement method is used for the evaluation of crack tip opening (δn) and adherends rotation at the crack tip (θo) during the test, supported by a Matlab® sub-routine for the automated extraction of these parameters. As output of this work, fracture data is provided in traction for the selected adhesive, enabling the subsequent strength prediction of bonded joints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of adhesive joints has increased in recent decades due to its competitive features compared with traditional methods. This work aims to estimate the tensile critical strain energy release rate (GIC) of adhesive joints by the Double-Cantilever Beam (DCB) test. The J-integral is used since it enables obtaining the tensile Cohesive Zone Model (CZM) law. An optical measuring method was developed for assessing the crack tip opening (δn) and adherends rotation (θo). The proposed CZM laws were best approximated by a triangular shape for the brittle adhesive and a trapezoidal shape for the two ductile adhesives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prospective testing for posttransplant circulating anti-HLA antibodies seems to be a critical noninvasive tool, but confirmatory data are lacking. MATERIALS AND METHODS: Over the last 3 years, peritubular capillary (PTC) C4d deposition was prospectively sought by an immunofluorescence technique applied to frozen tissue in biopsies obtained for allograft dysfunction. Screening for circulating anti-HLA class I/II alloantibodies (AlloAb) by the flow cytometric test was performed simultaneously. RESULTS: We evaluated 132 sets of biopsies and simultaneous serum samples. PTC C4d deposition was demonstrated in 15.9% (21/132) of biopsies. Circulating anti-HLA I/II AlloAb were detected in 25% (33/132) of serum samples. Employing receiver-operator characteristic (ROC) curves for all C4d-positive biopsies, screening for AlloAb showed a global specificity of 82% and sensitivity of 61.9%. When this analysis was restricted to biopsies obtained in the first month posttransplantation, the sensitivity increased to 81.8%, but the specificity decreased to 76.9%. After the first month posttransplantation, we observed sensitivity of 40.0% and a specificity of 86.4%. In the first month posttransplantation, all patients with a diagnosis of acute antibody-mediated rejection displayed circulating anti-HLA class I/II, but not always at the same time as the C4d-positive biopsy. CONCLUSIONS: In the first month posttransplantation, prospective monitoring of anti-HLA antibodies may be useful. The high sensitivity allows the identification of patients at risk, affording an earlier diagnosis of antibody-mediated rejection. After the first month, the test can be used to evaluate allograft dysfunction episodes, since positivity is highly suggestive of an antibody-mediated process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the objective to study the variation of optical properties of rat muscle during optical clearing, we have performed a set of optical measurements from that kind of tissue. The measurements performed were total transmittance, collimated transmittance, specular reflectance and total reflectance. This set of measurements is sufficient to determine diffuse reflectance and absorbance of the sample, also necessary to estimate the optical properties. All the performed measurements and calculated quantities will be used later in inverse Monte Carlo (IMC) simulations to determine the evolution of the optical properties of muscle during treatments with ethylene glycol and glucose. The results obtained with the measurements already provide some information about the optical clearing treatments applied to the muscle and translate the mechanisms of turning the tissue more transparent and sequence of regimes of optical clearing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of agent diffusion in biological tissues is very important to understand and characterize the optical clearing effects and mechanisms involved: tissue dehydration and refractive index matching. From measurements made to study the optical clearing, it is obvious that light scattering is reduced and that the optical properties of the tissue are controlled in the process. On the other hand, optical measurements do not allow direct determination of the diffusion properties of the agent in the tissue and some calculations are necessary to estimate those properties. This fact is imposed by the occurrence of two fluxes at optical clearing: water typically directed out of and agent directed into the tissue. When the water content in the immersion solution is approximately the same as the free water content of the tissue, a balance is established for water and the agent flux dominates. To prove this concept experimentally, we have measured the collimated transmittance of skeletal muscle samples under treatment with aqueous solutions containing different concentrations of glucose. After estimating the mean diffusion time values for each of the treatments we have represented those values as a function of glucose concentration in solution. Such a representation presents a maximum diffusion time for a water content in solution equal to the tissue free water content. Such a maximum represents the real diffusion time of glucose in the muscle and with this value we could calculate the corresponding diffusion coefficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Evaluate the sensitivity/specificity of immunoperoxidase method in comparison with the standard immunofluorescence. MATERIAL AND METHODS: Retrospective review of 87 biopsies made for allograft dysfunction. Immunofluorescence (IF) was performed in frozen allograft biopsies using monoclonal antibody anti-C4d from Quidel®. The indirect immunoperoxidase (IP) technique was performed in paraffin-embebbed tissue with polyclonal antiserum from Serotec®. Biopsies were independently evaluated by two nephropathologist according Banff 2007 classification. RESULTS: By IF, peritubular C4d deposition were detected in 60 biopsies and absent in 27 biopsies. The evaluation of biopsy by IP was less precise due to the presence of background and unspecific staining. We find 13.8% (12/87) of false negative and Banff classification concordance in 79.3% (69/87) of cases (table1). The ROC curve study reveal a specificity of 100% and sensitivity of 80.0 % of IP method in relation to the gold standard (area under curve:0.900; 95% Confidence interval :0.817-0.954; p=0.0001). Banff Classification C4d Cases Immunofluorescence Immunoperoxidase n =87 Diffuse Negative 3 (3.4%) Focal Negative 9 (10.3%) Negative Negative 27 (31.0%) Diffuse Diffuse 33 (37.9%) Focal Focal 9 (10.3%) Diffuse Focal 6 (6.9%) CONCLUSION: The IP method presents a good specificity, but lesser sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring more experience of the observer than IF method. If frozen tissue is unavailable, the use of IP for C4d detection is acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of chemical diffusion in biological tissues is a research field of high importance and with application in many clinical, research and industrial areas. The evaluation of diffusion and viscosity properties of chemicals in tissues is necessary to characterize treatments or inclusion of preservatives in tissues or organs for low temperature conservation. Recently, we have demonstrated experimentally that the diffusion properties and dynamic viscosity of sugars and alcohols can be evaluated from optical measurements. Our studies were performed in skeletal muscle, but our results have revealed that the same methodology can be used with other tissues and different chemicals. Considering the significant number of studies that can be made with this method, it becomes necessary to turn data processing and calculation easier. With this objective, we have developed a software application that integrates all processing and calculations, turning the researcher work easier and faster. Using the same experimental data that previously was used to estimate the diffusion and viscosity of glucose in skeletal muscle, we have repeated the calculations with the new application. Comparing between the results obtained with the new application and with previous independent routines we have demonstrated great similarity and consequently validated the application. This new tool is now available to be used in similar research to obtain the diffusion properties of other chemicals in different tissues or organs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho consistiu em projetar, construir e testar um protótipo em laboratório de uma fonte de alimentação de alta tensão que permita descargas elétricas {estáveis e de dimensões reduzidas}, de modo a que possa ser utilizada, dada a sua essencialidade, na fabricação de redes de período longo (LPG) em fibra ótica nos chamados turning points. Estes são pontos de elevada sensibilidade, fundamentais no desenvolvimento tecnológico de sensores em fibra ótica, em particular, de sensores refractométricos. O protótipo da fonte de alimentação é composto por um regulador do tipo BUCK, um inversor para alimentação do transformador de alta tensão, o circuito de realimentação e controlo PWM e um microcontrolador para o comando da fonte. Posteriormente procedeu-se à otimização dos parâmetros de descarga, o que conduziu a fabricação de redes de período longo com períodos inferiores a 150 micrómetros. Este é um resultado sem paralelo a nível internacional no que concerne ao uso da técnica do arco elétrico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues. If applied in cooperation with clinical methods it provides optimization of diagnosis and treatment procedures. This technique turns biological tissues more transparent through two main mechanisms — tissue dehydration and refractive index (RI) matching between tissue components. Such matching is obtained by partial replacement of interstitial water by a biocompatible agent that presents higher RI and it can be completely reversible by natural rehydration in vivo or by assisted rehydration in ex vivo tissues. Experimental data to characterize and discriminate between the two mechanisms and to find new ones are necessary. Using a simple method, based on collimated transmittance and thickness measurements made from muscle samples under treatment, we have estimated the diffusion properties of glucose, ethylene glycol (EG) and water that were used to perform such characterization and discrimination. Comparing these properties with data from literature that characterize their diffusion in water we have observed that muscle cell membrane permeability limits agent and water diffusion in the muscle. The same experimental data has allowed to calculate the optical clearing (OC) efficiency and make an interpretation of the internal changes that occurred in muscle during the treatments. The same methodology can now be used to perform similar studies with other agents and in other tissues in order to solve engineering problems at design of inexpensive and robust technologies for a considerable improvement of optical tomographic techniques with better contrast and in-depth imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary optical coherence tomography has emerged as the most powerful in-vivo imaging modality to evaluate vessel structure in detail. It is a useful research tool that provides insights into the pathogenesis of coronary artery disease. This technology has an important clinical role that is still being developed. We review the evidence on the wide spectrum of potential clinical applications for coronary optical coherence tomography, which encompass the successive stages in coronary artery disease management: accurate lesion characterization and quantification of stenosis, guidance for the decision to perform percutaneous coronary intervention and subsequent planning, and evaluation of immediate and long-term results following intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four methods for detecting household infestations with Panstrongylus megistus were compared: 1) manual collection; 2) collection after pyrethrum application; 3) search viable eggs; and 4) Gomez-Nuñez boxes. Manual collection was the most sensitive method (23% infested), followed by pyrethrum (21%), Gomez-Nuñez boxes (15%) and viable eggs (12%). About 10% of infested houses were positive exclusively on the Gomez-Nuñez box test. More over, 6 out of the 7 houses positive exclusively on the Gomez-Nuñez method were located in a recently sprayed area, where P. megistus density was low. Inspection of Gomez-Nuñez boxes at 12 weekspost-application was twice as effective as inspection at 6 weekspost-application. Triatomine feces was the most common evidencefor thepresence of P. megistus found within Gomez-Nuñez boxes. Gomez-Nuñez boxes area a useful adjunct to manual collection in detecting domestic infestations with P. megistus, especially in areas where bug densities are low. However, the utility of Gomez-Nuhez boxes must be weighed against the time and labor they require.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The osmotic threshold for attaining the antidiuretic response to hypertonic saline infusion and Progressive dehydration was studied in 31 patients with the chronic form of Chagas' disease and 16 control patients. The chagasic patients exhibited enhanced osmoticsensitivity to the antidiuretic response. This was demonstrated by lower values of the increments in plasma osmolarity sufficient to induce a significant fall in water clearance, without alterations in the osmolar clearance or creatinine excretion. The time needed to attain the antidiuretic response was shorterfor chagasics in relation to normal subjects. The results suggest the existence of a disturbance in the fine control of osmoregulation in the chagasic patients. They are interpreted to be a consequence of the denervation in hypothalamic or extrahypothalamic areas that regulate the secretion of vasopressin in chronic Chagas' disease.