942 resultados para Operating costs.
Resumo:
For 10 years the Institute for Fishing Technology, Hamburg (IFH) has been carrying out experiments in the brown shrimp fishery with beam trawls aiming at a reduction of unwanted bycatches. When the tests were transferred to commercial fishery conditions the personnel effort and costs increased markedly. It became e.g. necessary to install a deep-freeze chain to make it possible to evaluate more samples in the laboratory. This again required to increase the number of technicians for measuring the fish and shrimp samples, but also made it necessary to perform this work in the most rational and time-saving way by applying modern electronic aids. Though all samples still have to be sorted by species and have to be weighed and measured the introduction of electronic aids, however, like electronic measuring board and computer-aided image processing system, all weight and length data are immediately and digitally recorded after processing. They are transferred via a network to a server PC which stores them into a purpose-designed database. This article describes the applicationof two electronic systems: the measuring board (FM 100, Fa. SCANTROL), iniated by a project in the Norwegian Institute for Fishing Technology, and a computer-aided image processing system, focussing on measuring shrimps in their naturally flexed shape, also developed in the Institute for Fishing Technology in close collaboration with the University of Duisburg. These electronic recording systems allow the consistent and reproducible record of data independent of the changing day-to-day personal form of the staff operating them. With the help of these systems the number of measurements the laboratory could be maximized to 250 000 per year. This made it possible to evaluate, in 1999, 525 catch samples from 75 commercial hauls taken during 15 days at sea. The time gain in measuring the samples is about one third of the time previously needed (i.e. one hour per sample). An additional advantage is the immediate availability of the digitally stored data which enables rapid analyses of all finished subexperiments. Both systems are applied today in several institutes of the Federal Research Centre. The image processing system is now the standard measuring method in an international research project.
Resumo:
A diode stack end-pumped Nd:YVO4 slab laser at 1342 nm with near-diffraction-limited beam quality by using a hybrid resonator was presented. At a pump power of 139.5 W, laser power of 35.4 W was obtained with a conversion efficiency of 25.4% of the laser diode to laser output. The beam quality M-2 factors were measured to be 1.2 in the unstable direction and 1.3 in the stable direction at the output power of 29 W. (C) 2009 Optical Society of America
Resumo:
The critical cavitating flow in liquid jet pumps under operating limits is investigated in this paper. Measurements on the axial pressure distribution along the wall of jet pumps indicate that two-phase critical flow occurs in the throat pipe under operating limits. The entrained flow rate and the distribution of the wall pressure upstream lowest pressure section does not change when the outlet pressure is lower than a critical value. A liquid-vapor mixing shockwave is also observed under operating limits. The wave front moves back and forth in low frequency around the position of the lowest pressure. With the measured axial wall pressures, the Mach number of the two-phase cavitating flow is calculated. It's found that the maximum Mach number is very close to I under operating limits. Further analysis infers a cross-section where Mach number approaches to I near the wave front. Thus, the liquid-vapor mixture velocity should reach the local sound velocity and resulting in the occurrence of operating limits.
Resumo:
A modelling study is performed to investigate the characteristics of both plasma flow and heat transfer of a laminar non-transferred arc argon plasma torch operated at atmospheric and reduced pressure. It is found that the calculated flow fields and temperature distributions are quite similar for both cases at a chamber pressure of 1.0 atm and 0.1 atm. A fully developed flow regime could be achieved in the arc constrictor-tube between the cathode and the anode of the plasma torch at 1.0 atm for all the flow rates covered in this study. However the flow field could not reach the fully developed regime at 0.1 atm with a higher flow rate. The arc-root is always attached to the torch anode surface near the upstream end of the anode, i.e. the abruptly expanded part of the torch channel, which is in consistence with experimental observation. The surrounding gas would be entrained from the torch exit into the torch interior due to a comparatively large inner diameter of the anode channel compared to that of the arc constrictor-tube.
Resumo:
25 p.
Resumo:
34 p.
Resumo:
30 p.
Resumo:
23 p.
Resumo:
21 p.
Resumo:
35 p.
Resumo:
During the 1950s and 1960s, F.J.H. Mackereth developed and published plans for a series of pneumatic samplers for lake sediments. Unfortunately, as the equipment was continually evolving during ensuing research, no user manuals, beyond the original publication, had been produced. Over the last few years there have been a few potentially very serious accidents with the 1-metre corer, which has prompted the authors to carry out a risk assessment. This highlighted two weaknesses in the design and its later developments. They can be corrected simply by checking for screw threads that may have been added to the exhaust port on the mini-corer, and by changing the operating procedure. An A4 nine-page user manual is now available from the authors. A small charge ( pound sterling 10 in 1998) will be made to cover handling costs and postage.
Resumo:
With continuing advances in CMOS technology, feature sizes of modern Silicon chip-sets have gone down drastically over the past decade. In addition to desktops and laptop processors, a vast majority of these chips are also being deployed in mobile communication devices like smart-phones and tablets, where multiple radio-frequency integrated circuits (RFICs) must be integrated into one device to cater to a wide variety of applications such as Wi-Fi, Bluetooth, NFC, wireless charging, etc. While a small feature size enables higher integration levels leading to billions of transistors co-existing on a single chip, it also makes these Silicon ICs more susceptible to variations. A part of these variations can be attributed to the manufacturing process itself, particularly due to the stringent dimensional tolerances associated with the lithographic steps in modern processes. Additionally, RF or millimeter-wave communication chip-sets are subject to another type of variation caused by dynamic changes in the operating environment. Another bottleneck in the development of high performance RF/mm-wave Silicon ICs is the lack of accurate analog/high-frequency models in nanometer CMOS processes. This can be primarily attributed to the fact that most cutting edge processes are geared towards digital system implementation and as such there is little model-to-hardware correlation at RF frequencies.
All these issues have significantly degraded yield of high performance mm-wave and RF CMOS systems which often require multiple trial-and-error based Silicon validations, thereby incurring additional production costs. This dissertation proposes a low overhead technique which attempts to counter the detrimental effects of these variations, thereby improving both performance and yield of chips post fabrication in a systematic way. The key idea behind this approach is to dynamically sense the performance of the system, identify when a problem has occurred, and then actuate it back to its desired performance level through an intelligent on-chip optimization algorithm. We term this technique as self-healing drawing inspiration from nature's own way of healing the body against adverse environmental effects. To effectively demonstrate the efficacy of self-healing in CMOS systems, several representative examples are designed, fabricated, and measured against a variety of operating conditions.
We demonstrate a high-power mm-wave segmented power mixer array based transmitter architecture that is capable of generating high-speed and non-constant envelope modulations at higher efficiencies compared to existing conventional designs. We then incorporate several sensors and actuators into the design and demonstrate closed-loop healing against a wide variety of non-ideal operating conditions. We also demonstrate fully-integrated self-healing in the context of another mm-wave power amplifier, where measurements were performed across several chips, showing significant improvements in performance as well as reduced variability in the presence of process variations and load impedance mismatch, as well as catastrophic transistor failure. Finally, on the receiver side, a closed-loop self-healing phase synthesis scheme is demonstrated in conjunction with a wide-band voltage controlled oscillator to generate phase shifter local oscillator (LO) signals for a phased array receiver. The system is shown to heal against non-idealities in the LO signal generation and distribution, significantly reducing phase errors across a wide range of frequencies.
Resumo:
With the installation by the Pacific Electric Railway of a bus system in Pasadena to supplant most of its trolley lines, the problem of the comparison of the costs of the two systems naturally presented itself. The study here undertaken was originally started as just a comparison of the motor bus and Birney Safety Car, but as the work progressed it seemed advisable to include the trolley bus as well - a method of transportation that is comparatively new as far as development is concerned, but which seems to be finding increasing favor in the East.