689 resultados para Online Teaching, Staff Development, Online Pedagogies
Resumo:
BACKGROUND: The arterial pulse pressure variation induced by mechanical ventilation (Delta PP) has been shown to be a predictor of fluid responsiveness. Until now, Delta PP has had to be calculated offline (from a computer recording or a paper printing of the arterial pressure curve), or to be derived from specific cardiac output monitors, limiting the widespread use of this parameter. Recently, a method has been developed for the automatic calculation and real-time monitoring of Delta PP using standard bedside monitors. Whether this method is to predict reliable predictor of fluid responsiveness remains to be determined. METHODS: We conducted a prospective clinical study in 59 mechanically ventilated patients in the postoperative period of cardiac surgery. Patients studied were considered at low risk for complications related to fluid administration (pulmonary artery occlusion pressure <20 mm Hg, left ventricular ejection fraction >= 40%). All patients were instrumented with an arterial line and a pulmonary artery catheter. Cardiac filling pressures and cardiac output were measured before and after intravascular fluid administration (20 mL/kg of lactated Ringer`s solution over 20 min), whereas Delta PP was automatically calculated and continuously monitored. RESULTS: Fluid administration increased cardiac output by at least 15% in 39 patients (66% = responders). Before fluid administration, responders and nonresponders were comparable with regard to right atrial and pulmonary artery occlusion pressures. In contrast, Delta PP was significantly greater in responders than in nonresponders, (17% +/- 3% vs 9% +/- 2%, P < 0.001). The Delta PP cut-off value of 12% allowed identification of responders with a sensitivity of 97% and a specificity of 95%. CONCLUSION: Automatic real-time monitoring of Delta PP is possible using a standard bedside rnonitor and was found to be a reliable method to predict fluid responsiveness after cardiac surgery. Additional studies are needed to determine if this technique can be used to avoid the complications of fluid administration in high-risk patients.
Resumo:
Purpose To compare the process of myelination in the developing optic nerve (ON) of anaemic rats with the subsequent recovery after being fed an iron-recovery diet. Methods In this study, the morphometrical parameters in the ON were assessed by electron microscopy in Wistar rats that were on an iron-deficient diet for 32 days or for 21 days followed by 10 days on an iron-recovery diet. Qualitative and quantitative analyses were performed using representative electron ultramicrographs. Data were analysed by one-way analysis of variance (ANOVA). When differences were detected, comparisons were made using Tukey`s post hoc test (P<0.05 was considered to be significant). Results Qualitative analysis of the ONs in anaemic and recovered animals showed a higher rate of deformed axons and increased lamellar separation in the myelin sheath when compared with the respective control group. The ON of the anaemic group showed a reduced mean density of myelinated fibres when compared with the control group. The fibre area ratio, axon area ratio, and myelin area ratio of large axons/small axons in the ONs of the control group showed the highest values for the myelin areas, axon areas, and total fibre areas. The control group showed a significantly higher myelin sheath thickness when compared with the anaemic and recovered groups. Conclusions Our data indicate that iron is necessary for maintenance of the ON cell structure, and that morphological damage from iron deficiency is not easily reverted by iron repletion. Eye (2010) 24, 901-908; doi:10.1038/eye.2009.205; published online 14 August 2009
Resumo:
Genetic and environmental sources of covariation among the P3(00) and online performance elicited in a delayed-response working memory task, and psychometric IQ assessed by the multidimensional aptitude battery, were examined in an adolescent twin sample. An association between frontal P3 latency and task performance (phenotypic r = -0.33; genotypic r = -0.49) was indicated, with genes (i.e. twin status) accounting for a large part of the covariation ( > 70%). In contrast, genes influencing P3 amplitude mediated only a small part (2%) of the total genetic variation in task performance. While task performance mediated 15% of the total genetic variation in IQ (phenotypic r = 0.22; genotypic r = 0.39) there was no association between P3 latency and IQ or P3 amplitude with IQ. The findings provide some insight into the inter-relationships among psychophysiological, performance and psychometric measures of cognitive ability, and provide support for a levels-of-processing genetic model of cognition where genes act on specific sub-components of cognitive processes.
Resumo:
Fault detection and isolation (FDI) are important steps in the monitoring and supervision of industrial processes. Biological wastewater treatment (WWT) plants are difficult to model, and hence to monitor, because of the complexity of the biological reactions and because plant influent and disturbances are highly variable and/or unmeasured. Multivariate statistical models have been developed for a wide variety of situations over the past few decades, proving successful in many applications. In this paper we develop a new monitoring algorithm based on Principal Components Analysis (PCA). It can be seen equivalently as making Multiscale PCA (MSPCA) adaptive, or as a multiscale decomposition of adaptive PCA. Adaptive Multiscale PCA (AdMSPCA) exploits the changing multivariate relationships between variables at different time-scales. Adaptation of scale PCA models over time permits them to follow the evolution of the process, inputs or disturbances. Performance of AdMSPCA and adaptive PCA on a real WWT data set is compared and contrasted. The most significant difference observed was the ability of AdMSPCA to adapt to a much wider range of changes. This was mainly due to the flexibility afforded by allowing each scale model to adapt whenever it did not signal an abnormal event at that scale. Relative detection speeds were examined only summarily, but seemed to depend on the characteristics of the faults/disturbances. The results of the algorithms were similar for sudden changes, but AdMSPCA appeared more sensitive to slower changes.
Resumo:
0na eg rcarmitimcaal tfieca tcuorem opfr ethhee nospieornat iodneafli cdietf i(nAitiCoDn )o ft hthaet frequently co-occurs with Broca’s aphasia is above-chance performance on well-formedness judgment tasks for many syntactic constructions, but impaired performance where syntactic binding of traces to their antecedents occurs. However, the methodologies used to establish this aspect of the performance profile of the ACD have been predominantly offline. Offline well-formedness tasks entail extralinguistic processing (e.g. perception, attention, short-term memory, conscious reflection) in varying amounts and the influence of such processes on parsing mechanisms is yet to be fully established. In order to (a) further understand the role of extra-linguistic processing on parsing, and (b) gain a more direct insight into the online nature of parsing in Broca’s aphasia, 8 subjects underwent a series of wellformedness judgment investigations using both offline and online test batteries. The sentence types and error types used were motivated by three current theories about the nature of the ACD, namely, the Trace-Based Account (Grodzinsky, 2000), the Mapping Hypothesis (Linebarger et al., 1983) and Capacity proposals (e.g. Frazier & Friederici, 1991). The results from the present investigation speak directly to the three aforementioned theories and also demonstrate the important role that extralinguistic processing plays during offline assessment. The clinical implications of the different outcomes from the offline vs. online tasks are also discussed.