960 resultados para Microchip Capillary-Electrophoresis
Resumo:
A mode of capillary electrochromatography for separation of ionic compounds driven by electrophoretic mobility on a neutrally hydrophobic monolithic column was developed. The monolithic column was prepared from the in situ copolymerization of lauryl methacrylate and ethylene dimethacrylate to form a C-12 hydrophobic stationary phase. It was found that EOF in this hydrophobic monolithic column was very poor, even the pH value of mobile phase at 8.0. The peptides at acidic buffer were separated on the basis of their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase; therefore, different separation selectivity can be obtained in CEC from that in capillary zone electrophoresis (CZE). Separation of peptides has been realized with high column efficiency (up to 150 000 plates/meter) and good reproducibility (migration time with RSD < 0.5%), and all of the peptides, including some basic peptides, showed good peak symmetry. Effects of the mobile phase compositions on the retention of peptides at low pH have been investigated in a hydrophobic capillary monolithic column. The significant difference in selectivity of peptides in CZE and CEC has been observed. Some peptide isomers that cannot be separated by CZE have been successfully separated on the capillary monolithic column in this mode with the same buffer used.
Resumo:
This review surveys the recent progress in the adsorbed stationary phases for capillary electrochromatography (CEC). Adsorption-based methods for preparation of stationary phase are novel approaches in CEC, which allow rapid and facile preparing stationary phases with desirable selectivity onto an open-tubular fused-silica capillary, a baresilica or ion-exchange packed column or a monolithic silica or polymer column. A variety of adsorbing agents have been developed as adsorbed stationary phases, including ionic long-chain surfactant, protein, peptide, amino acid, charged cyclodextrin (CD), basic compound, aliphatic ionene, and ion-exchange latex particle. The adsorbed stationary phases have been applied to separation of neutral, basic and acidic organic compounds, inorganic anions and enantiomers. They have also been applied to on-line sample concentration, fast separation and study of the competitive binding of enantiomers with protein.
Resumo:
A simultaneous electrochemiluminescence (ECL) and electrochemical (EC) detection scheme for NACE was presented for fast analysis of tertiary amines. Both ECL and EC signals were generated at the same Pt electrode. Triethylamine (TEA), tripropylamine (TPrA), chlorpromazine, promethazine, and dioxopromethazine (DPZ) were selected to validate NACE-ECL/EC dual detection strategy. The linear ranges for TEA and TPrA were 0.01-500 and 0.01-10 mu M with the detection limits of 8.0 and 5.0 nM (S/N=3), respectively. The RSDs (n = 6) of the migration time and the ECL intensity for 1 mu M TEA and 0.5 mu M TPrA were 0.1 and 2.8%, and 0.2 and 1.8% with theoretical plate numbers of 180 000 and 700 000 per meter, respectively. These two analytes could be separated within 92 s and the Pt electrode did not need reactivation during the experiments.
Resumo:
A procedure is described for the preparation of a tubular electrode by chemical deposition of platinum at the end of a fused-silica capillary. The properties of the electrode were tested under liquid chromatographic conditions, demonstrating that both the static and the dynamic behaviour of the detection system satisfy the requirements of capillary chromatographic separations and compare well with a wall-jet amperometric system and with UV photometric detection. The detection system described is easy to prepare and does not require any time-consuming positioning of the electrode system as it is integrated into the separation part of the apparatus. (C) 1998 Elsevier Science B.V.
Resumo:
Influences of seven organic modifiers, including urea, methanol (MeOH), dioxane (DIO), tetrahydrofuran (THF), acetonitrile (ACN), 1-propanol (1-PrOH) and 2-propanol (2-PrOH), on the solute retention and the electrokinetic migrations in micellar electrokinetic capillary chromatography (MEKC) are investigated with sodium dodecyl sulfate (SDS) micelle as pseudostationary phase. It is observed that in the limited concentration ranges used in the MEKC systems the effect of organic modifier concentration on the retention can be described by the equation logk'=logk'(w)-SC for most binary aqueous-organic buffer, but deviations from this retention equation are observed at ACN and particularly THF as organic modifiers. With parameter S as a measure of the elutropic strength, the elutropic strength of the organic modifiers is found to follow a general order urea
Resumo:
The migration mechanism of ionizable compounds in capillary electrochromatography (CEC) is more complicated than in high performance liquid chromatography (HPLC) due to the involvement of electrophoresis and the second chemical equilibrium. The separation mechanism of ionizable compounds in CEC has been studied theoretically. The electrochromatographic capacity factors of ions (k *) in CEC and in the pressurized CEC are derived by phenomenological approach. The influence of pH, voltage, pressure on k* is discussed. in addition, the k * of weak acid and weak base are derived based on acid-base equilibrium and the influence of pH on k * is studied theoretically.
Resumo:
A new set-up was constructed for capillary isoelectric focusing (CIEF) involving a sampling capillary as a bypass fixed to the separation capillary. Sample solutions were subjected to a previously established pH gradient from the sample capillary. Besides performing conventional CIEF, the separation of ampholytic compounds with isoelectric points (p/s) beyond the pH gradient was carried out on this system. This method was termed as pH gradient driven electrophoresis (PGDE) and the basic mathematical expressions were derived to express the dynamic fundamentals. Proteins such as lysozyme, cytochrome C, and pepsin with p/s higher than 10 or below 3 were separated in a pH gradient provided by Pharmalyte (pH 3-10). Finally, this protocol convincingly exhibited its potential in the separation of a solution of chicken egg white.
Resumo:
Pressurized capillary electrochromatography (pCEC) and electrospray ionization-mass spectrometry (ESI-MS) have been hyphenated for protein analysis. Taken cytochrome c, lysozyme, and insulin as samples, the limits of detection (LODs) for absolute concentrations are 10(-11) mol (signal-to-noise ratio S/N = 3) with relative standard deviations (RSDs) of retention time and peak area, respectively, of less than 1.7% and 4.8%. In order to improve the detection sensitivity, on-line concentration by field-enhanced sample-stacking effect and chromatographic zone-sharpening effect has been developed, and parameters affecting separation and detection, such as pH and electrolyte concentration in the mobile phase, separation voltage, as well as enrichment voltage and time, have been studied systematically. Under the optimized conditions, the LODs of the three proteins could be decreased up to 100-fold. In addition, the feasibility of such techniques has been further demonstrated by the analysis of modified insulins at a concentration of 20 mu g/mL.
Resumo:
A novel hybrid organic-inorganic silica-based monolithic column possessing phenyl ligands for reversed-phase (RP) capillary electrochromatography (CEC) is described. The monolithic stationary phase was prepared by in situ co-condensation of tetraethoxysilane (TEOS) with phenyltriethoxysilane (PTES) via a two-step catalytic sol-gel procedure to introduce phenyl groups distributed throughout the silica matrix for chromatographic interaction. The hydrolysis and condensation reactions of precursors were chemically controlled through pH variation by adding hydrochloric acid and dodecylamine, respectively. The structural property of the monolithic column can be easily tailored through adjusting the composition of starting sol solution. The effect of PTES/TEOS ratios on the morphology of the created stationary phases was investigated. A variety of neutral and basic analytes were used to evaluate the column performance. The CEC columns exhibited typical RP chromatographic retention mechanism for neutral compounds and had improved peak shape for basic solutes.