990 resultados para Microarray technology
Resumo:
Report on a review of selected application controls over the Iowa State University of Science and Technology Facilities Planning and Management - Facilities Administrative Management Information System for the period of April 18, 2011 through May 16, 2011
Resumo:
Report on Iowa State University of Science and Technology, Ames, Iowa, for the year ended June 30, 2011
Resumo:
RÉSUMÉ L'Organisation Mondiale de la Santé (OMS) recommande d'administrer l'oxygène par concentrateurs dans les pays en voie de développement (PVD), les cylindres posant des problèmes logistiques et financiers trop importants. Cette technologie a été proposée aux enfants d'un hôpital sénégalais (Ndioum) qui présentaient les critères d'oxygénation de l'OMS. Les bénéfices cliniques et financiers ont été majeurs. En revanche, les connaissances des soignants sur les diverses techniques d'administration d'oxygène ainsi que les prestations du service de maintenance étaient insuffisantes. L'implantation de concentrateurs doit être encouragée dans les PVD, mais doit respecter une stratégie englobant enseignement, maintenance et suivi de l'opération. Diverses actions correctrices ont été entreprises à Ndioum où plusieurs concentrateurs fonctionnent désormais régulièrement. Summary: The World Health Organisation (WHO) recommends supplying oxygen in developing countries by concentra¬tors because cylinders pose considerable logistic and financial problems. This technology was employed to treat children in a hospital in Ndioum, Senegal, who met the WHO oxygenation criteria. There were clear clinical and financial benefits, but neither the nurses' knowledge of the various techniques of oxygen supply nor the maintenance service were satisfactory. The use of concentra¬tors should be encouraged in developing countries. A strategy including technical training, maintenance and monitoring should be adopted. Corrective actions were undertaken in Ndioum, and several concentrators are now being used on a regular basis.
Resumo:
New technologies in prostate cancer are attempting to change the current prostate cancer pathway by aiming to reduce harms while maintaining the benefits associated with screening, diagnosis, and treatment. In this article, we discuss the optimal evaluation that new technologies should undergo to provide level 1 evidence typically required to change the practice. With this in mind, we focus on feasible and pragmatic trials that could be delivered in a timely fashion by many centers while retaining primary outcomes that focus on clinically meaningful outcomes.
Resumo:
The function of DNA-binding proteins is controlled not just by their abundance, but mainly at the level of their activity in terms of their interactions with DNA and protein targets. Moreover, the affinity of such transcription factors to their target sequences is often controlled by co-factors and/or modifications that are not easily assessed from biological samples. Here, we describe a scalable method for monitoring protein-DNA interactions on a microarray surface. This approach was designed to determine the DNA-binding activity of proteins in crude cell extracts, complementing conventional expression profiling arrays. Enzymatic labeling of DNA enables direct normalization of the protein binding to the microarray, allowing the estimation of relative binding affinities. Using DNA sequences covering a range of affinities, we show that the new microarray-based method yields binding strength estimates similar to low-throughput gel mobility-shift assays. The microarray is also of high sensitivity, as it allows the detection of a rare DNA-binding protein from breast cancer cells, the human tumor suppressor AP-2. This approach thus mediates precise and robust assessment of the activity of DNA-binding proteins and takes present DNA-binding assays to a high throughput level.
Resumo:
The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.
Resumo:
Report on a review of selected general and application controls over the Iowa State University of Science and Technology Room and Board System for the period of April 9, 2012 through May 1, 2012
Resumo:
Audit report of Iowa State University of Science and Technology as of and for the year ended June 30, 2012
Resumo:
Technology News is a newsletter produced by the Iowa Department of Transportation to provide information to the transportation specialist in Iowa's cities and counties. Technology News is one of CTRE's primary avenues for exchanging transportation-related information with local agencies. The bimonthly newsletter gives an up-to-date look to the up-to-date information our 2,500+ readers have grown to expect.
Resumo:
Technology News is a newsletter produced by the Iowa Department of Transportation to provide information to the transportation specialist in Iowa's cities and counties. Technology News is one of CTRE's primary avenues for exchanging transportation-related information with local agencies. The bimonthly newsletter gives an up-to-date look to the up-to-date information our 2,500+ readers have grown to expect.