923 resultados para Maxillofacial prosthesis implantation
Resumo:
Male coleoid cephalopods produce spermatophores that can attach autonomously on the female's body during a complex process of evagination called the spermatophoric reaction, during which the ejaculatory apparatus and spiral filament of the spermatophore are everted and exposed to the external milieu. In some deepwater cephalopods, the reaction leads to the intradermal implantation of the spermatophore, a hitherto enigmatic phenomenon. The present study builds upon several lines of evidence to propose that spermatophore implantation is probably achieved through the combination of (1) an evaginating-tube mechanism performed by the everting ejaculatory apparatus and (2) the anchorage provided by the spiral filament's stellate particles. The proposed theoretical model assumes that, as it is exposed to the external milieu, each whorl of the spiral filament anchors to the surrounding tissue by means of its sharp stellate particles. As the ejaculatory apparatus tip continues evaginating, it grows in diameter and stretches lengthwise, enlarging the diameter of the whorl and propelling it, consequently tearing and pushing the anchored tissue outward and backward, and opening space for the next whorl to attach. After the ejaculatory apparatus has been everted and has perforated tissue, the cement body is extruded, possibly aiding in final attachment, and the sperm mass comes to lie inside the female tissue, encompassed by the everted ejaculatory apparatus tube. It is proposed that this unique, efficient spermatophore attachment mechanism possibly evolved in intimate relationship with the adoption of an active mode of life by coleoids. The possible roles of predation pressure and sperm competition in the evolution of this mechanism are also discussed. (c) 2012 The Linnean Society of London, Biological Journal of the Linnean Society, 2012, 105, 711726.
Resumo:
The purpose of this study was to warn the dental community about a possible problem in function with partial implant-supported prostheses used for long periods. The misalignment between natural teeth and the implant-supported prosthesis on teeth 11 and 12, observed in a 14-year clinical follow-up, illustrates the fact. The metal-ceramic crowns were placed in 1995 after a rigorous occlusal adjustment. Evaluations were made at 4, 6, 9, and 14 years, when it was noticed that the restorations were positioned palatally and extruded in comparison with the natural teeth. After 9 years, a greater discrepancy was noticed, with anterior occlusion and esthetic changes. The possible causes have been discussed: occlusal problems, parafunctional habits, and natural movement. The first 2 options were discarded after clinical analysis and diagnosis. Therefore, the natural movement probably deriving from an interaction of mechanical and genetic factors might have been the cause. The implants do not have periodontal ligaments but rather ankylosis, so they do not suffer those movements. This case emphasizes the need to inform patients that implants can last more than 10 years in function, but this is not the case with restorations, which lose function and esthetics and must be replaced.
Resumo:
This paper presents the treatment protocol of maxillofacial surgery in the rehabilitation process of cleft lip and palate patients adopted at HRAC-USP. Maxillofacial surgeons are responsible for the accomplishment of two main procedures, alveolar bone graft surgery and orthognathic surgery. The primary objective of alveolar bone graft is to provide bone tissue for the cleft site and then allow orthodontic movements for the establishment of an an adequate occlusion. When performed before the eruption of the maxillary permanent canine, it presents high rates of success. Orthognathic surgery aims at correcting maxillomandibular discrepancies, especially anteroposterior maxillary deficiencies, commonly observed in cleft lip and palate patients, for the achievement of a functional occlusion combined with a balanced face.
Resumo:
We describe work in which gold nanoparticles were formed in diamond-like carbon (DLC), thereby generating a Au-DLC nanocomposite. A high-quality, hydrogen-free DLC thin film was formed by filtered vacuum arc plasma deposition, into which gold nanoparticles were introduced using two different methods. The first method was gold ion implantation into the DLC film at a number of decreasing ion energies, distributing the gold over a controllable depth range within the DLC. The second method was co-deposition of gold and carbon, using two separate vacuum arc plasma guns with suitably interleaved repetitive pulsing. Transmission electron microscope images show that the size of the gold nanoparticles obtained by ion implantation is 3-5 nm. For the Au-DLC composite obtained by co-deposition, there were two different nanoparticle sizes, most about 2 nm with some 6-7 nm. Raman spectroscopy indicates that the implanted sample contains a smaller fraction of sp(3) bonding for the DLC, demonstrating that some sp(3) bonds are destroyed by the gold implantation. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4757029]
Resumo:
This manuscript reports on the fabrication of plasmonic substrates using cathodic arc plasma ion implantation, in addition to their performance as SERS substrates. The technique allows for the incorporation of a wide layer of metallic nanoparticles into a polymer matrix, such as PMMA. The ability to pattern different structures using the PMMA matrix is one of the main advantages of the fabrication method. This opens up new possibilities for obtaining tailored substrates with enhanced performance for SERS and other surface-enhanced spectroscopies, as well as for exploring the basic physics of patterned metal nanostructures. The architecture of the SERS-active substrate was varied using three adsorption strategies for incorporating a laser dye (rhodamine): alongside the nanoparticles into the polymer matrix, during the polymer cure and within nanoholes lithographed on the polymer. As a proof-of-concept, we obtained the SERS spectra of rhodamine for the three types of substrates. The hypothesis of incorporation of rhodamine molecules into the polymer matrix during the cathodic arc plasma ion implantation was supported by FDTD (Finite-Difference Time-Domain) simulations. In the case of arrays of nanoholes, rhodamine molecules could be adsorbed directly on the gold surface, then yielding a well-resolved SERS spectrum for a small amount of analyte owing to the short-range interactions and the large longitudinal field component inside the nanoholes. The results shown here demonstrate that the approach based on ion implantation can be adapted to produce reproducible tailored substrates for SERS and other surface-enhanced spectroscopies.
Resumo:
PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C (6.43 +/- 3.24 mu m) when compared to Groups A (16.50 +/- 7.55 mu m) and B (16.27 +/- 1.71 mu m) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66 +/- 14.30 mu m; Group B, 39.4.8 +/- 12.03 mu m; Group C, 23.13 +/- 8.24 mu m) (P<.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. [J Adv Prosthodont 2012;4:89-92]
Resumo:
This study was conducted to investigate the relationship among radiographic features observed on panoramic radiographs of sickle cell disease patients and analyze their relationship with history of systemic severity of the disease. Panoramic radiographs of 71 subjects with sickle cell disease were evaluated for the presence of the following radiographic bony alterations: radiopaque areas, increased spacing of bony trabeculae, horizontal arrangement of bony trabeculae and corticalization of mandibular canal. History of clinical systemic severity was assessed through direct questioning about the frequency of vaso-occlusive crisis, history of stroke, clinical jaundice, femur head necrosis, and leg ulceration. Chi-square or Fisher's exact test were applied in order to analyze possible associations between radiographic features and history of complications, with < 0.05 significance level. Increased spacing of bony trabeculae was statistically associated with absence of corticalization of mandibular canal ( < 0.01) and horizontal arrangement of bony trabeculae ( = 0.04). Statistically significant associations were demonstrated between history of clinical jaundice and presence of increased spacing of bony trabeculae ( = 0.02) and between history of stroke and presence of horizontal arrangement of bony trabeculae ( = 0.04). Based on the results of the current study, maxillofacial radiographic features may be associated with clinical parameters of systemic complications in sickle cell disease patients. The relationship between radiographic features and history of complications associated with clinical severity of sickle cell disease has not been demonstrated in the literature. Acknowledgment of such possible association may help establish prognosis and influence clinical treatment of systemic and oral complications.
Resumo:
Objectives: To evaluate the colour stability of paints used for ocular prosthesis iris painting submitted for accelerated artificial ageing (AAA). Materials and methods: Forty specimens of acrylic resin for sclera (16 x 2 mm) were made and separated into eight groups (n = 10) according to the type of paint (gouache, GP; oil, OP; acrylic AP; and composite resin for characterisation, CR) and the colours used (blue/brown). After drying (72 h), a new layer of colourless acrylic resin was applied and the initial colour readout was performed (Spectrophotometer PCB 6807). New colour readouts were performed after AAA, and Delta E was calculated. Results: Statistical analysis (two-way ANOVA-Bonferroni, p < 0.05) demonstrated that the brown colour showed lower Delta E means in comparison with the blue colour, with statistically significant difference for AP only. Blue colour showed no statistically significant difference with regard to the type of paint used. Brown AP showed lower Delta E than the other groups, with significant difference for OP and GP. GP showed greater alteration in Delta E for the brown colour, being statistically similar only to OP. Conclusions: Only the AP group for brown pigment shows clinically acceptable values for colour stability after AAA.
Resumo:
Objective: The aim of this study was to analyze the criteria employed for the requesting of preoperative tests among maxillofacial surgeons. Materials and methods: Thirty maxillofacial surgeons working in Aracaju (Brazil) received a questionnaire to fill out. The study inquired about the practice of requesting preoperative tests for healthy patients scheduled to undergo elective surgery. Results: Most of the surgeons interviewed requested tests that are not recommended for the case in question. The highest frequency of requests was a complete blood count, coagulation test, blood glucose test and chest radiograph. Conclusion: The absence of strict rules for the requesting of preoperative tests causes uncertainty and a lack of criteria regarding pre-surgical conduct. It was not possible to clearly define the criteria used by surgeons for requesting such tests, as the clinical characteristics of the hypothetical case presented suggest a smaller number of tests. (C) 2011 European Association for Cranio-Maxillo-Facial Surgery.
Resumo:
Purpose: Insertion of totally implantable catheters via deep vessels that drain into the superior vena cava results in a lower incidence of venous thrombosis and infection as compared to catheters inserted into femoral and arm veins. Superior vena cava obstruction and inadequacy of the thoracic wall are conditions that prevent reservoir implantation in the chest wall. In this article, we describe a technical innovation that enables the pocket to be fixed in the arm while still allowing access to be achieved via the internal jugular vein. Method: The procedure reported maintains the use of the internal jugular vein for access even when the patient's chest is not suited for reservoir implantation, which is localized in the arm. Results: The procedure was successful and no complications occurred. The position of the catheter tip did not alter with arm movement. Conclusion: The implantation of a port reservoir in the arm following venous access via the internal jugular vein is both safe and convenient.
Resumo:
Introduction: The aim of this study was to assess the effect of nitrogen ion implantation on the flexibility of rotary nickel-titanium (NiTi) instruments as measured by the load required to bend implanted and nonimplanted instruments at a 30 degrees angle. Methods: Thirty K3 files, size #40, 0.02 taper and 25-mm length, were allocated into 2 groups as follows: group A, 15 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), voltage 200 KeV, current density 1 mu A/cm(2), temperature 130 degrees C, and vacuum conditions of 10 x 10(-6) mm Hg for 6 hours; and group B, 15 nonimplanted files. One extra file was used for process control. All instruments were subjected to bend testing on a modified troptometer, with measurement of the load required for flexure to an angle of 30 degrees. The Mann-Whitney U test was used for statistical analysis. Findings with P <.05 were considered significant. Results: The mean load required to bend instruments at a 30 degrees angle was 376.26 g for implanted instruments and 383.78 g for nonimplanted instruments. The difference was not statistically significant. Conclusions: Our findings show that nitrogen ion implantation has no appreciable effect on the flexibility of NiTi instruments. (J Endod 2012;38:673-675)
Resumo:
Objectives: To report the results of cochlear implantation via the middle fossa approach in 4 patients, discuss the complications, and present a detailed description of the programming specifications in these cases. Study Design: Retrospective case review. Setting: Tertiary-care referral center with a well-established cochlear implant program. Patients: Four patients with bilateral canal wall down mastoid cavities who underwent the middle fossa approach for cochlear implantation. Interventions: Cochlear implantation and subsequent rehabilitation. A middle fossa approach with cochleostomy was successfully performed on the most superficial part of the apical turn in 4 patients. A Nucleus 24 cochlear implant system was used in 3 patients and a MED-EL Sonata Medium device in 1 patient. The single electrode array was inserted through a cochleostomy from the cochlear apex and occupied the apical, middle, and basal turns. Telemetry and intraoperative impedance recordings were performed at the end of surgery. A CT scan of the temporal bones was performed to document electrode insertion for all of the patients. Main Outcome Measures: Complications, hearing thresholds, and speech perception outcomes were evaluated. Results: Neural response telemetry showed present responses in all but 1 patient, who demonstrated facial nerve stimulation during the test. Open-set speech perception varied from 30% to 100%, despite the frequency allocation order of the MAP. Conclusion: Cochlear implantation via the middle cranial fossa is a safe approach, although it is a challenging procedure, even for experienced surgeons.
Resumo:
Aims: The long-term clinical performance of drug-eluting stents (DES) coated with biodegradable polymers is poorly known. Methods and results: A total of 274 coronary patients were randomly allocated to paclitaxel-eluting stents, sirolimus-eluting stents, or bare metal stems (2:2:1 ratio). The two DES used the same biodegradable polymers and were identical except for the drug. At three years, the pooled DES population had similar rates of cardiac death or myocardial infarction (9.0% vs. 7.1; p=0.6), but lower risk of repeat interventions (10.0% vs. 29.9%; p<0.01) than controls with bare stents. The cumulative 3-year incidence of definite or probable stent thrombosis in the pooled DES group was 2.3% (first year: 1.8%; second year: 0.4%; third year: zero). There were no significant differences in outcomes between paclitaxel- and sirolimus-eluting stents. Conclusions: The biodegradable-polymer coated DES releasing either paclitaxel or sirolimus were effective in reducing the 3-year rate of re-interventions.
Resumo:
Cochlear implantation is a safe and reliable method for auditory restoration in patients with severe to profound hearing loss. Objective: To describe the surgical complications of cochlear implantation. Materials and Methods: Information from 591 consecutive multichannel cochlear implant surgeries were retrospectively analyzed. All patients were followed-up for at least one year. Forty-one patients were excluded because of missing data, follow-up loss or middle fossa approach. Results: Of 550 cochlear implantation analyzed, 341 were performed in children or adolescents, and 209 in adults. The mean hearing loss time was 6.3 +/- 6.7 years for prelingual loss and 12.1 +/- 11.6 years for postlingual. Mean follow-up was 3.9 +/- 2.8 years. Major complications occurred in 8.9% and minor in 7.8%. Problems during electrode insertion (3.8%) were the most frequent major complication followed by flap dehiscence (1.4%). Temporary facial palsy (2.2%), canal-wall lesion (2.2%) and tympanic membrane lesion (1.8%) were the more frequent minor complications. No death occurred. Conclusion: There was a low rate of surgical complications, most of them been successfully managed. These results confirm that cochlear implant is a safe surgery and most surgical complications can be managed with conservative measures or minimal intervention.