961 resultados para LEACH Mobile Enhanced protocol
Resumo:
In this paper, we study how access pricing affects network competition when subscription demand is elastic and each network uses non-linear prices and can apply termination-based price discrimination. In the case of a fixed per minute termination charge, we find that a reduction of the termination charge below cost has two opposing effects: it softens competition but helps to internalize network externalities. The former reduces mobile penetration while the latter boosts it. We find that firms always prefer termination charge below cost for either motive while the regulator prefers termination below cost only when this boosts penetration. Next, we consider the retail benchmarking approach (Jeon and Hurkens, 2008) that determines termination charges as a function of retail prices and show that this approach allows the regulator to increase penetration without distorting call volumes.
Resumo:
A taxonomical and ecological study was made on 264 samples of 12 species of ectoparasite ixodides collected on wild mammals from several natural regions of Paraná state, Brazil. These species of ticks as their hosts are listed by their identified evolutive forms and capture locations. A review of the early studies on the Ixodida from South Brazil is made considering the frequency of the parasite species on each host concerning the geographic distribution of such species. This paper is a contribution to the knowledge of the Ixodidae ectoparasites species of wild mammals in Brazil.
Resumo:
Protocol per autenticar a persones que sol·liciten un servei o producte en un web mitjançant un proveïdor d'identitats amb el DNI-E. El proveïdor d'identitats garanteix als proveïdors de serveis que les persones amb qui tracten són qui diuen ser i proporciona a més una reputació associada a cada persona. Aquesta comunicació es fa amb un servei web que prèvia autenticació del proveïdor de servei podrà realitzar les diferents peticions d'autenticitat i de reputació dels seus clients. Donat que es tracten amb dades personals, durant el protocol es protegeix en tot moment l'autèntica identitat de cada persona per tal de que pugui mantenir el seu anonimat.
Resumo:
BACKGROUND: Contrast-enhanced ultrasonography (CEUS) is a novel imaging technique that is safe and applicable on the bedside. Recent developments seem to enable CEUS to quantify organ perfusion. We performed an exploratory study to determine the ability of CEUS to detect changes in renal perfusion and to correlate them with effective renal plasma flow. METHODS: CEUS with destruction-refilling sequences was studied in 10 healthy subjects, at baseline and during infusion of angiotensin II (AngII) at low (1 ng/kg/min) and high dose (3 ng/kg/min) and 1 h after oral captopril (50 mg). Perfusion index (PI) was obtained and compared with the effective renal plasma flow (ERPF) obtained by parallel para-aminohippurate (PAH) clearance. RESULTS: Median PI decreased from 188.6 (baseline) to 100.4 with low-dose AngII (-47%; P < 0.02) and to 66.1 with high-dose AngII (-65%; P < 0.01) but increased to 254.7 with captopril (+35%; P > 0.2). These changes parallelled those observed with ERPF, which changed from a median of 672.1 mL/min (baseline) to 572.3 (low-dose AngII, -15%, P < 0.05) and to 427.2 (high-dose AngII, -36%, P < 0.001) and finally 697.1 (captopril, +4%, P < 0.02). CONCLUSIONS: This study demonstrates that CEUS is able to detect changes in human renal cortical microcirculation as induced by AngII infusion and/or captopril administration. The changes in perfusion indices parallel those in ERPF as obtained by PAH clearance.
Resumo:
Artificial antigen-presenting cells (aAPC) are widely used for both clinical and basic research applications, as cell-based or bead-based scaffolds, combining immune synapse components of interest. Adequate and controlled preparation of aAPCs is crucial for subsequent immunoassays. We reveal that certain proteins such as activatory anti-CD3 antibody can be out-competed by other proteins (e.g. inhibitory receptor ligands such as PDL1:Fc) during the coating of aAPC beads, under the usually performed coating procedures. This may be misleading, as we found that decreased CD8 T cell activity was not due to inhibitory receptor triggering but rather because of unexpectedly low anti-CD3 antibody density on the beads upon co-incubation with inhibitory receptor ligands. We propose an optimized protocol, and emphasize the need to quality-control the coating of proteins on aAPC beads prior to their use in immunoassays.
Resumo:
ABSTRACT: BACKGROUND: There is no recommendation to screen ferritin level in blood donors, even though several studies have noted the high prevalence of iron deficiency after blood donation, particularly among menstruating females. Furthermore, some clinical trials have shown that non-anaemic women with unexplained fatigue may benefit from iron supplementation. Our objective is to determine the clinical effect of iron supplementation on fatigue in female blood donors without anaemia, but with a mean serum ferritin </= 30 ng/ml. METHODS/DESIGN: In a double blind randomised controlled trial, we will measure blood count and ferritin level of women under age 50 yr, who donate blood to the University Hospital of Lausanne Blood Transfusion Department, at the time of the donation and after 1 week. One hundred and forty donors with a ferritin level </= 30 ng/ml and haemoglobin level >/= 120 g/l (non-anaemic) a week after the donation will be included in the study and randomised. A one-month course of oral ferrous sulphate (80 mg/day of elemental iron) will be introduced vs. placebo. Self-reported fatigue will be measured using a visual analogue scale. Secondary outcomes are: score of fatigue (Fatigue Severity Scale), maximal aerobic power (Chester Step Test), quality of life (SF-12), and mood disorders (Prime-MD). Haemoglobin and ferritin concentration will be monitored before and after the intervention. DISCUSSION: Iron deficiency is a potential problem for all blood donors, especially menstruating women. To our knowledge, no other intervention study has yet evaluated the impact of iron supplementation on subjective symptoms after a blood donation. TRIAL REGISTRATION: NCT00689793.
Resumo:
We re-examine the literature on mobile termination in the presence of network externalities. Externalities arise when firms discriminate between on- and off-net calls or when subscription demand is elastic. This literature predicts that profit decreases and consumer surplus increases in termination charge in a neighborhood of termination cost. This creates a puzzle since in reality we see regulators worldwide pushing termination rates down while being opposed by network operators. We show that this puzzle is resolved when consumers' expectations are assumed passive but required to be fulfilled in equilibrium (as defined by Katz and Shapiro, AER 1985), instead of being rationally responsive to non-equilibrium prices, as assumed until now.
Resumo:
The objectives of the present study were to optimize the protocol of mouse immunization with Paracoccidioides brasiliensis antigens (Rifkind's protocol) and to test the modulation effect of cyclophosphamide (Cy) on the delayed hypersensitivity response (DHR) of immunized animals. Experiments were carried out using one to four immunizing doses of either crude particulate P. brasiliensis antigen or yeast-cell antigen, followed by DHR test four or seven days after the last immunizing dose. The data demonstrated that an immunizing dose already elicited response; higher DHR indices were obtained with two or three immunizing doses; there were no differences between DHR indices of animals challenged four or seven days after the last dose. Overall the inoculation of two or three doses of the yeast-cell antigen, which is easier to prepare, and DHR test at day 4 simplify the original Rifkind's immunization protocol and shorten the duration of the experiments. The modulation effect of Cy on DHR was assayed with administration of 2.5, 20 and 100 mg/kg weight at seven day intervals starting from day 4 prior to the first immunizing dose. Only the treatment with 2.5 mg Cy increased the DHR indices. Treatment with 100 mg Cy inhibited the DHR, whereas 20 mg Cy did not affect the DHR indices. Results suggest an immunostimulating effect of low dose of Cy on the DHR of mice immunized with P. brasiliensis antigens.
Resumo:
BACKGROUND: Chest pain is a common complaint in primary care, with coronary heart disease (CHD) being the most concerning of many potential causes. Systematic reviews on the sensitivity and specificity of symptoms and signs summarize the evidence about which of them are most useful in making a diagnosis. Previous meta-analyses are dominated by studies of patients referred to specialists. Moreover, as the analysis is typically based on study-level data, the statistical analyses in these reviews are limited while meta-analyses based on individual patient data can provide additional information. Our patient-level meta-analysis has three unique aims. First, we strive to determine the diagnostic accuracy of symptoms and signs for myocardial ischemia in primary care. Second, we investigate associations between study- or patient-level characteristics and measures of diagnostic accuracy. Third, we aim to validate existing clinical prediction rules for diagnosing myocardial ischemia in primary care. This article describes the methods of our study and six prospective studies of primary care patients with chest pain. Later articles will describe the main results. METHODS/DESIGN: We will conduct a systematic review and IPD meta-analysis of studies evaluating the diagnostic accuracy of symptoms and signs for diagnosing coronary heart disease in primary care. We will perform bivariate analyses to determine the sensitivity, specificity and likelihood ratios of individual symptoms and signs and multivariate analyses to explore the diagnostic value of an optimal combination of all symptoms and signs based on all data of all studies. We will validate existing clinical prediction rules from each of the included studies by calculating measures of diagnostic accuracy separately by study. DISCUSSION: Our study will face several methodological challenges. First, the number of studies will be limited. Second, the investigators of original studies defined some outcomes and predictors differently. Third, the studies did not collect the same standard clinical data set. Fourth, missing data, varying from partly missing to fully missing, will have to be dealt with.Despite these limitations, we aim to summarize the available evidence regarding the diagnostic accuracy of symptoms and signs for diagnosing CHD in patients presenting with chest pain in primary care. REVIEW REGISTRATION: Centre for Reviews and Dissemination (University of York): CRD42011001170.
Resumo:
Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.
Resumo:
Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.
Resumo:
En aquest projecte s’ha treballat en l’entorn PROSES, on aeroports i avions de l’espai aeri són mules de transport sobre una xarxa DTN. L’objectiu principal és estudiar i simular dos escenaris concrets: l’enviament de notícies des de les torres de control als avions, i l’enviament de canvis de rutes de vol dels avions a un aeroport en qüestió. S’ha simulat el comportament de dos protocols d’encaminament diferents sobre els escenaris creats. Per a realitzar les proves s’ha utilitzat el simulador The ONE, s’ha implementat un nou protocol d’encaminament, s’ha creat un Generador de Mapes i Rutes, i s’han realitzat amb èxit les simulacions.
Resumo:
In vivo imaging of green fluorescent protein (GFP)-labeled neurons in the intact brain is being used increasingly to study neuronal plasticity. However, interpreting the observed changes as modifications in neuronal connectivity needs information about synapses. We show here that axons and dendrites of GFP-labeled neurons imaged previously in the live mouse or in slice preparations using 2-photon laser microscopy can be analyzed using light and electron microscopy, allowing morphological reconstruction of the synapses both on the imaged neurons, as well as those in the surrounding neuropil. We describe how, over a 2-day period, the imaged tissue is fixed, sliced and immuno-labeled to localize the neurons of interest. Once embedded in epoxy resin, the entire neuron can then be drawn in three dimensions (3D) for detailed morphological analysis using light microscopy. Specific dendrites and axons can be further serially thin sectioned, imaged in the electron microscope (EM) and then the ultrastructure analyzed on the serial images.
Resumo:
Introduction: A standardized three-dimensional ultrasonographic (3DUS) protocol is described that allows fetal face reconstruction. Ability to identify cleft lip with 3DUS using this protocol was assessed by operators with minimal 3DUS experience. Material and Methods: 260 stored volumes of fetal face were analyzed using a standardized protocol by operators with different levels of competence in 3DUS. The outcomes studied were: (1) the performance of post-processing 3D face volumes for the detection of facial clefts; (2) the ability of a resident with minimal 3DUS experience to reconstruct the acquired facial volumes, and (3) the time needed to reconstruct each plane to allow proper diagnosis of a cleft. Results: The three orthogonal planes of the fetal face (axial, sagittal and coronal) were adequately reconstructed with similar performance when acquired by a maternal-fetal medicine specialist or by residents with minimal experience (72 vs. 76%, p = 0.629). The learning curve for manipulation of 3DUS volumes of the fetal face corresponds to 30 cases and is independent of the operator's level of experience. Discussion: The learning curve for the standardized protocol we describe is short, even for inexperienced sonographers. This technique might decrease the length of anatomy ultrasounds and improve the ability to visualize fetal face anomalies.