608 resultados para LACTATO DE RINGER


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared acid-base and biochemical changes and quality of recovery in male cats with experimentally induced urethral obstruction and anesthetized with either propofol or a combination of ketamine and diazepam for urethral catheterization. Ten male cats with urethral obstruction were enrolled for urethral catheterization and anesthetized with either ketamine-diazepam (KD) or propofol (P). Lactated Ringer's solution was administered by intravenous (IV) beginning 15 min before and continuing for 48 h after relief of urethral obstruction. Quality of recovery and time to standing were evaluated. The urethral catheter was maintained to measure urinary output. Hematocrit (Hct), total plasma protein (TPP), albumin, total protein (TP), blood urea nitrogen (BUN), creatinine, pH, bicarbonate (HCO3-), chloride, base excess, anion gap, sodium, potassium, and partial pressure of carbon dioxide in mixed venous blood (pvCO(2)) were measured before urethral obstruction, at start of fluid therapy (0 h), and at subsequent intervals. The quality of recovery and time to standing were respectively 4 and 75 min in the KD group and 5 and 16 min in the P group. The blood urea nitrogen values were increased at 0, 2, and 8 h in both groups. Serum creatinine increased at 0 and 2 h in cats administered KD and at 0, 2, and 8 h in cats receiving P, although the values were above the reference range in both groups until 8 h. Acidosis occurred for up to 2 h in both groups. Acid-base and biochemical stabilization were similar in cats anesthetized with propofol or with ketamine-diazepam. Cats that received propofol recovered much faster, but the ketamine-diazepam combination was shown to be more advantageous when treating uncooperative cats as it can be administered by intramuscular (IM) injection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years, different beta titanium alloys have been developed for biomedical applications with a combination of mechanical properties including a low Young's modulus, high strength, fatigue resistance and good ductility with excellent corrosion resistance. From this perspective, a new metastable beta titanium Ti-12Mo-3Nb alloy was developed with the replacement of both vanadium and aluminum from the traditional Ti-6Al-4V alloy. This paper presents the microstructure, mechanical properties and corrosion resistance of the Ti-12Mo-3Nb alloy heat-treated at 950 degrees C for 1 h. The material was characterized by X-ray diffraction and by scanning electron microscopy. Tensile tests were carried out at room temperature. Corrosion tests were performed using Ringer's solution at 25 degrees C. The results showed that this alloy could potentially be used for biomedical purposes due to its good mechanical properties and spontaneous passivation. (c) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess comparatively the inflammatory response that follows CO2 or Ringer's lactate joint capsular distension of horses submitted to experimental arthroscopy METHODS: Each animal was submitted to a bilateral tarsocrural arthroscopy employing gas distention in one joint and fluid distention in the contralateral joint. Synovial fluid was evaluated at 0, six, 12, 24 and 48 hours post-operative. RESULTS: The use of CO2 for arthroscopy causes an acute and mild synovitis alike to the liquid capsular distension, showing similar synovial fluid increase of leukocytes, TP, and TNF-alpha. Although synovial fluid PGE(2) content was higher in joints submitted to CO2 distension, lower levels of hemoglobin and leukocytes oxidative burst after surgery indicates that CO2 arthroscopy decreased intra-articular bleeding and activation of infiltrating leukocytes. CONCLUSIONS: The use of CO2 for arthroscopic examination causes acute and mild synovitis that is similar to the effects caused by the liquid capsular distension. CO2 also seems to decrease intra-articular bleeding and activation of leukocytes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Introduction We conducted the present study to investigate whether early large-volume crystalloid infusion can restore gut mucosal blood flow and mesenteric oxygen metabolism in severe sepsis. Methods Anesthetized and mechanically ventilated male mongrel dogs were challenged with intravenous injection of live Escherichia coli (6 × 109 colony-forming units/ml per kg over 15 min). After 90 min they were randomly assigned to one of two groups – control (no fluids; n = 13) or lactated Ringer's solution (32 ml/kg per hour; n = 14) – and followed for 60 min. Cardiac index, mesenteric blood flow, mean arterial pressure, systemic and mesenteric oxygen-derived variables, blood lactate and gastric carbon dioxide tension (PCO2; by gas tonometry) were assessed throughout the study. Results E. coli infusion significantly decreased arterial pressure, cardiac index, mesenteric blood flow, and systemic and mesenteric oxygen delivery, and increased arterial and portal lactate, intramucosal PCO2, PCO2 gap (the difference between gastric mucosal and arterial PCO2), and systemic and mesenteric oxygen extraction ratio in both groups. The Ringer's solution group had significantly higher cardiac index and systemic oxygen delivery, and lower oxygen extraction ratio and PCO2 gap at 165 min as compared with control animals. However, infusion of lactated Ringer's solution was unable to restore the PCO2 gap. There were no significant differences between groups in mesenteric oxygen delivery, oxygen extraction ratio, or portal lactate at the end of study. Conclusion Significant disturbances occur in the systemic and mesenteric beds during bacteremic severe sepsis. Although large-volume infusion of lactated Ringer's solution restored systemic hemodynamic parameters, it was unable to correct gut mucosal PCO2 gap.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Introduction We conducted the present study to examine the effects of hypertonic saline solution (7.5%) on cardiovascular function and splanchnic perfusion in experimental sepsis. Methods Anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live Escherichia coli over 30 minutes. After 30 minutes, they were randomized to receive lactated Ringer's solution 32 ml/kg (LR; n = 7) over 30 minutes or 7.5% hypertonic saline solution 4 ml/kg (HS; n = 8) over 5 minutes. They were observed without additional interventions for 120 minutes. Cardiac output (CO), mean arterial pressure (MAP), portal and renal blood flow (PBF and RBF, respectively), gastric partial pressure of CO2 (pCO2; gas tonometry), blood gases and lactate levels were assessed. Results E. coli infusion promoted significant reductions in CO, MAP, PBF and RBF (approximately 45%, 12%, 45% and 25%, respectively) accompanied by an increase in lactate levels and systemic and mesenteric oxygen extraction (sO2ER and mO2ER). Widening of venous-arterial (approximately 15 mmHg), portal-arterial (approximately 18 mmHg) and gastric mucosal-arterial (approximately 55 mmHg) pCO2 gradients were also observed. LR and HS infusion transiently improved systemic and regional blood flow. However, HS infusion was associated with a significant and sustained reduction of systemic (18 ± 2.6 versus 38 ± 5.9%) and mesenteric oxygen extraction (18.5 ± 1.9 versus 36.5 ± 5.4%), without worsening other perfusional markers. Conclusion A large volume of LR or a small volume of HS promoted similar transient hemodynamic benefits in this sepsis model. However, a single bolus of HS did promote sustained reduction of systemic and mesenteric oxygen extraction, suggesting that hypertonic saline solution could be used as a salutary intervention during fluid resuscitation in septic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivos de assistência ventricular esquerda (DAVE), associado ou não à descompressão do ventrículo direito por meio de derivação cavo-pulmonar, sendo esses achados comparados ao emprego de assistência circulatória biventricular. MÉTODOS: Vinte e um suínos foram submetidos à indução de insuficiência cardíaca através de fibrilação ventricular, sendo a atividade circulatória mantida por DAVE durante 180 minutos. No grupo controle, foi apenas implantado o DAVE. No grupo derivação, além do DAVE foi realizada cirurgia de derivação cavo-pulmonar. No grupo biventricular, foi instituída assistência biventricular. Foram monitoradas as pressões intracavitárias por 3 horas de assistência e amostras do endocárdio dos dois ventrículos foram coletadas e analisadas à microscopia óptica e eletrônica. RESULTADOS: O lactato sérico foi significativamente menor no grupo biventricular (P=0,014). A diferença observada entre o fluxo do DAVE nos grupos derivação e controle (+55±14 ml/kg/min, P=0,072) não foi significativa, enquanto que o fluxo no grupo biventricular foi significativamente maior (+93±17 ml/kg/min, P=0,012) e se manteve estável durante o experimento. A pressão arterial média (PAM) se manteve constante apenas no grupo biventricular (P<0,001), que também apresentou diminuição significativa das pressões em câmaras direitas. Na análise ultraestrutural, notou-se menor presença edema miocárdico no ventrículo direito no grupo biventricular (P=0,017). CONCLUSÃO: Os resultados apresentados demonstram que o desempenho hemodinâmico da assistência ventricular esquerda associada à derivação cavo-pulmonar, neste modelo experimental, não foi superior ao observado com a assistência de ventrículo esquerdo isolada e não substituiu a assistência biventricular de maneira efetiva.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although several studies on ammonia poisoning have been carried out, there is a lack of information on acid-base balance status in ammonia-poisoned cattle. Twelve crossbred steers received intraruminally 0.5 g of urea per kg of body weight in order to induce a clinical picture of ammonia poisoning. Blood samples were collected throughout the trials in order to determine the blood ammonia, lactate, and perform blood gas analysis. All cattle presented a classical clinical picture of ammonia poisoning, with a blood ammonia concentration rising progressively from the beginning until reaching higher values at 180 min (27 ± 3 to 1719 ± 101 μmol L-1), with a similar pattern occurring with blood L-lactate levels (1.7 ± 0.3 to 26.0 ± 1.7 mmol L-1). The higher the blood ammonia concentration the higher the blood L-lactate levels (r = 0.86). All animals developed metabolic acidosis, as blood pH lowered to 7.24 0.03. The steers tried to compensate the metabolic acidosis mainly through the use of blood buffers and respiratory adjustments by lowering the pCO2 levels in the blood to 32.8 ± 2.0 mm Hg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES] Para determinar la validez del déficit acumulado de oxígeno (DMOA) como índice de capacidad anaeróbica, en 29 varones, estudiantes de Educación Física, se determinó el DMOA, la concentración de lactato en sangre capilar al finalizar un test supramáximo al 120 % VO2max, la potencia media y máxima desarrolladas en el test de Wingate y la masa muscular de las extremidades inferiores mediante absorciometría fotónica dual de rayos X. El DMOA correlacionó con la concentracción de lactato en sangre alcanzada al final del test de capacidad anaeróbica (r=0.43, p<0.05, n=28), con el trabajo realizado y con el VO2 acumulado en el test de capacidad anaeróbica (r=0.59, p<0.001, n=28 y r=0.56, p<0.01, n=29, respectivamente). La lactatemia al final del test de capacidad anaeróbica correlacionó con trabajo realizado en el test de capacidad anaeróbica en valores absolutos (r=0.49, p<0.01, n=27) y con el trabajo divido entre la masa muscular de las extremidades inferiores (r=0.65, p<0.001, n=26). No se observaron correlaciones significativas entre el DMOA y la potencia máxima, ni tampoco entre el DMOA y la potencia media desarrolladas en el test Wingate, ya sea expresadas en valores absolutos o referidos a la masa muscular de las piernas. Tampocó correlacionó la lactatemia alcanzada al final del test de capacidad anaeróbica con la potencia máxima ni con la potencia media desarrollada en el test de Wingate. Aunque conceptualmente el DMOA es el mejor no invasivo procedimiento para medir la capacidad anaeróbica, la ausencia de correlaciones con otras variables que se han mostrado útiles en la evaluación de las cualidades anaeróbicas limita su interés desde el punto de vista práctico.