935 resultados para Intravascular ultrasound sequences
Resumo:
The aim of this study was to identify isolates of Rhizoctonia solani causing hypocotyl rot and foliar blight in soybean (Glycine max) in Brazil by the nucleotide sequences of ITS-5.8S regions of rDNA. The 5.8S rDNA gene sequence (155 bp) was highly conserved among all isolates but differences in length and nucleotide sequence of the ITS1 and ITS2 regions were observed between soybean isolates and AG testers. The similarity of the nucleotide sequence among AG-1 IA isolates, causing foliar blight, was 95.1-100% and 98.5-100% in the ITS1 and ITS2 regions, respectively. The nucleotide sequence similarity among subgroups IA, IB and IC ranged from 84.3 to 89% in ITS1 and from 93.3 to 95.6% in ITS2. Nucleotide sequence similarity of 99.1% and 99.3-100% for ITS1 and ITS2, respectively, was observed between AG-4 soybean isolates causing hypocotyl rots and the AG-4 HGI tester. The similarity of the nucleotide sequence of the ITS-5.8S rDNA region confirmed that the R. solani Brazilian isolates causing foliar blight are AG-1 IA and isolates causing hypocotyl rot symptoms are AG-4 HGI. The ITS-5.8S rDNA sequence was not determinant for the identification of the AG-2-2 IIIB R. solani soybean isolate.
Resumo:
There are several filtration applications in the pulp and paper industry where the capacity and cost-effectiveness of processes are of importance. Ultrafiltration is used to clean process water. Ultrafiltration is a membrane process that separates a certain component or compound from a liquid stream. The pressure difference across the membrane sieves macromolecules smaller than 0.001-0.02 μm through the membrane. When optimizing the filtration process capacity, online information about the conditions of the membrane is needed. Fouling and compaction of the membrane both affect the capacity of the filtration process. In fouling a “cake” layer starts to build on the surface of the membrane. This layer blocks the molecules from sieving through the membrane thereby decreasing the yield of the process. In compaction of the membrane the structure is flattened out because of the high pressure applied. The higher pressure increases the capacity but may damage the structure of the membrane permanently. Information about the compaction is needed to effectively operate the filters. The objective of this study was to develop an accurate system for online monitoring of the condition of the membrane using ultrasound reflectometry. Measurements of ultrafiltration membrane compaction were made successfully utilizing ultrasound. The results were confirmed by permeate flux decline, measurements of compaction with a micrometer, mechanical compaction using a hydraulic piston and a scanning electron microscope (SEM). The scientific contribution of this thesis is to introduce a secondary ultrasound transducer to determine the speed of sound in the fluid used. The speed of sound is highly dependent on the temperature and pressure used in the filters. When the exact speed of sound is obtained by the reference transducer, the effect of temperature and pressure is eliminated. This speed is then used to calculate the distances with a higher accuracy. As the accuracy or the resolution of the ultrasound measurement is increased, the method can be applied to a higher amount of applications especially for processes where fouling layers are thinner because of smaller macromolecules. With the help of the transducer, membrane compaction of 13 μm was measured in the pressure of 5 bars. The results were verified with the permeate flux decline, which indicated that compaction had taken place. The measurements of compaction with a micrometer showed compaction of 23–26 μm. The results are in the same range and confirm the compaction. Mechanical compaction measurements were made using a hydraulic piston, and the result was the same 13 μm as obtained by applying the ultrasound time domain reflectometry (UTDR). A scanning electron microscope (SEM) was used to study the structure of the samples before and after the compaction.
Resumo:
Objective:To evaluate the prevalence of carpal tunnel syndrome in candidates for bariatric surgery comparing with the non-obese population and verify the effects on it of bariatric treatment. Methods:We studiedthree groups of individuals: 1) patients waiting for bariatric surgery (preoperative); 2) individuals who had already undergone the procedure (postoperative); and 3) control group. We collected demographic and clinical data of carpal tunnel syndrome. The Ultrasound examination was carried out to diagnose the syndrome by measuring the median nerve area. Results:We included 329 individuals (114 in the preoperative group, 90 in the postoperative group and 125 controls). There was a higher prevalence of paresthesias (p=0.0003), clinical tests (p=0.0083) on the preoperative group when compared with controls (p<0.00001). There were lowe levels of paresthesias (p=0.0002) and median nerve area (p=0.04) in postoperative patients but with no significant difference in general. A significant difference was found between the preoperative and postoperative groups (p=0.05) in those who performed non-manual work.Conclusion: There was a higher prevalence of carpal tunnel syndrome in the preoperative group compared with the control one, but no significant difference was observed between the pre and postoperative groups in general. There was difference between pre and postoperative groups for non-manual workers.
Resumo:
OBJETIVO: avaliar os efeitos da transfusão intravascular nos índices dopplerfluxométricos do ducto venoso e da veia cava inferior (SV/CA) e relacionar essas alterações com o nível de hemoglobina pré-transfusão intravascular. MÉTODOS: trata-se de estudo transversal prospectivo. Foram realizadas 62 transfusões intravasculares em 27 fetos de gestações complicadas por isoimunização materno-fetal. Os 62 casos foram divididos em dois grupos: (A) fetos com níveis de hemoglobina pré-transfusão £10 g/dL, (B) fetos com níveis de hemoglobina pré-transfusão >10 g/dL. Os índices SV/CA e CA/SV foram medidos usando Doppler colorido 6 horas antes e 12 horas após a transfusão. Compararam-se os valores dos índices antes e após as transfusões em todos os 62 casos, e após a transfusão em cada grupo. O teste de Wilcoxon foi usado para comparação. Os resultados foram considerados estatisticamente significativos quando p<0,05. RESULTADOS: quando estudamos todo o grupo (62 casos), não encontramos diferença significativa no índice CA/SV antes e após a transfusão (p=0,775). No entanto, o índice SV/CA apresentou aumento significativo após a transfusão (p=0,004). Nos fetos com níveis de hemoglobina pré-transfusão £10 g/dL não foi observada diferença significativa nos valores de ambos os índices SV/CA e CA/SV, com p=0,061 e p=0,345, respectivamente. Após a transfusão intravascular houve aumento significativo do índice CA/SV em fetos com níveis de hemoglobina pré-transfusão >10 g/dL (p=0,049), mas o índice SV/CA não se alterou nesse grupo (p=0,086). CONCLUSÕES: o estudo por dopplervelocimetria venosa pode ser útil para a compreensão dos ajustes hemodinâmicos fetais após a transfusão intravascular. O aumento no índice SV/CA sem alteração no índice CA/SV após a transfusão em fetos anêmicos pode ser mecanismo compensatório importante em resposta ao aumento do volume intravascular. O aumento do índice CA/SV em fetos com hemoglobina pré-transfusão <10 g/dL sugere um estado de hipervolemia fetal.
Resumo:
PURPOSE: To evaluate changes to the pelvic floor of primiparous women with different delivery modes, using three-dimensional ultrasound. METHODS: A prospective cross-sectional study on 35 primiparae divided into groups according to the delivery mode: elective cesarean delivery (n=10), vaginal delivery (n=16), and forceps delivery (n=9). Three-dimensional ultrasound on the pelvic floor was performed on the second postpartum day with the patient in a resting position. A convex volumetric transducer (RAB4-8L) was used, in contact with the large labia, with the patient in the gynecological position. Biometric measurements of the urogenital hiatus were taken in the axial plane on images in the rendering mode, in order to assess the area, anteroposterior and transverse diameters, average thickness, and avulsion of the levator ani muscle. Differences between groups were evaluated by determining the mean differences and their respective 95% confidence intervals. The proportions of levator ani muscle avulsion were compared between elective cesarean section and vaginal birth using Fisher's exact test. RESULTS: The mean areas of the urogenital hiatus in the cases of vaginal and forceps deliveries were 17.0 and 20.1 cm², respectively, versus 12.4 cm² in the Control Group (elective cesarean). Avulsion of the levator ani muscle was observed in women who underwent vaginal delivery (3/25), however there was no statistically significant difference between cesarean section and vaginal delivery groups (p=0.5). CONCLUSION: Transperineal three-dimensional ultrasound was useful for assessing the pelvic floor of primiparous women, by allowing pelvic morphological changes to be differentiated according to the delivery mode.
Ultrasound during the second stage of labour: is it effective to reduce the caesarean section rates?
Resumo:
The presence of iron uptake (irp-2, fyuA, sitA, fepC, iucA), adhesion (iha, lpfA O157/O141, lpfA O157/O154, efa, toxB) and invasion (inv, ial-related DNA sequences and assignment to the four main Escherichia coli phylogenetic groups (A, B1, B2 e D) were determined in 30 commensal E. coli strains isolated from healthy chickens and in 49 APEC strains isolated from chickens presenting clinical signs of septicemia (n=24) swollen head syndrome (n=14) and omphalitis (n=11) by PCR. None of the strains presented DNA sequences related to the inv, ial, efa, and toxB genes. DNA sequences related to lpfA O157/O154, iucA, fepC, and irp-2 genes were significantly found among pathogenic strains, where iucA gene was associated with septicemia and swollen head syndrome and fepC and irp-2 genes were associated with swollen head syndrome strains. Phylogenetic typing showed that commensal and omphalitis strains belonged mainly to phylogenetic Group A and swollen head syndrome to phylogenetic Group D. Septicemic strains were assigned in phylogenetic Groups A and D. These data could suggest that clonal lineage of septicemic APEC strains have a multiple ancestor origin; one from a pathogenic bacteria ancestor and other from a non-pathogenic ancestor that evolved by the acquisition of virulence related sequences through horizontal gene transfer. Swollen head syndrome may constitute a pathogenic clonal group. By the other side, omphalitis strains probably constitute a non-pathogenic clonal group, and could cause omphalitis as an opportunistic infection. The sharing of virulence related sequences by human pathogenic E. coli and APEC strains could indicate that APEC strains could be a source of virulence genes to human strains and could represent a zoonotic risk.
Resumo:
The vocal repertoire of some animal species has been considered a non-invasive tool to predict distress reactivity. In rats ultrasound emissions were reported as distress indicator. Capybaras[ vocal repertoire was reported recently and seems to have ultrasound calls, but this has not yet been confirmed. Thus, in order to check if a poor state of welfare was linked to ultrasound calls in the capybara vocal repertoire, the aim of this study was to track the presence of ultrasound emissions in 11 animals under three conditions: 1) unrestrained; 2) intermediately restrained, and 3) highly restrained. The ultrasound track identified frequencies in the range of 31.8±3.5 kHz in adults and 33.2±8.5 kHz in juveniles. These ultrasound frequencies occurred only when animals were highly restrained, physically restrained or injured during handling. We concluded that these calls with ultrasound components are related to pain and restraint because they did not occur when animals were free of restraint. Thus we suggest that this vocalization may be used as an additional tool to assess capybaras[ welfare.
Resumo:
The aim of the present study was the ultrasound characterization of the abdominal and pelvic regions of five maned wolves kept in captivity at the Triage Center of Wild Animals of the Federal University of Viçosa (Centro de Triagem de Animais Silvestres, Universidade Federal de Viçosa). This characterization included descriptions of ultrasonographic aspects and measurements of various structures using B-mode ultrasound. Biometric data were collected to assess the existence of significant linear correlations between these measurements and the measurements obtained by ultrasound. Additionally, hematological and serum biochemistry evaluations of the animals were performed. The ultrasound findings were similar to those available in the literature on domestic dogs, which were used for comparison as a result of the lack of published data regarding maned wolves. The latter species showed characteristics closely resembling those of the former, differing in the spleen and left renal cortex echogenicities, in the appearance of the prostatic and testicular regions and in the hepatic portal vein morphology. In the current study, the biometric values were similar to those previously published; however, no data regarding thoracic perimeter, modified crown-rump length or thoracic depth were found in the literature for this Canidae species. Statistical analysis showed the existence of a strong negative correlation between the modified crown-rump length and left renal length, between the modified crown-rump length and the right renal volume, between the thoracic perimeter and the height at the cranial pole of the left adrenal gland and between the thoracic perimeter and the height at the caudal pole of the left adrenal gland. Laboratory findings, including segmented neutrophil, eosinophil, monocyte and lymphocyte counts and the serum levels of glucose, ALT, alkaline phosphatase, urea, total protein, globulin, creatine phosphokinase, triglyceride, sodium, phosphate, potassium and chloride, were inconsistent with values found by other authors. The ultrasound is a diagnostic imaging method that must be further explored in the medicine of wild animals; therefore, additional research in this area is required.
Resumo:
Avian pathogenic Escherichia coli (APEC) infections are responsible for significant losses in the poultry industry worldwide. A zoonotic risk has been attributed to APEC strains because they present similarities to extraintestinal pathogenic E. coli (ExPEC) associated with illness in humans, mainly urinary tract infections and neonatal meningitis. Here, we present in silico analyses with pathogenic E. coli genome sequences, including recently available APEC genomes. The phylogenetic tree, based on multi-locus sequence typing (MLST) of seven housekeeping genes, revealed high diversity in the allelic composition. Nevertheless, despite this diversity, the phylogenetic tree was able to cluster the different pathotypes together. An in silico virulence gene profile was also determined for each of these strains, through the presence or absence of 83 well-known virulence genes/traits described in pathogenic E. coli strains. The MLST phylogeny and the virulence gene profiles demonstrated a certain genetic similarity between Brazilian APEC strains, APEC isolated in the United States, UPEC (uropathogenic E. coli) and diarrheagenic strains isolated from humans. This correlation corroborates and reinforces the zoonotic potential hypothesis proposed to APEC.
Resumo:
This paper presents an ultrasonic method to measure small concentrations of water in lubricating oil. It uses an ultrasonic measurement cell composed by a piezoceramic emitter (5 and 10 MHz), and a large aperture PVDF receiver that eliminates diffraction effects. The propagation velocity, attenuation coefficient and density of several samples of water-in-oil emulsion were measured. The concentrations of water of the samples were in the range of 0 to 5% in volume, and the results showed that these low concentrations can be discriminated within a resolution of 0.2% in the studied range, using the measurement of the propagation velocity.
Resumo:
The complete SSU rDNA was sequenced for 10 individuals of Cladophora vagabunda collected along the coast of Brazil. For C. rupestris (L.) Kütz. a partial SSU rDNA sequence (1634 bp) was obtained. Phylogenetic trees indicate that Cladophora is paraphyletic, but the section Glomeratae sensu lato including C. vagabunda from Brazil, Japan and France, C. albida (Nees) Kütz., C. sericea (Hudson) Kütz., and C. glomerata (L.) Kütz. is monophyletic. Within this group C. vagabunda is paraphyletic. The sequence identity for the SSU rDNA varied from 98.9% to 100% for the Brazilian C. vagabunda, and from 98.3% to 99.7% comparing the Brazilian individuals to the ones from France and Japan. Sequence identity of the Brazilian C. vagabunda to C. albida and C. sericea vary from 98.0% to 98.6%. The SSU rDNA phylogeny support partially the morphological characteristics presented by Brazilian populations of C. vagabunda. On the other hand, C. rupestris from Brazil does not group with C. rupestris from France, both sequences presenting only 96.9% of identity. The inclusion of sequences of individuals from Brazil reinforces the need of taxonomical revision for the genus Cladophora and for the complex C. vagabunda.
Resumo:
The purpose of this work is to obtain a better understanding of behaviour of possible ultrasound appliance on fluid media mixing. The research is done in the regard to Newtonian and non-Newtonian fluids. The process of ultrasound appliance on liquids is modelled in COMSOL Multiphysics software. The influence of ultrasound using is introduced as waveform equation. Turbulence modelling is fulfilled by the k-ε model in Newtonian fluid. The modeling of ultrasound assisted mixing in non-Newtonian fluids is based on the power law. To verify modelling results two practical methods are used: Particle Image Velocimetry and measurements of mixing time. Particle Image Velocimetry allows capturing of velocity flow field continuously and presents detailed depiction of liquid dynamics. The second way of verification is the comparison of mixing time of homogeneity. Experimentally achievement of mixing time is done by conductivity measurements. In modelling part mixing time is achieved by special module of COMSOL Multiphysics – the transport of diluted species. Both practical and modelling parts show similar radial mechanism of fluid flow under ultrasound appliance – from the horn tip fluid moves to the bottom and along the walls goes back. Velocity profiles are similar in modelling and experimental part in the case of Newtonian fluid. In the case of non-Newtonian fluid velocity profiles do not agree. The development track of ultrasound-assisted mixing modelling is presented in the thesis.